Transcript
FA 12-55
12V55Ah
Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications.
Application · Communication Equipment · Medical Equipment · Emergency Power System
· Telecom · Control Equipment · UPS
General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions
3mm (0.12inch)
14mm (0.55inch)
M6mm (0.24inch)
Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
Safety valve Terminal Separator Electrolyte
Lead dioxide Lead ABS ABS Epoxy Resin
...... ...... ...... ......
EPDR Copper AGM Sulfuric acid
Terminal Dimensions
105mm (4.13inch)
222mm (8.74inch)
277mm (10.9inch)
Battery Model
FA12-55
Designed Floating Life Capacity(20oC)
12 Years 20HR(2.9A,1.80V)
10HR(5.5A,1.80V)
1HR(34.5A,1.60V)
47Ah
34.5Ah
55Ah
58Ah Dimensions
5HR(9.4A,1.75V)
Length
Width
Height
Total Height
277mm(10.9inch)
105mm(4.13inch)
222mm(8.74inch)
222mm(8.74inch)
Approx. Weight
18Kg (39.7 lbs)
Internal Resistance
Full charged at 20oC: 0.008 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(10HR) Charge Voltage(20oC)
40oC 109%
25oC
0oC
100%
85%
Cycle use 14.1-14.4V(-30mV/ oC), max. Current: 13.75A
Page 1 of 2
-15oC 65% Float use 13.5-13.7V(-18mV/ oC)
FA 12-55
12V55Ah
Charge Voltage
(CA) (V/Cell)
(%) 120 100
0.25
Constant Charge at 0.25CA-2.35V (20oC) Charge Capacity
Charge Voltage
2.35 80
2.17 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Discharge Characteristic (20oC)
Charge Characteristic
Charge Current
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
Front Access SLA Battery
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
1.33 0
12
2
2.25
110 105
2.17
100 95 90
Capacity (%)
Battery Voltage (V/Cell)
3
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge
2.00
60
Min
Time(hour)
2.08
0.6CA
85 80 75 70 65 60 55 50
1.92
1.83
o
0
10
20
30
40
50
60
70
80
90
100
40 0
1
2
20oC
o
40 C
45
30 C 3 4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V
5 m in 19 3 17 3 16 4 14 6 13 2 10 0
10 m in 132 120 116 107 100 82 .0
1 5 m in 96 .3 93 .5 90 .2 85 .3 81 .4 70 .4
3 0m in 5 7 .8 5 6 .1 5 5 .0 5 3 .9 5 2 .3 4 8 .1
1h 3 4.5 3 4.4 3 4.3 3 4.0 3 3.5 3 3.2
3h 15 .3 15 .1 15 .0 14 .9 14 .8 14 .7
5h 9 .5 5 9 .4 9 9 .4 7 9 .3 9 9 .3 2 9 .2 4
10h 5 .83 5 .74 5 .70 5 .60 5 .50 5 .41
2 0h 3.0 0 2.9 8 2.9 5 2.9 3 2.9 0 2.7 4
1h 7 1.5 6 9.1 6 7.3 6 6.7 6 5.6 6 5.0
3h 28 .8 28 .6 28 .5 28 .4 28 .0 27 .9
5h 2 0 .4 2 0 .2 2 0 .1 1 9 .9 1 9 .5 1 9 .3
10h 1 1.7 1 1.5 1 1.4 1 1.2 1 1.0 1 0.8
2 0h 5.8 0 5.7 8 5.7 7 5.7 5 5.5 5 5.2 1
Constant power discharge ratings-watts at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V
5 m in 31 7 30 1 28 1 26 2 23 5 18 8
10 m in 219 216 211 197 183 152
1 5 m in 1 71 1 69 1 66 1 56 1 47 1 28
3 0m in 10 9 10 7 10 4 10 1 9 8 .5 9 0 .2
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2