Transcript
Perimeter Detection Systems
SORHEA CONNECT
C
on
ne
ct
Intrusion detector radio connection systems
The CONNECT module is used to connect remote MAXIBUS hub intrusion detectors over a D.R.N. secure dynamic meshed radio network.
Product + Easy and quick to deploy and implement Retrieval and centralisation of all alarm information by radio network Secure alarm information return Perimeter detection System evolution
active fence technology infrared
technology
integration technology
microwave
Centralisation MAXIBUS CONNECT is the single interface to manage all perimeter intrusion detectors present on site. INSTALLATION Dynamic meshed radio network Alarm outputs: • Up to 136 dry contacts • MODBUS TCP protocol • New SDK for integration into VMS
Reliability
MAINTENANCE
The SORHEA CONNECT can connect at the same time:
General history of 100 events, detailed by detected connector
A D.R.N. radio network An RS485 line-connected network
Communication interface by integrated web server
These two communication modes may be used individually or at the same time to provide backup.
Integrated graphic configuration tool
Infrared rrières barriers infrarouge Impact étection detection de chocs Hyperfrequency rrières barriers hyperfréquence
Simplicity MA
Configuration via Bluetooth Low Energy in secure mode via Smartphone apps.
XIB US C
ON
Alarm input configuration
NEC
Local history reading
T
Dual étecteurs technology double detectors technologie Other utres detectors détecteurs
Security The group of CONNECT Modules form a secure meshed radio network which uses D.R.N. technology.
Dynamic radio network
Site extension
INSTALLAT I
WITHOUT ON
Single alarm message identification
Recovery of the alarm information from all relay output detectors present on the site
OR CI V I L W
Watch-dog: permanent control on the presence of the CONNECT modules on the radio network
Existing site recovery and site extension without civil engineering works.
•
Security: AES 256-encrypted SORHEA proprietary radio protocol
Scalability
KS
•
TECHNICAL CHARACTERISTICS CONNECT MODULE Alarm information
11 On/Off inputs
Alarm transmission
Dynamic meshed radio network to radio coordinator
Radio frequency
19 radio channels distributed across 3 bands: 865 Mhz – 868 Mhz | 15 channels 868 Mhz – 868.6 Mhz | 3 channels 869.7 Mhz – 870 Mhz | 1 channel LORA modulation
Data encryption
256 bits AES
Power supply
4 Vdc – 26 Vdc range (10Mw consumption under 4 Vdc)
Operating temperature
-35°C to +70°C
Electromagnetic compatibility
Compliant with European standards (EC label)
Configuration via Bluetooth LowEnergy connection
RADIO COORDINATOR Alarm transmission
RS485 compatible MAXIBUS CONNECT
Configuration tools
Embedded HTML server Integrated site mapping
Power supply
12 Vdc (40 mA)
Operating temperature
-35°C to +70°C
Seal of the retailer NC233-EN V1.0 11.16
In order to continuously ensure the high standard of quality and performance of our products, we reserve the right to modify the present technical data without notification.
1 rue du Dauphiné - 69120 VAULX-EN-VELIN - FRANCE Tél. : +33(0)4 78 03 06 10 Fax : +33(0)4 78 68 24 61 e-mail :
[email protected]
www.sorhea.com