Control Pack Wiring Guide. MDPAK 1: DIVERTER PACK 1. MEP 2c N L1 2 3 4 2 3 1 A B 1 2 3 4 5 6 7 8 9 MCT1 (C.Stat) Wiring Centre. MWB16 0 Power Input. 230V ac E N 50Hz. (note 1) L 1 Pump. (note 2) Boiler (note 2) White. Orange. Grey. Blue. E N L MRT1 4 (Room Stat). 3 E N L MYSON MPE322 Note 1: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply voltage. To avoid electric shock, disconnect mains supply before doing any maintenance or installation work. To protect the system a fuse rated at 3 amps must be installed. To avoid electric shock installation or repair must be carried out by suitably qualified personnel and in accordance with current IEE regulations. Note 2: Refer to the boiler and pump manufacturers wiring instructions to determine their precise wiring requirements, with particular reference to pump "over-run" MZPAK 2: ZONE PACK 2. (Fully Pumped Zone Valve System) Blue. Grey. Orange. Brown. MEP 2c MYSON MPE222 (Hot Water) N L1 2 3 4 2 3 1 A B 1 2 3 4 5 6 7 8 9 0 Wiring Centre. MWB16 Power Input. 230V ac E N 50Hz. (note 1) L 1 3 E N L Pump. (note 2) Boiler (note 2) E N L MCT1 (C.Stat) Brown. Orange. Grey. Blue. MRT1 4 (Room Stat). MYSON MPE222 (Heating) Note 1: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply voltage. To avoid electric shock, disconnect mains supply before doing any maintenance or installation work. To protect the system a fuse rated at 3 amps must be installed. To avoid electric shock installation or repair must be carried out by suitably qualified personnel and in accordance with current IEE regulations. Note 2: Refer to the boiler and pump manufacturers wiring instructions to determine their precise wiring requirements, with particular reference to pump "over-run" MZPAK 3: ZONE PACK 3. (Gravity DHW Zone Valve System) Blue. Grey. White. Orange. Brown. MEP 2c MYSON MPE228 (Hot Water) N L1 2 3 4 2 3 MCT1 (C.Stat) 1 A B 1 2 3 4 5 6 7 8 9 Wiring Centre. 0 MWB16 Power Input. 230V ac E N 50Hz. (note 1) L 1 3 E N L Pump. (note 2) Brown. MYSON Orange. MPE222 Grey. Blue. (Heating) E N L Boiler (note 2) MRT1 4 (Room Stat). Note 1: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply voltage. To avoid electric shock, disconnect mains supply before doing any maintenance or installation work. To protect the system a fuse rated at 3 amps must be installed. To avoid electric shock installation or repair must be carried out by suitably qualified personnel and in accordance with current IEE regulations. Note 2: Refer to the boiler and pump manufacturers wiring instructions to determine their precise wiring requirements, with particular reference to pump "over-run" MZPAK 4: ZONE PACK 4. (MEGAFLO Zone Valve System) MEP 2c 1 2 34 5 6 MEGAFLO (connection box) (note 2) N L1 2 3 4 1 2 C E MEGAFLO MEGAFLO (cylinder stat.) (note 2) A B 1 2 3 4 5 6 7 8 9 0 Wiring Centre. MWB16 Power Input. 230V ac E N 50Hz. (note 1) L 1 3 E N L Pump. (note 2) Boiler (note 2) E N L Brown. Orange. Grey. Blue. MRT1 4 (Room Stat). MYSON MPE222 (Heating) Note 1: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply voltage. To avoid electric shock, disconnect mains supply before doing any maintenance or installation work. To protect the system a fuse rated at 3 amps must be installed. To avoid electric shock installation or repair must be carried out by suitably qualified personnel and in accordance with current IEE regulations. Note 2: Refer to the boiler and pump manufacturers wiring instructions to determine their precise wiring requirements, with particular reference to pump "over-run" MYSON CONTROLS, MYSON LTD., EASTERN AVENUE, TEAM VALLEY, GATESHEAD, TYNE & WEAR, NE11 0PG SALES OFFICE No.: 0845 402 3434 IN ACCORDANCE WITH OUR POLICY OF CONTINUAL PRODUCT IMPROVEMENT, WE RESERVE THE RIGHT TO AMEND THE SPECIFICATION OF THESE PRODUCTS WITHOUT PRIOR NOTIFICATION. SC1958: Revision 6. MZPAK 5: ZONE PACK 5. (MEGAFLO Zone Valve System) 1 2 34 56 MEP 2c MEGAFLO (connection box) (note 3) N L1 2 3 4 1 2 C E MEGAFLO MEGAFLO (cylinder stat.) (note 3) A B 1 2 3 4 5 6 7 8 9 0 Wiring Centre. MWB16 Power Input. 230V ac E N 50Hz. (note 2) L 1 3 E N L Pump. (note 3) Boiler (note 3) E N L Brown. Orange. Grey. Blue. White. MRT1 4 (Room Stat). MYSON MPE228 (Heating) Note 1. MZPAK5 is exactly the same as MAPAK4 except MPE228 replaces MPE222 and white wire is made safe Note 2: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply voltage. To avoid electric shock, disconnect mains supply before doing any maintenance or installation work. To protect the system a fuse rated at 3 amps must be installed. To avoid electric shock installation or repair must be carried out by suitably qualified personnel and in accordance with current IEE regulations. Note 3: Refer to the boiler and pump manufacturers wiring instructions to determine their precise wiring requirements, with particular reference to pump "over-run"