LP SERIES-General Purpose LP6-1.2 (6V1.2AH) Specification Nominal Voltage 6V Nominal Capacity(20HR) 1.2AH Dimensions 97 1mm Length 24 1mm Width 51.5 1mm Container Height Total Height (with Terminal) 57.5 1mm (3.82 inches) (0.94 inches) (2.03 inches) (2.26 inches) Maint enance MH 268 LP6-1 -free Se BAT MADE TERY CO.,LTD IN CHI NA T1 Container Material ABS Rated Capacity 1.20 AH/0.060A 1.12 AH/0.112A 1.01 AH/0.202A 0.882 AH/0.294A 0.728 AH/0.728A AH) ad-ac id Batte CONS ry Stand Cycle . Pb. (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) TANT by us e: Initial NonBATTERY spillable MUST BE RECYCLED Approx 0.29 kg (0.64lbs) Approx Weight Terminal .2(6V1.2 aled Le 66 LEOCH use: curre VOLTA GE CH ARGE 6.75-6 .90 7.20-7 .50 V nt: V Wa rni Less tha Ris k ng: n 0.3 of fire 6A hea t , abo ve exp los ion , or the 50 O C, or bur ns. Do inc ine rat e. not dis ass em ble , Applications All purpose Uninterruptable Power Supply (UPS) Max. Discharge Current 18A (5s) Electric Power System (EPS) Internal Resistance Approx 65mÙ Emergency backup power supply Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F) Storage : -15 400C (5 1040F) Emergency light Operating Temp.Range Nominal Operating Temp. Range 25 Cycle Use Standby Use Railway signal Aircraft signal 30C (77 50F ) Alarm and security system Initial Charging Current less than 0.36A.Voltage Electronic apparatus and equipment 7.2V~7.5V at 250 C(770 F)Temp. Coefficient -15mV/0C Communication power supply No limit on Initial Charging Current Voltage DC power supply 6.75V~6.9V at 250 C(770 F)Temp. Coefficient -10mV/0C Auto control system o o 40 C (104 F) 103% 100% 25o C ( 77o F) 86% 0o C ( 32o F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 Germany 0 Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 2.30 1.61 1.32 1.15 0.922 0.709 0.580 0.354 0.270 0.222 0.188 0.163 0.130 0.108 0.059 1.80V/cell 2.83 1.92 1.54 1.30 1.02 0.773 0.624 0.376 0.284 0.233 0.196 0.170 0.134 0.112 0.060 1.75V/cell 3.36 2.17 1.69 1.41 1.09 0.821 0.656 0.392 0.294 0.240 0.202 0.174 0.138 0.114 0.061 1.70V/cell 3.81 2.39 1.83 1.52 1.14 0.853 0.684 0.409 0.303 0.246 0.207 0.179 0.140 0.116 0.062 1.65V/cell 4.20 2.57 1.94 1.59 1.19 0.886 0.713 0.421 0.311 0.251 0.211 0.182 0.142 0.117 0.063 1.60V/cell 4.41 2.68 2.02 1.65 1.23 0.906 0.728 0.434 0.318 0.258 0.216 0.186 0.145 0.119 0.063 Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 4.35 3.06 2.55 2.23 1.80 1.39 1.14 0.701 0.536 0.442 0.377 0.327 0.261 0.217 0.120 1.80V/cell 5.28 3.61 2.93 2.50 1.98 1.51 1.22 0.741 0.560 0.462 0.390 0.339 0.269 0.224 0.121 1.75V/cell 6.18 4.05 3.20 2.70 2.10 1.59 1.28 0.768 0.577 0.474 0.399 0.345 0.274 0.226 0.121 1.70V/cell 6.93 4.42 3.43 2.88 2.19 1.64 1.33 0.796 0.592 0.483 0.406 0.352 0.277 0.229 0.122 1.65V/cell 7.54 4.69 3.59 2.99 2.26 1.70 1.37 0.814 0.604 0.490 0.413 0.357 0.280 0.231 0.124 1.60V/cell 7.79 4.82 3.70 3.05 2.30 1.72 1.39 0.834 0.615 0.499 0.419 0.362 0.284 0.234 0.124 1 Dimensions T1 Terminal Unit: mm [inches] 6.35 [0.25] Discharge Characteristics 6V Battery V 1 5.5 Float Charging Characteristics 0 Temperature:25 0 C(77F) Charging Current Charge Volume 6.5 Charging Voltage 0.10CA-2.25V/cell (XCA) % 6.0 Terminal Voltage(V) 24 0.8 [0.031] 3.2 [0.126] 1 51.5 1 57.5 1 4.75 [0.187] 97 0 temperature25 C (V) 0.25 120 110 5.5 0.4C 5.0 7.0 90 80 Charge Voltage (Constant 2.25v/cell) 0.15 6.5 70 60 0.628C 1C 4.5 0.207C After 50% Discharge 0.10 50 6.0 40 4.0 After 100% Discharge 30 3C 1 2 4 6 2C 8 10 2 60 40 20 4 6 8 10 H Min 0.05 20 10 0 20 7.5 Charged Volume 0.20 100 0.093C 0.05C 5.5 Charging Current 0 0 8 4 16 12 20 24 32 28 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 10 120 8 Life expectancy(year) 80 Capacity % 6 5 4 A 0 .0 5 C A 0 .1 C 100 0 .2 C A 60 1 .0 C A 40 2 .0 C 20 A 3. 0C A Charging voltage : 2.25V/cell 3 2 1 0.5 0 -20 -10 30 20 10 0 50 40 20 68 30 86 0 Temperature( C) 60 B 60 400 40 C 20 0 30% DOD 600 800 1000 300C 400C 2 6 4 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 A 250C Remaining Capacity(%) Capcity(%) 80 50% DOD 100C 80 100 0 0 C F O 100 120 20 0 Self Discharge Characteristics Testing condition Discharging:current 0.17C A(FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 100% DOD 50 122 Battery temperature Cycle Life in Relation to Depth of Discharge 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office China sales office: North America sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Add: 19751 Descartes, Unit A, Europe sales office: Singapore sales office: HongKong sales office: Add: 9B Wheatstone Park, Waterwells Add: No.53,Ubi Avenue 1, #03-21 Paya Add: Unit 3910,39/F,Cable TV Tower,No.9 Nanshan,Shenzhen, China. 518052 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2 2AQ. UK. Ubi Industrial Park, Singapore 408934 Hoi Shing Road,Tsuen Wan, NT.H.K Tel:+8 6-755-86036060 (100 lines) Tel: 949-588-5853 Tel: +44(0) 01452 729428 Tel:+ 65 6841 6629 Tel: +852 3578 6666 E -mail: [email protected] E-mail: [email protected] Fax: +86-755-26067269 Fax: 949-588-5966 Fax: +44 (0)1452-690125 E-mail:[email protected] E-mail: [email protected] E-mail: [email protected] Http://www.leoch.com Http://www.leoch.us 2