Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

FA 12-100D 12V100Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Communication Equipment · Medical Equipment · Emergency Power System · Telecom · Control Equipment · UPS General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 5mm (0.20inch) 18mm (0.71inch) M6mm (0.24inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... Safety valve Terminal Separator Electrolyte Lead dioxide Lead ABS ABS Epoxy Resin ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 105mm(4.13inch) 287mm(11.3inch) 390mm(15.4inch) Battery Model FA12-100D Designed Floating Life 12 Years Capacity(20oC) Dimensions 20HR(5.29A,1.80V) 10HR(10A,1.80V) 5HR(17.2A,1.75V) 106Ah 100Ah 86.0Ah Length Width Height Total Height 390mm(15.4inch) 105mm(4.13inch) 287mm(11.3inch) 287mm(11.3inch) 66.0Ah Approx. Weight 33.5Kg (73.9 lbs) Internal Resistance Full charged at 20oC: 0.0063 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(66.0A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use 14.1-14.4V(-30mV/ oC), max. Current: 25A Page 1 of 2 Float use 13.5-13.7V(-18mV/ oC) FA 12-100D 12V100Ah Charge Voltage Constant Charge at 0.25CA-2.35V (20oC) (CA) (V/Cell) (%) 120 100 0.25 Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery Charge Current 0 2 4 6 8 10 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 0.6CA 2.08 2.00 85 80 75 70 65 60 55 50 1.92 1.83 45 0 10 20 30 40 50 60 70 80 90 40 0 100 o 1 2 20oC o 40 C 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 5min 10min 15min 30min 1h 3h 4h 5h 10h 20h 1.60V 350 240 175 105 66.0 26.0 20.0 17.7 10.6 5.53 1.67V 315 219 170 102 65.9 25.8 19.9 17.5 10.5 5.51 1.70V 299 211 164 100 65.7 25.7 19.8 17.4 10.4 5.50 1.75V 266 195 155 98.0 65.0 25.5 19.7 17.2 10.2 5.49 1.80V 240 181 148 95.0 64.2 25.2 19.5 17.0 10.0 5.29 1.85V 182 149 128 87.4 63.5 25.0 19.4 16.6 9.83 4.98 Constant power discharge ratings-watts at 20oC F.V/Time 5min 10min 15min 30min 1h 3h 4h 5h 10h 20h 1.60V 577 398 310 198 130 52.4 42.5 36.5 21.2 10.9 1.67V 547 393 307 194 126 52.2 42.3 36.3 20.9 10.7 1.70V 511 383 302 189 122 52.0 42.1 36.2 20.7 10.5 1.75V 476 358 284 184 121 51.6 41.9 36.1 20.4 10.3 1.80V 427 333 267 179 119 50.9 41.3 35.5 20.0 10.1 1.85V 342 276 233 164 118 50.7 40.9 35.0 19.7 9.86 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)