Transcript
Category 6A F/UTP AWG24 Horizontal Cable Spec Sheet
CommScope’s shielded Category 6A component compliant cable, is an unshielded cable surrounded by an overall metal foil, embedded in between synthetic tapes to guarantee stability of the cable structure after laying and foiling, using AWG24 Cu wires and a drain wire. When used in a channel, in conjunction with CommScope’s patch panels, patch cords and jacks, the cable provides superior Class EA link and channel performance for 10GBase-T application because of its finely tuned impedance match against CommScope’s connectivity. This Category 6A cable is available in a simplex (4 Pair) configuration with LSZH sheath, supplied on 500m reels, to suit all your installation requirements.
Key Features: • Shielded Category 6A component compliant cable in accordance with ISO/IEC 11801 and EN 50173 standards • Performance exceeding Category 6A specifications beyond 500MHz • Using AWG24 wires • LSZH sheet with IEC 60332-1 fire rating • Available in simplex construction • Fully interoperable and backwards compatible
1
For more information, visit commscope.com
Category 6A F/UTP AWG24 Horizontal Cable Spec Sheet
Technical Specifications Physical Characteristics Materials Conductors
24 AWG solid bare copper
Insulation
PE
Cross separator
Polyolefin
Drain wire
Tinned Copper
Tape
Synthetic foil
Cable screen
Alu/Polyester foil
Cable sheath
Low Smoke Zero Halogen
Drain wire
Tinned Copper
Dimensions and weight Nominal outer diameter
6.7mm
Cable weight simplex
48kg/km
Weight of loaded drum
27kg/500m
Palette size
1200mmx800mm
Mechanical Characteristics Bending radius during installation
≥ 50mm
Bending radius after installation
≥ 25mm
Tension during installation (simplex)
≤ 100N
Environmental Characteristics Operating temperature
-20°C ~ +60°C
Installation temperature
0°C ~ +50°C
Fire rating
IEC 60332-1-2
Toxicity
IEC 60754-1
Acid gas
IEC 60754-2
Smoke density
IEC 61034-2
Calorific Capacity
710 MJ/Km or 0.197 KWh/m
Electrical Characteristics at 20°C Conductors DC resistance (maximum)
190 Ω/km
DC resistance unbalance (maximum)
2%
Mutual capacitance (maximum)
16 nF/100m
Nominal velocity of propagation
78 %
Transmission performance Exceeding Category 6A requirements of: • ISO/IEC 11801 2nd edition • EN 50173-1 2nd edition • IEC 61156-5 Cat 6A • EN 50288-10-1
2
For more information, visit commscope.com
Category 6A F/UTP AWG24 Horizontal Cable Spec Sheet
Transmission characteristics Freq. MHz MHz
Attenuation Min. dB
1
Typ. dB
RL Min. dB
1,96
NEXT Typ. dB
Min. dB
35,7
PSNEXT
Typ. dB
Min. dB
109
Typ. dB
PSELFEXT Min. dB
95,4
Typ. dB 92,2
4
3,8
3,59
23
35,7
66,3
94,4
63,3
85,0
52,9
86,4
10
5,92
5,56
25
39,2
60,3
77,6
57,3
71,4
45,0
76,5
16
7,48
7,07
25
37,2
57,2
74
54,3
71,9
40,93
69,3
20
8,48
8,04
25
39,2
55,6
75,4
52,6
70,2
38,8
63,9
31,25
10,6
10,1
23,6
39,8
52,8
71,7
49,9
67,4
35,0
59,4
62,5
15
14,3
21,5
39 ,0
48,4
67,8
45,4
61,2
29,1
52,1
100
19,1
18,2
20,1
43,9
45,3
62,6
42,3
58,0
25,0
49,8
200
27,6
26,1
18
30,7
40,8
60,7
37,8
53,9
19,0
41,9
250
31,1
29,2
17,3
34,2
39,3
53,4
36,3
50,8
17,0
39,0
300
34,3
32,2
17,3
29,4
38,1
52,4
35,1
45,4
15,4
35,5
400
40,1
37,4
17,3
24,8
36,3
51,9
33,3
48,2
12,9
34,0
500
45,3
42,1
17,3
24,9
34,8
50,2
31,8
46,0
11,0
32,7
550*
47,7
44,1
22,6
53,6
43,1
27,5
N.B.: Specifications subject to change without notice. *For information only
Ordering Information Sheathing
Color
Type
Packaging
# Drums/Palette
Weight of Loaded Palette
Part Number
LSZH
white
4 pair
500m/reel
18
489kg
2153022-2
www.commscope.com Visit our website or contact your local CommScope representative for more information. © 2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS-322420-EU (12/15) previously 2153022-2