AUXILIARY RELAYS FOR RAILWAY SECTOR.
This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products described here.
Moving together
INDEX 4.
›
Answers for railway applications
5.
›
General characteristics
6.
›
Technical standards
7.
›
Range of products
8.
›
Railway applications
9.
›
Instantaneous relays
16.
›
Time-Lag relays
18.
›
Latching relays
23.
›
Breaking capacity
28.
›
Pick-up voltage/release voltage-temperature charts
32.
›
Model selection
34.
›
Dimensions and panel mounting cut-off
.
Auxiliary relays | Railway sector
3
ANSWERS FOR RAILWAY APPLICATIONS ARTECHE auxiliary relays are designed to guarantee the best features and complete security even in the hardest working environment. The design, durability and quality of the different alternatives that ARTECHE relays can offer (FF range and standard range), make them suitable for high responsibility controls in the railway sector, highlighting:
ELECTRIFICATION: Traction Substations and Station Centres
› ›
Direct operation on MV / HV (circuit breaker, sectionalizer).
› › › ›
Applications where high speed operation is a must.
Galvanic isolation between the control system and the primary equipment. Applications where high breaking capacity is required. Tripping functions. Contact multiplication in control systems of HV / MV installations.
FF RANGE IN THE FOLLOWING APPLICATIONS:
ROLLING STOCK: › › › › › › ›
Boarding doors locking. Brake circuit command. Security loop. Pantograph control. Lighting and air conditioned systems operation. Traction system. Brake systems
INTERLOCKING AND SIGNALLING: Interface between infrastructure and rolling stock:
› › › › › ›
4
ASFA systems. RTMC systems. RTMS systems. CBTC systems. ETCS systems. ATO/ATP/ATS/APR… systems
Auxiliary relays | Railway sector
GENERAL CHARACTERISTICS The main features of ARTECHE’s auxiliary relays are the followings:
› ›
Security contacts (EN 50205 Standard).
›
Capable to operate under low duty loads, activate digital inputs, and operate without any load. FF Range.
›
Wide range of auxiliary voltage levels (Vdc and Vac).
› › › ›
Sturdy design.
›
High level of electrical insulation between input and output circuits.
›
Availability of extended voltage range (+25/-30%) for high security applications.
›
An internal diode is included to avoid damaging the relay when connecting with inverse polarity.
›
In compliance with the most demanding test standards: IEC, EN, IEEE and bearing the CE mark
›
High protection degree (IP40), with transparent cover, making them suitable for use in salty and tropical atmospheres.
›
Capable to work under ambient of 100% humidity.
›
Simplicity of installation (plug-in relays in a wide range of sockets with different installation configurations).
›
No need of maintenance after installation.
Capable to withstand vibrations and seismic conditions (EN 61373; IEEE 344; IEEE 323; IEEE C37.98 Standards).
High speed operation (up to 3 ms). Self-cleaning contacts. Designed to allow continuous operation even in high temperature ambient, within the whole voltage range.
In addition, the different number of alternatives that are offered when the equipment is selected, both technically (increase of the breaking capacity by serial contacts or by the magnetic blow out, high speed operation of the output contacts, possibility of adding different options to the relay) and in the assembly method (front, rear or flush mounted sockets, with screws or fastons) must be considered.
Auxiliary relays | Railway sector
5
TECHNICAL STANDARDS RAILWAY APPLICABLE STANDARDS ›
EN 60077 Series. Rolling stock equipment. - Part 1: General conditions in service and general terms. - Part 2: Electrotechnical components.
›
IEC 50155 (IEC 60571 equivalente). Railway applications - Rolling stock equipment.
› › ›
IEC 61373. Railway applications - Shock and vibration tests. NFF 16-101 and NFF 16-102. Rolling stock fire behaviour. EN 50205. Relays with forcibly mechanically guided contacts.
GENERAL STANDARDS In addition to the specific applicable standards, ARTECHE auxiliary relays are designed based on the fulfilment of the following standards:
› › › › ›
IEC 61810: Electromechanical all-or-nothing relays. IEC 60255: Electrical relays. Measuring relays and protection equipment. IEC 61812: Specified time relays for industrial use. IEC 60947: Low-voltage switchgear and controlgear. . IEC 61000: Electromagnetic compatibility.
E322124 UL Recognized Component Marks for USA and Canada: The combined UL signs for the USA and Canada are recognized by the authorities of both countries. All auxiliary relays identified with this mark meet the requirements of both countries.
6
Auxiliary relays | Railway sector
RANGE OF PRODUCTS ROLLING STOCK / SIGNALLING Instantaneous, latching and timer relays.
Auxiliary relays with seismic characteristics ARTECHE’s auxiliary relays with seismic characteristics are designed to work properly perform under frequent vibration and shock applications, as railway sector, or because of safety requirements as nuclear power plants. They comply with the extended voltage range (+25 / -30 %). The sturdy design of our equipment, with a higher appropriate pressure between contacts, permits to withstand vibrations without penalizing the good performance of the relays.
SIGNALING Instantaneous relays. The FF range exhaustive process control ensures a proper operation of the contacts in weak loads or even in no load operations.
ELECTRIFICATION Instantaneous, latching and timer relays.
General purpose auxiliary relays ARTECHE’s general purpose auxiliary relays are designed to directly operate to the tripping and control circuit. Their pick-up time lower than 20 ms and the high breaking capacity of their contacts make them appropriate to be used as an interface between the protection system and the breaker. Furthermore, its multiple output contacts permit to use these relays in control, interlocking, timing and signalling applications as well as per direct operation on HV and MV primary equipment.
Auxiliary tripping relays ARTECHE offers specific relays intended to be used in tripping applications, where the requirements of pick-up time (with models that assure the trip even in less than 3 ms) and the breaking capacity are demanding, as the trip of HV and MV breakers. These relays include a standard front LED that indicates when the relay is energized. Relay trip flag is available, which indicates when the relay has operated, as a memory state. All the relays include a diode in parallel with the coil (see auxiliary relays with overvoltage protection characteristic) and comply with the shock and vibration standards, related to the relays with seismic characteristics.
Auxiliary relays with coil overvoltage protection ARTECHE’s auxiliary relays, either Vdc or Vac, have the possibility of including an element in parallel with the coil (diode or varistance). In applications with overvoltage, where drop-out time is not important, it is recommended to use diode. Otherwise, varistance is more suitable. These elements are aimed to discharge the energy of the coil when the relay is not longer energized. These relays are indicated when the customer wish to protect the contact of the equipment that commands the operation of our relay, providing a longer durability of the whole protection and control system. Auxiliary relays | Railway sector
7
RAILWAY APPLICATIONS MODEL
ROLLING STOCK (FF Range)
SIGNALING (FF Range)
INFRASTRUCTURE
CONTACTS
WELD NO TRANSFER CONTACTS
RD-2SY
•
•
•
2 CO
•
RF-4SY
•
•
•
4 CO
•
RJ-8SY
•
•
•
8 CO
•
RD-2SYDI / RD-2SYV
•
•
•
2 CO
•
RF-4SYDI / RF-4SYV
•
•
•
4 CO
•
RJ-8SYDI / RJ-8SYV
•
•
Instantaneous
•
•
8 CO
RD-2
•
•
2 CO
•
RF-4
•
•
4 CO
•
RJ-8
•
•
8 CO
•
RD-2DI / RD-2V
•
•
2 CO
•
RF-4DI / RF-4V
•
•
4 CO
•
RJ-8DI / RJ-8V
•
•
8 CO
•
Timers
TDF-2
•
•
•
2 CO
•
TDF-4
•
•
•
4 CO
•
TDF-22
•
•
•
4 CO (2 inst. + 2 timed)
•
TDJ-8
•
•
•
8 CO
•
TDJ-44
•
•
•
8 CO (4 inst. + 4 timed)
•
BF-3
•
•
•
3 CO
BF-4
•
•
•
4 CO
BJ-8
•
•
•
8 CO
BF-3BB
•
•
•
3 CO
BF-4BB
•
•
•
4 CO
BJ-8BB
•
•
•
8 CO
RD-2R
•
•
2 CO
•
RD-2XR
•
•
2 CO
•
RF-4R
•
•
4 CO
•
RF-4XR
•
•
4 CO
•
RJ-8R
•
•
8 CO
•
RJ-8XR
•
•
8 CO
•
BF-3R
•
•
3 CO
BF-4R
•
•
4 CO
BF-4RP
•
•
4 CO
BJ-8R
•
•
8 CO
BJ-8RP
•
•
8 CO
Latching
Trip
FF Range: Capable to operate under low duty loads, activate digital inputs, and operate without any load: general applications, as for rolling stock as for signaling.
8
Auxiliary relays | Railway sector
TECHNICAL FEATURES PER MODEL
› World-class range of
auxiliary relays for energy sector, specially designed for the most demanding applications
Auxiliary relays | Railway sector
9
GENERAL PURPOSE INSTANTANEOUS RELAYS Model
RD-2
RF-4
Applications
RJ-8
Operate directly to the tripping and control circuit.
Construction characteristics Contacts no.
2 Changeover
4 Changeover
8 Changeover 10 1
3 Connections
7
(–) 1 3
5 8
4
6
(–) a
12
(–) 1
(+) 2
2
11 7
4
8 13
5
9
(+) 2
(+) d
14 6
3
31 40
4
41 50
5
51 60 61 70 71 80
6
10
7 8 Options
With OP options
Weight (g) Dimensions (mm)
11 20 21 30
81
With OP options - Push-to-test button included
125
250
500
22,5 x 50,4 x 72
42,5 x 50,4 x 72
82,5 x 50,4 x 72
Coil characteristics 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 Vac (50-60 Hz)(4)
Standard voltages(1) Voltage range
+10% -20% UN
Pick-up voltage See pick-up/release voltage-temperature curves
Release voltage Consumptions in permanence (UN)
2,6 W; 3,3 VA
3,9 W; 6,6 VA
6 W; 11 VA
Operating time Pick-up time
<20 ms
Drop-out time
Vdc: <10 ms • Vac: <50ms With LED: <50ms
Vdc: <15 ms • Vac: <50 ms With LED: <50 ms
Contacts Contact material
AgNi ≤30 mΩ / ≤15 mΩ (Range FF)
Contacts resistance
(2)
Distance between contacts
1,8 mm
Permanent current
10 A
Instantaneous current
30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity
See breaking capacity curves (Contact configuration type A)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC <2000 m
Operating altitude(3) (1) (2)
Other voltage upon request Guarantee data for relays just manufactured
10
(3) (4)
Ask for higher altitudes Voltage not recognized by UL
Auxiliary relays | Railway sector
TRIP RELAYS (I) Model
RD-2R
RD-2XR
RF-4R
RF-4XR
Applications
Intended for tripping applications where high demanding requirements in operating time (with tripping time from 8ms to 3 ms) and breaking capacity are needed, that is the case of tripping HV and MV circuit breakers.
Construction characteristics Contacts no.
2 Changeover
(–) 1
4 Changeover 11 7 3 (–) 1 12
7 5
3
4
8 13
5
9 14
6
10
8 Connections
6
4 (+) 2
(+) 2
With 0P options • LED included • Diode in parallel with the coil included
Options Weight (g) Dimensions (mm)
125
250
22,5 x 50,4 x 72
42,5 x 50,4 x 72 (F short Type)
Coil characteristics Standard voltages(1)
24, 48, 110, 125, 220, 250 (4) Vdc /110, 127, 230 Vac (50-60Hz)
24, 48, 110, 125, 220, 250 (4) Vdc / 110, 127, 230 Vac (50-60 Hz)
24, 48, 110, 125, 220, 250 Vdc
Voltage range
24, 48, 110, 125, 220, 250 (4) Vdc
+10% -20% UN
Pick-up voltage See pick-up/release voltage-temperature curves
Release voltage Consumptions
1W
0,95 W In permanence (UN) Peak • ≤96 Vdc
0,8 A / 20 ms
2,5 A / 20 ms
Peak • >96 Vdc
0,3 A / 20 ms
0,8 A / 20 ms
0,8 A / 20 ms 0,3 A / 20 ms
2,5 A / 20 ms 0,8 A / 20 ms
Operating time Pick-up time Drop-out time
<8 ms (<10 ms Vac)
<5,5 ms
<8 ms (<10 ms Vac)
<5,5 ms
Vdc: <40 ms Vac: <50 ms
Vdc: <40 ms
Vdc: <40 ms Vac: <50 ms
Vdc: <40 ms
Contacts Contact material
AgNi
Contacts resistance
≤30 mΩ
Distance between contacts
1,2 mm
(2)
Permanent current
10 A
Instantaneous current
30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity
See breaking capacity curves (Contact configuration type B)
Max. breaking capacity
See value for 50.000 operations
Umax opened contact
250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-25ºC +70ºC
Storage temperature
-30ºC +70ºC
Max. operating humidity
93% / +40ºC <2000 m
Operating altitude(3) (1) (2)
Other voltage upon request Guarantee data for relays just manufactured
Auxiliary relays | Railway sector
(3) (4)
Ask for higher altitudes Voltage not recognized by UL
11
TRIP RELAYS (II) Model
RJ-8R
RJ-8XR
RJ-4XR4
Intended for tripping applications where high quality requirements in operating time (with models even tripping in less than 3 ms) and breaking capacity are needed, that is the case of tripping HV and MV circuit breakers.
Applications Construction characteristics
10 11 20 21 30 31 40 41 50 51 60 61 70 71 80 81
1 2 (–) a
Connections
3 4
(+) d
5 6 7 8
Options
(+) d
8
80 81 70 71 60 61 50 51 40 41 30 31 20 21 10 11
7 6 5 4 3 2 (-) a
1
Alto poder de corte
4 Changeover + 4 Fast Singles-Inversors without break power
8 Changeover
Disparo
Contacts no.
With 0P options • LED included • Diode in parallel with the coil included
Weight (g) Dimensions (mm)
500
335
82,5 x 50,4 x 72 (J short type)
42,5 x 50,4 x 82,5 (F short Type)
Coil characteristics Standard voltages(1)
24, 48, 110, 125, 220, 250 (4) Vdc/110, 127, 230 Vac (50-60 Hz)
Voltage range
110, 125, 220, 250
24, 48, 110, 125, 220, 250(4) Vdc
+10% -20% UN
(4)
Vdc
+15% -20% UN
Pick-up voltage See pick-up/release voltage-temperature curves
Release voltage Consumptions
1,4 W
6,5 W
In permanence (UN) Peak • ≤96 Vdc
0,8 A / 20 ms
2,5 A / 20 ms
Peak • >96 Vdc
0,3 A / 20 ms
0,8 A / 20 ms
25 W / 5 ms
Operating time Pick-up time
<8 ms Vdc (<10 ms Vac) (Range 24 Vdc <10 ms)
Drop-out time
<6,5 ms
Vdc: <40 ms Vac: <50 ms
Contacts 1-4: <3 ms Contacts 5-8: <20 ms
Vdc: <40 ms
Contacts 1-4: <25 ms Contacts 5-8: <50 ms
Contacts Contact material
AgNi
Contacts 1-4: AgNi 10 Contacts 5-8: Ag1000 ≤30 mΩ
Contacts resistance(2) Distance between contacts
1,2 mm
Distance between contacts
10 A
Instantaneous current
Contacts 5-8: 1,2 mm Contacts 5-8: 15 A Contacts 1-4: 8 A
30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity
See breaking capacity curves (Contact configuration type B)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-25ºC +70ºC
Storage temperature
-30ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(3) (1) (2)
12
Other voltage upon request Guarantee data for relays just manufactured
<2000 m (3) (4)
Ask for higher altitudes Voltage not recognized by UL
Auxiliary relays | Railway sector
INSTANTANEOUS RELAYS WITH SEISMIC CHARACTERISTICS Model
Applications
RD-2SY
RF-4SY
RJ-8SY
Frequent vibration and shock applications, as railway sector, or because of safety requirements as nuclear power plants.
Construction characteristics Contacts no.
2 Changeover
4 Changeover
11 Connections
3 7
(–) 1 3
5 8
Weight (g) Dimensions (mm)
8 13
5
9
6
14 10
(+) 2
With OP options
7 12
4
6
4 (+) 2
Options
(–) 1
8 Changeover 10 11 1 20 21 2 30 (–) a 31 3 40 41 4 50 (+) d
5 6
51 60 61 70
7
71 80
8
81
With OP options / Push-to-test button included
125
250
500
22,5 x 50,4 x 72
42,5 x 50,4 x 72
82,5 x 50,4 x 72
Coil characteristics Standard voltages(1)
24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)
Voltage range
+25% -30% UN
Pick-up voltage Release voltage Consumptions in permanence (UN)
See pick-up/release voltage-temperature curves 2,6 W; 3,3 VA
3,9 W; 6,6 VA
6 W; 11 VA
Operating time Pick-up time Drop-out time
< 20 ms Vdc: <10 ms / Vac: <50 ms / With LED
Vdc: <15 ms / Vac: <50 ms / With LED
Contacts Contact material Contacts resistance(2) Distance between contacts Permanent current Instantaneous current Max. making capacity Breaking capacity Max. breaking capacity Umax opened contact
AgNi ≤30 mΩ / ≤15 mΩ (FF Range) 1,2 mm 10 A 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms 40 A / 0,5 s / 110 Vdc See breaking capacity curves (Contact configuration type B) See value for 50,000 operations 250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(3)
<2000 m
Other voltage upon request Guarantee data for relays just manufactured Ask for higher altitudes (4) Voltage not recognized by UL (1)
(2)
(3)
Auxiliary relays | Railway sector
13
INSTANTANEOUS RELAYS WITH COIL OVERVOLTAGE PROTECTION (I) RD-2DI RD-2V (4)
Model
RF-4DI RF-4V (4)
RJ-8DI RJ-8V (4)
Intended to protect the contact of the equipment that feeds the coil in our relay.
Applications Construction characteristics Contacts no.
2 Changeover
4 Changeover
8 Changeover 10 1 11
(–) 1 Connections
7 5
3
3
7 12
4
8
(–) 1
8 5
9 14
6
10
(+) 2
(+) 2
3 4
13
6
4
2 (–) a
(+) d
5 6 7 8
Options
With OP options
Weight (g) Dimensions (mm)
11 20 21 30 31 40 41 50 51 60 61 70 71 80 81
With OP options / Push-to-test button included
125
250
500
22,5 x 50,4 x 72
42,5 x 50,4 x 72
82,5 x 50,4 x 72
Coil characteristics 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)
Standard voltages(1) Voltage range
+10% -20% UN
Pick-up voltage See pick-up/release voltage-temperature curves
Release voltage Consumptions in permanence (UN)
2,6 W; 3,3 VA
3,9 W; 6,6 VA
6 W; 11 VA
Operating time Pick-up time
< 20 ms
Drop-out time
V Series: <25ms DI Series: <50 ms
Contacts Contact material
AgNi ≤30 mΩ / ≤15 mΩ (FF Range)
Contacts resistance(2) Distance between contacts
1,8 mm
Permanent current
10 A
Instantaneous current
30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity
See breaking capacity curves (Contact configuration type A)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC <2000 m
Operating altitude(3) (1) (2)
14
Other voltage upon request Guarantee data for relays just manufactured
(3) (4)
Ask for higher altitudes Voltage not recognized by UL
Auxiliary relays | Railway sector
INSTANTANEOUS RELAYS WITH COIL OVERVOLTAGE PROTECTION (II) RD-2SYDI RD-2SYV (4)
Model
RF-4SYDI RF-4SYV (4)
RJ-8SYDI RJ-8SYV (4)
Frequent Vibration and Shock applications, as railway sector, or because of safety requirements as nuclear power plants. Intended to protect the contact of the equipment that feeds the coil in our relay.
Applications Construction characteristics Contacts no.
2 Changeover
4 Changeover
8 Changeover 10 1 11
(–) 1 Connections
7 5
3
3
7 12
4
8
(–) 1
8 5
9 14
6
10
(+) 2
(+) 2
3 4
13
6
4
2 (–) a
(+) d
5 6 7 8
Options
With OP options
Weight (g) Dimensions (mm)
11 20 21 30 31 40 41 50 51 60 61 70 71 80 81
With OP options / Push-to-test button included
125
250
500
22,5 x 50,4 x 72
42,5 x 50,4 x 72
82,5 x 50,4 x 72
Coil characteristics 24, 48, 72, 110, 125, 220 Vdc 24, 48, 63,5, 110, 127, 230, 400 (4) Vac (50-60 Hz)
Standard voltages(1) Voltage range
+25% -30% UN
Pick-up voltage See pick-up/release voltage-temperature curves
Release voltage Consumptions in permanence (UN)
2,6 W; 3,3 VA
3,9 W; 6,6 VA
6 W; 11 VA
Operating time Pick-up time
< 20 ms
Drop-out time
V Series: <25ms DI Series: <50 ms
Contacts Contact material
AgNi ≤30 mΩ / ≤15 mΩ (FF Range)
Contacts resistance(2) Distance between contacts
1,2 mm
Permanent current
10 A
Instantaneous current
30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity
See breaking capacity curves (Contact configuration type A)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Perfomance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC <2000 m
Operating altitude(3) (1) (2)
Other voltage upon request Guarantee data for relays just manufactured
Auxiliary relays | Railway sector
(3) (4)
Ask for higher altitudes Voltage not recognized by UL
15
TIME-LAG RELAYS (I) Model
TDF-2
TDF-4
Applications
TDF-22
Electrical command timing
Construction characteristics Timing Contacts no.
2 Changeover
4 Changeover
2 Changeover
Instantaneous contact no.
0 Changeover
0 Changeover
2 Changeover
B1 1 Connections 5 6
A1 2 + 13 9 14 TEMP 10
A1
B1
A1
B1
2 -
1 + 11 7 12 8 13 TEMP 9 14 10
2 -
1 +
3 4 5 6
Options
3 4 5 6
11 7 12 INST 8 13 9 14 TEMP 10
With OP options
Weight (g)
265
Dimensions (mm)
42,5 x 50,4 x 96,6
Coil characteristics 24, 48, 72, 96, 110, 125, 250 (4) Vdc/Vac (50-60 Hz)
Standard voltages(1)
+25% -30% UN (except range 250) (4)
Voltage range Pick-up voltage
See power supply-temperature charts for time-lag relays
Release voltage
≤3,2 W
Consumptions In permanence (UN)
≤4 W
≤5,5 W
Operating time Time range
between 0,03 s y 99 h
Pick-up time
< 23 ms
Drop-out time
< 40 ms
Contacts Contact type
2 Changeover
Contact material
4 Changeover AgNi (FF Range) ≤30 mΩ / ≤15 mΩ (FF Range)
Contact resistance(2) Distance between contacts
1,2 mm
Permanent current
10 A
Instantaneous current
30 A 0 A during 1s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc 30 A / 1 s / 36 Vdc / 30.000 operations (1 op / 15 s)
Breaking capacity
See breaking capacity curves (Contact configuration type B)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC <2000 m
Operating altitude(3) (1) (2)
16
Other voltage upon request Guarantee data for relays just manufactured
(3) (4)
Ask for higher altitudes Voltage not recognized by UL
Auxiliary relays | Railway sector
TIME-LAG RELAYS (II) Model
TDJ-8
Applications
TDJ-44
Electrical Command Timing
Construction characteristics Timing Contacts no.
8 Changeover
4 Changeover
Instantaneous contact no.
0 Changeover
4 Changeover
a c 1 Connections
2 3 4 5 6 7 8
d + b + 10 11 20 21 30 31 40 41 50 51 60 61 70 71 80 81
Options
a c 1 2 3 4 TEMP
5 6 7 8
d + b + 10 11 20 21 30 INST 31 40 41 50 51 60 61 70 71 TEMP 80 81
With OP options
Weight (g)
500
Dimensions (mm)
82,5 x 50,4 x 96,6
Coil characteristics Standard voltages(1)
24, 48, 72, 96, 110, 125, 250 (4) Vdc/Vac (50-60 Hz)
Voltage range
+25% -30% UN (except range 250 (4): +10% -20%))
Pick-up voltage
See power supply-temperature charts for time-lag relays
Release voltage Consumptions Permanencia (UN)
≤10 W
≤7,5 W
Operating time Time Range
between 0,03 s y 99 h
Pick-up time
<23 ms
Drop-out time
<40 ms
Contacts Contact type
8 Changeover
AgNi (Gama FF)
Contact material
≤30 mΩ / ≤15 mΩ (FF Range)
Contact resistance (2) Distance between contacts
1,2 mm
Permanent current
10 A
Instantaneous current
30 A 0 A during 1s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc 30 A / 1 s / 36 Vdc / 30.000 operations (1 op / 15 s)
Breaking capacity
See breaking capacity curves (Contact configuration type B)
Max. breaking capacity
See value for 50,000 operations
Umax opened contact
250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(2) Other voltage upon request (2) Guarantee data for relays just manufactured (1)
Auxiliary relays | Railway sector
<2000 m Ask for higher altitudes (4) Voltage not recognized by UL (3)
17
GENERAL PURPOSE LATCHING RELAYS Model
Applications
BF-3
BF-4
BJ-8
Relays with two stable positions. Required when the position memory (open-close, automatic-manual, local-remote...) is needed.
Construction characteristics Contacts no.
3 Changeover
4 Changeover
8 Changeover 11 10 21
Connections Set + 14 10 + 2 1 Reset
9 13 8 12 7 11
5 Set
4
2
3
Options Weight (g) Dimensions (mm)
+ B1 + 1 Reset
10 14 9 13 8 12 7 11
20 31 30 41 40 51 50
6 Set + a b + c d Reset
5 4 3
61 60 71 70 81 80
Options are not available 300
600
45 x 45 x 96,5 (F short Type)
90 x 50 x 100,5 (J short Type)
1 2 3 4 5 6 7 8
Coil characteristics Standard voltages(1)
24, 48, 72, 110, 125, 220 Vdc / 63,5, 110, 127, 230 Vac (50-60 Hz)
Voltage range Pick-up voltage Consumptions only in the change-over
+25% -30% UN See pick-up voltage / temperature curves for Latching relays ≤6 W
≤12 W
Operating time Pick-up time
<20 ms
Contacts Contact material Distance between contacts Permanent current Instantaneous current Max. making capacity Breaking capacity Max. breaking capacity Umax opened contact
AgNi 1,8 mm 10 A 80 A during 200 ms / 200 A during 10 ms 40 A / 0,5 s / 110 Vdc See breaking capacity curves (Contact configuration type A) See value for 50.000 operations 250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(2)
(1) (2)
<2000 m
Other voltage upon request Ask for higher altitudes
18
Auxiliary relays | Railway sector
TRIP AND LOCKOUT RELAYS (I) Model
Applications
BF-3R
BF-4R
BJ-8R
Intended for trip and lockout applications where high demanding requirements in operating time and breaking capacity are needed.
Construction characteristics Contacts no.
3 Changeover
Set Connections
10 1 Reset
9 + 13 14 8 + 12 2 7 11
4 Changeover
Set
5 4
2
3
Reset
Options
11 10 21 20 31 30 41 40 51 50 61 60 71 70 81 80
6 Set + a b + d c Reset
5 4 3
1 2 3 4 5 6 7 8
Options are not available
Weight (g) Dimensions (mm)
+ B1 + 1
10 14 9 13 8 12 7 11
8 Changeover
300
600
45 x 45 x 96,5 (F short Type)
90 x 50 x 100,5 (J short Type)
Coil characteristics Standard voltages(1)
24, 48, 72, 110, 125, 220 Vdc / 63,5, 110, 127, 230 Vac (50-60 Hz)
Voltage range Pick-up voltage Consumptions only in the change-over
+10% -20% UN See pick-up voltage / temperature curves for Latching relays 27 W
23 W
35,5 W
Operating time Pick-up time
<10 ms (Vdc) <20 ms (Vac)
<10 ms (Vdc) <20 ms (Vac)
Contacts Contact material Distance between contacts Permanent current Instantaneous current Max. making capacity Breaking capacity Max. breaking capacity Umax opened contact
AgNi 1,8 mm 10 A 880 A during 200 ms / 200 A during 10 ms 40 A / 0,5 s / 110 Vdc See breaking capacity curves (Contact configuration type A) See value for 50.000 operations 250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(2) (1) (2)
<2000 m
Other voltage upon request Ask for higher altitudes
Auxiliary relays | Railway sector
19
TRIP AND LOCKOUT RELAYS (II) Model
Applications
BF-4RP
BJ-8RP
Intended for tripping and locking applications where high quality requirements in operating time and breaking capacity are needed, with manual reset.
Construction characteristics Contacts no.
4 Changeover
Connections
Set + B1 + 1
2
Reset
10 14 9 13 8 12 7 11
Options Weight (g) Dimensions (mm)
8 Changeover
11 10 21 20 31 30 41 40 51 50 61 60 71 70 81 80
6 Set + a b + c d Reset
5 4 3
1 2 3 4 5 6 7 8
Options are not available 300
600
45 x 45 x 96,5 (F short Type)
90 x 50 x 100,5 (J short Type)
Coil characteristics 24, 48, 72, 110, 125, 220 Vdc 63,5, 110, 127, 230 Vac (50-60 Hz)
Standard voltages(1) Voltage range Pick-up voltage (20ºC) Consumptions only in the change-over
+10% -20% UN See pick-up voltage / temperature curves for Latching relays 23 W
35,5 W
<10 ms (Vdc) <13 ms (Vac)
<10 ms (Vdc) <20 ms (Vac)
Operating time Pick-up time Contacts Contact material Distance between contacts Permanent current
AgNi 1,8 mm 10 A
Instantaneous current
80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity Max. breaking capacity Umax opened contact
See breaking capacity curves (Contact configuration type A) See value for 50,000 operations 250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(2) (1) (2)
<2000 m
Other voltage upon request Ask for higher altitudes
20
Auxiliary relays | Railway sector
LATCHING RELAYS WITH COIL OVERVOLTAGE PROTECTION Model
BF-3BB
Applications
BF-4BB
BJ-8BB
Intended to protect the contact of the equipment that feeds the coil in our relay.
Construction characteristics Contacts no.
3 Changeover
Set Connections 10 1 Reset
9 + 13 14 8 + 12 2 7 11
4 Changeover
Set
5 4 3
Reset
Options Weight (g) Dimensions (mm)
+ B1 + 1
2
10 14 9 13 8 12 7 11
8 Changeover
6 5 4 3
Set
+ a b + c d Reset
Options are not available
11 10 21 20 31 30 41 40 51 50 61 60 71 70 81 80
1 2 3 4 5 6 7 8
300
600
45 x 45 x 96,5 (F large Type)
90 x 50 x 100,5 (J large Type)
Coil characteristics Standard voltages(1)
24, 48, 72, 110, 125, 220 Vdc(3)
Voltage range Pick-up voltage Consumptions only in the change-over
+25% -30% UN See pick-up voltage / temperature curves for Latching relays ≤6 W
≤12 W
Operating time Pick-up time
<20 ms
Contacts Contact material Distance between contacts Permanent current
AgNi 1,8 mm 10 A
Instantaneous current
80 A during 200 ms / 200 A during 10 ms
Max. making capacity
40 A / 0,5 s / 110 Vdc
Breaking capacity Max. breaking capacity Umax opened contact
See breaking capacity curves (Contact configuration type A) See value for 50,000 operations 250 Vdc / 400 Vac
Performance data Mechanical endurance
107 operations
Operating temperature
-40ºC +70ºC
Storage temperature
-40ºC +70ºC
Max. operating humidity
93% / +40ºC
Operating altitude(2) (1) (2) (3)
<2000 m
Other voltage upon request Ask for higher altitudes Vac voltages upon request
Auxiliary relays | Railway sector
21
BREAKING CAPACITY
› With devices operating worldwide, also heavy industries like oil & gas sector trust in our relays.
22
Relés auxiliares | Aplicaciones ferroviarias
BREAKING CAPACITY The breaking capacity is a critical parameter on the design and the applications of the relays. Its mechanical life could be considerably reduced, depending on the value of the load (especially with heavy duty loads), the number of operations and the environmental conditions in which the relay is operating. In any configuration, ARTECHE’s auxiliary relays have a high breaking capacity values. These limits are showed in the table below, in terms of power and current values. In all the cases, these relays guarantee a right performance during 50,000 operations. Likewise, the values showed in the following charts have been obtained in standard conditions in the laboratory, and they could be different in real conditions. In any case, the possibility of connecting serial contacts or a bigger distance between contacts makes these values to be considerably increased.
24 Vdc voltage Different loads configurations.
Resistive load:
›
L/R= 0 ms.
107
107
106
106
No. operations
No. operations
›
Highly inductive load:
105
L/R= 40 ms.
105
104
104 0
5
10
15 Current
20
25
0
2
4
Type A Type B
0 ms
Vdc
6
Contact configuration
8
10
12
Current
20 ms
40 ms
P(W)
I(A)
P(W)
I(A)
P(W)
I(A)
500
20,83
370
15,42
250
10,42
450
18,75
300
12,50
210
8,75
Type A 24 Type B
Auxiliary relays | Railway sector
23
110 Vdc voltage Different loads configurations.
Resistive load:
›
Highly inductive load:
›
L/R= 0 ms. 107
106
No. operations
No. operations
107
106
105
105
104 0,00
L/R= 40 ms.
104 0,20
0,40
0,60
0,80
1,00
1,20
1,40
1,60
1,80
2,00
0,00
0,10
0,20
0,30
0,50
0,40
Current
0,60
0,70
0,80
0,90
Current
Type A Tiype B
0 ms
Vdc
Contacts configuration
20 ms
40 ms
P(W)
I(A)
P(W)
I(A)
P(W)
I(A)
170
1,55
140
1,27
90
0,82
125
1,14
100
0,91
65
0,59
Type A 110 Type B
24
Auxiliary relays | Railway sector
1,00
220 Vdc voltage Different loads configurations.
Resistive load:
›
L/R= 0 ms.
107
107
106
106
No. operations
No. operations
›
Highly inductive load:
105
105
104 0,00
L/R= 40 ms.
0,10
0,20
0,30
0,40
0,50
0,60
0,70
0,80
104 0,00
0,05
0,10
0,15
Current
0,20
0,25
0,30
0,35
0,40
Current
Type A Type B
0 ms
Vdc
Contacts configuration
20 ms
40 ms
P(W)
I(A)
P(W)
I(A)
P(W)
I(A)
150
0,68
115
0,52
66
0,30
125
0,57
104
0,47
60
0,27
Type A 220 Type B
Auxiliary relays | Railway sector
25
HOW TO SELECT THE CURVE OF MY RELAY These charts show the breaking capacity values, either for resistive and highly inductive loads, in three voltage values of reference (ask for other voltage values). The charts show two different curves:
›
Type A: Breaking capacity of the relays with distance between contacts = 1.8 mm.
›
Type B: Breaking capacity of the relays with distance between contacts = 1.2 mm.
The distance between contacts is shown in the tables of technical data.
HOW THE BREAKING CAPACITY CAN BE INCREASED ARTECHE’s auxiliary relays are power relays, designed specially to have a high breaking capacity. Thus, there are applications where the loads are so high that it is necessary to even increase the breaking capacity, keeping the reliability of the contacts of the auxiliary relays. Thus, ARTECHE relays have the following alternatives and recommendations:
›
Possibility of external connection of equipment (serial contacts) getting an important increase of breaking capacity in these equipment is shown, guaranteeing the right performance during a high number of operations.
›
Include the magnetic blow-out option: This option is indicated for safety applications (back-up) where the load values are extremely high. The mechanical life of the relay is reduced, but it is able to open very high loads for a certain number of operations.
These values of high breaking capacity are represented in the following table, where the high capacity of the output contacts of ARTECHE’s auxiliary relays is proved:
Relay
I
V
L/R
5A
125 Vdc
40 ms
With contact configuration Type A + magnetic blow out (OP: 1XXXX) With contact configuration Type B + magnetic blow out (OP: 1XXXX)
26
Auxiliary relays | Railway sector
Arteche has more than 100 customer service technical points, an expert engineers network close to you everywhere
PICK-UP VOLTAGE/RELEASE VOLTAGE-TEMPERATURE CHARTS
28
Auxiliary relays | Railway sector
INSTANTANEUS RELAYS Variability of operative voltage range against temperature for the instantaneous auxiliary relays.
GENERAL PURPOSE RELAYS AND RELAYS WITH COIL OVERVOLTAGE PROTECTION Operative range against ambient temperature 200
Upper limit of the pick-up voltage
U/UN (%)
150
Pick-up voltage limit 100
Drop-out voltage limit Operative range of the coil voltage
50
0 -40 -30 -20 -10
0
10
20
30
40
50
60
70
80
90 100
110 120 130
Temperature (ºC)
TRIPPING RELAYS Operative range against ambient temperature
200
Upper limit of the pick-up voltage 150
U/UN (%)
Pick-up voltage limit Drop-out voltage limit
100
Operative range of the coil voltage 50
0 -40
-30
-20
-10
0
10
20
30
40
50
60
70
80
Temperature (ºC)
INSTANTANEOUS RELAYS WITH SEISMIC CHARACTERISTICS Operative range against ambient temperature
250
200
Upper limit of the pick-up voltage
U/UN (%)
150
Pick-up voltage limit Drop-out voltage limit
100
Operative range of the coil voltage 50
0 -40 -30 -20 -10
0
10
20
30
40
50
60
70
80
90
100 110 120 130
Temperature (ºC) Auxiliary relays | Railway sector
29
LATCHING RELAYS Variability of operative voltage range against temperature for the Latching relays.
LATCHING PURPOSE RELAYS AND RELAYS WITH COIL OVERVOLTAGE PROTECTION Operative range against ambient temperature
250
U/UN (%)
200
Upper limit of the pick-up voltage Pick-up voltage limit
150
Operative range of the coil voltage 100
50
0 -40 -30 -20
-10
0
10
20
30
40
50
60
70
80
90
100
110 120 130
Temperature (ºC)
TRIP AND LOCKOUT RELAY Operative range against ambient temperature
200
160
Upper limit of the pick-up voltage U/UN (%)
120
Pick-up voltage limit Operative range of the coil voltage
80
40
0 -40 -30 -20
-10
0
10
20
30
40
50
60
70
80
90
100
110 120 130
Temperature (ºC)
30
Auxiliary relays | Railway sector
TRIP AND LOCKOUT RELAY WITH RESET PUSH BUTTON Operative range against ambient temperature
200
160
U/UN (%)
Upper limit of the pick-up voltage 120
Pick-up voltage limit 80
Operative range of the coil voltage
40
0 -40 -30 -20
-10
0
10
20
30
40
50
60
70
80
90
100
110 120 130
Temperature (ºC)
TIME-LAG RELAYS Variability of operative voltage range against temperature for the time-lag relays.
RELÉS TEMPORIZADOS Operative range against ambient temperature
200
Upper limit of the pick-up voltage
U/UN (%)
150
Pick-up voltage limit 100
Drop-out voltage limit 50
Operative range of the coil voltage
0 -40
-30
-20
-10
0
10
20
30
40
50
60
70
80
Temperature (ºC)
Auxiliary relays | Railway sector
31
MODELS SELECTION Type
Instantaneous
Range
Range FF(*)
Aux. Supply Vdc or Vac.
Options
OP General purpose range 2 contacts relay
RD-2
4 contacts relay
RF-4
1
8 contacts relay
RJ-8
1
Tripping relays range Fast
R
1
Extra-fast (Vdc only)
XR
1 Restrictions
Seismic characteristics range Seismic
SY
With coil overvoltage protection range Diode in parallel with the coil (only Vdc)
DI
Varistance in parallel with the coil
V
With seismic characteristics and coil overvoltage protection range Seismic with diode in parallel with the coil (only Vdc)
SYDI
Seismic with diode in parallel with the coil
SYV
Range No
-
Yes
FF
Aux. Supply Vdc o Vac Indicate voltage level and if it is VDC or VAC (ex: 24 VDC) Options High breaking capacity (magnetic arc blow-out)
No
0
Yes
1
No
0
Front LED
Yes
1
Mechanical contact position indicator
No
0
Yes
1
Trip flag
Push to test button
No
0
Yes
1
No
0
To push the contacts
1
Fix the contacts
2
(*) Indicate just if FF range is required
32
Auxiliary relays | Railway sector
Type
Latching
Range
Range FF(**)
Aux. Supply Vdc or Vac.
General purpose range 3 contacts relay
BF-3
4 contacts relay
BF-4
8 contacts relay
BJ-8
Options Diode in parallel with the coil (only Vdc)
BB
Trip relay (only Vdc)
R
Fast-acting with reset push button (*)
RP
Range FF No
-
Yes
FF
Aux. Supply Vdc o Vac Indicate voltage level and if it is VDC or VAC (ex: 24 VDC) (*) Unavailable for 3 contacts
(**) Indicate just if FF range is required
Type
Timers
Range FF(**)
Aux. Supply Vdc or Vac.
Options OP
General purpose range Relay with 2 timer contacts TDF-2 Restrictions
Relay with 4 timer contact TDF-4 Relay with 2 instantaneous contacts + 2 timer contacts
TDF-22
Relay with 8 timer contacts TDJ-8 Relay with 4 instantaneous contacts + 4 timer contacts
TDJ-44
Range FF No
-
Yes
FF
Aux. Supply Vdc o Vac Indicate voltage level and if it is VDC or VAC (ex: 24 VDC) Options High Breaking Capacity (magnetic arc blow-out)
No
0
Yes
1
Dependent
0 24 Vdc • Vac
Command sign voltage
Independent
1
48 Vdc • Vac
2
60 Vdc • Vac
3
72 Vdc • Vac
4
96 Vdc • Vac
5
110 Vdc • Vac
6
125 Vdc • Vac
7
220 Vdc • Vac
8
(*) Indicate just if FF range is required
Auxiliary relays | Railway sector
33
DIMENSIONS OF THE RELAYS Type D
Type F
Type J
F Short
J Short
42,5
82,5
72
10,5
50,4
72
10,5
72
10,5
50,4
50,4
22,5
Relay dimensions
F Long
J Long
42,5
*100,5 96,6
10,5
96,6
10,5
50,4
50,4
82,5
*depending on the model
SOCKETS: DIMENSIONS AND CUT-OUT Accessories
Sockets Relay
D
F
J
34
Accessories
Type
Screw
Double faston
Weight (g)
TIP10 Front connection
DN-DE IP10 FF
DN-DE2C IP10 FF
60
IP20 Front connection
DN-DE IP20 FF DN-DE2C IP20 FF
60
Rear connection
DN-TR OP FF
DN-TR2C OP FF
Retaining clips
50
Function signs on the extraction ring Security pins (*)
IP10 Front connection
FN-DE IP10 FF
FN-DE2C IP10 FF
110
IP20 Front connection
FN-DE IP20 FF
FN-DE2C IP20 FF
110
IP20 Rear connection
FN-TR OP FF
FN-TR2C OP FF
IP20 Flush mounting
F-EMP OP FF
90
(*) Not availble for latching relays
300
IP10 Front connection
JN-DE IP10 FF
JN-DE2C IP10 FF
225
IP20 Front connection
JN-DE IP20 FF
JN-DE2C IP20 FF
225
IP20 Rear connection
JN-TR OP FF
JN-TR2C OP FF
IP20 Flush mounting
J-EMP OP FF
180 400
Auxiliary relays | Railway sector
Relays type D
Relays type F
ġŏ āĀŏŏđŏġĂŏ āĀŏ
Relays type J
4<237>444<23 17>44
Ăą Ăă
8<237>448<23 17>44
ąą ąă
Front connection for double
ĉą ĉă
faston IP10 sockets 105
ćą
105
ćą
105
ćą
DN-DE2C IP10 FN-DE2C IP10 JN-DE2C IP10 ĂĊ ĂĊ ăĂČă
ġŏ ĂĀŏŏđŏġĂŏ ĂĀŏ
(1) ĨĂĩ
ąĂČĈ ăĊČĉ
8<237> 448<23 17> 44
31 ĂĊ
ĉĂČĈ ĈĊČĉ
āāĂ
āāĂ
ăĂČă
ĉĉ
4<237> 444<23 17> 44
31 ĂĊ
ĂĂČĈ āĊČĉ
ăĂČă
ąĉ
31 ĂĊ
āāĂ
Ăĉ
Sockets for DIN rail
ĂĊ
lateral connection for the rest of the sockets
ĉą ĉĀ ąāČĉ
ąĂ
6
ąĀČĆ +- ĀČĂ
ĉĀČĆ +- ĀČĂ ąĂ
=
ąĂ
ąĂ
=
=
ąă ąāČĉ
6
Ăā =
ąă
ĆāČĂ
6 ĆāČĂ
Sockets for rear connection
ąą ąĀ
ĆāČĂ
ąă
Ăą ĂĀ
JN-B@=>448<-B@ 1=>44
FN-B@=>444<-B@ 1=>44
DN-ŏŏŏđŏ-Ăŏŏ
F3;>=>44F-EMP (short) OP FF
83;>=>4483;>(short) OP FF
ĉĀ
ĉĀ
āĂĀ
ĈĆ
āĀāČĆŏ
āĀāČĆŏ 15 āĂČĆ
ĉ
Sockets for flush mounting
15 āĂČĆ
ĉ
F3;>=>44F-EMP (long) OP FF
83;>=>4483;>(long) OP FF ĉĀ
ĉĀ
ĈĆ
āĂĀ
āĂą āĂą
15 āĂČĆ
ĉ
15 āĂČĆ
ĉ
ąČĆ
āĂĆ
ĊĀŏ)%*
66 ĆĈ
10ġ+10
Ă
Cut-out
66 ĆĈ
10ġ+10
āĂĆ
(1)
DIN rail according to EN50022
Auxiliary relays | Railway sector
(2)
ąČĆ
ĊĀŏ)%*
106 Ċć
ĉĀŏ)%*
DIN46277/3
ąČĆ
10ġ+10
ĊĀŏ)%*
61 50
66 ĆĈ
106 Ċć
Minimum distance between sockets will depend on type of relay and
sockets. Please request sockets user manual for more detailed information.
35
MOVING TOGETHER
Updates: ARTECHE_CT_Auxiliary-Relays-Railway Sector_E Version: A1
www.arteche.com
©Arteche