Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Simplify Your Storage On the Web | www.sun.com/storage Sun StorEdge™ 6120 Array and Sun StorEdge™ 6320 System Modular storage solutions that optimize asset utilization and simplify data management. Simple to deploy Today’s business-critical challenges are tougher than ever. You’re under pressure to reduce Storage policies simplify provisioning and management complexity and cost, increase utilization, and improve responsiveness and agility. make it easy to tune capacity and perform- The Sun StorEdge™ 6000 Family helps you meet these challenges by combining open, modular ance to meet specific application workloads. flexibility and simplified management with robust availability to deliver exceptional business value. The easy-to-deploy Sun StorEdge 6000 Family features comprehensive system and data Easy to manage management from a central console, and the standards-based, CIM-compliant software ensures Systems and arrays are easily managed seamless interoperability with leading storage management tools. And the same software is from a single console and share common used to manage both systems and arrays, which means you don’t have to learn new software management software, reducing com- or add storage resources as you scale to meet changing business needs. plexity and overhead, and enabling users The Sun StorEdge 6000 Family’s storage policies simplify provisioning with pre-configured to manage more storage with fewer profiles that are tailored to meet specific application capacity and performance requirements resources, simplifying administration. while increasing predictability. The Sun StorEdge 6000 Family also includes Solaris-based data protection software that combines robust point-in-time and remote replication functionality for Robust data protection increased data availability. Plus, you can migrate data easily across all members of the family, Solaris-based point-in-time copy, remote ensuring data-in-place investment protection. And the systems and arrays come with software mirroring, and system-wide visibility that provides enhanced data protection and a SAN-wide utility that enables consolidated man- enhance manageability, reduce down- ageability of your Sun Open SAN. So you can get the most out of your storage resources, protect time and ensure data availability. your investment, and reduce overall TCO. Simplify Your Storage with Sun StorEdge solutions. Fully interoperable Standards and arrays support a wide range of heterogeneous computing environments and are CIM-compliant, eliminating the complexity of matching platform to storage, and providing maximum utilization, simplified management, and reduced TCO. Sun StorEdge 6120 Array Sun StorEdge 6320 System Sun StorEdge™ 6120 Array and Sun StorEdge™ 6320 System On the Web sun.com/storage Sun StorEdge™ 6120 Array Sun StorEdge™ 6320 System Sun StorEdge™ 6120 and 6320 Specifications Business is dynamic, and so are your storage Designed to help meet the challenges of SOFTWARE needs. You need flexible solutions that enable your most dynamic multi-application deploy- Operating System Support you to respond quickly to change. The Sun ments, the Sun StorEdge 6320 system delivers StorEdge 6120 array provides a complete the market-focused flexibility, availability, storage offering that combines a modular and performance of an advanced modular storage platform with robust data services architecture with integrated system-wide to make it ideal for economical application manageability. The massively scalable, easy- Solaris™ 8 Operating System, update 4 or later Solaris 9 Operating System, base or later Microsoft Windows NT Server 4.0 SP6 Microsoft Windows 2000—Advanced Server SP3 HP-UX 11.0 and 11.i IBM AIX 4.3.3 (32-bit support) and 5.1 (32- and 64-bit support) RedHat Linux 7.0 deployments. The array scales from 250 GB to-deploy system grows right along with Management Software Support to over 12 TB to meet application needs, is your business, scaling incrementally from designed for maximum redundancy, and 500 GB to 45 TB to meet your changing needs, comes with single or dual controllers and and its balanced approach to storage ensures advanced array fail-over technology. The that capacity and performance scale seam- Sun StorEdge Configuration Service software (included) Storage Automated Diagnostic Environment (included) Sun StorEdge Traffic Manager for Solaris (included) Sun StorEdge SAN Foundation Kit (included) Sun StorEdge Enterprise Storage Manager v1.2 (included) Sun StorEdge Availability suite 3.1 (included) arrays are available with drive bays partially lessly to meet application requirements. or totally populated, and can be easily up- The Sun StorEdge 6320 system is easily man- graded into an integrated storage system, aged from a single console, and it provides making them ideal for business-critical high levels of data availability through maxi- applications. And thanks to new, standards- mum redundancy, proactive fault detection, based, open management software and automatic call-home, and remote diagnostics. storage policies, you can quickly and easily Which helps you reduce overhead, increase tune the arrays to meet your needs. utilization, and reduce management cost Simple to deploy and complexity. Software Support Sun StorEdge Performance suite (QFS 4.0 or later) Sun StorEdge Utilization Suite Software (SAM-FS 4.0 or later) Sun StorEdge Traffic Manager software Sun StorEdge Resource Manager software suite Sun Cluster™ 3.0 or later Sun StorEdge Enterprise Backup 7.0 Software VERITAS Volume Manager with DMP (VxVM) 3.5 or later VERITAS NetBackup (NBU) 3.4, or later VERITAS File System (VxFS) 3.5, or later VERITAS Cluster Server 1.3, or later Sun PatchPro on Solaris Sun Remote Services (SRS)—Net Connect 3.0 SM Provides reliable, predictable midrange Highly available storage for economical application develop- Integrated, proactive monitoring and sup- HARDWARE ment. Open, modular approach ensures a port infrastructure ensures data availability Supported Platforms seamless upgrade path into an integrated in the most challenging business environ- storage system. ments. Fully redundant, modular design Flexible Can be quickly and easily configured to with no single point of failure is ideal for scaling while maintaining data uptime. meet application-specific workloads, and Massively scalable performance can grow into a complete storage system and capacity featuring integrated SAN, advanced man- Multiple RAID controllers and 500 GB to agement software, and remote monitoring 45 TB expandability enable the system to and diagnostics. scale performance and capacity in parallel Cost-effective Low cost to midrange value ($/MB) and Sun Fire™ 3800, 4800, 4810, 6800, 12K, and 15K servers Sun Fire V100, V120, V210, V240, 280R, V880, and V1280 servers Sun Enterprise™ 3x00, 4x00, 6x00, and E10K servers Sun Enterprise 220R, 250, 420R, and 450 servers Netra™ 1120, 1125, 1200, 1400, and 1405 servers Supported Host Adapters Solaris Windows environment to meet the dynamic demands of today’s most challenging business applications. comprehensive, common management Protects your investment software enable cost-effective overall use Data-in-place investment protection lets of storage resources. you move data easily and safely across all members of the Sun StorEdge 6000 Family. HP environment IBM environment Linux environment SAN Sun StorEdge 1 Gb and 2 Gb PCI Dual Fibre Channel network adapters Sun StorEdge SBUS Dual Fibre Channel network adapters Sun StorEdge cPCI Dual Fibre Channel network adapters Emulex L8000-Fi/Ni,* Emulex LP9XXX 2-Gb Fibre Channel PCI* Qlogic* QLA2200F/66,* QLA23XX 2-Gb Fibre Channel PCI* HP A5158A,* 6795A* IBM FC 6227, IBM FC 6228* Qlogic* QLA2200F/66,* QLA23XX 2-Gb Fibre Channel PCI* Sun SAN 4.2 or greater *All non-Sun host bus adapters supported by third-party vendor. Fibre Channel Configuration Options Fibre Channel arbitrated public and private loop Point-to-point or Switched fabric Drives Form factor Supported drives 3.5-in. drives (7 to 14 per enclosure for 6120) 36 GB, 15,000 rpm; 73 GB, 10,000 rpm; 146 GB, 10,000 rpm Sun StorEdge™ 6120 Array Purchase this product from the SM Sun Store, sun.com/store, or contact an authorized Sun reseller near you. Specifications Standard Interfaces Drives Controller card Power Unit interconnect cards Power connector Power cables Dual-ported FC-SCA-2 LC-SFF Fibre Channel connector RJ45 10/100 Base-T network connector RJ45 RS-232 connector HSSDC2-X2 CEE 22-V (latching, U.S. only) Two NEMA 5-15P Input power Input current AC power Maximum Capacities (RAW) 36 GB / 15K 73 GB / 10K 146 GB / 10K Single controller configurations Dual controller, HA configurations 1.5 TB 3.0 TB 3.1 TB 6.1 TB 6.1 TB 12.3 TB Environment Controller Card One RAID controller card per enclosure RAID levels 0, 1(1+0), 5 1-GB data cache per controller with ECC protection options Up to 64 Volumes per unit with Volume masking/slicing 5 bock sizes: 4K, 8K, 16K, 32K, 64K (user configurable) Configurable hot spare Single 2-Gb host Fibre Channel interface Hardware pipelined XOR Host Ports Single controller configurations Dual controller, HA configurations One 2-Gbit/s Fibre Channel port Two 2-Gbit/s Fibre Channel port Power and Cooling Power/cooling units Two redundant power/cooling units per enclosure Integrated backup battery power for cache destage Redundant fans with temperature sensors Unit Interconnect Unit interconnect cards Two redundant unit interconnect cards per enclosure FC-AL circuitry Storage Network Interconnect Operating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z) Noise 5°C to 40°C, maximum gradient 20°C per hour 10% to 90%, noncondensing –1000 to 10,000 ft. (–305 to 3048 m) 4.0 g for maximum duration of 11 ms (half sinewave) 5 to 500 Hz at 0.25 g LWAd = 7.6 bels* Nonoperating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z) –40°C to 65°C, maximum gradient 20°C per hour 93%, noncondensing –1000 to 40,000 ft. (–305 to 12,192 m) 10.0 g for maximum duration of 11 ms (half sinewave) 5 to 500 Hz at 1.0 g *LWAd (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C Dimensions and Weight Height Width Depth Weight 5.25 in. (13.3 cm)3U / 10.5 in. (26.6 cm)6U 17.5 in. (44.5 cm) 18.9 in. (48.0 cm) 90 lb. (41 kg) / 180 lb. (82 kg) Warranty/Service Warranty Installation service Service upgrades Sun two-year warranty with Same Business Day,* on-site parts delivery, four business Hours* on-site hardware service response, local extended business hours coverage, 24x7 phone support Sun StorEdge Array System Installation service (optional) SunSpectrum service upgrades are available SM *Average response times Regulations Native LC-SFF Fibre-Channel connection Maximum multimode optical fiber length of 500 meters Field Replaceable Units (Hot-swappable) Drives Controller card Power/cooling units Unit interconnect cards 500 W maximum 5.0 A maximum 100 to 240 V AC at 47 to 63 Hz single phase Front Rear Rear Rear Meets or exceeds the following requirements: RFI/EMI EN55022, FCC 47CFR Part 15 Class A, EN61000-3-2, EN61000-3-3 EN55024, EN300 386 V.1.3.1 (09-2001) Safety UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950 TUV CB Scheme with all national differences Regulatory markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS Ergonomics EK1-ITB-2000 For additional information on this product, go to www.sun.com/storage/midrange/6000/6100/6120 Sun StorEdge™ 6320 System Purchase this product from the SM Sun Store, sun.com/store, or contact an authorized Sun reseller near you. Specifications Standard Interfaces Drives Service panel Environment Power connector (U.S.) Power connector (International) Power cables Dual-ported FC-SCA-2 RJ45 and industry-standard USB connectors LC-SFF and MPO optical connectors NEMA L6-30P for 200 to 240 V AC (two per cabinet) 32 A, single phase IEC 309 connected to 200 to 240 V AC (two per cabinet) Two NEMA 5-15P Maximum Capacities (RAW) 36 GB / 15K 73 GB / 10K 146 GB / 10K Base cabinet Base cabinet + expansion cabinet 5.0 TB 11.1 TB 10.2 TB 22.5 TB 20.4 TB 45.0 TB Maximum Host Connections* Integrated Switches (dual 16-port, 2Gb) *Two connections per host Direct Connect (w/o integrated switches) Host connect 5 – 15 1 – 11 2-Gbit/s F port (Fabric port) Maximum Logical Device Support Base Cabinet Base Cabinet + Expansion Cabinet 320 Volumes 704 Volumes Required Clearances Front Rear Front Rear 48 in. (122 cm) 36 in. (92 cm) Field Replaceable Units FRU access at front FRU access at rear Operating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z) 5°C to 35°C (41°F to 95°F) 10% to 90%, noncondensing –1000 to 10,000 ft. (–305 to 3048 m) 3.0 g for maximum duration of 11 ms (half sinewave) 0.15 g on z-axis; 0.10 g on x- and y-axes; 5 to 500 Hz sinusoidal Nonoperating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z) –40°C to 60°C (–40°F to –76°F) 93%, noncondensing –1000 to 40,000 ft. (–305 to 12,192 m) 1.0 inch roll-off freefall, front to back rolling directions 0.5 g on z-axis; 0.25 g on x- and y-axes; 5 to 500 Hz sinusoidal Regulations Meets or exceeds the following requirements: RFI/EMI EN55022, EN55024, FCC CFR47, Part 15 Class A, EN61000-3-2, EN61000-3-3 Safety UL 1950, 3rd Ed., EN 60950:1992, 2nd Ed.+A1+A2+A3+A4+A11 CSA-C22.2 No. 950, IEC 60950:1991, 2nd Ed.+A1+A2+A3+A4+A11 TUV CB Scheme with all national differences Regulatory markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS Ergonomics EK1-ITB-2000 Dimensions and Weight Disk drives Storage Service Processor Midplane/chassis enclosure Controller and loop cards Power/cooling units Fibre Channel switches (optional) Storage Service Processor accessory tray Ethernet hub Height Width Depth Weight Footprint Heat output Input power (per cabinet) AC power 4200W (maximum) Two dedicated 200 to 220 V AC, 30 A circuit breakers 200 to 240 V AC at 47 to 63 Hz single phase Base Cabinet + Expansion Cabinet Warranty/Service Warranty Power Base Cabinet 75.0 in. (190.5 cm) 75.0 in. (190.5 cm) 23.9 in. (60.7 cm) 47.8 in. (121.4 cm) 37.0 in. (94 cm) 37.0 in. (94.0 cm) 1700 lb. (771 kg) 3600 lb. (1633 kg) 6.14 sq. ft. (0.5706 sq. m) 12.29 sq. ft. (1.411 sq. m) ~ 15,000 BTU ~ 28,000 BTU Installation service Service upgrades Sun two-year warranty with Same Business Day,* on-site parts delivery, four business Hours* on-site hardware service response, local extended business hours coverage, 24x7 phone support Sun StorEdge Array System Installation service (optional) SunSpectrum service upgrades are available SM *Average response times For additional information on this product, go to www.sun.com/storage/midrange/6000/6300/6320 Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-800-555-9SUN or 1-650-960-1300 Web sun.com/storage Sun Worldwide Sales Offices: ARGENTINA:+5411-4317-5600; AUSTRALIA:+61-2-9844-5000; AUSTRIA:+43-1-60563-0; BELGIUM:+32-2-704-8000; BRAZIL:+55-11-5187-2100; CANADA:+905-477-6745; CHILE:+56-2-3724500; COLOMBIA:+571-629-2323; COMMONWEALTH OF INDEPENDENT STATES:+7-502-935-8411 CZECH REPUBLIC:+420-2-3300-9311; DENMARK:+45 4556 5000; EGYPT:+202-570-9442; ESTONIA:+372-6-308-900; FINLAND:+358-9-525-561; FRANCE:+33-134-03-00-00; GERMANY:+49-89-46008-0; GREECE:+30-1-618-8111; HUNGARY:+36-1-489-8900; ICELAND:+354-563-3010 INDIA : BANGALORE : +91-80-2298989/2295454; NEW DELHI : +91-11-6106000; MUMBAI : +91-22-697-8111; IRELAND : +353-1-8055-666; ISRAEL : +972-9-9710500; ITALY: +39-02-641511; JAPAN : +81-3-5717-5000; KAZAKHSTAN :+7-3272-466774; KOREA :+822-2193-5114 LATVIA:+371-750-3700; LITHUANIA:+370-729-8468; LUXEMBOURG:+352-49 11 33 1; MALAYSIA:+603-21161888; MEXICO:+52-5-258-6100; THE NETHERLANDS:+00-31-33-45-15-000; NEW ZEALAND: AUCKLAND:+64-9-976-6800; WELLINGTON:+64-4-462-0780; NORWAY:+47 23 36 96 00 PEOPLE’S REPUBLIC OF CHINA: BEIJING: +86-10-6803-5588; CHENGDU: +86-28-619-9333; GUANGZHOU: +86-20-8755-5900; SHANGHAI: +86-21-6466-1228; HONG KONG: +852-2202-6688; POLAND: +48-22-8747800; PORTUGAL: +351-21-4134000; RUSSIA: +7-502-935-8411 SAUDI ARABIA : +9661 273 4567; SINGAPORE : +65-6438-1888; SLOVAK REPUBLIC : +421-2-4342-94-85; SOUTH AFRICA : +27 11 256-6300; SPAIN : +34-91-596-9900; SWEDEN : +46-8-631-10-00; SWITZERLAND : GERMAN : 41-1-908-90-00; FRENCH : 41-22-999-0444 TAIWAN:+886-2-8732-9933; THAILAND:+662-344-6888; TURKEY:+90-212-335-22-00; UNITED ARAB EMIRATES:+9714-3366333; UNITED KINGDOM:+44-1-276-20444; UNITED STATES:+1-800-555-9SUN OR +1-650-960-1300; VENEZUELA:+58-2-905-3800; OR ONLINE AT SUN . COM /STORE SUN™ Specifications subject to change without notice. ©2003 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, the Sun logo, Sun StorEdge, Netra, Solaris, Sun Cluster, Sun Enterprise, Sun Fire, Sun Remote Services Net Connect, and SunSpectrum are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. LFC1.8 Printed in USA 4/03 DE1812-0/10K