Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

DEEP CYCLE BATTERY KD12-230 FEATURES 12V230AH APPLICATION Low self-discharge and long shelf life Non-Spillable construction Safety valve installation for explosion proof Exceptional deep discharge recovery performance Solar system 99.7% pure lead calcium grids and A recognized Component of U.L Emergency Power System Telecommunications 4WD Dual Battery system Caravan, Motorhome systems SPECIFICATIONS Nominal Voltage 12V Nominal Capacity 230Ah@20 hour rate F.V.(1.80V/cell) Approx. Weight 61.50Kg (135.58lbs.) Terminals B9 (Fitting M8 bolt & nut) I3 is optional Internal Resistance ≤Ω 2.5m Max. Discharge Current 2000A (5 sec) 50A ISO9000 (Fully Charged) Charge: -10oC~40 oC (14 oF~104 oF) o o o o Discharge: -20 C~50 C (-4 F~122 F) o o o o Storage : -20 C~40 C (-4 F~104 F) Operating Temperature Range IEC 60896 .2 JIS C 8704.2 GB/T 19638.2 o Self Discharge 3% of capacity declined per month at (25 C) TERMINAL TYPE OUTER DIMENSIONS Length Terminal B9 11mm(0.43inch) 522±2 .0mm (20 .55±0.08inch) Width 28mm(1.1inch) Total Height B9: 243±2.0mm (9 .57±0.08inch) I3: 225±2.0mm (8 .86±0.08inch) 225mm(8.86inch) 219mm(8.62inch) Container Height 219±2 .0mm (8 .62±0.08inch) [M8 BOLT & NUT] 240mm(9.45inch) 522mm(20.55inch) 8.0mm(0.31inch) 9.0mm(0.35inch) 24mm(0.94inch) 240±2 . 0mm (9 .45±0.08inch) Terminal I3 Constant power discharge characteristics at 25°C/77°F M8mm(0.31inch) [M8 BOLT] Terminal Hardware Initial Torque:B9 Torque:B9 ,I3(5.5Nm I3(5.5Nm± 5%) 5%) Unit:W F.V/Time 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1.60V 1.65V 1.70V 1.75V 1.80V 796 786 766 716 666 620 614 604 568 534 396 388 378 368 358 260 251 245 243 238 105.0 105.0 105.0 103.0 102.0 73.0 73.0 73.0 72.2 71.0 44.6 43.9 43.5 42.9 42.3 24.2 24.0 23.6 23.2 22.8 Constant current discharge characteristics at 25°C/77°F 6mm(0.24inch) DIMENSION(mm/inch) Charge Voltage Max. Current Cycle use Max. Charge Current ISO 9001 14.4-14.7V (±4mV) 50A Unit:A F.V/Time 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1.60V 1.65V 1.70V 1.75V 1.80V 480 438 422 390 362 350 340 328 310 296 210 204 200 196 190 132 131 130 129 128 54.6 54.5 54.4 54.0 53.8 38.2 37.8 37.8 37.5 37.2 22.0 21.8 21.7 21.4 21.1 12.1 12.0 11.8 11.6 11.4 VISIT US AT WWW.KICKASSPRODUCTS.COM.AU Float Use 13.5-13.8V (±3mV) DEEP CYCLE BATTERY KD12-230 Charge Characteristic 0.20 2.60 120 0.17 2.40 100 0.14 10 80 60 40 20 0.11 0.08 0.05 0.02 Charge Vo ltage (V/Cell) 140 Charge Capacity (%) 100 Charge Current (CA) Trickle(or Float) Service Life Design Life (Years) 12V230AH Charge Voltage 2.20 Charge Capacity 2.00 . 1 Discharge 100%(0.05CA×20H) 50%(0.05CA×10H) 1.80 . 2 Charge 1.60 1.40 . Charge Voltage 13.65V (2.275V/Cell) Charge Current 0.1CA o Charge Current 0 10 20 30 40 50 0 60 0 0 0 o 8 4 Temperature ( C) 16 12 20 24 Charge Time (Hour) Discharge Characteristic Cycle Service Life o Terminal Voltage(V) 80 Cycle Life 60 40 20 o 25 C(77 F) 20oC(68oF) 13 100 Depth of Discharge (%) o 3 Temperature 25 C(77 F) 12 11 0.17C 0.09C 0.05C 10 0.25C 0.6C 9 8 3C 1C 2C 0 0 500 1000 1500 2000 2500 3000 3500 0 4000 1 2 3 5 10 20 30 60 2 3 5 Min Number of Cycle (Times) 10 20 30 Hour Discharge Time (Hour) Capacity Factors With Different Temperature Battery Type -20o C -10o C 0oC 5oC 10oC 20o C 25o C 30oC 40oC 45o C GEL Battery 6V&12V 55% 75% 85% 88% 90% 98% 100% 102% 104% 105% 2V 65% 80% 88% 90% 92% 99% 100% 103% 105% 106% AGM Battery 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109% 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110% VISIT US AT WWW.KICKASSPRODUCTS.COM.AU