Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

DALI Sensor Antenna module LED indication Detection area Hold-time Daylight threshold Stand-by period Stand-by dimming level Daylight sensor Rotary coding switch DA1 DA2 Detection Pattern 0 6 DALI 6 Hold-time 2s~30min 2~50Lux This DALI sensor is designed for built-in lighting fixture, to be incoporated in the DALI system, taking command from the DALI master, accepting and carrying out the grouping work ,switching on/off, or dimming the assigned group members, and feed back the status oto the DALI master. Thanks to the rotary coding switch, it is easy to add in this sensor to the existing DALI system, and do the grouping work without the help of the DALI master and computer interface. Function and Options 1 3 Steps Dimming Control (Corridor Function) It offers 3 levels of light:100%-->dimmed light (5%, 10%, 20%, 50% optional)-->off; and 2 periods of selectable waiting time: motion holdtime and stand-by period; selectable daylight threashold and choice of detection area. With sufficient natural light, the fixture does not switch on when presence detected. With insufficient natural light, the sensor switches on the light automatically when person enters the room. People left, light dims to 5%,10%, 20%, 50% (optional ) stand-by level after the motion hold-time. Light switches off automatically after the stand-by period elapsed. Microwave motion sensor 30 Wiring Diagram DALI Group Selection DALI group configuration can be done either on PC, or on the rotary switch: 1. There are 16 channels available on the rotary switch. “0” is for DALI broadcast, the rest 15 channels is for end user to define the application unit. 2. PC grouping can overwrite rotary switch grouping, and vise-versa, the last setting stays in validity. 3. The rotary switch channel is corresponding to the groups listed below: Switch channel DALI group Switch channel DALI group 0 broadcast 8 group 7 1 group 0 9 group 8 2 group 1 A group 9 3 group 2 B group 10 4 group 3 C group 11 5 group 4 D group 12 6 group 5 E group 13 7 group 6 F group 14 Detection Pattern 0 9 50% 75% 6 0 10% 30% wall mounting height ceiling mounting height(m) 6 10% 30% 50% 75% 4 ceiling mounting pattern (m) 31 Microwave motion sensor wall mounting pattern (m) Settings 1 1 2 Detection area Detection area can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. 2 Hold-time Hold-time means the time period you would like to keep the lamp on 100% after the person has left the detection area. 3 I II III IV V VI VII Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. 8 Note: “0s” means on/off control; “+ ”means 2 steps dimming control, fixture never switches off. 5 1 2 3 Test 30s 1min 5min 10min 20min 30min I – 100% II – 75% III – 50% IV – 10% I – Test (2s) II – 30s III – 1min IV – 5min V – 10min VI – 20min VII – 30min 1 2 Daylight sensor The daylight threshold can be set on DIP switches, to fit for particular application. 4 100 % 75% 50 % 10% I II III IV I Disable II III IV 50Lux 10Lux 2 Lux 1 2 3 I II III IV V VI VII VIII 0s 10s 1min 5min 10min 30min 1h +∞ I – Disable II – 50Lux III – 10Lux IV – 2Lux I – 0s II – 10s III – 1min IV – 5min V – 10min VI – 30min VII – 1h VIII– +∞ 1 2 Stand-by dimming level This is the dimmed low light output level you would like to have after the hold-time in the absence of people. 5% 10% 20% 50% I II III IV I – 5% II – 10% III – 20% IV – 50% Technical Data 9.5~22.5VDC ( suitable DALI power supply) Input current Approx.10mA Group selection 16 groups via rotar y switch Detection area 10/50/75/100%, can be customized Hold-time Test/30S/1min/5min/10min/20min/30min, can be customized Stand-by period 0s/10s/1min/5min/10min/30min/1H/+ Stand-by dimming level 5%/10%/20%/50%, can be customized Daylight threshold 2~50Lux, disable, can be customized Microwave frequency 5.8GHz+/-75MHz Microwave power <0.05mW Detection range Max. (OxH): 12m x 6m Detection angle 30 ~150 Mounting height Max.6m Operating temperature -35 C ~ +70 C 8 Operating voltage o o , can be customized o o IP rating IP20 Certificate EMC, CE, R&TTE, SAA IP65(mounting in special box) Microwave motion sensor 32