LP SERIES-General Purpose LP6-1.2 (6V1.2AH) Specification Nominal Voltage
6V
Nominal Capacity(20HR)
1.2AH
Dimensions
97 1mm Length 24 1mm Width 51.5 1mm Container Height Total Height (with Terminal) 57.5 1mm
(3.82 inches) (0.94 inches) (2.03 inches) (2.26 inches)
Maint
enance
MH 268
LP6-1
-free Se
BAT MADE TERY CO.,LTD IN CHI
NA
T1
Container Material
ABS
Rated Capacity
1.20 AH/0.060A 1.12 AH/0.112A 1.01 AH/0.202A 0.882 AH/0.294A 0.728 AH/0.728A
AH)
ad-ac
id Batte
CONS
ry
Stand Cycle
.
Pb.
(20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F)
TANT
by us e:
Initial
NonBATTERY spillable MUST BE RECYCLED
Approx 0.29 kg (0.64lbs)
Approx Weight Terminal
.2(6V1.2
aled Le
66
LEOCH
use: curre
VOLTA
GE CH
ARGE
6.75-6
.90
7.20-7
.50
V
nt: V Wa rni Less tha Ris k ng: n 0.3 of fire 6A hea t , abo ve exp los ion , or the 50 O C, or bur ns. Do inc ine rat e. not dis ass em
ble ,
Applications All purpose Uninterruptable Power Supply (UPS)
Max. Discharge Current
18A (5s)
Electric Power System (EPS)
Internal Resistance
Approx 65mÙ
Emergency backup power supply
Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F) Storage : -15 400C (5 1040F)
Emergency light
Operating Temp.Range Nominal Operating Temp. Range
25
Cycle Use Standby Use
Railway signal Aircraft signal
30C (77 50F )
Alarm and security system
Initial Charging Current less than 0.36A.Voltage
Electronic apparatus and equipment
7.2V~7.5V at 250 C(770 F)Temp. Coefficient -15mV/0C
Communication power supply
No limit on Initial Charging Current Voltage
DC power supply
6.75V~6.9V at 250 C(770 F)Temp. Coefficient -10mV/0C
Auto control system
o
o
40 C (104 F) 103% 100% 25o C ( 77o F) 86% 0o C ( 32o F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Capacity affected by Temperature
Self Discharge
VdS
t est ed
9 0
Germany
0
Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
2.30
1.61
1.32
1.15
0.922
0.709
0.580
0.354
0.270
0.222
0.188
0.163
0.130
0.108
0.059
1.80V/cell
2.83
1.92
1.54
1.30
1.02
0.773
0.624
0.376
0.284
0.233
0.196
0.170
0.134
0.112
0.060
1.75V/cell
3.36
2.17
1.69
1.41
1.09
0.821
0.656
0.392
0.294
0.240
0.202
0.174
0.138
0.114
0.061
1.70V/cell
3.81
2.39
1.83
1.52
1.14
0.853
0.684
0.409
0.303
0.246
0.207
0.179
0.140
0.116
0.062
1.65V/cell
4.20
2.57
1.94
1.59
1.19
0.886
0.713
0.421
0.311
0.251
0.211
0.182
0.142
0.117
0.063
1.60V/cell
4.41
2.68
2.02
1.65
1.23
0.906
0.728
0.434
0.318
0.258
0.216
0.186
0.145
0.119
0.063
Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
4.35
3.06
2.55
2.23
1.80
1.39
1.14
0.701
0.536
0.442
0.377
0.327
0.261
0.217
0.120
1.80V/cell
5.28
3.61
2.93
2.50
1.98
1.51
1.22
0.741
0.560
0.462
0.390
0.339
0.269
0.224
0.121
1.75V/cell
6.18
4.05
3.20
2.70
2.10
1.59
1.28
0.768
0.577
0.474
0.399
0.345
0.274
0.226
0.121
1.70V/cell
6.93
4.42
3.43
2.88
2.19
1.64
1.33
0.796
0.592
0.483
0.406
0.352
0.277
0.229
0.122
1.65V/cell
7.54
4.69
3.59
2.99
2.26
1.70
1.37
0.814
0.604
0.490
0.413
0.357
0.280
0.231
0.124
1.60V/cell
7.79
4.82
3.70
3.05
2.30
1.72
1.39
0.834
0.615
0.499
0.419
0.362
0.284
0.234
0.124
1
Dimensions T1 Terminal Unit: mm [inches]
6.35 [0.25]
Discharge Characteristics 6V Battery V
1 5.5
Float Charging Characteristics
0 Temperature:25 0 C(77F)
Charging Current
Charge Volume
6.5
Charging Voltage 0.10CA-2.25V/cell
(XCA)
% 6.0
Terminal Voltage(V)
24
0.8 [0.031]
3.2 [0.126]
1
51.5 1 57.5 1
4.75 [0.187]
97
0
temperature25 C
(V)
0.25 120 110
5.5
0.4C
5.0
7.0
90 80
Charge Voltage (Constant 2.25v/cell)
0.15
6.5
70 60
0.628C
1C
4.5
0.207C
After 50% Discharge
0.10
50
6.0
40 4.0
After 100% Discharge
30
3C 1
2
4
6
2C
8 10
2
60
40
20
4
6 8 10 H
Min
0.05
20 10 0
20
7.5
Charged Volume
0.20
100
0.093C 0.05C
5.5
Charging Current 0 0
8
4
16
12
20
24
32
28
36
40
Discharge Time
Charging Time(hours)
Temperature Effects in Relation to Battery Capacity
Effect of Temperature on Long Term Float Life 10
120
8
Life expectancy(year)
80
Capacity %
6 5 4
A 0 .0 5 C A 0 .1 C
100
0 .2 C A
60
1 .0 C A
40
2 .0 C
20
A
3. 0C A
Charging voltage : 2.25V/cell
3 2
1
0.5
0 -20
-10
30
20
10
0
50
40
20 68
30 86
0
Temperature( C)
60
B
60
400
40
C
20 0
30% DOD
600
800
1000
300C
400C
2
6
4
8
10
12
Storage Time(Months)
Ambient Termperature: 25oC (77oF)
200
A
250C
Remaining Capacity(%)
Capcity(%)
80
50% DOD
100C
80
100
0 0
C F
O
100
120
20
0
Self Discharge Characteristics
Testing condition Discharging:current 0.17C A(FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity.
100% DOD
50 122
Battery temperature
Cycle Life in Relation to Depth of Discharge
40
40 104
A
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA .
C
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.
1200
Number of Cycles
Sales Office China sales office:
North America sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Add: 19751 Descartes, Unit A,
Europe sales office:
Singapore sales office:
HongKong sales office:
Add: 9B Wheatstone Park, Waterwells
Add: No.53,Ubi Avenue 1, #03-21 Paya
Add: Unit 3910,39/F,Cable TV Tower,No.9
Nanshan,Shenzhen, China. 518052
Foothill Ranch, CA 92610, USA
Business Park, Gloucester, GL2 2AQ. UK.
Ubi Industrial Park, Singapore 408934
Hoi Shing Road,Tsuen Wan, NT.H.K
Tel:+8 6-755-86036060 (100 lines)
Tel: 949-588-5853
Tel: +44(0) 01452 729428
Tel:+ 65 6841 6629
Tel: +852 3578 6666
E -mail:
[email protected]
E-mail:
[email protected]
Fax: +86-755-26067269
Fax: 949-588-5966
Fax: +44 (0)1452-690125
E-mail:
[email protected]
E-mail:
[email protected]
E-mail:
[email protected]
Http://www.leoch.com
Http://www.leoch.us
2