Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

COMPOSITE WIRING DIAGRAM 230/208/60-3 GREEN R Orange 240V 208V C Green COM 15 Transformer BLACK/WHITE "X" THERMOSTAT OPTION 31 39 4115-102 Purple Red/Yellow A Brown/White Y2 Purple G Orange A Brown/White Y1 Yellow G Orange O/B Blue W1/E PLUG #2 1 2 Y1 Yellow O/B Blue 4 W2 Brown 6 R Red/White C Black/White L Pink 3 5 R Red/White C Black/White L Pink 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 12 Brown W2 Temp. and Humidity Controller Part #8403-060 PLUG #1 12 Red Red Black Yellow Yellow Orange 24VAC Black Brown Analog Out Green 1 2 3 4 5 6 Brown Orange "D" THERMOSTAT OPTION Green 4115-100 CO2 Controller Part #8403-056 RED BLACK GREEN BLACK/WHITE PINK RED/WHITE 27 "H" THERMOSTAT OPTION 4115-101 L2 L3 T1 T2 T3 Optional High Speed Solenoid 1 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS 2 FOR 208V OPERATION, MOVE THIS RED WIRE TO 208V TRANSFORMER TAP 3 REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED CC ALR R Y C 1 38 39 39 4 5 3 2 1 BLACK/ WHITE 35 35 1 36 36 2 3 OPTIONAL3-PIN PLUG FOR ERV 1 BLUE BLUE BLACK/WHITE Reversing Valve 48 RED L2 L1 24 HPC LPC LPC 2 1 12 PIN VENT PLUG Field BLACK/WHITE YELLOW 12 11 10 9 8 7 6 5 4 3 Low Voltage PLUG #2 L1 27 High Voltage Red/Yellow Y2 RED/ WHITE 33 18 Check Light Comp. Control Module 37 RED 230/208 VOLT PACKAGE UNIT DIAGRAM 34 YELLOW/RED 32 Factory W1/E BROWN/WHITE 2 42 YELLOW ORANGE 27 6 PIN CO2 PLUG 41 RED BLACK YELLOW PINK 44 L3 43 27 BROWN L2 YELLOW BLACK/WHITE 38 C Phase Monitor L1 BLUE Brown 39 RED/WHITE BLACK/WHITE 4 5 6 Yellow 38 RED/WHITE 38 YELLOW 33 LOW VOLTAGE STRIP BROWN Black 1 2 3 Red Black Yellow Brown Orange Green Red Temp. and Humidity Controller Part #8403-060 BROWN BLUE 12 10 2 21 YELLOW 5 40 Y Yout RED BL OWER VEN T R EL AY RED/WHITE 24VAC Analog Out 19 Compressor Contactor RED/WHITE Terminal Strip CO2 Controller Part #8403-056 1 4 10 34 RED 14 BLACK/ WHITE 10 4 Ground Terminal YELLOW Pink 3 10 10 27 RED L 10 ORANGE BROWN/ WHITE YELLOW 30 BLUE L O1 Y Y1 C 4 10 YELLOW/BROWN Black/White BROWN RED Red/White C ORANGE YELLOW BLUE/WHITE R 7 8 9 10 11 12 R C BLUE Circuit 5 Breaker PURPLE Brown BLACK/WHITE W2 BLACK W2 PURPLE PINK Blue RED/YELLOW YELLOW O BLACK 29 RED O/B RED 28 GREEN Yellow L1 L2 L3 BLACK Y1 208/230-60-3 POWER SOURCE 11 5 PIN PLUG FOR INDOOR BLOWER MOTOR 3 4 5 RED/WHITE Y1 PURPLE/WHITE Orange GRAY G YELLOW G 12 PIN PLUG FOR THERMOSTAT 10 ORANGE Brown/White BLACK/WHITE Purple A BROWN/WHITE C Y2 A Terminal Block #1 ("A" Ctrl. Opt. Only) YELLOW NC Y2 3 O1 Y Y1 C PURPLE NO Red/Yellow BLACK/WHITE BLACK/WHITE C E 14 12 15 3 1 10 6 9 13 2 BLACK/W NC W1/E 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 1 2 3 4 5 6 NO PWR Low Voltage Terminal Strip PURPLE HVAC AREA OCCUPIED Temp. and Humidity Controller Part #8403-060 RED/WHITE Optional CS2000A Energy Monitor (Use With "A" Thermostat Only) Hi Pressure Control L3 Low Pressure Control Low Pressure Control YELLOW Compressor 4113-200 4 REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED 99 ! Wire Identification numbers for Bard use only. DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Bard Mfg. Co. Bryan, Ohio 4113C200 A