Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

RELAYS ™ www.turck.us Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com YOUR AUTOMATION SOLUTIONS PROVIDER PROXIMITY SENSORS CORDSETS I/O SOLUTIONS MEASUREMENT TURCK’s global support network consists of over 2,500 employees in 25 countries and 60 exclusive agencies worldwide that strive to meet customer expectations. Our sales, support and manufacturing facilities are strategically located across the world allowing us to respond to local market conditions and deliver customer specific solutions on a timely basis. RFID We are a world leader in automation technology with a diverse and broad product portfolio that provides customer specific applications with high performance, reliable and cost effective solutions. The synergy in our product portfolio and customization flexibility are key components of our value proposition. INTERFACE MODULES Our expertise spans across two major industry categories: Industrial Automation and Process Automation. Each weighs in with its own unique requirements and methods of conducting business. This market centric approach ensures that we develop application specific solutions across a variety of vertical market segments. CUSTOM CONNECTIVITY POSITION NETWORK MEDIA www.turck.us Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 RELECO by TURCK RELAYS Introduction 6 Relays 15 Sockets 63 Timers 83 RINT 87 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 3 Application Types Poles AC Ratings DC Ratings Page Sockets Page C2-A20 Universal 8-Pin, Standard 2 10 A @ 250 V 0.5 A @ 110 V 16 S2 64-66 C3-A30 Universal 11-Pin, Standard 3 10 A @ 250 V 0.5 A @ 110 V 19 S3 66-69 C4-A40 Square Base, 4-Pole 4 10 A @ 250 V 0.5 A @ 110 V 28 S4 70-71 C5-A20 Square Base, AC Power 2 16 A @ 500 V 0.5 A @ 110 V 31 S5 71-72 C5-A30 Square Base, AC Power 3 16 A @ 400 V 0.5 A @ 110 V 32 S5 71-72 C7-A10 Miniature, AC Power 1 16 A @ 250 V 0.5 A @ 110 V 38 S7 73-76 C7-A20 Miniature, AC Power 2 10 A @ 250 V 0.5 A @ 110 V 39 S7 73-76 C7-A20E Miniature, AC Power 2 10 A @ 250 V 0.5 A @ 110 V 40 S7 73-76 C9-A41 Miniature, 14-Pin Plug-in 4 5 A @ 250 V 0.2 A @ 110 V 48 S9 76-77 C10-A10 Interface Standard 1 10 A @ 250 V 0.5 A @ 110 V 51 S10 78-80 C10-A10E Interface Standard 1 10 A @ 250 V 0.5 A @ 110 V 52 S10 78-80 C12-A21 Interface Standard 2 5 A @ 250 V 0.5 A @ 110 V 56 S12 80-81 C2-T21 Universal 8-Pin Plug-in 2 6 A @ 250 V 6 A @ 30 V 17 S2 64-66 C3-T31 Universal 11-Pin Plug-in 3 6 A @ 250 V 6 A @ 30 V 20 S3 66-69 C7-T21 Miniature 2 6 A @ 250 V 6 A @ 30 V 41 S7 73-76 C10-T13 Interface Twin 1 6 A @ 250 V 6 A @ 30 V 54 S10 78-80 C10-GT13 Interface Twin N.O. 1 6 A @ 250 V 6 A @ 30 V 55 S10 78-80 C7-H23 Miniature 2 10 A @ 250 V 6 A @ 30 V 44 S7 73-76 C2-G20 Universal 8-Pin Plug-in 2 10 A @ 250 V 1.2 A @ 110 V 18 S2 64-66 C3-G30 Universal 11-Pin Plug-in 3 10 A @ 250 V 1.2 A @ 110 V 21 S3 66-69 C5-G30 Square Base 3 16 A @ 400 V 1.2 A @ 110 V 33 S5 71-72 C7-G20 Miniature 2 10 A @ 250 V 0.8 A @ 110 V 42 S7 73-76 C10-G10 Interface N.O. 1 10 A @ 250 V 0.8 A @ 110 V 53 S10 78-80 Flag Available C12-G21 Interface N.O. 2 5 A @ 250 V 0.8 A @ 110 V 57 S12 80-81 Double Make C3-X10 11-Pin, DC Power 1 10 A @ 250 V 7 A @ 110 V 23 S3 66-69 C4-X20 Square Base, DC Power 2 10 A @ 250 V 7 A @ 110 V 29 S4 70-71 C5-X10 Square Base, DC Power 1 16 A @ 400 V 7 A @ 110 V 34 S5 71-72 C7-X10 Miniature, DC Power 1 10 A @ 250 V 6 A @ 110 V 43 S7 73-76 General Purpose Bifurcated Contacts Low Level Loads Bifurcated Contacts Current Level Loads Open Contacts DC Load Switching Flag Not Available DC Load Switching Flag Not Available Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 Application Types Poles AC Ratings DC Ratings Page Sockets Page C3-R20 11-Pin Plug-in 2 10 A @ 250 V 0.5 A @ 110 V 24 S3 66-69 C4-R30 Square Base, 14-Pin 3 10 A @ 250 V 0.5 A @ 110 V 30 S4 70-71 C5-R20 Square Base 3 10 A @ 400 V 0.5 A @ 110 V 37 S5 71-72 LED Not Available C9-R21 Miniature 2 5 A @ 250 V 0.2 A @ 110 V 49 S9 76-77 Magnet Blow-out C3-M10 11-Pin Plug-in, High DC Load 1 10 A @ 250 V 10 A @ 220 V 22 S3 66-69 C5-M10 Square Base, High DC Load 1 16 A @ 400 V 10 A @ 220 V 35 S5 71-72 C5-M20 Square Base, High DC Load 2 16 A @ 250 V 7 A @ 110 V 36 S5 71-72 C3-E24 Universal 11-Pin Plug-in 2 6 A @ 250 V 6 A @ 30 V 25 S3 66-69 C3-N34 Universal 11-Pin Plug-in 3 6 A @ 250 V 6 A @ 30 V 26 S3 66-69 Flag Not Available C9-E21 Miniature 2 5 A @ 250 V 5 A @ 30 V 50 S9 76-77 Lamp Switching C7-W10 Miniature, FASTON 187 1 10 A @ 250 V 0.5 A @ 110 V 45 S7 73-76 Railway Applications R3-N30D Universal 11-Pin Plug-in 3 6 A @ 250 V 6 A @ 30 V 27 S3 66-69 R7-A20D Miniature 2 10 A @ 250 V 10 A @ 30 V 46 S7 73-76 R7-T21D Miniature, Twin Contacts 2 6 A @ 250 V 6 A @ 30 V 47 S7 73-76 CSS-AC Instantaneuos 1 3 A @ 250 V N/A 60 S10 78-80 CSS-AZ Zero-cross 1 3 A @ 250 V N/A 61 S10 78-80 CSS-DCN Common Negative 1 N/A 2 A @ 50 V 59 S10 78-80 CSS-DCP Common Positive 1 N/A 2 A @ 50 V 58 S10 78-80 CT2 8-Pin Plug-in Timer Module 2 10 A @ 250 V 0.5 A @ 110 V 84-85 S2 64-66 CT3 11-Pin Plug-in Timer Module 3 10 A @ 250 V 0.5 A @ 110 V 84-85 S3 66-69 RINT Interface Module N/A 6 A @ 250 V 2 A @ 24 V 88-91 Latching Sensitive 500 mW - 800 mw Solid State Relay Time Cube Interface Module Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 5 System Features & Benefits Button and lockable level with 3 functions Mechanical and LED indication as standard Coil voltage marked on top of the relay Label Five Colors for Easy Identification of Coil Voltage • Red: 120 VAC Optional built-in suppressor • Maroon: AC other than 120 V AC Part number and technical information marked on the side of the relay • Grey: VAC/DC Color coded test button • Dark Blue: DC other than 24 V DC Industrial terminals FASTON.098 (2.5 mm) • Blue: 24 VDC If you do not want the lockable function, you can use the orange dead-man-push-button. S0-OP for MRC and S9-OP for QRC (5 piece bag). Push-to-Test-Pull-to-Lock button (PTPL) • Dead-man-push-button A black blanking plug is available if you don't want a test button. S0-NP for MRC and S9-NP for QRC (5 piece bag). Label Double window for the mechanical identification Coil voltage marked on the top face of the relay LED LED • Blanking Plug Comprehensive Technical Label • Coil Power • Wiring diagram with sequential and DIN numbers • Electrical diagram showing all additions to the coil • Maximum switching capacity according to EN 60947 (IEC 947) • Approvals Country Approval Canada Authority: CSA Specification: C 22.2; UL 508 Label Country China Authority: CQC Specification: GB14048.5-2001 Russia Authority: KORPORATSIA STANDARD Specification: GOST R 50030.5.1 United Kingdom USA Approval Authority: Lloyd´s Register of Shipping Authority: UL Specification: C 22.2; UL 508 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 Industrial Relays MRC, QRC, IRC Part Number Key Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified. C n(n) - T S y zz /...V Ref. nnnn Normal Industrial Relay code Ref. nnn Relays with code R are used for railway series. Relays with a reference number are versions with special (e.g. customised) features. These features may relate to special test criteria, tolerances or other properties. Basic type refers to the product line Availability of such relays may be limited to certain customers or applications. Numbers between 2 and 12 are used. Nominal coil voltage or current Relay Type AC … V, DC … V, UC … V (AC/DC), AC … A, DC … A A E G H = = = = M = N R S T W = = = = = Standard (general-purpose) contact Sensitive drive with 500 mW coil power Refers to a NO contact Single-point contact + twin contact load to signal current circuit for switching state feed back. Mixed contact configuration Relay with highly effective neodimium blow magnet for fast quenching of the arc. This relay is particularly suitable for high DC loads. Sensitive drive 800mW coil power Code for remanence relays, drive-specific ID Sensitive drive with 250 mW exciter input Twin contact for signal and control circuit With tungsten contact for maximum switch-on currents Relays are generally available for voltages of 6 V. DC 220 V/AC 240 V (AC 400 V) or UC 6 . 48 V. Current relays available on request. Options D F R X B = = = = = Integrated freewheeling diode Integrated freewheeling diode and series diode e.g. for common alarm circuits RC connection for the coil Electric position indicating device with LED Bridge rectifier Definition of Contact Material This code may differ depending on type. Examples: 0 = in the standard range stands for AgNi 1-9 = see contact material for each type Number of Contacts Product range Releco offers a wide range of relay types and versions and associated bases and accessories. Standard (general-purpose) relay, MRC series 35 x 35 mm round plug-in relay, 8- or 11- terminals multipole connector according to IEC 67 with 2 or 3 contacts up to 10 A and different contact types and contact materials. Standard relay 35 x 35 mm with flat blade connectors with up to 4 contacts and up to 16 A with 3 contacts. Miniature industrial relay, QRC series 22.5 mm series with up to 4 contacts and up to 10 A with 1 or 2 contacts Interface relay, IRC series Overall width 13 mm with up to 2 electromechanical contacts, or fully electronic switches. Electronic relay, CSS In the IRC series different electronic DC or AC relays up to 3 A are available. For AC relays a distinction is made between synchronously (zero crossing) and asynchronously switching versions. For switching transformer loads we recommended using asynchronously switching semiconductor switches. For incandescent lamp loads etc. synchronously switching switches are ideal for avoiding high switch-on currents. Accessories Suitable bases are available for the different relay series for DIN rail mounting or panel mounting. In addition, retaining clips are available for the relays, some of which are included in the scope of supply. Suitable bridges for cost-saving wiring in series are also available. Special relays, remanence relays While "normal" relays are monostable, i.e. they return to the idle state when the excitation is switched off, remanence relays are bistable, i.e. the current switching state is retained irrespective of the excitation. Relays of this type are available in different versions. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 7 General Information Terminology and Technical Information Contact Materials Silver-nickel (AgNi) and silver-tin oxide (AgSnO2) are used as standard contact materials for all models. Other contact materials are available on request. Maximum Itntensity The “Max. switching current” indicated in every model, refers to the maximum stable current which should be possible in permanent conduction (ITH). Gold Flash For relays that are intended to be stored or remain unoperated for any length of time, a 0.2µ layer of gold protects the contacts from oxidization. In the case of AC, the “Max. switching current” that the relay can support is the same for all the values of voltages ≤ of the “Max. switching voltage” specified in every model. Gold Plating A 10µ plate of gold increases the operational reliability. It should be used for switching low level currents. The product of the intensity and the voltage applied should not be higher than the values specified as “Max. AC load”. Contact Resistance Contact resistance is dependent on contact material, contact pressure and contact contamination. In the case of DC, the “Max. switching current” must be less than the current that causes the continuous arcing. The tables of “Max. DC current” show the possible values of intensity in relation to the applied voltage. High contact resistance raises the temperature of the contacts, therefore reducing their working life. Typical contact resistance of the MR-C and QR-C relays is 50 mΩ. Maximum Voltage The maximum voltage on the contacts depends on the insulation between each contact (pole-to-pole) and between all contacts and the coil. Contacts Gap Contact gap and opening speed of the contacts have an influence on the length and the duration of the arc. In the case of AC, a gap of 0.5 mm is sufficient to quench the arc which occurs automatically at the “zero point” of the cycle. In the case of DC, the arc only quenches when the contact gap is sufficient for the voltage and current applied. Please see tables of “Max. DC Current”. Coil Materials Coil bobbins are molded in polybutylene with fiberglass (130°C). The EN 60947 and VDE 0110 standards set out the maximum voltage values, taking into consideration the quality of the insulation materials, pollution degree as well as the shape and dimensions of the contact barriers (creepage distance). Contacts in Series The connection of two or more contacts in series is equivalent to multiplying the contact gap by that amount. By using this method, a greater break capacity is achieved for DC switching. Minimum Working Voltage (pull in) This is the minimum voltage that must be supplied to the coil to ensure that the relay energizes, the contacts change over and are positively held in place without any vibration. Enamelled wires of Class F specification are used (155°C). They are wound on precision automation winding machines, with the number of turns and wire tension accurately regulated and monitored. The values of voltage specified are those at or below which the relay must pull in. Tolerances Coil resistance is measured at 20°C and is regulated within ±10% of specified value. Standard Windings The coil voltages indicated in the catalog refer to standard windings. Other coil voltages are available, including products for series connection and amperometric applications. Please consult your distributor for details. Working at: AC 50 Hz Relays AC 60 Hz Relays DC Relays 50 Hz 60 Hz 0.8xUn 0.85xUn 0.75xUn 0.8xUn 0.8 x Un Maximum Release Voltage (drop out) This is the voltage at which the relay de-energizes, the contacts change over and are positively held in place without any vibration. The values of voltage specified are those at or above which the relay must drop out. DC relays ≤10% Un AC relays ≤20% Un Contacts in Parallel The connection of two or more contacts in parallel does not mean that it is possible to switch a greater load. However, the stable current and the operational reliability of the relay is increased. Double Make Contacts The double make contact arrangement is equivalent to two contacts connected in series. The maximum intensity supported corresponds to only one contact. This system allows for higher DC operating voltages. Bifurcated (Twin) Contacts The contact blade is divided into two parts, each with its own contact. Both contacts press down on their own independent fixed contacts. This system is particularly good for switching at very low levels of current. Contact Protection The electrical life of contacts can be prolonged by components which eliminate or reduce the back EMF transients. These voltages are generated by the reactive component of the load on disconnection, which increases the duration and the temperature of the arc. For AC, RC suppressors or varistors can be connected in parallel with the load or the contacts. For DC with an inductive load, the best method is to connect a diode in parallel with the load. Ambient Temperature The ambient temperature has an influence on the coil resistance and on its thermal dissipation capacity. Curve 1 represents the variations of the pull in voltage (%Un) in relation with the ambient temperature (T). Curve 2 indicates the maximum values of the voltage applied (Ub) to the coil in relation with the nominal voltage (Un) at the ambient temperature (T). Ub /Un 1.7 1.5 2 1.3 1.1 0.9 1 0.7 0.5 -20 -5 10 25 40 55 70 T°C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 8 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 General Information Relay Types Based on Applications General Purpose Relays These are used for most general applications, such as automation, pneumatic, heating appliances, signaling, as an input or output interface, etc. A Change-over contacts. Isolation between N.O./N.C.: 1000 Vrms Gap: 0.5 mm Rating loads of up to: 16 A @ 230 V AC1 16 A @ 30 V DC1 0.5 A @ 110 V DC1 0.2 A @ 220 V DC1 T Relays with Open Contacts An open contact arrangement allows an increase in the contact gap, increasing the DC “break capacity” without altering the AC performance. G Gap: 1.5 mm(QR-C types); 1.7 mm(MR-C) Isolation of contacts NO: >2000 Vrms Maximum load: 16 A @ 230 V AC1 1.2 A @ 110 V DC1 0.4 A @ 220 V DC1 Double Make Relays These relays are designed to switch high DC loads at voltages of 110 and 220 VDC. X Relays with Twin Contacts These are used to switch low currents with high operational reliability. Change-over contacts. Isolation between contacts N.O./N.C.: 1000 Vrms Gap: 0.5 mm Gold-flashed contact 0.2µ or plated with 10µ Au (optional). Maximum load: 6 A @ 230 V AC1 Minimum load: 1 mA @ 5 V DC1 If consists of one normally open contact with a gap > 3 mm so that the arc length is divided by two. Relays with “Mag. Blow Out” These versions are similar to X types, however they have an addition of a powerful magnet which “blows out” the arc generated when the contacts are opened, therefore quenching the arcing quickly and increasing the contact life. M They are able to switch DC loads of up to 10 A @ 222 V DC1 and 2 A @ 220 V DC13 Remanence Relays A high remanence magnetic circuit allows the relay to latch positively when the current applied flows through the coil in a direction and delatches if the current flows in the opposite direction. R Isolation between contacts: >2000 Vrms Electronic circuitry is added inside the relay to control this action and also protects against transient voltages. The max. DC load is shown in the tables. There is one winding for AC coils and two windings for DC coils. X versions are available in MR-C and QR-C type housing. All coils withstand permanent connection. S Sensitive Relays, 250 mW One change-over contact E Sensitive Relays, 500 mW Two change-over contacts N Sensitive Relays, 800 mW Three change-over contacts High Inrush Current Relay Two open contacts, one of silver nickel and one of tungsten work in parallel but are physically displaced so that the tungsten contact makes and breaks the load. The silver contact is used for carrying the stable current. DC relays adjusted to work at lower power, available in both MR-C and QR-C versions. Gold-flashed contacts 0.2µ or plated 10µ Au (optional). This relay was designed to switch incandescent and fluorescent lamps, (with p.f corrected), and DC inductive loads. Operational voltage range: S relays: 0.8 - 2.5 Un E relays: 0.8 - 1.7 Un N relays: 0.8 - 1.4 Un Only available in C7 type housing. W Maximum loads: 6 A @ 230 V AC5a/b (lamps) 10 A @ 230 V AC15 1.5 A @ 110 V DC1 The relay can be operated with pulses of 50 ms, minimum, at nominal voltage. Specifications The data referred to in the specifications for each model refers to typical values of “new” relays at 20°C. Tables The tables of electrical life and the tables of maximum DC current show the typical result of exhaustive tests performed at an ambient temperature of 20°C, operating frequency of 1,200 operations/hour, and under permanent connection. The switching current ratings specified in the catalog refer to a minimum electrical life of 100,000 operations. Margin of Over-Voltage Coils withstand, on permanent conection, a maximum over-voltage of 110 percent Un, with rated current through the contacts at an ambient temperature of 60°C. Custom Relays Relays with special specifications can be supplied after consultation with an official RELECO distributor. A3 A1 + + A1 A3 A2 A2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 9 General Information Coil Accessories X LED indication with rectifier. For DC and AC relays up to 250 V Surges of 1000 V up to 24 V Surges of 2000 V from 25 to 60 V Surges of 4000 V from 61 to 250 V MRC - QRC Protection Against Transients When the coil is disconnected from an electromagnet, peaks of inverse voltage appear at the terminals which can reach very high values. These pulses can be transmitted down the line associated with the coil and could possibly affect other components. D X LED with no polarity, (standard) Coils ≤12 V CC and CA LED rectifier bridge in parallel X LED with no polarity, (standard) Coils ≥24 V CC and CA LED rectifier bridge in series Free-wheeling diode. DX Free-wheeling diode + LED Dampens transients caused by the relay coil on de-energization. Surges of 2000 V up to 60 VDC Surges of 4000 V from 61 to 250 VDC (*) Transients Carried in the Line High voltage surges can be carried in the supply line to the relay coil. These may appear in the form of peaks or bursts and are generated by the connection and disconnection of electric motors, transformers, capacitors, etc. F Polarity and free wheeling diodes. FX LED with polarity A1+ (option) Every DC coil voltage Polarity and Free-wheeling diodes BX LED with no polarity, (option) Only 24 V and 48 V AC/DC coils Rectifier bridge for AC/DC relays R LED not available (option) Every AC coil voltage RC protection against pulses on AC FX Polarity + free wheeling diode + LED Normally a relay is unaffected by these pulses, but if a diode is connected in association with the coil, it must be capable of withstanding an inverse voltage higher than those of the incoming peaks. Protection Circuits A protection circuit must efficiently cope with pulses generated by the coil as well as incoming line surges (surges U1.2/50µs.). A diode in series with the coil protects the relay from reverse connection. Surges of 1000 V up to 60 VDC Surges of 4000 V from 61 to 250 VDC (*) B Bridge rectifier incorporated. BX Bridge rectifier + LED indication. Allows the relay to operate in both AC or DC without any polarity inconvenience. Available only in voltages up to 60 V Surges of 1000 V R Resistor and capacitor. Suppressor for AC coils. Surges of 2000 V Available only in MRC types (*) Surges of 2000 V in QRC types. X F A1 LED and protection circuit connected to coil. Note: LED connected in series with the coil @ 220 VDC in QRC types. In the case of a relay being operated by such devices as transistors, triacs, etc; it may be necessary to protect against transients. RELECO relays are available with integrated protection circuits or with modules plugged into sockets S3-MP or S3-MS. IRC A1 A2 A2 + If triac, transistor, etc. controls a relay, appropriate steps must be taken to avoid or decrease peaks down to a non-risky level. Both polarity and free-wheeling diodes (FX), must protect coils, to avoid malfunctions, provided DC relays in battery are installed. Making or breaking engines, transformers or contactors in an industrial environmental, may generate high voltage pulses, either isolated or burst, through the main line. The voltage level of those pulse may be high enough to affect the isolation of the coil. FX A1 Protection Against Pulses When a relay coil is disconnected, reverse voltage peaks may arise and reach very high values. Said peaks can transmit to the coil associated line and other relays or semiconductors can be affected. + A2 LED consumption: 1 mA D A1 + A2 Increases release time approx. 4 times DX A1 + B A1 A2 A2 A1 BX A2 BX A1 X ≤ 12 V A1 X ≤ 24 V A1 A2 A1 R A2 A2 Increases release time approx. 4 times Increases release time approx. 3 times FX A2 A1 + R A1 A2 A2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines Bridge Bars Connection on S10-M and S12 Sockets Examples of mounting. Not at scale. New S10-M and S12 sockets and new connection bridges B20, V10 and V40 permit quick and easy wiring for relays in battery, in groups or in any other combination of voltages, coils or contacts. Every bridge allows mounting with a hybrid configuration of S10-M and S12 sockets. The immediate identification of the different circuits means a lower mounting cost, inspection or maintenance. Available in grey (standard), red (AC) and blue (DC), following the same color coding adopted by RELECO in testing buttons to identify its relays. V40 Bridge Bars for Power Lines V10 Bridge Bars for Power Lines V40 bridges allow joining common points in the power connection, usually the change-over contacts 11 or 21 on relays. They can be also used to bridge NC or NO terminals. V10 bridges connect a single socket to the next socket, so can you bridge less or more than four sockets, as long as the total number of sockets is not a multiple of four. V40 bridges join four similar points in four adjacent sockets. They can join among themselves or to V10 units to bridge an unlimited number of sockets in any combination. They can join between themselves or to V40 units. If you need to bridge five sockets, you can either use a V40 + 1 V10 or four V10 bridges. Made of copper with a current capacity of 40 A. Made of copper with a current capacity of 40 A. It is necessary that the total sum of loads in a relay group will not exceed the maximum intensity of 40 A, permitted by the power bridges. If exceeded, the essential power cables must be added, to share the current and avoid overheating the bridges. Every inlet terminal admit ferrule tips up to 4 sq. mm. DC 24 V Power supply for loads at points 1 and 3 1 V10 bridge DC 24 V Power supply for loads at points 1 and 3 AC 230 V Power supply for loads at points 1 and 3 2 V10 bridges 1 V40 bridge 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 2 3 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 22 21 24 22 21 24 22 21 24 22 21 24 9 8 7 9 8 7 9 8 7 9 8 7 1-Pole Relay AC 230 V 1-Pole Relay AC 230 V 2-Poles Relay DC 48 V 2-Poles Relay DC 48 V 2-Poles Relay DC48 V 2-Poles Relay DC 48 V 1-Pole Relay AC 24 V 1-Pole Relay AC 24 V 1-Pole Relay AC 24 V S10-M S10-M S12 S12 S12 S12 S10-M S10-M S10-M 5 6 4 55 66 44 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 A2 A2 A1 A2 A2 A2 A2 A1 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 2 B20 bridges 3 B20 bridges AC 230 V Common DC 48 V Common AC 24 V Common B20 Bridge Bars for Coil Lines Both sockets are accessible to point A2 from terminals 5 and 6, internally connected. Each element connects point 6 of the first socket to point 5 of the next one, always leaving free the point 5 of the first socket and the point 6 of the last one, to connect the common polarity cable. Coils control voltage connect to points A1. Bridge B20 is composed by four units which can be divided in 1, 2 or 3 elements. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 11 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines V40 V10 B20 Power Bridge Bars for Sockets Coil Bridge Bars for Sockets S10-M and S12 S10-M and S12 V40 bridges join four similar points in four adjacent sockets. They can join among themselves or to V10 units to bridge an unlimited number of sockets S10-M and S12 in any combination. B20 bridges points A2, internally connected, of every adjacent socket S10-M or S12. V10 bridges connect a single socket to the next socket, so you bridge less or more then four sockets. Each element connects point 6 of the first socket to point 5 of the next one, always leaving free the point 5 of the first socket and the point 6 of the last socket, to connect the common polarity cable. Made of copper with a current capacity of 40 A. See more information on page 11. See more information on page 11. V40-G V10-G B20-G V40-R V10-R B20-R V40-A V10-A B20-A IEC 61810 EN 60947 IRC relays, E version Types C14... and C15... Cover for flange panel mounting Ordering code: Add “E” to the standard type code. Example: C14-A10E or C15-A21E Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface Applications Total Interconnection, Bridge Bars for Coil and Power Lines I/O sockets, IRC relays and bridge bars allow more flexible, economical and aesthetic mounting in interface and general applications. S10-M and S12 sockets of 1 and 2 contacts, with inlets in line and identical disposition of contacts set. Identical sequence of coil and contacts on both sockets. Coil terminal on level 1: Contact terminals on level 1: Contact terminals on level 2: (A2, A2, A1) (12, 11, 14) (22, 21, 24) Bridge bars between A2 coil terminals with 2 free inlets to connect a commom polarity cable. Those bridge bars are isolated and divisible by hand, in single units. Power bridges with current capacity of 40 A to be connected between contacts 11 or 21 in any combination: Groups or battery of relays, to supply the power current to the loads. Inlet terminals admit ferrule tips up to 4 mm2. Common Polarity Cable for Coils Bridges in grey color as standard. Options: Adopted colors by RELECO used in the testing buttons of relays: Blue, to identify DC circuits Red, to identify AC circuits B20 Bridge Bars for Coil Line V40 and V10 Bridge Bars for Power Line Common Power Supply Cable for Loads Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 13 IRC Interface Applications Total Interconnection, Solid State Relays How to Mount Solid State Relays as Interface on PLC Input In every CSS relay, the input on terminals A1 and A2 is 5-32 VDC, with no polarity. Output on DC (Relays in Battery) If power bridges are used with S10-M sockets in series of relays in line, it is necessary to attend the common polarity chosen to the loads connection. If bridges to joint points A2 are used, a single voltage can be applied on terminals A1, for every relay, or different voltages within the range 5-32 VDC. Usually the point 2 (11 DIN) is the common point of the socket where positive tension is applied to the loads. Output DC or AC (Independent Relays) When using a single relay of any model, load can be connected either on terminal 1 or terminal 2. Then CSS-DCP relays must be connected where terminal 2 is common positive. Said disposition complies Norm EN-60204-1-5,3,3 where “cutting every active element of its feeding” is suggested, that means to switch from the positive. Relays with Output on DC (CSS-DCP or CSS-DCN). Range of voltage applied to the load will be 5-50 VDC. Relays with Output on AC (CSS-AC, Inductive Loads, or CSS-AZ, Resistive Loads). Range of voltage applied to the load will be 24-250 VAC, 50/60 Hz. If point 2 of the socket is taken as negative, relays type CSSDCN, where terminal 2 is negative must be connected. For relays CSS-AC or CSS-AZ, only whether the load is inductive or resistive has to be considered, as they have no polarity. PLC Input Terminals 5 - 50 VDC Load 2 Load 1 Load 3 Input 1 5 - 50 VDC + Input 2 Input 3 + 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 3 2 1 2 3 1 2 3 2 3 1 1 2 3 1 2 3 1 CSS-DCP CSS-DCP CSS-DCP CSS-DCP C10-T13X CSS-DCP S10-M S10-M S10-M S10-M S10-M S10-M 5 6 4 5 6 4 5 6 5 4 6 4 5 6 4 5 6 4 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 ± 5 - 32 VDC Out 1 Out 3 Out 2 24 VDC ± PLC Output Terminals Load 1 2A Ind. 24 - 250 VAC Sensor PNP Switch Sensor PNP + Load 2 3A Res. Load 3 3A Ind. Load 4 3A Res. Load 5 3A Ind. Load 6 10A Res. Load 7 6A Res. Load 8 3A Ind. 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 12 11 14 3 5 2 1 3 2 1 2 3 1 3 2 1 2 3 1 3 2 1 3 2 1 3 2 1 SS-AC CSS-AZ CSS-AC CSS-AZ C10-A10X C10-A10X C10-A10X CSS-AC S10-M S10-M S10-M S10-M S10-M S10-M S10-M S10-M 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 A2 A2 A1 ± 24 VDC Out 1 Out 2 Out 3 ± Out 4 Out 5 Out 6 Out 7 Out 8 PLC Output Terminals Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 14 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 RELAYS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 15 MRC 2-Pole, Standard 8-Pin Plug-In Relay C2-A20 General purpose Two pole, change-over contacts Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S2-B, S2-S, S2-L, S2-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: Table 1 4 3 5 6 2 12 14 22 24 A1 (+) 11 21 A2 1 8 7 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Ω VAC mA AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA ≤0.8 x Un ≥0.1 x Un 2.2 VA (AC)/1.3 W (DC) VDC Ω mA 24 67 92 24 433 54 48 296 46 48 1K8 27 115 1K7 19 110 9K2 12 230 7K1 9.5 220 36K1 6 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relay Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C2-A20X ........VAC RC suppressor C2-A20R........VAC DC 24, 48, 110, 220 X = LED, no polarity (standard) C2-A20X ....... VDC Free-wheeling diode C2-A20DX .... VDC Polarity and free-wheeling diodes C2-A20FX..... VDC AC/DC bridge rectifier (24, 48 or 60 V) C2-A20BX .... VDC 1 8 A1 3 6 58.5 35 2 7 A2 5 4 35 Lloyd´s IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 16 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 2-Pole, Twin Contacts 8-Pin Plug-In Relay C2-T21 Low level Two change-over bifurcated contacts Relay compatible with sockets: 6 A 250 V AC1 6 A 30 V DC1 Min. contacts load: 1 mA / 5 V DC1 S2-B, S2-S, S2-L, S2-PO Contacts Materials: 4 3 5 6 2 12 14 22 24 A1(+) 11 21 A2 1 8 7 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Amps. AC1 AC1 1 250 500 750 VA 1000 Table 2 ≤0.8 x Un ≥0.1 x Un 2.2 VA (AC)/1.3 W (DC) VAC Ω mA VDC Ω mA 24 67 92 24 433 54 48 296 46 48 1K8 27 115 1K7 19 110 9K2 12 230 7K1 9.5 220 36K1 6 Insulation 0.1 0 AgNi + 0.3µAu AgNi + 10µAu 6A 15 A 250 V 1.2 KVA 1250 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relay Electrical life at nominal load 100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C2-T21X ........VAC RC suppressor C2-T21R ........VAC 1 8 A1 DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 3 6 58.5 35 2 7 A2 5 4 35 C2-T21X ....... VDC C2-T21DX..... VDC C2-T21FX ..... VDC C2-T21BX..... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 17 MRC 2-Pole, Standard 8-Pin Plug-In Relay C2-G20 General purpose, DC applications Two pole open contacts Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S2-B, S2-S, S2-L, S2-PO 1.2 A 110 V DC1 0.4 A 220 V DC1 Contacts 3 6 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 2 A1(+) Gap 1.7 mm A2 1 Table 1 AgNi 10 A 30 A 250 V 2.5 KVA 8 7 Coils (Ohms ±10% @ 20°C) Electrical Life, ops. x 106 Pull-in voltage Drop-out voltage Nominal coil power ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.6 W (DC) VAC Ω mA VDC Ω mA 24 65 100 24 360 66 48 286 50 48 1K4 34 115 1K7 21 110 7K6 15 230 6K8 10 220 30K3 7.5 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, EN 61810-5: Max. DC Load 2,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C2-G20X........VAC RC suppressor C2-G20R .......VAC 1 8 A1 DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 3 6 58.5 35 2 7 A2 5 4 35 C2-G20X....... VDC C2-G20DX .... VDC C2-G20FX .... VDC C2-G20BX .... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 18 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 3-Pole, Standard 11-Pin Plug-In Relay C3-A30 General purpose Three pole, change-over contacts Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 0.5 A 110 V DC1 0.5 A 220 V DC1 Contacts Materials: 4 3 5 7 8 9 2 12 14 22 24 32 34 A1(+) 11 21 31 A2 1 6 11 10 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 0.1 0.5 1 1.5 KVA Table 2 2 mA VDC Ω mA 24 67 92 48 296 46 24 433 54 48 1K8 27 115 1K7 19 230 7K1 9.5 110 9K2 12 220 36K1 6 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 DC1 L/R 40ms DC13 Amps. ≤0.8 x Un ≥0.1 x Un 2.2 VA (AC)/1.3 W (DC) Ω VAC 1 AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load 100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 11 A1 9 DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 4 35 3 8 58.5 2 10 A2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C3-A30X ........VAC RC suppressor C3-A30R........VAC 7 6 5 35 Lloyd´s C3-A30X ....... VDC C3-A30DX .... VDC C3-A30FX..... VDC C3-A30BX .... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 19 MRC 3-Pole, Twin Contacts 11-Pin Plug-In Relay C3-T31 Low leveL Three change-over bifurcated contacts Relay compatible with sockets: 6 A 250 V AC1 6 A 30 V DC1 Min. contacts load: 1 mA / 5 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO Contacts Materials: 4 3 5 7 8 9 2 12 14 22 24 32 34 A1(+) 11 21 31 A2 1 6 11 10 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (15 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Electrical Life, ops. x 106 Table 1 Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 AC1 0 250 500 750 VA Table 2 1000 Ω mA VDC Ω mA 24 67 92 24 443 54 48 296 46 48 1K8 27 115 1K7 19 110 9K2 12 230 7K1 9.5 220 36K1 6 Insulation 1250 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications AC1 Amps. ≤0.8 x Un ≥0.1 x Un 2.2 VA (AC)/1.3 W (DC) VAC 1 0.1 AgNi + 0.3µAu AgNi + 10µAu 6A 15 A 250 V 1.2 KVA Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 11 A1 9 DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 4 35 3 8 58.5 2 10 A2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C3-T31X ........VAC RC suppressor C3-T31R ........VAC 7 6 5 35 C3-T31X ....... VDC C3-T31DX..... VDC C3-T31FX ..... VDC C3-T31BX..... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 3-Pole, Standard 11-Pin Plug-In Relay C3-G30 General purpose, DC applications Three pole, open contacts Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 1.2 A 110 V DC1 0.4 A 220 V DC1 Contacts 3 9 7 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 2 A1(+) AgNi 10 A 30 A 250 V 2.5 KVA A2 1 Table 1 6 10 11 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 1 0.1 0.5 1 1.5 KVA Table 2 2 VAC Ω mA VDC Ω mA 24 65 100 24 360 66 34 48 286 50 48 1K4 115 1K7 21 110 7K6 15 230 6K8 10 220 30K3 7.5 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 L/R 40ms Amps. ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.6 W (DC) 2,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 11 A1 9 DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 4 35 3 8 58.5 2 10 A2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C3-F30X ........VAC RC suppressor C3-G30R .......VAC 7 6 5 35 C3-G30X....... VDC C3-G30DX .... VDC C3-G30FX .... VDC C3-G30BX .... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 21 MRC C3-M10 Power relay, DC Single pole, magnetic blow out Relay compatible with sockets: 10 A 250 V AC1 3.6 A 110 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 10 A 220 V DC1 2 A 220 V DC1 Contacts 3 9 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage (pollution 3) Max. switching voltage (pollution 2) Max. AC load (Table 1) Max. DC load (Table 2) 2 A1(+) A2 Gap > 3 mm (1.7+1.7) 10 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. AC1 AC1 AC15 AC15 1 1.5 mA VDC Ω mA 65 100 24 443 54 48 286 50 48 1K7 27 115 1K7 21 110 9K2 12 230 6K8 10 220 36K1 6 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: KVA Max. DC Load 10 DC1 110V DC1 220V Ops. Ω 24 Insulation 0.1 0.5 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.3 W (DC) VAC 1 Table 2 AgNi 10 A 30 A 250 V 250 V 2.5 KVA 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications Nominal coil power 2.4 VA (AC), 1.3 W (DC) Operate time 20 ms Release time 10 ms Isolation: EN60947 pollution 3, Gr C 250 V Dielectric strength, contacts/coils 2.5 KV 1 0.1 2 4 6 Amp 8 10 Standard Types (50/60 Hz and DC) Dimensions - mm 1 11 A1 9 4 35 C3-M10X .......VAC C3-M10R .......VAC DC 24, 48, 110, 220 X = LED, no polarity (stardard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C3-M10X ...... VDC C3-M10DX .... VDC C3-M10FX .... VDC C3-X10BX .... VDC 3 8 58.5 2 10 A2 AC 24, 48, 115, (120), 230 X = LED (stardard) RC suppressor 7 6 5 35 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 22 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 1-Pole, Standard 11-Pin Plug-In Relay C3-X10 Power relay for DC applications Single pole, N.O., double make Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 7 A 110 V DC1 1.2 A 220 V DC1 Contacts 3 9 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 2 A1(+) AgNi 10 A 30 A 250 V 2.5 KVA A2 Gap > 3 mm (1.7+1.7) Table 1 10 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 1 1 1.5 KVA Table 2 2 2.5 Ω mA VDC Ω mA 24 65 100 24 443 54 48 286 50 48 1K7 27 115 1K7 21 110 9K2 12 230 6K8 10 220 36K1 6 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 L/R 40ms Amps. VAC Insulation 0.1 0.5 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.3 W (DC) 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP40 / RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 11 A1 9 DC 24, 48, 110, 220 X = LED, no polarity (stardard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 4 35 3 8 58.5 2 10 A2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C3-X10X ........VAC RC suppressor C3-X10R ........VAC 7 6 5 35 C3-X10X ....... VDC C3-X10DX .... VDC C3-X10FX ..... VDC C3-X10BX .... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 23 MRC 2-Pole, Latching 11-Pin Plug-In Relay C3-R20 Magnetic latching Two change-over contacts Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: 4 3 8 9 2 6 12 14 22 24 A1 A3 ON (+) OFF (+) 11 21 A2 (-) 1 11 10 Table 1 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils Electrical Life, ops. x 106 ON pulse power OFF pulse power One winding for AC. Two winding for DC 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 VAC 1 0.1 0.5 1 1.5 KVA Table 2 2 ON mA OFF mA VDC 1.5 VA / W 0.5 VA / W ON mA OFF mA 24 75 12 12 125 41 48 38 6 24 63 21 115 16 2.5 48 31 10 230 8 1.3 110 14 4.5 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 DC1 L/R 40ms DC13 Amps. AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications Minimum pulse length for ON / OFF 50 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm A1 9 C3-R20 ......... VDC 4 35 DC 12, 24, 48, 110 3 8 58.5 2 10 A2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) C3-R20 ..........VAC 1 11 7 6 5 35 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 24 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 3-Pole, Standard 11-Pin Plug-In Relay C3-E24 Sensible, 500 mW Two change-over contacts, 6 A Operating range: 0.8-1.7 x Un Relay compatible with sockets: 6A S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 250 V AC1 6A 30 V DC1 Contacts Materials: Table 1 4 3 8 9 2 12 14 22 24 A1(+) 11 21 A2 1 11 10 Standard, code 4 Optional, code 8 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 10 Ops. AC1 1 1 1.5 Max. DC Load 10 mA 1K1 21 48 4K6 10 60 7K2 8.3 110 24K2 4.5 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications DC1 Amps. Ω 24 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: KVA Table 2 VDC ≤0.8 x Un ≥0.1 x Un 500 mW Insulation 0.1 0.5 AgNi + 0.2µ Au AgNi + 10µ Au 6A 15 A 250 V 1.5 KVA Operate time + bounce time 18 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +60°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm DC 12, 24, 48, 60, 110 A1 9 C3-E24D ....... VDC C3-E24F ....... VDC 4 35 Free-wheeling diode Polarity and free-wheeling diodes 3 8 58.5 2 10 A2 C3-E24 ......... VDC 1 11 7 6 5 Connecting diodes to the coil will increase the release time. LED available upon request. 35 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 25 MRC 3-Pole, Standard 11-Pin Plug-In Relay C3-N34 Sensitive, 800 mW Three change-over contacts, 6 A Operating range: 0.8-1.4 x UN Relay compatible with sockets: 6A S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 250 V AC1 6A 30 V DC1 Contacts 4 3 5 7 8 9 2 12 14 22 24 32 34 A1(+) 11 21 31 A2 1 6 11 10 Table 1 Materials: Standard, code 4 Optional, code 8 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 10 Ops. AC1 Ω mA 24 720 33 48 2K8 17 60 4K5 13 110 15K 7 1 1.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: KVA Table 2 ≤0.8 x Un ≥0.1 x Un 800 mW Insulation 0.1 Max. DC Load 10 1,000 V 2.5 KV 2.5 K ≥3 GΩ 2.5 KV / 3 Specifications DC1 Amps. VDC 1 0.5 AgNi + 0,2µ Au AgNi + 10µ Au 6A 15 A 250 V 1.5 KVA Operate time + bounce time 18 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +60°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm DC 24, 48, 60, 110 A1 9 C3-N34D....... VDC C3-N34F ....... VDC 4 35 Free-wheeling diode Polarity and free-wheeling diodes 3 8 58.5 2 10 A2 C3-N34 ..........VAC 1 11 7 6 5 Connecting diodes to the coil will increase the release time. LED available upon request. 35 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 26 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 3-Pole Relay, 11-Pin Plug-In Railway Relay R3-N30D Railway Application Relay According to EN 60077-1-2/99 EN 61373/99 Relay compatible with sockets: 6A S3-B, S3-S, S3-MP, S3-MS, S3-L, S3-PO 250 V AC1 6A 30 V DC1 Contacts Materials: 4 3 5 7 8 9 2 12 14 22 24 32 34 A1(+) Table 1 11 21 31 A2 1 6 11 10 Standard, code 0 Optional, code 4 Optional, code 8 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Electrical Life, ops. x 106 Coils Operation Range Power Consumption Generated transients 10 Ops. AC1AC1 CosAC15 Phi 0.4 Voltage 1 0.1 250 1000 Table 2 1500 VA 2000 AgNi AgNi + 0.2µ Au AgNi + 10µ Au 6A 15 A 250 V 2500 Ω ± 10% 0.7 Un @ 1.25 Un 1.07 W V, include FWD mA 24 525 46 48 2150 22 72 4930 15 110 12900 9 Isolation Polution grade PD3 With voltage (1.2/50µs) / Dielectric strength (1 minute): Contact coil 4 KV/2220 V Between different poles 4 KV/2220 V Between contacts on same pole 1550 KV/850 V Electrical Life, ops. x 106 10 DC1 4R 40ms Ops. Specifications Max working temperature Number of mechanical operations Thermic Class Vibration: Category/Class Vibration Shock Operation (UN)/release time Weight avg. Weight avg. Relay + Socket Relay Protection 1 0.1 25 100 175 22 Volts Dimensions - mm 1 11 9 DC 24, 48, 72, 110 4 3 35 2 8 58.5 Standard Types A1 10 A2 7 6 40°C >10 million B (130°C) 1/B Body Mounted 5-150 Hz (3 axes) 5 g (3 axes) 18 ms/35 ms 95 g 150 g IP 40 X = LED Free-wheeling diode LED and free-wheeling diode 5 35 R3-N30 ......... VDC R3-N30X ....... VDC R3-N30D....... VDC R3-N30DX .... VDC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 27 MRC 4-Pole, Square Base, Plug-In Relay C4-A40 General purpose Four change-over contacts Relay compatible with sockets: 10 A 250 V AC1 6 A 30 V DC1 S4-B, S4-L, S4-P, S4-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: 1 2 4 5 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 13 7 8 10 11 12 14 22 24 32 34 42 44 A1(+) 11 21 31 41 A2 3 6 9 12 14 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 1 0.1 0.5 1 1.5 KVA Table 2 2 mA 24 65 100 48 286 50 115 1K7 21 230 6K8 10 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.4 W (DC) Ω mA 24 414 58 48 1K6 30 110 8K1 13 220 35K7 6.2 VDC Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 DC1 L/R 40ms DC13 Amps. Ω VAC AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Specifications Operate time + bounce time 20 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 4 35 2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C4-A40X ........VAC RC suppressor C4-A40R........VAC 48 107 10 11 11 9 9 7 5 6 3 12 13 14 35 DC 24, 48, 110, 220 X = LED no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 35 3 C4-A40X ....... VDC C4-A40DX .... VDC C4-A40FX..... VDC C4-A40BX .... VDC Lloyd´s IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 28 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 2-Pole, Square Base, Plug-In Relay C4-X20 Power relay, DC applications Two pole, N.O., double make Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S4-B, S4-L, S4-P, S4-PO 5 2 8 Contacts Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 13 11 7 A @ 110 V DC1 1.2 A @ 220 V DC1 A1 (+) AgNi 10 A 30 A 250 V 0.5 KVA A2 Gap > 3 mm (1.7+1.7) 14 Coils (Ohms ±10% @ 20°) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 1 0.1 0.5 1 1.5 KVA 2 Table 2 VAC Ω mA VDC Ω mA 24 65 100 24 414 54 48 286 50 48 1K8 27 115 1K7 21 110 9K2 12 230 6K8 10 220 36K1 6 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 L/R 40ms Amps. ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.3 W (DC) 2,500 V 2.5 KV 2.5 KV ≤1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 12 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 1 4 35 2 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C4-X20X ........VAC RC suppressor C4-X20R ........VAC 48 107 10 11 11 9 9 7 5 6 3 12 13 14 35 DC 24, 48, 110, 220 X = LED no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V)) 35 C4-X20X ....... VDC C4-X20DX .... VDC C4-X20FX ..... VDC C4-X20BX .... VDC 3 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 29 MRC 3-Pole, Square Base, Plug-In Relay C4-R30 Magnetic latching relay Three change-over contacts, 10 A Relay compatible with sockets: 10 A 250 V AC1 10 A 10 V DC1 S4-B, S4-L, S4-P, S4-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: 4 5 1 2 7 8 12 14 22 24 32 34 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 13 12 A1 A3 ON (+) OFF (+) 11 21 31 A2 (-) 3 6 9 14 Electrical Life, ops. x 106 Table 1 Coils 10 ON pulse power OFF pulse power One winding for AC, Two windings for DC AC1 AC1 ϕ 0.4 Cos AC15 Ops. AgNi AgNi + 10µAu AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA VAC 1 ON mA OFF mA VDC 1.5 VA / W 0.5 VA / W ON mA OFF mA 24 75 12 12 125 41 48 38 6 24 63 21 115 16 2.5 48 31 10 230 8 1.3 110 14 4.5 0.1 0.5 1 1.5 KVA Table 2 2 2.5 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV / 3 Amps. DC1 DC1 L/R 40ms DC13 Specifications Minimun, pulse length for ON / OFF 50 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Dimensions - mm Standard Types 1 4 52.5 35 2 7 5 AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) C4-R30 ..........VAC 10 11 8 6 9 3 12 13 14 DC 12, 24, 48, 110 35 8 3 FASTON .110 C.I. C4-R30 ......... VDC 8 3.85 6.5 7.0 6.75 1.2 8 ø1.5 6.75 4.15 IEC 61810 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 30 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 2-Pole, Square Base, Plug-In Relay C5-A20 General purpose Two change-over contacts Relay compatible with sockets: 16 A 400 V AC1 16 A 30 V DC1 S5-S, S5-L, S5-P, S5-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: 1 4 3 6 A 12 14 22 24 A1(+) 11 21 A2 7 9 B Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 Cos ϕ 0.4 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.4 W (DC) Ω mA VDC 24 65 100 48 286 50 115 1K7 230 6K8 VAC 1 AgNi AgNi + 10µAu AgNi + 0.2µ Au 16 A 40 A 400 V 4 KVA Ω mA 24 414 58 48 1K6 30 21 110 8K1 13 10 220 35K6 6 0.1 0.66 1.33 2 KVA Table 2 2.6 3.3 4 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 16 10 1,000 V 4 KV 4 KV ≥3 GΩ 4 KV/3 Amps. DC1 L/R 40ms Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 50 100 150 200 Volts Dimensions - mm 56 35 Standard Types 1 2 3 4 7 5 8 6 9 A AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240), 400 X = LED (standard) C5-A20X ........VAC RC suppressor C5-A20R........VAC B DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 35 11.05 11.05 4.75 FASTON .187 4.6 5.5 8.3 7.7 1.3 C.I. C5-A20X ....... VDC C3-A20DX .... VDC C5-A20FX..... VDC C5-A20BX .... VDC ø1.5 8.9 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 31 MRC 3-Pole, Square Base, Power Relay C5-A30 General purpose Three change-over contacts Relay compatible with sockets: 16 A 400 V AC1 16 A 30 V DC1 S5-S, S5-L, S5-P, S5-PO 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts 1 4 2 5 3 6 A 12 14 22 24 32 34 A1(+) 11 21 31 A2 7 8 9 B Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Res Cos ϕ 0.4 Ω Ops. VAC 24 48 115 230 400 1 0.1 0.66 1.33 2 KVA 2.6 3.3 65 286 1K7 6K8 18K8 AgNi 16 A 40 A 400 V 4 KVA ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.4 W (DC) mA VDC 100 50 21 10 6 24 48 110 220 Ω 414 1K6 8K1 35K6 mA 58 30 13 6.5 4 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 16 10 1,000 V 4 KV 4 KV ≥3G Ω 4 KV/3 Amps. DC1 L/R 40ms Specifications 1 Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 0.1 50 100 150 200 Volts 56 35 Dimensions - mm 1 2 3 4 7 5 8 6 9 A Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C5-A30X ........VAC RC suppressor C5-A30R........VAC B DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 35 11.05 11.05 4.75 FASTON .187 4.6 5.5 8.3 7.7 1.3 C.I. C5-A30X ....... VDC C3-A30DX .... VDC C5-A30FX..... VDC C5-A30BX .... VDC ø1.5 8.9 IEC 6094 IEC 61810 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 32 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 3-Pole, Square Base, Power Relay C5-G30 General purpose, DC applications Three open contacts Relay compatible with sockets: 16 A 400 V AC1 16 A 30 V DC1 S5-S, S5-L, S5-P, S5-PO 1.2 A 110 V DC1 0.4 A 220 V DC1 Contacts 5 4 6 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) A A1(+) A2 Gap 1.7 mm 8 7 9 B Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) 10 Pull-in voltage Drop-out voltage Nominal coil power AC1 Cos ϕ 0.4 Ω Ops. VAC 24 48 115 230 400 1 0.1 0.66 1.33 2 KVA AgNi 16 A 40 A 400 V 4 KVA 2.6 3.3 65 286 1K7 6K8 18K8 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.6 W (DC) mA VDC 100 50 21 10 6 12 24 48 110 220 Ω 90 360 1K4 7K6 30K3 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 16 10 DC1 L/R 40ms Amps. 133 66 34 15 7.5 4 Insulation Table 2 mA ≥2,000 V 4 KV 4 KV ≥3 GΩ 4 KV/3 Specifications 1 Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 0.1 50 100 150 200 Volts 56 35 Dimensions - mm 1 2 3 4 7 5 8 6 9 A Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C5-G30X........VAC RC suppressor C5-G30R .......VAC B DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 35 11.05 11.05 4.75 FASTON .187 4.6 5.5 8.3 7.7 1.3 C.I. C5-G30X....... VDC C3-G30DX .... VDC C5-G30FX .... VDC C5-G30BX .... VDC ø1.5 8.9 IEC 60947 IEC 61810 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 33 MRC 1-Pole, Square Base, Power Relay C5-X10 Power relay, DC applications Single pole, N.O., double make Relay compatible with sockets: 16 A 400 V AC1 16 A 30 V DC1 S5-S, S5-L, S5-P, S5-PO 7 A 110 V DC1 1.2 A 220 V DC1 Contacts 6 4 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) A A1(+) A2 Gap > 3 mm (1.7+1.7) mm B Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 AC1 Cos ϕ 0.4 Ω Ops. VAC 24 48 115 230 400 1 0.1 0.66 1.33 AgNi 16 A 40 A 400 V 4 KVA 2 KVA 2.6 3.3 65 286 1K7 6K8 18K8 ≤0.8 x Un ≥0.1 x Un 2.4 VA (AC)/1.3 W (DC) mA VDC 100 50 21 10 6 12 48 48 110 220 Ω 110 443 1K8 9K 34K5 mA 108 54 27 12 6.5 4 Insulation Table 2 Dielectric strength (1 minute): Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 16 10 Amps. DC1 L/R 40ms 4 KV 4 KV ≥3 GΩ 4 KV/3 Specifications 1 Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 0.1 50 100 150 200 Volts 56 35 Dimensions - mm 1 2 3 4 7 5 8 6 9 A Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C5-X10X ........VAC RC suppressor C5-X10R ........VAC B DC 24, 48, 110, 220 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 35 11.05 11.05 4.75 FASTON .187 4.6 5.5 8.3 7.7 1.3 C.I. C5-X10X ....... VDC C5-X10DX .... VDC C5-X10FX ..... VDC C5-X10BX .... VDC ø1.5 IEC 61810 8.9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 34 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 1-Pole, Square Base, Power Relay C5-M10 DC power relay One N.O. pole, magnetic blow out Relay compatible with sockets: 16 A 400 V AC1 3.6 A 110 V DC Ind S5-S, S5-L, S5-P, S5-PO 10 A 220 V DC1 2 A 220 V DC Ind Contacts 4 (+) 6 Magnet Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) A A1(+) A2 Gap > 3 mm (1.7+1.7) mm B Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Res Cos ϕ 0.4 Ω Ops. VAC 24 48 115 230 400 1 0.1 0.66 1.33 AgNi 16 A 40 A 400 V 4 KVA 2 KVA 2.6 3.3 65 286 1K7 6K8 18K8 ≤0.8 x Un ≥0.1 x Un 2.4 VA (CA)/1.3 W (CC) mA VDC 100 50 21 10 6 12 48 48 110 220 Ω 110 443 1K8 9K 34K5 mA 108 54 27 12 6.5 4 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, EN 60947/IEC 61810-5: Max. DC Load 10 Ops. DC1 110V DC1 220V 4,000 V 4 KV ≥3 GΩ 4 KV/3 Specifications 1 Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC relays, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 0.1 2 4 6 Amp 8 10 Dimensions - mm Standard Types (50 / 60 Hz and CC) 35 1 4 7 A 2 3 1 2 5 6 4 5 8 9 8 A 35 B 35 AC 24, 48, 115, (110 - 120), 230 X = LED (standard) RC suppressor C5-M10X .......VAC C5-M10R .......VAC DC 12, 24, 48, 110, 120/125,220 X = LED Free-wheeling diodes Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C5-M10X ...... VDC C5-M10DX .... VDC C5-M10FX .... VDC C5-M10BX .... VDC 4.75 FASTON .187 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 35 MRC 2-Pole, Square Base, Power Relay C5-M20 Power relay, DC Double pole, N.O., magnetic blow out Relay compatible with sockets: 16 A 250 V AC1 7A 3A S5-S, S5-L, S5-P, S5-PO 110 V DC1 220 V DC1 Contacts 4 (+) 6 Magnet Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) A A1(+) 7 (+) AgNi 16 A 40 A 250 V 4 KVA A2 9 (+) B Gap 1.7 mm Coils (Ohms ±10% @ 20°C) Electrical Life, ops. x 106 Table 1 Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 Cos ϕ 0.4 VAC Ω mA VDC Ω mA 24 65 100 12 90 133 48 286 50 24 360 66 115 1K7 21 48 1440 33 230 6K8 10.4 110 7K6 15 1 0.1 0.66 1.33 2 KVA Table 2 2.6 3.3 0.8 x Un 0.1 x Un 2.4 VA (CA) / 1.6 W (CC) Insulation 4 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, EN 60947/IEC 61810-5: Max. DC Load 10 DC1 L/R 40ms 2 KV 4 KV 3 KV ≥3 GΩ 4 KV/3 Ops. Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +60°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥75,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 90 g 1 0.1 0 50 100 150 250 200 Amps. Dimensions - mm Standard Types (50 / 60 Hz and CC) 35 1 4 7 A 2 3 1 2 5 6 4 5 8 9 8 A 35 B 35 AC 24, 48, 115, (120), 230 (240) X = LED (standard) RC suppressor C5-M20X .......VAC C5-M20R .......VAC DC 12, 24, 48, 110, 120/125, 220 X = LED Free-wheeling diodes Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C5-M20X ...... VCC C5-M20DX .... VCC C5-M20FX .... VCC C5-M20BX .... VCC 4.75 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 36 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC 2-Pole, Latching Relay C5-R20 Magnetic latching relay Two Change-over contacts, 10 A Relay compatible with sockets: 10 A 400 V AC1 0.2 A 220 V DC1 S5-S, S5-L, S5-P, S5-PO 10 A 30 V DC1 0.5 A 110 V DC1 Contacts 1 4 3 6 12 14 22 24 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) A 8 A1 A3 ON (+) OFF (+) 11 21 A2 (-) 7 9 B Coils (Ohms ±10% @ 20°C) ON pulse power OFF pulse power One winding for AC, two windings for DC Electrical Life, ops. x 106 Table 1 10 Ops. AC1 AC1 ϕ 0.4 Cos AC15 VAC 1 0.1 0.5 1 1.5 KVA Table 2 2 AgNi 10 A 30 A 400 V 4 KVA ON mA OFF mA VDC 1.5 VA/W 0.5 VA/W ON mA OFF mA 24 75 12 12 125 41 48 38 6 24 63 21 115 16 2.5 48 31 10 230 8 1.3 110 14 4.5 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, EN 60947/IEC 61810-5: Max. DC Load 10 1,000 V 4 KV 4 KV ≥3 GΩ 4 KV/3 Amps. DC1 DC1 L/R 40ms DC13 Specifications Minimun, pulse length for ON / OFF 50 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 95 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm 35 1 4 7 A AC 50 Hz, (60 Hz): 24, 48, 115, (110-120), 230, (240) C5-R20 ..........VAC 2 3 1 2 5 6 4 5 8 9 8 A 35 DC 12, 24, 48, 110 C5-R20 ......... VDC B 35 4.75 IEC 61810 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 37 QRC 1-Pole, Miniature Power Plug-In Relay C7-A10 General purpose One change-over contact, 16 A Relay compatible with sockets: 16 A 250 V AC1 16 A 30 V DC1 S7-16 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts 1 4 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Only plug-in S7-16 socket 7 A1 (+) AgNi 16 A 40 A 250 V 4 KVA A2 5 8 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. Res AC1 Cos ϕ 0.4 VAC Ω mA VDC Ω mA 24 174 50 12 111 108 1 0.1 0 250 500 750 VA Table 2 1000 ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1.3 W (DC) 48 686 25 24 432 55 115 4K3 10.4 48 1K7 28 230 18K6 5.2 110 9K2 12 Insulation 1250 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 1,000 V 2.5 KV ≥1 GΩ 2.5 KV/3 16 10 Specifications Amps. DC1 L/R 40ms Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C7-A10X ........VAC 1 2 3 5 4 6 7 A 8 B DC 12, 24, 48, 110, X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C7-A10X ....... VDC C7-A10DX .... VDC C7-A10FX..... VDC C7-A10BX .... VDC 21 4.75 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC 2-Pole, Miniature Power Plug-In Relay C7-A20 General purpose Two pole, change-over contacts Relay compatible with sockets: S7-M, S7-L, S7-P, S7-PO, S7-PI 10 A 250 V AC1 10 A 30 V DC1 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: Table 1 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 10 Ops. Res Cos ϕ 0.4 Ω VAC 24 48 72 115 230 1 174 686 1587 4K3 18K6 AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1 W (DC) mA VDC 50 25 17 10.4 5.2 12 24 48 72 110 Ω 148 594 2k3 5089 11K4 mA 85 43 21 14.1 11 0.1 0.5 1 1.5 KVA Table 2 2 2.5 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Amps. DC1 Res L/R 40ms DC13 Specifications Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 200 Volts Dimensions - mm Standard Types 1 2 3 5 4 6 7 A 8 B AC 50 Hz, (60 Hz): 24, 48, 72, 115, (120), 230, (240) X = LED (standard) C7-A20X ........VAC DC 12, 24, 48, 72, 110, X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 21 C7-A20X ....... VDC C7-A20DX .... VDC C7-A20FX..... VDC C7-A20BX .... VDC 4.75 Lloyd´s FASTON .187 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 39 QRC 2-Pole, Miniature Power Plug-In Relay C7-A20E General purpose Two pole Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-PI 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Standard, code 0 Optional, code 8 Optional, code 9 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20ºC) AC1 Cos ϕ 0.4 Ops. ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1 W (DC) Pull-in voltage Drop-out voltage Nominal coil power 10 1 AgNi AgNi + 10µ Au AgNi + 0.2µ Au 10 A 30 A 250 V 2.5 KVA VAC Ω mA VDC Ω mA 24 174 50 12 148 85 48 686 25 24 594 43 115 4K3 10.4 48 2K3 21 230 18K6 5.2 110 11K4 11 0.1 0.5 1 1.5 KVA Table 2 2 2.5 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Amps. DC1 DC1 L/R 40ms DC13 Specifications Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 1,000 V 2.5 KV 2.5 KV ≥3 GΩ 2.5 KV/3 200 Volts Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) C7-A20E ........VAC C7-A20E ....... VDC 38 34.7 28 DC 12, 24, 48, 110 21 4.75 Lloyd´s IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 40 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC 2-Pole, Twin Contact Miniature Power Plug-In Relay C7-T21 Low level Two change-over bifurcated contacts Relay compatible with sockets: 6 A 250 V Res 6 A 30 V DC1 Min. contacts load: 1 mA / 5 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O Contacts Materials: 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Amps. Res AC1 1 0.1 0 250 500 750 VA Table 2 1000 ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1 W (DC) VAC Ω mA VDC Ω mA 24 174 50 12 148 85 48 686 25 24 594 43 115 4K3 10.4 48 2K3 21 230 18K6 5.2 110 11K4 11 Insulation 1250 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Res Amps. AgNi + 0.3µ Au AgNi + 10µ Au 6A 15 A 250 V 1.2 KVA Operate time + bounce time 16 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C7-T21X ........VAC 1 2 3 5 4 6 7 A 8 B DC 12, 24, 48, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C7-T21X ....... VDC C7-T21DX..... VDC C7-T21FX ..... VDC C7-T21BX..... VDC 21 4.75 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 41 QRC 2-Pole, Miniature Power Plug-In Relay C7-G20 Power relay, DC application Two open contacts, Gap 1.5 mm Relay compatible with sockets: 10 A 250 V AC1 10A 30 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O 0.8 A 110 V DC1 0.4 A 220 V DC1 Contacts 3 4 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 7 A1(+) AgNi 10 A 30 A 250 V 2.5 KVA A2 Gap 1.5 mm 5 6 8 Coils (Ohms ±10% @ 20°C) Electrical Life, ops. x 106 Table 1 Ops. Res Cos ϕ 0.4 0.1 1 1.5 KVA Table 2 2 Ω mA VDC Ω mA 24 153 62 12 99 121 48 611 31 24 388 61 115 3K6 13 48 1K5 32 230 14K6 6.5 110 8K 14 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 DC1 Res L/R 40ms DC13 Amps. VAC 1 0.5 ≤0.8 x Un ≥0.1 x Un 1.5 VA (AC)/1.5 W (DC) Pull-in voltage Drop-out voltage Nominal coil power 10 2,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C7-G20X........VAC 1 2 3 5 4 6 7 A 8 B DC 12, 24, 48, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C7-G20X....... VDC C7-G20DX .... VDC C7-G20FX .... VDC C7-G20BX .... VDC 21 4.75 Lloyd´s FASTON .187 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 42 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC 1-Pole, Miniature Power Plug-In Relay C7-X10 Power relay, DC application Single pole, NO, double make Relay compatible with sockets: 10 A 250 V AC1 10 A 30V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O 6A 1A 110 V DC1 220 V DC1 Contacts 3 4 Materials: Standard, code 0 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 7 A1(+) A2 Gap 3 mm (1.5+1.5) 8 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. Res Cos ϕ 0.4 1 0.1 0.5 1 1.5 KVA Table 2 2 ≤0.8 x Un ≥0.1 x Un 1.5 VA (AC)/1.3 W (DC) VAC Ω mA VDC Ω mA 24 153 62 12 111 108 48 611 31 24 432 55 115 3K6 13 48 1K7 27 230 14K6 6.5 110 9K2 12 Insulation 2.5 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Res DC1 L/R 40ms Amps. AgNi 10 A 30 A 250 V 2.5 KVA 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 100 150 200 Volts Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C7-X10X ........VAC 1 2 3 5 4 6 7 A 8 B DC 12, 24, 48, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C7-X10X ....... VDC C7-X10DX .... VDC C7-X10FX ..... VDC C7-X10BX .... VDC 21 4.75 Lloyd´s IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 43 QRC 2-Pole, Miniature Power Plug-In Relay C7-H23 Power contact 10 A and bifurcated contact for current level Relay compatible with sockets: 10 A 250 V AC1 6 A 30 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O 6 A 250 V AC1 10 A 30 V DC1 Contacts 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Power Contacts Standard material Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Bifurcated Contacts Standard material Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Minimum current Max. DC load (Table 2) Electrical Life, ops. x 106 Table 1 10 AgNi 10 A 30 A 250 V 2.5 KVA AgNi + 0.3µ Au 6A 15 A 250 V 1 mA 5 V Ops. AC1 AC15 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 1 VAC 0.1 0.5 1 1.5 KVA Table 2 2 2.5 VDC Ω ± 10% mA mA 24 174 50 12 148 81 115 4K3 10.4 48 2K3 21 230 18K6 5.2 110 11K4 11 Max. DC Load 10 Insulation Dielectric strength (1 minute): Between adjacent poles Between contacts and coil Isolation, IEC 61810-5: AC1 Ops. Ω ± 10% ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1 W (DC) 2.5 KV 2.5 KV 2.5 KV/3 1 Specifications Max. working temperature Mechanical life ops. Protection degree Weight avg. 0.1 250 500 750 1,000 60°C ≥10 million IP 40 43 g VA Dimensions - mm Standard Types AC 24, 115, 230 1 2 3 5 4 6 7 A 8 B C7-H23 ..........VAC C7-H23X ........VAC X = LED DC 12, 24, 48, 110 X = LED Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 21 C7-H23 ......... VDC C7-H23X ....... VDC C7-H23DX .... VDC C7-H23FX..... VDC C7-H23BX .... VDC 4.75 FASTON .187 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 44 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC 1-Pole, Miniature Power Plug-In Relay C7-W10 High inrush current Single pole, wolfram and silver contacts Relay compatible with sockets: 10 A 250 V AC 250 V AC5a/b S7-M, S7-L, S7-P, S7-PO, S7-I/O Contacts 4 Materials: Standard, code 0 Max. switching current Max. peak inrush cutrrent (2.5 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 7 A1(+) AgNi 10 A 500 A 250 V 2.5 KVA A2 5 8 Coils (Ohms ±10% @ 20°C) Table 1 Electrical Life, ops. x 10 Ops. Res Cos ϕ 0.4 1 VAC Ω mA VDC Ω mA 24 153 62 48 611 31 12 99 121 24 388 115 3K6 61 13 48 1K5 32 230 14K6 4.5 110 8K 14 Insulation 0.1 0.5 1 1.5 KVA t 2 2.5 Dielectric strength (1 minute): Open contacts Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Operate time + bounce time 20 ms Release time + bounce time 10 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 250 500 750 1,000 V 2.5 KV ≥1 GΩ 2.5 KV Specifications AC5 a/b Ops. ≤0.8 x Un ≥0.1 x Un 1.5 VA (AC)/1.5 W (DC) Pull-in voltage Drop-out voltage Nominal coil power 106 1000 VA Standard Types Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C7-W10X .......VAC 1 2 3 5 4 6 7 A 8 B DC 12, 24, 48, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) C7-W10X ...... VDC C7-W10DX ... VDC C7-W10FX .... VDC C7-W10BX ... VDC 21 4.75 Lloyd´s IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 45 QRC 2-Pole, Miniature Plug-In Railway Relay R7-A20D Railway Application Relay According to EN 60077-1-2/99 - EN 61373/99 Relay compatible with sockets: 10 A 250 V AC1 10 A 30 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O Contacts 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Table 1 Materials: Standard, code 0 Optional, code 4 Optional, code 8 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Electrical Life, ops. x 106 Coils Operation Range Power Consumption Power Consumption Generated transients 10 AC1AC1 CosAC15 Phi 0.4 Ops. AgNi AgNi + 0.2µ Au AgNi + 10µ Au 10 A 30 A 250 V 0.7 Un @ 1.25 Un >0.1 Un 1.07 W OV, include FWD Ω ± 10% mA 24 535 45 48 2004 24 72 4750 15 110 11337 10 Voltage 1 0.1 250 Table 2 1000 VA 1500 2000 2500 Isolation Polution grade PD3 With voltage (1.2/50µs) / Dielectric strength (1 minute) Contact coil 4 KV/2,220 V Between different poles 4 KV/2,220 V Between contacts on the same pole 1,550 V Electrical Life, ops. x 106 10 Ops. AC1 Cos Phi 0.4 Specifications 1 Max working temperature Number of mechanical operations Thermic Class Vibration: Category/Class Vibration Shock Operation (UN)/release time Weight avg. Weight avg. Relay + Socket Relay Protection 0.1 25 100 175 225 Volts Dimensions - mm 1 2 3 5 4 6 7 A 8 B 40°C 20 million B (130°C) 1/B Body Mounted 5-150 Hz (3 axes) 5 g (3 axes) 10 ms/15 ms 35 g 75 g IP 40 Standard Types DC 24, 48, 72, 110 Free-wheeling diode R7-A20D....... VDC 21 4.75 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 46 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC 2-Pole, Miniature Plug-In Railway Relay R7-T21D Railway Application Relay According to EN 60077-1-2/99 - EN 61373/99 Relay compatible with sockets: 6A 250 V AC1 6A 30 V DC1 S7-M, S7-L, S7-P, S7-PO, S7-I/O Contacts Materials: Table 1 1 3 2 4 7 12 14 22 24 A1(+) 11 21 A2 5 6 8 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load 100,000 ops. Coils Electrical Life, ops. x 106 Operation Range Power Consumption Power Consumption Generated transients 10 AC1AC1 CosAC15 Phi 0.4 Ops. AgNi + 0.2µ Au AgNi + 10µ Au 6A 15 A 250 V 1 0.7 Un @ 1.25 Un >0.1 Un 1.07 W OV, include FWD Voltage Ω ± 10% mA 24 535 45 48 2004 24 72 4750 15 110 11337 10 0.1 250 Table 2 1000 VA 1500 2000 2500 Isolation Polution grade PD3 With voltage (1.2 / 50µs)/Dielectric strength (1 minute) Contact coil 4 KV/2,220 V Between different poles 4 KV/2,220 V Between contacts on the same pole 1,550 V Electrical Life, ops. x 106 10 Ops. DC1 4R 40 ms Specifications Max working temperature Number of mechanical operations Thermic Class Vibration: Category/Class Vibration Shock Operation (UN)/release time Weight avg. Weight avg. Relay + Socket Relay Protection 1 0.1 25 100 175 225 Volts Dimensions - mm 1 2 3 5 4 6 7 A 8 B 40°C 20 million B (130°C) 1/B Body Mounted 5-150 Hz (3 axes) 5 g (3 axes) 10 ms/15 ms 35 g 75 g IP 40 Standard Types DC 24, 48, 72, 110 Free-wheeling diode R7-T21D ....... VDC 21 4.75 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 47 QRC Miniature 4-Pole Plug-In Relay C9-A41 General purpose Four pole, change-over contacts Relay compatible with sockets: 5A 5A S9-M, S9-L, S9-P, S9-PO 250 V AC1 30 V DC1 0.2 A 110 V DC1 Contacts Materials: 1 5 2 6 3 7 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (2.5 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) 13 4 8 12 14 22 24 32 34 42 44 A1(+) 11 21 31 41 A2 9 10 11 12 14 Coils (Ohms ±10% @ 20°C) Electrical Life, ops. x 106 Table 1 Ω VAC Res Ops. ≤0.8 x Un ≥0.1 x Un 1.2 VA (AC)/1 W (DC) Pull-in voltage Drop-out voltage Nominal coil power 10 24 48 72 115 230 1 174 686 1587 4K3 18K6 AgNi + 0.2µAu AgNi + 10µAu 5A 15 A 250 V 1250 KVA mA VDC 50 25 17 10.4 5.2 12 24 48 172 110 Ω 148 594 2K3 5089 11K4 mA 85 43 21 14.1 11 0.1 0 400 800 Insulation 1200 VA Table 2 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Amps. Res Specifications Operate time + bounce time 10 ms Release time + bounce time 6 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 75 125 Volts 200 175 Dimensions - mm Standard Types 28 28 37.5 1,000 V 2 KV 2.5 KV ≥1 GΩ 2.5 KV AC 50 Hz, (60 Hz): 24, 48, 72, 115, (120), 230, (240) X = LED (standard) C9-A41X ........VAC 1 3 24 5678 910 1112 1 2 3 4 5 9 6 10 7 11 8 12 13 13 DC 12, 24, 48, 72, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 14 14 21 21 C9-A41X ....... VDC C9-A41DX .... VDC C9-A41FX..... VDC C9-A41BX .... VDC 2.6 IEC 61810 EN 60947 FASTON .102 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 48 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC Miniature 2-Pole Relay C9-R21 Magnetic latching relay Two change-over contacts, 5 A Relay compatible with sockets: 5A 5A S9-M, S9-L, S9-P, S9-PO 120 V AC1 30 V DC1 Contacts 1 5 4 8 13 10 12 14 22 24 A1 A3 ON (+) OFF (+) 11 21 A2 (-) 9 12 14 Materials: Standard, code 1 Max. switching current Max. peak inrush current (10 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils Electrical Life, ops. x 106 Table 1 ON pulse power OFF pulse power One winding for AC. Two windings for DC. 10 VAC Ops. Res 1 400 800 1200 Max. DC Load 10 ON mA OFF mA 50 8 12 100 25 48 25 4 24 50 12 115 10 2 48 25 6 230 5 1 60 20 5 1,000 V 2 KV 2 KV ≥1 GΩ 2.5 KV/2 Specifications Res Amps. VDC 24 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: VA Table 2 ON mA OFF mA 1.2 VA/W 0.3 VA/W Insulation 0.1 0 AgNi + 0.2µAu 5A 15 A 250 V 1,200 KVA Minimum, pulse length for ON/OFF 50 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 43 g 1 0.1 50 75 125 Volts 200 175 Standard Types 28 28 37.5 Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) C9-R21 ..........VAC 1 3 24 5678 910 1112 1 2 3 4 5 9 6 10 7 11 8 12 13 13 DC 12, 24, 48, 60 C9-R21 ......... VDC 14 14 21 21 2.6 Lloyd´s IEC 61810 EN 60947 FASTON .102 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 49 QRC Miniature 2-Pole Relay C9-E21 General purpose. Sensitive 500 mW Two pole, change-over contacts DC operating range: 0.8-1.7 x Un Relay compatible with sockets: 5A S9-M, S9-L, S9-P, S9-PO 250 V AC1 5A 30 V DC1 Contacts Materials: 1 5 4 8 13 12 14 22 24 A1(+) 11 21 A2 9 12 14 Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (2.5 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power Electrical Life, ops. x 106 Table 1 10 Ops. Res 800 1200 mA VDC Ω mA 1K1 21 12 288 42 48 4K6 10 24 1K1 21 Table 2 115 5K9 7 48 4K6 10 230 23K9 3.5 110 24K2 4.5 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts and coil Isolation resistance at 500 V Isolation, IEC 61810-5: VA Max. DC Load 10 1,000 V 2.5 KV 2.5 KV ≥1 GΩ 2.5 KV/3 Specifications Res Amps. Ω 24 Insulation 0.1 400 ≤0.8 x Un ≥0.1 x Un 0.8 VA (AC)/0.5 W (DC) VAC 1 0 AgNi + 0,2µAu AgNi + 10µAu 5A 15 A 250 V 1,200 KVA Operate time + bounce time 10 ms Release time + bounce time 6 ms Ambient temperature -40°C (no ice) to +60°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 40 g 1 0.1 50 75 125 Volts 200 175 Standard Types 28 28 37.5 Dimensions - mm AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C9-E21X ........VAC 1 3 24 5678 910 1112 1 2 3 4 5 9 6 10 7 11 8 12 13 13 DC 12, 24, 48, 110 X = LED, no polarity (standard) Free-wheeling diode Polarity and free-wheeling diodes AC/DC bridge rectifier (24, 48 or 60 V) 14 14 21 21 C9-E21X ....... VDC C9-E21DX .... VDC C9-E21FX ..... VDC C9-E21BX .... VDC 2.6 Lloyd´s IEC 61810 EN 60947 FASTON .102 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 50 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications C10-A10 One pole, change-over contact 10 A 250 V AC1 10 A 30 V DC1 13 A 250 V AC1 Relay compatible with sockets: S10, S10-M, S10-P, S10-K 0.5 A 110 V DC1 0.2 A 220 V DC1 Contacts Materials: Standard, code 0 Optional, code 8 Optional, code 5 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 0.5 mm. Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 Cos ϕ 0.4 ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 VAC 1 AgNi AgNi + 10µ Au AgSnO2 10 A 30 A 250 V 2.5 KVA 0.1 500 1000 1500 2500 Insulation VA Table 2 Dielectric strength (1 minute): Open contacts Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 5 KV ≥1 GΩ 4 KV/3 Amps. DC1 L/R 40ms Specifications Operate time + bounce time 10 ms Release time + bounce time 5 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g 1 0.1 50 100 150 200 Volts Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C10-A10X ......VAC RC suppressor C10-A10R......VAC DC 12, 24, 48, 110 X = LED, no polarity (standard) C10-A10X ..... VDC Options (DC coils) Polarity and free-wheeling diodes C10-A10FX... VDC AC/DC bridge rectifier (24 or 48 V) C10-A10BX .. VDC 1 28.8 2 35.4 3 5 4 20 6 A1 A2 12.5 4.75 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 51 IRC Interface and General Applications C10-A10E One pole, change-over contact Relay compatible with sockets: S10, S10-M, S10-P, S10-K 10 A 250 V AC1 10 A 30 V DC1 13 A 250 V AC1 0.5 A 110 V DC1 0.5 A 220 V DC1 Contacts Materials: Standard, code 0 Optional, code 8 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 0.5 mm. Table 1 Electrical Life, ops. x 106 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 Cos ϕ 0.4 1 AgNi AgNi + 10µ Au 10 A 30 A 250 V 2.5 KVA ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) VAC Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 0.1 500 1000 1500 2000 Insulation VA Table 2 Dielectric strength (1 minute): Open contacts Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 5 KV ≥3 GΩ 4 KV/3 Amps. DC1 L/R 40ms Specifications Operate time + bounce time 10 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g 1 0.1 50 100 150 200 Volts Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) C10-A10E ......VAC DC 12, 24, 48, 110 C10-A10E ..... VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 52 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications C10-G10 One pole, open contact 10 A 250 V AC1 10 A 30 V DC1 Relay compatible with sockets: 0.8 A 110 V DC1 0.4 A 220 V DC1 S10, S10-M, S10-P, S10-K Contacts Materials: Standard, code 0 Optional, code 8 Optional, code 5 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 1 mm. Electrical Life, ops. x 106 Table 1 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 Cos ϕ 0.4 ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 VAC 1 AgNi AgNi + 10µ Au AgSnO2 10 A 30 A 250 V 2.5 KVA 0.1 500 1000 1500 2500 Insulation VA Table 2 Dielectric strength (1 minute): Open contacts Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 2000 V 5 KV ≥1 GΩ 4 KV/3 Amps DC1 110V DC1 220V Specifications 1 Operate time + bounce time 10 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g 0.1 75 125 Volts 175 225 Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C10-G10X......VAC RC suppressor C10-G10R .... VAC DC 12, 24, 48, 110 X = LED, no polarity (standard) Options (DC coils) Polarity and free-wheeling diodes AC/DC bridge rectifier (24 or 48 V) C10-G10X..... VDC C10-G10FX .. VDC C10-G10BX .. VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 53 IRC Interface and General Applications C10-T13 One change-over twin contact 6A 6A Relay compatible with sockets: 250 V AC1 30 V DC1 0.5 A 110 V DC1 0.2 A 220 V DC1 S10, S10-M, S10-P, S10-K Contacts Materials: Standard, code 3 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 0.5 mm. Table 1 Electrical Life, ops. x 106 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 VAC 1 AgNi + 3µ Au AgNi + 10µ Au 6A 15 A 250 V 1.5 KVA 0.1 500 1000 1500 Insulation VA Table 2 Dielectric strength (1 minute): Open contacts Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 1,000 V 5 KV ≥1 GΩ 4 KV/3 Amps DC1 Specifications Operate time + bounce time 10 ms Release time + bounce time 5 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC relays, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g 1 0.1 75 125 Volts 175 225 Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C10-T13X ......VAC RC suppressor C10-T13R ......VAC 1 28.8 2 35.4 3 DC 12, 24, 48, 110 X = LED, no polarity (standard) C10-T13X ..... VDC Options (DC coils) Polarity and free-wheeling diodes C10-T13FX ... VDC AC/DC bridge rectifier (24, 48 or 60 V) C10-T13BX... VDC 5 4 20 6 A1 A2 12.5 4.75 IEC 61810 EN 60947 FASTON .187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 54 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications C10-GT13 One pole, twin open contact 6A 6A Relay compatible with sockets: 250 V AC1 30 V DC1 0.8 A 110 V DC1 0.4 A 220 V DC1 S10, S10-M, S10-P, S10-K Contacts Materials: Standard, code 3 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 1 mm. Table 1 Electrical Life, ops. x 106 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power 10 Ops. AC1 1 AgNi + 3µ Au AgNi + 10µ Au 6A 15 A 250 V 1.5 KVA ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) VAC Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 0.1 500 1000 1500 Insulation VA Table 2 Dielectric strength (1 minute): Open contacts Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 2,000 V 5 KV ≥3 GΩ 4 KV/3 Specifications Operate time + bounce time 10 ms Release time + bounce time 8 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC relays, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C10-GT13X ...VAC RC suppressor C10-GT13R ...VAC DC 12, 24, 48, 110 X = LED, no polarity (standard) Options (DC coils) Polarity and free-wheeling diodes AC/DC bridge rectifier (24 or 48 V) C10-GT13X .. VDC C10-GT13FX..VDC C10-GT13BX..VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 55 IRC Interface and General Applications C12-A21 Two poles, change-over contacts 5A 5A Relay compatible with sockets: 250 V AC1 30 V DC1 0.5 A 110 V DC1 0.2 A 220 V DC1 S12, S12-P Contacts Materials: Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 0.5 mm. Table 1 Electrical Life, ops. x 106 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power AgNi + 0.2µ Au AgNi + 10µ Au 5A 15 A 250 V 1.2 KVA ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) VAC Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between adjacents poles Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Amps DC1 1,000 V 3,000 V 5 KV ≥3 GΩ 4 KV/3 Specifications 1 Operate time + bounce time 10 ms Release time + bounce time 5 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC relays, 20 Mill. DC relays tElectrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection degree IP 40/RT1 Weight avg. 21 g 0.1 50 150 50 200 Volts Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C12-A21X ......VAC RC suppressor C12-A21R......VAC DC 12, 24, 48, 110 X = LED, no polarity (standard) C12-A21X ..... VDC Options (DC coils) Polarity and free-wheeling diodes C12-A21FX... VDC AC/DC bridge rectifier (24, 48 or 60 V) C12-A21BX .. VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 56 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications C12-G21 Two poles, open contacts 5A 5A Relay compatible with sockets: 250 V AC1 30 V DC1 0.8 A 110 V DC1 0.4 A 220 V DC1 S12, S12-P Contacts Materials: Standard, code 1 Optional, code 2 Max. switching current Max. peak inrush current (20 ms) Max. switching voltage Max. AC load (Table 1) Max. DC load (Table 2) Gap 1 mm Table 1 Electrical Life, ops. x 106 Coils (Ohms ±10% @ 20°C) Pull-in voltage Drop-out voltage Nominal coil power AgNi + 0.2µ Au AgNi + 10µ Au 5A 15 A 250 V 1.2 KVA ≤0.8 x Un ≥0.1 x Un 1.1 VA (AC)/0.7 W (DC) VAC Ω mA VDC Ω mA 24 290 45 12 224 53 48 1,200 23 24 742 32 115 7,300 9.5 48 3,500 13.7 230 28,800 4.7 110 19,900 5.5 Insulation Table 2 Dielectric strength (1 minute): Open contacts Between adjacents poles Between contact and coil Isolation resistance at 500 V Isolation, IEC 61810-5: Max. DC Load 10 Amps DC1 2,000 V 3,000 V 5 KV ≥3 GΩ 4 KV/3 Specifications 1 Operate time + bounce time 10 ms Release time + bounce time 5 ms Ambient temperature -40°C (no ice) to +70°C Mechanical life ops. 10 Mill. AC, 20 Mill. DC relays Electrical life at nominal load ≥100,000 ops. Operating frequency at nominal load 1,200/hour Protection grade IP 40/RT1 Weight avg. 21 g 0.1 50 100 150 200 Volts Dimensions - mm Standard Types AC 50 Hz, (60 Hz): 24, 48, 115, (120), 230, (240) X = LED (standard) C12-G21X......VAC RC suppressor C12-G21R .....VAC DC 12, 24, 48, 110 X = LED, no polarity (standard) C12-G21X..... VDC Options (DC coils) Polarity and free-wheeling diodes C12-G21FX .. VDC AC/DC bridge rectifier (24, 48 or 60 V) C12-G21BX .. VDC IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 57 IRC Interface and General Applications CSS-DCP Solid state relay DC inductive or resistive load switching Positive common output One open contact Relay compatible with sockets: S10, S10-M, S10-P, S-10K 2 A @ 5-50 VDC CSS-DCP Input, Polarity Protected Range of input voltage Drop-out voltage Input current Current stabilizer Peak inrush voltage protection 5-32 VDC <2.5 VDC 3 ±1 mA Yes EC-1000-4-5 Level 1 Output, Positive Common Max. output current Max. output voltage Minimum output voltage Max. drop voltage Max. leakage current at 48 VDC Max. overcurrent pulse Pulse protection Max. current at inverse voltage 2A 50 VDC 5 VDC 1.3 VDC <100 µA 5 A, 350 µs IEC-1000-4-5 Level 1 1A Positive Common +(-)A1 -1 -(+)A2 +2 Common Max. DC Load vs. Ambient Temperature Specifications Dielectric strengh input / output Operate time Release time, max. Working temperature, max. Storage temperature Weight avg. A CSS-DCP 2 4 KV/1 min. 1 ms 2 ms 60°C 80°C 28 g 1 Applications -20 0 20 40 60 ºC To switch up to 50 VDC, heating elements electrovalves, motors, input/output signals on PLC’s, solenoids, incandescent and fluorescent lamps, etc. Inductive loads must be shunted with an antiparallel diode. Tamb. Dimensions - mm +(-)A1 5 - 32 VDC -(+)A2 +(-)A1 5 - 32 VDC -(+)A2 1 CSS DC-P 5 - 50 VDC 2 1 CSS DC-P 5 - 50 VDC 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 58 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications CSS-DCN Solid state relay DC inductive or resistive load switching Negative common output One open contact Relay compatible with sockets: S10, S10-M, S10-P, S-10K 2 A @ 5-50 VDC Input, Polarity Protected Range of input voltage Drop-out voltage Input current Current stabilizer Peak inrush voltage protection CSS-DCN 5-32 VDC <2.5 VDC 3 ±1 mA Yes EC-1000-4-5 Level 1 Negative Common Output, Positive Common +(-)A1 Max. output curren Max. output voltage Minimum output voltage Max. drop voltage Max. leakage current at 48 VDC Max. overcurrent pulse Pulse protection Max. current at inverse voltage +1 -(+)A2 -2 Common Max. DC Load vs. Ambient Temperature Specifications Dielectric strengh input / output Operate time Release time, max. Working temperature, max. Storage temperature Weigth avg. A CSS-DCN 2 2A 50 VDC 5 VDC 1.3 VDC <100 µA 5 A, 350 µs IEC-1000-4-5 Level 1 1A 4 KV/1 min 1 ms 2 ms 60°C 80°C 28 g 1 Applications -20 0 20 40 60 ºC To switch, up to 50 VDC, heating elements electroalves, motors, input/output signals on PLC’s, solenoids, incandescent and fluorescent lamps, etc. Inductive loads must be shunted with an antiparallel diode. Tamb. Dimensions - mm +(-)A1 5 - 32 VDC -(+)A2 +(-)A1 5 - 32 VDC -(+)A2 1 CSS DC-N 5 - 50 VDC 2 1 CSS DC-N 5 - 50 VDC 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 59 IRC Interface and General Applications CSS-AC Solid state relay AC inductive loads switching Relay compatible with sockets: One open contact S10, S10-M, S10-P, S-10K 3 A @ 24-250 V AC, 50/60 Hz Input, Polarity Protected Range of input voltage Drop-out voltage Input current Current stabilizer Peak inrush voltage protection CSS-AC 5-32 VDC <2.5 VDC 5-15 mA Yes EC-1000-4-5 Level 1 AC Instantaneous Output Ouput, Instantaneous +(-)A1 1 -(+)A2 2 Max. output current Minimum output current Max. output voltage Minimum output voltage Max. drop voltage Max. leakage current Max. Dv/dt I2t for 10 ms. fuse Max. AC Load vs. Ambient Temperature 3A 50 mA 250 VAC 24 VAC <1.5 VAC 0.55 mA 500 V/µs 50 A2/s Specifications Dielectric strength input/output Operate time Release time Working temperature, max. Storage temperature, max. Weight avg. A CSS-AC 3 4 KV/1min. 1/2 cycle 2 ms + 1/2 cycle 60°C 80°C 28 g 2 Applications 1 Suitable to switch inductive loads up to 3 A/250 VAC. -20 0 20 40 60 ºC In switching loads with a high inrush or overcurrent (max. Di/dt 50 A/µs) such as transformers, motors or fluorescents, the maximum output current limit it 2 A. Tamb. Dimensions - mm +(-)A1 5 - 32 VDC -(+)A2 +(-)A1 5 - 32 VDC -(+)A2 1 CSS AC 230 VAC 2 1 CSS AC M 230 VAC 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 60 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications CSS-AZ Solid state relay AC resistive loads switching Relay compatible with sockets: One open contact S10, S10-M, S10-P, S-10K 3 A @ 24-250 V AC, 50/60 Hz Input, Polarity Protected Range of input voltage Drop-out voltage Input current Current stabilizer Peak inrush voltage protection CSS-AZ 5-32 VDC <2.5 VDC 5-15 mA Yes EC-1000-4-5 Level 1 AC, Syncronized to Zero Ouput, Synchronized to Zero +(-)A1 Max. output current Minimum output current Max. output voltage Minimum output voltage Max. drop voltage Max. leakage current Max. Dv/dt I2t for 10 ms. fuse 1 Z -(+)A2 2 Max. DC Load vs. Ambient Temperature 3A 50 mA 250 VAC 24 VAC <1.5 VAC 0.55 mA 500 V/µs 50 A2/s Specifications Dielectric strength input/output Operate time Release time Working temperature, max. Storage temperature, max. Weight avg. A CSS-AZ 3 4 KV/1min. 1/2 cycle 2 ms + 1/2 cycle 60°C 80°C 28 g 2 Applications 1 Switches AC resistive loads up to 3 A/250 VAC in the zero point of the tension and avoids any overcurrent peak in the connection. -20 0 20 40 60 ºC Tamb. Suitable to switch resistors, incandescent lamps, signalling, etc. Dimensions - mm Not suitable for inductive loads. +(-)A1 5 - 32 VDC -(+)A2 1 CSS AZ 230 VAC 2 RES +(-)A1 5 - 32 VDC -(+)A2 1 CSS AZ 230 VAC 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 61 Notes: Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 62 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 SOCKETS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 63 MRC Socket for Universal 8-Pin Relays S2-B Two pole, one level, coding ring Integrated clip and marking label 10 A 300 V Socket for MRC, 8-Pin Plug-In Relay Types C2-A20, C2-G20, C2-T21 • Accepts the exclusive RELECO coding ring for coding both relay and socket • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram 7 ( A2 ) 6 ( 24 ) 8 ( 21 ) 5 ( 22 ) 1 ( 11 ) 4 ( 12 ) 2 ( A1) ( 14 ) Specifications Nominal Load: 10 A/300 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1.2 Nm M3, Pozi 6 24 ø8.2 2.5 KV 2.5 KV 2.5 KV ø 5.3 8 M3 7 5 38 6 4 3 2 S2-B 2 24 22 12 14 1 A2 21 11 A1 8 RELECO 7 29.75 Lloyd´s 68 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 64 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC Socket for Universal 8-Pin Relays S2-S Two pole, two level, coding ring Integrated clip and marking label 10 A 300 V Socket for MRC, 8-Pin Plug-In Relay Types C2-A20, C2-G20, C2-T21 • Accepts the exclusive RELECO coding ring for coding both relay and socket • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram 7 ( A2 ) 6 ( 24 ) 8 ( 21 ) 5 ( 22 ) Specifications Nominal Load: 3 ( 14 ) 1( 11 ) 2 ( A1) 10 A/300 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles 4 ( 12 ) Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1.2 Nm M3, Pozi 7.2 25 ø8.2 2.5 KV 2.5 KV 2.5 KV ø5.3 10 M3.5 4 12 30 5 22 3 14 4 2 6 24 5 Label S2-S 1 11 RELECO 8 21 2 A1 7 7 A2 38 M3 80 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 65 MRC PC Sockets for Relays C2- … and C3- … S2-L S3-L 2-Pole Flange Panel Mountable S2-PO 2-Pole Printed Circuit with Flange S2-L 3-Pole Flange Panel Mountable S3-PO S2-PO 3-Pole Printed Circuit with Flange S3-L Specifications S3-PO Specifications Nominal Load Dielectric Strength Adjacent Pin 10 A/300 V 2.5 KV Nominal Load Dielectric Strength Adjacent Pin Printed Circuit Lay-Out 10 A/250 V 2.5 KV Printed Circuit Lay-Out 32°44’ 32°44’ 45° ø1.3 ø1.3 2 7 8 5 4 8 17.5 3 6 6 7 4 3 9 2 10 1 11 1 38 38 3.4 Dimensions - mm 3.4 Dimensions - mm 19 5 39 39 49 49 4 4 ø29.5 ø29.5 4.7 S3-PO 15 S2-PO PO 15 PO 1 4.7 1 15 10 S3-L 15 10 S2-L 7 L 7 L Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 66 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC Socket for Universal 11-Pin Relays S3-S Three pole, two level, coding ring Integrated clip and marking label 10 A 250 V Socket for MRC, 11-Pin Plug-In Relay Types C3-A30, C3-G30, C3-T31, C3-X10, C3-M10, C3-R20, C3-E24, C3-N34 • Accepts the exclusive RELECO coding ring for coding both relay and socket. • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering Wiring Diagram 10 ( A2 ) According to EN 60947-1 and IEC 61810-5 11( 31 ) 9 ( 34 ) 8 ( 32 ) 6 ( 21 ) 7 ( 24 ) 5 ( 22 ) 1( 11 ) 3 ( 14 ) 4 ( 12 ) 2 ( A1) Specifications Nominal Load: 10 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 7.2 25 ø8.2 2.5 KV 2.5 KV 2.5 KV ø5.3 10 M3.5 5 22 4 12 30 8 32 3 14 5 S3-S 2 1 11 7 24 7 RELECO 10 6 21 2 A1 9 34 11 31 10 A2 38 M3 80 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 67 MRC Socket for Universal 11-Pin Relays S3-B Three pole, one level, coding ring Integrated clip and marking label 10 A 250 V Socket for MRC, 11-Pin Plug-In Relays Types C3-A30, C3-G30, C3-T31, C3-X10, C3-M10, C3-R20, C3-E24, C3-N34 • Accepts the exclusive RELECO coding ring for coding both relay and socket. • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering Wiring Diagram According to EN 60947-1 and IEC 61810-5 9 ( 34 ) 10 ( A2 ) 8 ( 32 ) 11 ( 31 ) 7 ( 24 ) 1 ( 11 ) 6 ( 21 ) 2 ( A1) 5 ( 22 ) 3 ( 14 ) 4 ( 12 ) Specifications Nominal Load: 10 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 6 24 ø8.2 2.5 KV 2.5 KV 2.5 KV ø 5.3 M3 7 38 8 7 6 5 5 2 S2-B 4 3 32 24 21 22 12 10 RELECO 2 34 A2 31 11 A1 14 9 10 11 1 29.75 8 Lloyd´s 68 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 68 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC Socket for Universal 11-Pin Relays S3-MP Three pole, one level Accepts plug-in modules M3P in parallel with the coil 10 A 250 V Socket for MRC, 11-Pin Plug-In Relay Types C3-A30, C3-G30, C3-T31, C3-X10, C3-M10, C3-R20, C3-E24, C3-N34 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram 10 (A2) 9 (34) 11 (31) M o d u l e 6 (21) 1 (11) 8 (32) Specifications 7 (24) Nominal Load: 5 (22) Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles 3 (14) 2 (A1) 10 A/250 V 4 (12) Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 7.5 26 ø8.2 2.5 KV 2.5 KV 2.5 KV ø4.3 7 5 38 8 3 2 4 34 32 24 22 14 12 9 RELECO S3-MP 2 10 10 11 6 A1 1 A2 31 21 11 29.5 ø3.2 75 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 69 MRC Socket for Universal 11-Pin Relays S4-J Four pole, two level, logic wiring Integrated clip and marking label 10 A 250 V Socket for MRC, 14-Pin Plug-In Relay Types C4-A40, C4-X20, C4-T31, C4-R30 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947 Wiring Diagram Specifications Nominal Load: 10 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 24-14 AWG 4 mm2 1. 2 Nm M3, Pozi 7 32 ø9 2.5 KV 2.5 KV 2.5 KV ø5.5 Lloyd´s 5 4 2 1 11 44 8 34 5 24 2 14 7 10 42 7 32 4 22 1 12 8 6 10 3 11 9 13 S2-B 13 A1 12 14 RELECO 14 21 12 41 9 31 6 21 3 11 38 M4/M5 92 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 70 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 MRC PC Sockets for Relays C4-… and C5-… S4-L 4-Pole Flange Panel Mountable S4-PO 4-Pole Printed Circuit with Flange S5-L 3-Pole Flange Panel Mountable S5-P 3-Pole Printed Circuit S5-PO 3-Pole Printed Circuit with Flange S5-PO S5-L S4-L S5-P S4-PO Specifications Specifications Nominal Load Dielectric Strength Adjacent Pin 10 A/250 V 2.5 KV Nominal Load Dielectric Strength Adjacent Pin Printed Circuit Lay-Out Printed Circuit Lay-Out 24 22.1 8 16 A/400 V 4 KV ø 2.5 ø1.5 5.5 6.5 0.9 8.3 7 0.2 6.75 7.7 6.75 Dimensions - mm Dimensions - mm S4-PO S4-L 6 15.5 6 M3 7.5 5 15.4 S5-L 7.5 7.3 57 47 M3 S5-PO 35.4 35.5 57 47 RELECO S4-L S5-P 36 S4-P 36 RELECO S4-P 1.2 2 2.8 35.5 3.5 35.4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 71 MRC Socket for Square Socket Relays C5-… S5-S Three pole, two level, logic wiring Integrated clip and marking label 16 A 400 V Socket for MRC, 11-Pin Plug-In Relay Types C5-A20, C5-A30, C5-G30, C5-X10, C5-M10, C5-M20, C5-R20 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram 10 ( 42 ) 11 ( 44 ) 9 ( 31 ) 7 ( 32 ) 8 ( 34 ) 6 ( 21 ) 4 ( 22 ) 5 ( 24 ) 3 ( 11 ) 13 ( A1) 1 ( 12 ) 2 (14 ) 12 ( 41 ) 14 ( A2 ) Specifications Nominal Load: 16 A/400 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 11.5 29.4 ø 6.5 4 KV 4 KV 4 KV ø 4.2 8.3 6 34 2 22 5 24 1 12 4 14 RELECO 8 21 3 32 B A2 9 31 38 M4 S5-S A A1 7 11 80 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 72 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC Socket for Miniature Two Pole C7-… S7-M Two pole, one level Integrated clip and marking label 10 A 250 V Socket for QRC, 2-Pole Plug-In Relay Types C7-A20, C7-T21, C7-G20, C7-X10, C7-W10 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram Specifications Nominal Load: 8 ( A2 ) 4 ( 24 ) 6 ( 21 ) 2 ( 22 ) 5 ( 11 ) 3 ( 14 ) 7 ( A1) 1( 12 ) 10 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 26 Dimensions - mm 2.5 KV 2.5 KV 2.5 KV Lloyd´s 2 3 5 1 7 24 22 14 12 4 S7-M 6 RELECO 8 A2 21 11 A1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 73 QRC Socket for Miniature C7-… Relays S7-I/O Two pole, one level Integrated clip and marking label 10 A 250 V Socket for QRC, 2-Pole Plug-In Relay Types C7-A10 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram Specifications Nominal Load: 10 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label Dimensions - mm 2.5 KV 2.5 KV 2.5 KV 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi Lloyd´s Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 74 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC Socket for Miniature C7-A10… Relays S7-16 One pole, one level Integrated clip and marking label 16 A 250 V Socket for MRC, 1-Pole Plug-In Relay Types C7-A10 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram Specifications Nominal Load: 5 (11) 16 A/250 V 4 (14) 8 (A2) Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles M o d u l e 7 (A1) 1 (12) Dimensions - mm 26 S7-16 for use with C7-A10 (16A) Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label 2.5 KV 2.5 KV 2.5 KV 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 4 14 1 12 RELECO 5 S7-16 8 11 A1 7 A2 22.5 Lloyd´s 75 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 75 QRC PC Sockets for Relays C7-… and C9-… S7-P S9-P 2-Pole Circuit 2-Pole Printed Flange Panel Mountable Printed Circuit S7-PO 2-Pole with Flange Printed Circuit S9-PO 4-Pole with Flange S7-PO S7-P 4-Pole Printed Circuit S9-PO Specifications S9-P Specifications Nominal Load Dielectric Strength Adjacent Pin 10 A/250 V 2.5 KV Nominal Load Dielectric Strength Adjacent Pin Printed Circuit Lay-Out 6 A/250 V 2.5 KV Printed Circuit Lay-Out 10 4.4 4.7 5.9 0.6 4.05 0.6 6.35 7.25 6.35 ø2.5 14.5 Dimensions - mm Dimensions - mm S9-PO S7-PO 22.5 22.5 1 3 6 5 M3 13.1 36.4 2 4 5.2 RELECO 7 S7-L 2 7 6 4 12.6 1 5 12 11 10 9 RELECO S9-L 13 A S7-P S9-P 2 1 4 3 2 4 3 8 7 6 6 5 RELECO 7 S7-P 2 30 30 3 14 B 8 4 8 46 46 36.4 M3 8 ø 1.7 13.2 3.5 12 11 10 9 RELECO 14 A B 1 5 22.5 S9-P 2.6 1.2 13 22.5 Lloyd´s Lloyd´s Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 76 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 QRC Sockets for Miniature Four Pole C9-… S9-M Four pole, two level Integrated clip and marking label 6A 250 V Socket for QRC, 4-Pole Plug-In Relay Types C9-A41, C9-E21, C9-R21 • DIN rail or panel mountable • Removable label • EN/DIN and sequencial numbering According to EN 60947-1 and IEC 61810-5 Wiring Diagram Specifications Nominal Load: 6 A/250 V Insulation: Dielectric strength, 1 minute Between contacts and coil Between all terminals and rail DIN Between adjacent poles Wire In-Lets Capacity: Solid wire Multi-core Ferrule tip terminals Max. screw torque Screw dimensions Integrated hold-down clip Removable marking label 46.5 20.5 Dimensions - mm 2.5 KV 2.5 KV 2000 V 4 mm2 or 2 x 2.25 mm2 22-14 AWG 4 mm2 1. 2 Nm M3, Pozi 44 34 24 14 1 8 7 6 5 42 32 22 12 5 1 2 2 3 6 RELECO 7 3 4 8 13 13 4 14 S9-M 12 11 10 9 14 A2 A1 12 11 10 9 41 31 21 11 22.5 26 Lloyd´s 75 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 77 IRC Interface and General Applications S10 Socket for C10-C14-CSS relays DIN rail or panel mountable 10 A 250 V Interface I/O socket, with terminals in-line for relays C10A, C10G, C10T, CSS Specifications Poles Nominal load Dielectric strength Coil - contacts Terminals - Rail Max. screw torque Multi-core capacity Solid wire capacity Weight average Wiring Diagram 1 10 A/250 V 5 KV 5 KV 1.2 Nm 22-14 AWG 4 mm2 or 2 x 2.25 mm2 28 g Other Aspects • • • • Dimensions - mm Hard brass tin-plated terminals Brass zinc-plated solid screws Integrated clip Removable marking label Ø6 Accessories 12.5 26 Bridge bar for coil and movable contact (S10-BB) Integrated clip DIN rail or panel mounting Maximum current through bridge 10 A Maximum current input common cable 20 A Ø3.5 Ø2.8 12 3 5 A2 11 2 11 S10 5 A2 1 4 14 2 A1 6 15.6 39.5 3.4 M3 75 Bridge Bus Bar S10-BB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 78 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications S10-M New I/O socket for IRC relays one change-over contact 16 A 250 V I/O socket, with terminals in-line for relays C10A, C10G, C10T, C14A, C14G, C16A, C16G and CSS Both this socket and the S12 are designed to get a homogeneous set with identical terminal disposition, which allows the easy identification of the contacts set in each level and a simpler wiring. Wiring Diagram 5(A2) 3(12) 6(A2) 2(11) 4(A1) 1(14) Both A2 terminals allow a secure interconnection through external bridges among an unlimited number of these sockets or a mixture of S10-M and the S12. The A2 terminal, free on both the first and last sockets, is used to connect the cable of common polarity. Specifications Dimensions - mm Nominal load 16 A/250 V Insulation: Dielectric strength, 1 minute Between coil and contacts 5 KV Between all terminals and rail DIN 5 KV Max. screw torque 1.2 Nm Screw dimensions M3, Pozi Wire in-lets capacity: Solid wire 4 mm2 or 2 x 2.25 mm2 Multi - core 22-14 AWG Ferrule tip terminals 4 mm2 Integrated hold-down clip Removable marking label 12.5 26 Ø6 Ø3.5 2 S10-M 6 4 1 12 11 14 3 5 A2 A2 A1 16.9 Ø2.8 39.5 3.4 M3 61 75 75 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 79 IRC Interface and General Applications S10-P S12-P Printed circuit socket for 1 pole IRC Relays Printed circuit socket for 2-pole IRC Relays Specifications Specifications Nominal load Dielectric strength, 1 min. Coil terminals to contacts Hard brass tin-plated terminals Integrated hold-down clip 10 A/250 V 5KV 0.5 x 1 mm 14.8 13.6 5 31.7 1 3.65 3.65 S12-P S10-P 31.7 5KV 0.5 x 1 mm 14.8 13.4 1 5.2 Nominal load 5 A/250 V Dielectric strength 1 min. Coil terminals to contacts Hard brass tin-plated terminals Integrated hold-down clip Ø1.6 1.2 7.5 4 2.5 3.4 4 15 20 4.5 5 6 5 2.1 Ø1.6 7.5 7 IEC 61810 EN 60947 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 80 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 IRC Interface and General Applications S12 New I/O socket for IRC relays two pole, change-over contacts 5A New I/O socket with terminals in-line, for relays C12, C12G, C15 and C15G Both this socket and the S10-M are designed to get a homogeneous set with identical terminal disposition, which allows easy identification of the contacts set in each level and simpler wiring. Wiring Diagram 5(A2) 9(22) 3(12) 6(A2) 8(21) 2(11) 4(A1) 7(24) 1(14) Both A2 terminals allow a secure interconnection through external bridges among an unlimited number of these sockets or a mixture of S12 and the S10-M. The A2 terminal, free on both the first and last sockets, is used to connect the cable of common polarity. Specifications Dimensions - mm 20.5 Poles Two change-over contacts Nominal load 5 A/250V Insulation: Between coil and contacts 5 KV Between every terminal and DIN rail 5 KV Between adjacent contacts 3 KV Max. screw torque 1.2 Nm Wire in-lets multi-core capacity 22-14 AWG Solid wire or ferrule tips capacity 4 mm2 Solid terminals of zinc-plated brass Integrated hold-down clip Removable marking label 12.5 26 46.5 Ø6 Ø3.5 2 8 1 7 12 11 14 3 9 S12 6 4 22 21 24 5 A2 A2 A1 16.9 Ø2.8 39.5 3.4 M3 61 75 75 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 81 Notes: Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 82 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 TIMERS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 83 TIME CUBE 8 and 11-Pin, Time Cube The modules CT 2 and CT 3 are electronic timers that are designed to be inserted beween a standard plug-in relay and its socket, enabling the relay to be operated as a timer relay. The CT modules are able to accept any standard 8 or 11-Pin RELECO series C2 or C3 as well as those from any other supplier. The relay coil voltage must be in the range shown for each model. CT 2A CT 3A CT 2B CT 3B CT 2E CT 3E Off delay Blinker On delay The timing starts when S is switched off. The relay drops out at time (t). The relay blinks ON/OFF at time (t) when switch S is closed. First pulse, ON. The timing starts when the switch S is closed. The relay pulls in at the time (t). R R Function B Function A 10 (7) S 2 10 (7) S + 2-A30/S* .......9.5-18 V 2-A30/L ..........20-65 V 2-A30/M .......90-150 V 2-A30/U .....180-265 V CT CT CT CT 3-A30/S* .......9.5-18 V 3-A30/L ..........20-65 V 3-A30/M .......90-150 V 3-A30/U .....180-265 V 10 (7) 2 S t R S t CT CT CT CT Function E S R S ~ R ~ + R S t t t ~ + CT 2-B30/S* ........ 9.5-18 V CT 2-B30/L ........... 20-65 V CT 2-B30/H ........ 90-265 V CT 2-E30/S* ........ 9.5-18 V CT 2-E30/L ........... 20-65 V CT 2-E30/H ........ 90-265 V CT 3-B30/S* ........ 9.5-18 V CT 3-B30/L ........... 20-65 V CT 3-B30/H ........ 90-265 V CT 3-E30/S* ........ 9.5-18 V CT 3-E30/L ........... 20-65 V CT 3-E30/H ........ 90-265 V *All types are for AC/DC except “S” voltage range (only DC) CT2... (8-Pin) and CT3... (11-Pin) types with time range from 0.2 seconds to 30 minutes (range 30) Time Range Setting Range 30 Dimensions 7654 Dip - Sw 32 1 0.2-3 s 6 5 7 4 2-30 s 50 Time accuracy Repetition +0.5%/20 ms Supply voltage 1 ms / volt. Ambient temperature -0.25% / K Reset time (types E, W, B) <150 ms Reset time (types A, K) <200 ms Triggering time: AC, 80 ms; DC, 50 ms Ambient temperature -10°C to +60°C Transient protection IEC 255.4 Housing material Noryl SE1 (UL94 V-1) Protection class (DIN 40050) IP 40 Weight avg. 35 g 10 9 8 Specifications 8 3 0.2-3 min 9 2 1 11 10 2-30 min 35 12.5 24.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 84 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 TIME CUBE 8 and 11-Pin, Time Cube The modules CT 2 and CT 3 are electronic timers that are designed to be inserted beween a standard plug-in relay and its socket, enabling the relay to be operated as a timer relay. The CT modules are able to accept any standard 8 or 11-Pin RELECO series C2 or C3 as well as those from any other supplier. The relay coil voltage must be in the range shown for each model. CT 2K CT 3K CT 2W CT 3W One shot, aux. pulse One shot The relay turns ON with a pulse on the switch S and turns OFF at the time (t). The relay turns ON as switch S is closed and turns OFF at the time (t). R R Function W Function K 10 (7) S 2 + 2 S R S ~ 10 (7) S R S t CT CT CT CT 2-K30/S* ........ 9.5-18 V 2-K30/L ........... 20-65 V 2-K30/M ........ 90-150 V 2-K30/U ...... 180-265 V CT CT CT CT 3-K30/S* ........ 9.5-18 V 3-K30/L ........... 20-65 V 3-K30/M ........ 90-150 V 3-K30/U ...... 180-265 V ~ + t CT 2-W30/S* ......9.5-18 V CT 2-W30/L .........20-65 V CT 2-W30/H ......90-265 V CT 3-W30/S* ......9.5-18 V CT 3-W30/L .........20-65 V CT 3-W30/H ......90-265 V *All types are for AC/DC except “S” voltage range (only DC) CT2... (8-Pin) and CT3... (11-Pin) types with time range from 0.2 seconds to 30 minutes (range 30) Time Range Setting Range 30 Dip - Sw Dimensions 7654 32 1 0.2-3 s 6 5 7 4 2-30 s 50 Time accuracy Repetition +0.5%/20 ms Supply voltage 1 ms / volt. Ambient temperature -0.25% / K Reset time (types E, W, B) <150 ms Reset time (types A, K) <200 ms Triggering time: AC, 80 ms; DC, 50 ms Ambient temperature -10°C to +60°C Transient protection IEC 255.4 Housing material Noryl SE1 (UL94 V-1) Protection class (DIN 40050) IP 40 Weight avg. 35 g 10 9 8 Specifications 8 3 0.2-3 min 9 2 1 11 10 2-30 min 35 12.5 24.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 85 Notes: Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 86 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 RINT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 87 RINT Interface Modules RINT Relay and Accesories Part Number Key Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified. RINT interface relays consist of two components: • Relay • Socket Complete Relay Module (Relay and Socket 6.2 mm) Part Number Key RINT - X X / UC X Relay Interface Module V Nominal Voltage 24 V 230 V Socket Terminal Type Relay Contact Material 1 = AgSnO2 2 = AgSnO2 + min. 3µ Au 1 2 5 8 = = = = AgSnO2 AgSnO2 + min. 3µ Au Solid State N.O. 2 A DC 24 V Solid State N.O. 2 A AC 250 V Relay Part Number Key RINT - R X / UC X V Relay Interface Module Nominal Voltage Relay Contact Material 24 V 60-240 V 1 2 5 8 = = = = AgSnO2 AgSnO2 + min. 3µ Au Solid State N.O. 2 A DC 24 V Solid State N.O. 2 A AC 250 V Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 88 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 RINT Interface Modules RELAY + SOCKET DESCRIPTION RINT-11 / UC24V Screw terminal AgSnO2 RINT-21 / UC24V Cage clamp AgSnO2 RINT-11 / UC230V Screw terminal AgSnO2 RINT-21 / UC230V Cage clamp AgSnO2 RINT-12 / UC24V Screw terminal AgSnO2 +3µ Au RINT-22 / UC24V Cage clamp AgSnO2 +3µ Au RINT-12 / UC230V Screw terminal AgSnO2 +3µ Au RINT-22 / UC230V Cage clamp AgSnO2 +3µ Au RINT-15 / UC24V Solid State screw terminal, DC loads RINT-25 / UC24V Solid State cage clamp, DC loads RINT-18 / UC24V Solid State screw terminal, AC loads RINT-28 / UC24V Solid State cage clamp, AC loads RELAY DESCRIPTION RINT-R1/UC24V Relay module contacts AgSnO2 RINT-R1/UC60-240V Relay module contacts AgSnO2 + 3µ Au RINT-R2/UC60-240V Relay module contacts AgSnO2 + 3µ Au RINT-R5/DC24V Solid State relay module, DC loads RINT-R8/DC24V Solid State relay module, AC loads BRIDGES ACCESORIES RINT-BR1-500B Blue bridges (1 unit, 500 mm) RINT-BR1-500G Grey bridges (1 unit, 500 mm) RINT-BR2-06G/10 Grey bridges (10 units) RINT-BR2-06B/10 Blue bridges (10 units) RINT-BR2-06R/10 Red bridges (10 units) LABELS ACCESORIES RINT-MA6-0/100 Labels (100 units) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 89 RINT Interface Modules • Relay module up to 6 A 250 V, different contact material • Solid state modules DC, AC up to 2 A • Coil UC = AC/DC, not polarised, integrated freewheeling circuit • LED status display • Screw terminals or spring cage terminals • Optional coloured bridges for different connections • Narrow mounting 6.2 mm Connector bridge With screw terminals (1x0.2-2.5mm2) RINT-11, -12, -15, -18 With spring clamp terminals (1x0.2-2.5mm2) RINT-21, -22, -25, -28 RINT-11, RINT-21 RINT-12, RINT-22 Interface module Interface module Interface module Complete with integrated LED and switching module for PLC’s and process control. High power contact gSnO2. With screw terminals (RINT-11) or spring cage terminals (RINT-21). No external freewheeling circuit required. Bridges optional. Specially for PLC, process controls with DC currents. Contact AgSnO2+3µAu. With screw terminals (RINT-12) or spring cage (RINT22). No external freewheeling circuit required. Recommended max. load 250V 6A resistive. Bridges optional. MAX 6 A 250 V 6 A 250 V MIN 100 mA / 12 V 100 mA / 12 V Contact type/material Switching power AC1 Switching power DC1 24V/230V Switching power AC15 Peak inrush current Switching cycles: mech./elec. Isolation EN 61810-5 CO/AgSnO2 1500 W 140 W / 40 W NO 750 W / NC 375 W 10 A / 4 s 10x106 / 105 4 kV CO/AgSnO2 + 3µAu 1500 W 140 W / 40 W – 10 A / 4 s 10x106 / 105 4 kV Operation voltage AC50/60Hz/DC Power consumption Pmax. 24V/230V On delay/release time Temp.: operating/(storage) -20 to +100% 170 / 217 mW 5 ms / 2.5 ms -40°C to 80°C/-40°C to 85°C -20 to +100% 170 / 217 mW 5 ms / 2.5 ms -40°C to 80°C/-40°C to 85°C Prep. Technical data (Tamb 20°C) 24, 230 Ordering-No. UC 50/60Hz/ DC 24, 230 RINT-11/UC.....V RINT-21/UC.....V RINT-12/UC.....V RINT-22/UC.....V RINT-R1/UC60-240V RINT-R1/UC24V RINT-R2/UC60-240V RINT-R2/UC24V ≤10% Replacement Relay Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 90 B1201 www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 RINT Interface Modules Connector bridge: RINT-BR.... Relay module RINT-R1; RINT-R2 Label: MA6-0/100 Solid-state module RINT-R5; RINT-R8 RINT-15, RINT-25 RINT-18, RINT-28 Solid State Interface module Interface module for PLC’s and process control. DC solid state switch, type NO. For fast and high frequently switching. With screw terminals (RINT-15) or spring cage terminals (RINT-25). Bridges optional. for PLC’s and process control. AC output interface 0 synchronous switching NO for resistive or similar load. (No transformator rec.) With screw terminals (RINT-18) or spring cage terminals (RINT-28). Bridges optional. Order Example: Interface module RINT-21/UC24V Connector bridge RINT-BR2-6B/10 (packing unit: 1x10 pieces) Replacement relay RINT-R1/UC24V Accessories: 2 A 24 V 2 A 240V 0.05 mA / 12 V 25 mA / 12 V NO / Solide-state DC – 48 W – – – 2.5 kV NO / Solide-state AC (triac) 480 W – – 40 A / 20 ms – 2.5 kV Label: RINT-MA6-0/100 (100 pieces) Bridges: 500mm blue: RINT-BR1-500B (1 piece) 500mm grey: RINT-BR1-500G (1 piece) 6mm blue: RINT-BR2-6B/10 (10 pieces) 6mm grey: RINT-BR2-6G/10 (10 pieces) 6mm red: RINT-BR2-6R/10 (10 pieces) -37 to +25% 185 mW <60 µs / <600 µs -30°C to 80°C/-40°C to100°C 24, 230 -37 to +25% 185 mW <60 µs / <600 µs -30°C to 80°C/-40°C to100°C 24, 230 RINT-15/DC.....V RINT-25/DC.....V RINT-18/DC.....V RINT-28/DC.....V RINT-R5/DC24V RINT-R8/DC24V Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441 B1201 91 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Phone: (763) 553-7300 Fax: (763) 553-0708 Application Support: 1-800-544-7769 E-mail: [email protected] www.turck.us MEXICO TURCK MEXICO S. DE R.L. DE C.V. Carr. Saltillo-Zacatecas km 4.5 s/n Parque Industrial “La Angostura” Saltillo, COAH. C.P. 25070 Mexico Phone: +52 (844) 411-6650/46 Fax: +52 (844) 482-6926 Local Toll Free: 01-800-01-88725 E-mail: [email protected] CANADA CHARTWELL ELECTRONICS, INC. 140 Duffield Drive Markham, Ontario Canada, L6G 1B5 Phone: (905) 513-7100 Fax: (905) 513-7101 Toll Free: 1-877-513-7769 AUSTRALIA TURCK Australia Pty. Ltd. Unit 5, 6-7 Gilda Court Mulgrave, Victoria 3170 Australia Phone: (+61) 3 9560 9006 Fax: (+61) 3 9560 1620 Local Toll Free: 1300 132566 E-mail: [email protected] GERMANY WORLD HEADQUARTERS Hans TURCK GmbH & Co. KG Witzlebenstrasse 7 D-45472 Muelheim an der Ruhr Federal Republic of Germany Phone: (+49) 208-49 52-0 Fax: (+49) 208-49 52 264 www.turck.com USA ™ Printed in USA ©2010 by TURCK Inc. All rights reserved. No part of the publication may be reproduced without written permission. B1201 5/10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com