Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Sensing the future Colour coded LCD with alarm point location in metres or feet Max: 50 ohms Short term Fire-proof interconnecting cable RS232 TX Transmit from Eurofyre Interface....Pin 1 (RS232 serial link) RS232 Ground.................................................Pin 3 (available on type) RS232 RX Receive at Eurofyre Interface........Pin 4 (ZI-01RS only) 2000 Fyreline EF-ZI01 Interface Unit Alarm Fault Signals to central fire alarm panel 24Vdc local input supply (18-36 Vdc range) or from central panel loop power Backlit display will be disabled due to the lack of sufficient loop power Junction Box End of Line Termination Box with open circuit monitoring resistor FyreLine FM approved & UL listed Linear Heat Sensor Cable (2 conductors) Description The FyreLine type EF-ZI01 has been designed as an opitional low power single zone interface unit for exclusive use in conjunction with up to 2000m/650ft of the proline type “TH” digital linear heat sensor cable range. The unit can be powered either by the central fire alarm control panel loop (12-36Vdc) or from a dedicated (18-36Vdc) supply. The back light and RS232 option are disabled when using the Central Fire Alarm Control Panel loop to provide the EF-ZI01 operating supply, due to limitation in available power from the loop. The LCD display will indicate the abbreviation: “STBY” with a continous GREEN back light to confirm supply available and normal operating condition status for the interface, its associated type “TH” digital linear heat sensor cable and non heat sensitive inter-connecting cable where used. Under open circuit FAULT conditions the display will change to read “HIGH or OPEN” (depending on the version) and the GREEN back light will flash. In an alarm state, the backlit display will change in colour from GREEN to RED, and visually indicate alternating non-latching “FIRE” and an “xxxx” message (where “xxxx” indicates the location of the alarm along the heat sensor cable in feet or metres). The FIRE signal WILL be latched at the Central Fire Alarm Control Panel to which the interface has been connected. Where non heat sensitive cable is installed (as between the sensor cable protected risk area and remotely installed interface unit) the electrical resistance of any interconnecting cable can be zero offset during site commissioning by way of a single “push button” operation. In the event interconnecting cable is installed in lengths with electrical resistance in excess of the allowed 50 ohms, the LCD display will register “CABLE” with a flashing green back light as a calibration error signal. General Hazardous Area Use The FyreLine single “zone” OPTIONAL interface unit type EF-ZI01 provides end user customers with: • Alarm Point Location • Colour coded LCD display • Volt free contact output signalling for fire & fault conditions – with RS232 serial link (model ZI-01RS only) • Ease of Integration with Central Fire Alarm Control and Building Management Panels EF-ZI01 and EF-ZI01RS interface units MUST be installed within a site designated “SAFE” area – using short term fire-proof interconnecting cable between the interface and hazardous area installed Eexe junction box and “TH” linear heat sensor cable. L I M I T E An MTL 7758+ zener barrier – ATEX approval BAS01ATEX7217/EX01E2219/3010737 is to be connected between the EF-ZI01 or EF-ZI01RS sensor cable connection terminals and interconnecting/linear heat sensing cable. D U n i t C 1 , K n o w l e V i l l a g e B u s i n e s s P a r k , M a y l e s L a n e , W i c k h a m , F a r e h a m , P O 1 7 5 D Y, Te l : 0 1 3 2 9 8 3 5 0 2 4 , F a x : 0 1 3 2 9 8 3 0 4 6 2 , E m a i l : i n f o @ e u r o f y r e . c o . u k Features Single zone monitoring 2,000m (6500ft) FyreLine type “TH” digital linear heat sensor cable Alarm point location Displayed in metres or feet Coloured coded back lit lcd display Green to Red (Alarm) Solid-state volt-free contact outputs Alarm and Fault (Fault contacts N/C or N/O-C-N/C to be specified on order) 2 part terminal blocks For ease of wire connection in restricted locations Where necessary, interconnection cabling can be used Max. 50 ohms resistance IP65 rated enclosure NEMA 4X equivalent May be powered from Central Fire Alarm Control Panel loop or dedicated 24Vdc supply Back lit display will not operate with Loop Power – insufficient current available EF-ZI01RS version provides RS232 serial interface Repeat onto customer panel or PC of information displayed on LCD Tested to EN61000-6-2; 2001 and EN61000-6-3; 2001 For emissions and immunity Certificate MTL02ATEX7700CX ATEX II3 when used with MTL 7758+ zener barrier Specification Supply Current limited from central panel loop OR dedicated nominal 24Vdc input Operating Currents Loop Supply: 1.2mA @ 24Vdc – RS232 option incl:) Alarm Current ZI-01: Maximum 15mA @ 24Vdc Monitoring current on associated “TH” sensor cable ZI-01RS: Maximum 40mA @ 24Vdc On board surge/transient/EMC and EMI protection 3ma @ 1V Tested to EN61000-6-2; 2001 and EN61000-6-3; 2001 Read out in Metric or Imperial units For emissions and immunity Solid-state volt-free output contacts Jumper J7 setting Fault monitoring either N/C contacts (open on fault) FIRE and FAULT: 250 ohms/Max 60Vdc/100ma Over current/voltage protected N/C contacts (open on fault) or N/O – C – N/C contacts (requirements to be specified on order) Ambient Temperature Range Humidity 0°C to +70°C Enclosure dimensions in mms Max 95% Unit Weight (gross) 120 (H) x 200 (W) x 75(D) 2kgs EF-ZI01 Interface Connection Diagram EF-ZI01RS Interface Connection Diagram Backlit LCD Backlit LCD Tx transmit from FyreLine Interface Unit RS232 Connections On Underside of Board GND Rx receives at the FyreLine Interface Unit FyreLine “TH” Sensor Cable FyreLine “TH” Sensor Cable Green - Standby = Healthy Flashing Green - Open or High = Fault Red - Fire + Location = Alarm IP65 Junction Box S2 Calibration Button J7 Metres/Feet Selector J3 Sensor cable Connection 470 ohm End of Line resistor Interconnecting Cable if required J8 Fault Output Fault output connectionsNOT polarity sensitive J4 Fire Output Fire output connections NOT polarity sensitive J2 24Vdc Supply Loop = terminal to be used only if power supplied from a central panel address loop. Loop +24v J5 Fault Output Fault output connectionsNOT polarity sensitive Fire output connections NOT polarity sensitive 470 ohm End of Line resistor J3 Sensor cable 0v J2 24Vdc Power Loop +24v 0v Alarm + Fault resistor values: minimum 330 ohms @ 24Vdc For dedicated 24Vdc supply use +24v and 0v terminals only Alarm + Fault resistor values: minimum 330 ohms @ 24Vdc L I M I T E D U n i t C 1 , K n o w l e V i l l a g e B u s i n e s s P a r k , M a y l e s L a n e , W i c k h a m , F a r e h a m , P O 1 7 5 D Y, Te l : 0 1 3 2 9 8 3 5 0 2 4 , F a x : 0 1 3 2 9 8 3 0 4 6 2 , E m a i l : i n f o @ e u r o f y r e . c o . u k