Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

FA 12-100B 12V100Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Communication Equipment · Medical Equipment · Emergency Power System · Telecom · Control Equipment · UPS General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 3mm (0.12inch) 16mm (0.63inch) M8mm (0.31inch) Construction Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 229mm(9.02inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 508mm(20.0inch) 110mm(4.33inch) Battery Model FA12-100B Designed Floating Life 12 Years Capacity(20oC) Dimensions 20HR(5.30A,1.80V) 10HR(10.0A,1.80V) 5HR(17.1A,1.75V) 106Ah 100Ah 85.5Ah Length Width Height Total Height 508mm(20.0inch) 110mm(4.33inch) 229mm(9.02inch) 229mm(9.02inch) 62.7Ah Approx. Weight 31.5Kg (69.5 lbs) Internal Resistance Full charged at 20oC: 0.0052 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(62.7A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use 14.1-14.4V(-30mV/ oC), max. Current: 25A Page 1 of 2 Float use 13.5-13.7V(-18mV/ oC) FA 12-100B 12V100Ah Charge Voltage (CA) (V/Cell) (%) 120 100 0.25 Constant Charge at 0.25CA-2.35V (20oC) Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 3 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.00 60 Min Time(hour) 2.08 0.6CA 85 80 75 70 65 60 55 50 1.92 1.83 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V 5 m in 35 0 31 5 29 9 26 6 24 0 18 2 10 m in 240 219 211 195 181 149 1 5 m in 1 75 1 70 1 64 1 55 1 48 1 28 3 0m in 10 5 10 2 10 0 9 8 .0 9 5 .0 8 7 .4 1h 6 2.7 6 2.6 6 2.4 6 1.8 6 1.0 6 0.3 3h 27 .5 27 .3 27 .2 27 .0 26 .9 26 .8 5h 1 7 .5 1 7 .3 1 7 .2 1 7 .1 1 6 .9 1 6 .8 10h 1 0.6 1 0.5 1 0.4 1 0.2 1 0.0 9 .83 2 0h 5.5 3 5.5 1 5.5 0 5.4 9 5.3 0 4.9 8 1h 124 119 116 115 113 112 3h 52 .4 52 .4 52 .0 51 .6 50 .9 50 .7 5h 3 3 .6 3 3 .4 3 3 .2 3 2 .9 3 2 .3 3 1 .9 10h 2 1.2 2 0.9 2 0.7 2 0.4 2 0.0 1 9.7 2 0h 11 .5 11 .3 11 .2 11 .0 10 .7 10 .0 Constant power discharge ratings-watts at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V 5 m in 57 7 54 7 51 1 47 6 42 7 34 2 10 m in 398 393 383 358 333 276 1 5 m in 3 10 3 07 3 02 2 84 2 67 2 33 3 0m in 19 8 19 4 18 9 18 4 17 9 16 4 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)