Transcript
Arena Symphony AS235ZSB / 96239259 ARENA S T16 2X35 HF WL6 DSB 850 Times New Roman G5
35W T16
Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 2 x 35W T16 lamp(s). Electronic, fixed output control gear. Body: steel, white (close to RAL 9010). louvre: perforated highly reflective satinbrite aluminium. Electrical connection via 6 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 95 mm Total power: 76 W Weight: 22 kg
TLG_ARNS_F_DSBLOUVRE.jpg
180° 150°
150°
120°
90°
120°
300
200
100
90°
60°
60°
30° cd/klm
30° 0° TLG_SP_0040664.ldt
Lamp position: STD - standard Lamps: 2 x T16 / 35W Total luminous flux: 6600 lm Luminaire efficacy: 70 lm/W Colour Rendering Index min.: 80 LOR: 0,80 ULOR: 0,29 DLOR: 0,52
Lamp efficacy: 87 lm/W Ballast: 1x HF_ HF-S Connected Load: 76 W Lambda = 0.95 Dimming: Fixed output CELMA EEI: A2
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting
Arena Symphony AS235ZSB / 96239259 ARENA S T16 2X35 HF WL6 DSB 850 Times New Roman
180° 150°
150°
120°
90°
0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180°
120°
300
200
100
90°
60°
60°
30°
30°
cd/klm
C180 | C0 C270 | C90
0°
Light output ratio
Glare Evaluation
C0 231 233 239 248 253 250 243 226 202 156 105 67 34 11 1 0 0 0 0 7 13 18 22 27 36 45 54 65 76 83 88 93 97 99 99 98 97
C90 C180 C270 231 231 231 229 233 229 226 239 226 222 248 222 216 253 216 207 250 207 197 243 197 184 226 184 168 202 168 145 156 145 101 105 101 46 67 46 12 34 12 1 11 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 6 7 6 13 13 13 21 18 21 30 22 30 38 27 38 46 36 46 54 45 54 61 54 61 68 65 68 74 76 74 80 83 80 85 88 85 89 93 89 92 97 92 94 99 94 95 99 95 97 98 97 97 97 97
Classification
LOR
80 %
X= 4 H, Y= 8 H
ULOR
28 %
Reflection factors
70/50/20
EN
65°<3000cd/m²
DLOR
52 %
UGR transversal
<16
BZ
BZ1
UGR axial
<13
UTE
FFR
0.54 (35:65)
BLF
1.00
S = 1.00 H
LiTG
B53
0.52 C + 0.29 T
CIE Flux Codes
67 98 100 64 80
Utilization Factors Room Reflectance Ceiling/Walls/Floor
0.75
1.00
1.25
1.50
Room Index 2.00
2.50
3.00
4.00
5.00
70 / 50 / 20
NA
58
62
65
69
71
73
76
77
70 / 30 / 20
NA
53
58
61
65
68
71
73
75
70 / 10 / 20
NA
50
55
58
63
66
68
71
74
50 / 50 / 20
NA
53
56
59
62
64
66
67
69
50 / 30 / 20
NA
50
53
56
60
62
64
66
67
50 / 10 / 20
NA
47
51
54
58
60
62
65
66
30 / 50 / 20
NA
49
51
53
56
57
59
60
61
30 / 30 / 20
NA
46
49
51
54
56
57
59
60
30 / 10 / 20
NA
44
47
50
53
55
56
58
59
0/ 0/ 0
NA
39
42
43
45
47
47
48
49
According to CIBSE Technical Memorandum No. 5 1980
SHR Nom = SHR Max = SHR Max TR =
1.75 1.75 1.95
Photometric data file: TLG_SP_0040664.ldt
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting