Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Sun. Power. Life. ETATRACK active 600 Single-axis Tracking System for PV Modules Characteristics ƒƒ ƒƒ ƒƒ ƒƒ ƒƒ ƒƒ ƒƒ ƒƒ ƒƒ total module surface up to c. 6.0 m2 no failure-prone light sensor no unnecessary tracking movements low power consumption (c. 1 kWh/year) statics according to German and European standards high reliability and life-expectancy excellent serviceability cost-efficient tracking system assembly by one person possible Application ƒƒ single-axis tracking system for PV modules* ƒƒ additional energy yield of up to 40 % compared to fixed installations picture may differ from actual product Design max. 1.8 m Tracking Unit Control ƒƒ electronics incl. battery in plastic housing ƒƒ supply voltage: 12 V DC (nominal voltage) up to 50 Voc (open-circuit voltage), by one of the tracked modules** ƒƒ stepwise tracking, depending on the daily sunshine duration (length of day) ƒƒ South position in darkness ƒƒ synchronisation of multiple units possible ƒƒ standby mode in periods of low irradiation*** 30° 3.4 m 3.6 m 4.0 m .5 m x. 3 ma max. 1.16 m min. 0.8 m 2 m 2.3 m ƒƒ single-axis tracking system ƒƒ angle of second axis adjustable 0 – 50° in steps of 10° ƒƒ elevation East-West: 90° ƒƒ module surface up to c. 6.0 m2 max. dimensions of mounted frames (supportive area, installation area PV modules): width: 1.16 m, height: 3.5 m ƒƒ frame and pole: steel, hot-dip Zn-coated ƒƒ screw set: steel, Zn-coated ƒƒ module clamps made of stainless steel for mounting the PV modules using the holes in the module frame, incl. M6 stainless steel screw kits ƒƒ suitable for high wind speeds: statics according to German and European standards ƒƒ suitable for ground level installation ƒƒ low energy consumption: c. 1 kWh/year ƒƒ maintenance-free min. Ø 1.2 m or 1 m × 1 m Drive Included in Delivery ƒƒ DC linear drive ƒƒ maintenance-free ƒƒ kit tracking unit ƒƒ module clamps (cf. design): 28 sets per tracking unit for 7 PV modules ƒƒ fixation for optional PV module (5 or 10 Wp), incl. 2 sets module clamps** ƒƒ control ƒƒ drive ƒƒ installation manual Foundation ƒƒ concrete foundation with steel reinforcement (min. 1.2 m3) Storage and Operating Conditions ƒƒ ambient temperature range: –25 °C to +50 °C ƒƒ daily average ambient humidity: max. 80 % ƒƒ air salinity: max. 2 μg/m3, or distance from coast: min. 1 km ƒƒ altitude: –400 m to +3,000 m MSL ƒƒ for detailed description of ambient conditions for safe operation, cf. installation manual ƒƒ designs for other conditions on request Packing ƒƒ box 1: 1.18 × 0.34 m × 0.12 m, 55 kg ƒƒ box 2: 1.18 × 0.39 m × 0.14 m, 42 kg ƒƒ palletisable, standard EURO-pallet * for framed PV modules according to IEC 61215, UL 1703 ** for safe operation in specific system designs, an additional PV module (5 or 10 Wp) might be necessary, cf. installation manual *** for safe operation, cf. installation manual BERNT LORENTZ GmbH & Co. KG | Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de Errors excepted and possible alterations without prior notice. v100701