Submittal Data PC Series Carbon Dioxide Sensors Description Specifications The PC Series carbon dioxide sensors are designed to monitor carbon dioxide levels in rooms and ducts. General Range: 0 to 2,000 ppm factory default, adjustable to 10,000 ppm with PC1104 software kit Accuracy: +/- 75 ppm or 7% whichever is greater Response time: < 1 minute (0 to 90% FS) Warm up time: <2 minutes @77°F (25ºC) Guarantee: 5 year calibration guarantee The PC Series features: • 4 to 20 mA and 0 to 10 VDC outputs available simultaneously • Programmable relay output • Optional LCD display • Wall mount and duct aspiration versions • 0 to 2,000 ppm CO2 factory default range • Mounting plate with terminal block for quick and easy installation • ABC Logic™ self calibration system eliminates the need for manual calibration when indoor CO2 level drops to outside levels during unoccupied periods. Environmental Operating temperature: 60 to 90°F (15 to 32°C) Operating humidity: 0 to 95% RH, non-condensing Storage temperature: -40 to 158°F (-40 to 70°C) Electrical Supply voltage: 18 to 30 VAC RMS, 50/60 Hz halfwave rectified; 18 to 42 VDC polarity protected 1.75 VA max. average power, 2.75 VA peak power Analog output: 4 to 20 mA (500Ω max. load) 0 to 10 VDC (100Ω output impedance) both outputs available simultaneously Relay output: N.O. or N.C.; Form C, 2A@24 VAC or VDC, adjustable setpoint Specifications subject to change without notice. R 2800 LAURA LANE • MIDDLETON, WI 53562 • (800) 288-9383 • FAX (608) 836-9044 • www.tcsbasys.com 1 Ordering Information Part No. PC1001 PC1002 Description Carbon dioxide sensor, wall mount, no display, white Carbon dioxide sensor, wall mount, with display, white PC Series Accessories Hand-held carbon dioxide and temperature monitor Duct aspiration enclosure (for use with all wall mount sensors) Calibration kit for PC Series sensors Calibration and programming PC software Windows 95/98, 2000, NT (required to adjust output settings on all non-display models) Outside air enclosure (for use with all wall mount sensors) PC1101 PC1102 PC1103 PC1104 PC1105 Dimensions Note: inches [mm] PC1102 4.25" [107.95] 3.75" [95.25] 6.50" [165.10] 8.00" [203.20] 3.50" [88.90] 1.13" [28.70] 7.00" [177.80] 1.13" [28.70] and 1.07 [27.18] 0.88" [22.35] PC1001, PC1002 3.25" [82.55] 5.75" [146.05] CO2 1028 PPM PC1105 1.13" [28.70] 4.25" [107.95] 3.75" [95.25] 3.50" [88.90] 6.50" [165.10] 7.00" [177.80] 1.13" [28.70] and 1.07 [27.18] 0.88" [22.35] R 2800 LAURA LANE • MIDDLETON, WI 53562 • (800) 288-9383 • FAX (608) 836-9044 • www.tcsbasys.com 2 Rev. 1104