Transcript
Simplify Your Storage
On the Web | www.sun.com/storage
Sun StorEdge™ 6120 Array and Sun StorEdge™ 6320 System Modular storage solutions that optimize asset utilization and simplify data management.
Simple to deploy
Today’s business-critical challenges are tougher than ever. You’re under pressure to reduce
Storage policies simplify provisioning and
management complexity and cost, increase utilization, and improve responsiveness and agility.
make it easy to tune capacity and perform-
The Sun StorEdge™ 6000 Family helps you meet these challenges by combining open, modular
ance to meet specific application workloads.
flexibility and simplified management with robust availability to deliver exceptional business value. The easy-to-deploy Sun StorEdge 6000 Family features comprehensive system and data
Easy to manage
management from a central console, and the standards-based, CIM-compliant software ensures
Systems and arrays are easily managed
seamless interoperability with leading storage management tools. And the same software is
from a single console and share common
used to manage both systems and arrays, which means you don’t have to learn new software
management software, reducing com-
or add storage resources as you scale to meet changing business needs.
plexity and overhead, and enabling users
The Sun StorEdge 6000 Family’s storage policies simplify provisioning with pre-configured
to manage more storage with fewer
profiles that are tailored to meet specific application capacity and performance requirements
resources, simplifying administration.
while increasing predictability. The Sun StorEdge 6000 Family also includes Solaris-based data protection software that combines robust point-in-time and remote replication functionality for
Robust data protection
increased data availability. Plus, you can migrate data easily across all members of the family,
Solaris-based point-in-time copy, remote
ensuring data-in-place investment protection. And the systems and arrays come with software
mirroring, and system-wide visibility
that provides enhanced data protection and a SAN-wide utility that enables consolidated man-
enhance manageability, reduce down-
ageability of your Sun Open SAN. So you can get the most out of your storage resources, protect
time and ensure data availability.
your investment, and reduce overall TCO. Simplify Your Storage with Sun StorEdge solutions.
Fully interoperable Standards and arrays support a wide range of heterogeneous computing environments and are CIM-compliant, eliminating the complexity of matching platform to storage, and providing maximum utilization, simplified management, and reduced TCO.
Sun StorEdge 6120 Array
Sun StorEdge 6320 System
Sun StorEdge™ 6120 Array and Sun StorEdge™ 6320 System
On the Web sun.com/storage
Sun StorEdge™ 6120 Array
Sun StorEdge™ 6320 System
Sun StorEdge™ 6120 and 6320 Specifications
Business is dynamic, and so are your storage
Designed to help meet the challenges of
SOFTWARE
needs. You need flexible solutions that enable
your most dynamic multi-application deploy-
Operating System Support
you to respond quickly to change. The Sun
ments, the Sun StorEdge 6320 system delivers
StorEdge 6120 array provides a complete
the market-focused flexibility, availability,
storage offering that combines a modular
and performance of an advanced modular
storage platform with robust data services
architecture with integrated system-wide
to make it ideal for economical application
manageability. The massively scalable, easy-
Solaris™ 8 Operating System, update 4 or later Solaris 9 Operating System, base or later Microsoft Windows NT Server 4.0 SP6 Microsoft Windows 2000—Advanced Server SP3 HP-UX 11.0 and 11.i IBM AIX 4.3.3 (32-bit support) and 5.1 (32- and 64-bit support) RedHat Linux 7.0
deployments. The array scales from 250 GB
to-deploy system grows right along with
Management Software Support
to over 12 TB to meet application needs, is
your business, scaling incrementally from
designed for maximum redundancy, and
500 GB to 45 TB to meet your changing needs,
comes with single or dual controllers and
and its balanced approach to storage ensures
advanced array fail-over technology. The
that capacity and performance scale seam-
Sun StorEdge Configuration Service software (included) Storage Automated Diagnostic Environment (included) Sun StorEdge Traffic Manager for Solaris (included) Sun StorEdge SAN Foundation Kit (included) Sun StorEdge Enterprise Storage Manager v1.2 (included) Sun StorEdge Availability suite 3.1 (included)
arrays are available with drive bays partially
lessly to meet application requirements.
or totally populated, and can be easily up-
The Sun StorEdge 6320 system is easily man-
graded into an integrated storage system,
aged from a single console, and it provides
making them ideal for business-critical
high levels of data availability through maxi-
applications. And thanks to new, standards-
mum redundancy, proactive fault detection,
based, open management software and
automatic call-home, and remote diagnostics.
storage policies, you can quickly and easily
Which helps you reduce overhead, increase
tune the arrays to meet your needs.
utilization, and reduce management cost
Simple to deploy
and complexity.
Software Support Sun StorEdge Performance suite (QFS 4.0 or later) Sun StorEdge Utilization Suite Software (SAM-FS 4.0 or later) Sun StorEdge Traffic Manager software Sun StorEdge Resource Manager software suite Sun Cluster™ 3.0 or later Sun StorEdge Enterprise Backup 7.0 Software VERITAS Volume Manager with DMP (VxVM) 3.5 or later VERITAS NetBackup (NBU) 3.4, or later VERITAS File System (VxFS) 3.5, or later VERITAS Cluster Server 1.3, or later Sun PatchPro on Solaris Sun Remote Services (SRS)—Net Connect 3.0 SM
Provides reliable, predictable midrange
Highly available
storage for economical application develop-
Integrated, proactive monitoring and sup-
HARDWARE
ment. Open, modular approach ensures a
port infrastructure ensures data availability
Supported Platforms
seamless upgrade path into an integrated
in the most challenging business environ-
storage system.
ments. Fully redundant, modular design
Flexible Can be quickly and easily configured to
with no single point of failure is ideal for scaling while maintaining data uptime.
meet application-specific workloads, and
Massively scalable performance
can grow into a complete storage system
and capacity
featuring integrated SAN, advanced man-
Multiple RAID controllers and 500 GB to
agement software, and remote monitoring
45 TB expandability enable the system to
and diagnostics.
scale performance and capacity in parallel
Cost-effective Low cost to midrange value ($/MB) and
Sun Fire™ 3800, 4800, 4810, 6800, 12K, and 15K servers Sun Fire V100, V120, V210, V240, 280R, V880, and V1280 servers Sun Enterprise™ 3x00, 4x00, 6x00, and E10K servers Sun Enterprise 220R, 250, 420R, and 450 servers Netra™ 1120, 1125, 1200, 1400, and 1405 servers
Supported Host Adapters Solaris
Windows environment
to meet the dynamic demands of today’s most challenging business applications.
comprehensive, common management
Protects your investment
software enable cost-effective overall use
Data-in-place investment protection lets
of storage resources.
you move data easily and safely across all members of the Sun StorEdge 6000 Family.
HP environment IBM environment Linux environment SAN
Sun StorEdge 1 Gb and 2 Gb PCI Dual Fibre Channel network adapters Sun StorEdge SBUS Dual Fibre Channel network adapters Sun StorEdge cPCI Dual Fibre Channel network adapters Emulex L8000-Fi/Ni,* Emulex LP9XXX 2-Gb Fibre Channel PCI* Qlogic* QLA2200F/66,* QLA23XX 2-Gb Fibre Channel PCI* HP A5158A,* 6795A* IBM FC 6227, IBM FC 6228* Qlogic* QLA2200F/66,* QLA23XX 2-Gb Fibre Channel PCI* Sun SAN 4.2 or greater
*All non-Sun host bus adapters supported by third-party vendor.
Fibre Channel Configuration Options Fibre Channel arbitrated public and private loop Point-to-point or Switched fabric
Drives Form factor Supported drives
3.5-in. drives (7 to 14 per enclosure for 6120) 36 GB, 15,000 rpm; 73 GB, 10,000 rpm; 146 GB, 10,000 rpm
Sun StorEdge™ 6120 Array
Purchase this product from the SM
Sun Store, sun.com/store, or contact an authorized Sun reseller near you.
Specifications Standard Interfaces Drives Controller card
Power
Unit interconnect cards Power connector Power cables
Dual-ported FC-SCA-2 LC-SFF Fibre Channel connector RJ45 10/100 Base-T network connector RJ45 RS-232 connector HSSDC2-X2 CEE 22-V (latching, U.S. only) Two NEMA 5-15P
Input power Input current AC power
Maximum Capacities (RAW)
36 GB / 15K
73 GB / 10K
146 GB / 10K
Single controller configurations Dual controller, HA configurations
1.5 TB 3.0 TB
3.1 TB 6.1 TB
6.1 TB 12.3 TB
Environment
Controller Card One RAID controller card per enclosure RAID levels 0, 1(1+0), 5 1-GB data cache per controller with ECC protection options Up to 64 Volumes per unit with Volume masking/slicing 5 bock sizes: 4K, 8K, 16K, 32K, 64K (user configurable) Configurable hot spare Single 2-Gb host Fibre Channel interface Hardware pipelined XOR
Host Ports Single controller configurations Dual controller, HA configurations
One 2-Gbit/s Fibre Channel port Two 2-Gbit/s Fibre Channel port
Power and Cooling Power/cooling units
Two redundant power/cooling units per enclosure Integrated backup battery power for cache destage Redundant fans with temperature sensors
Unit Interconnect Unit interconnect cards
Two redundant unit interconnect cards per enclosure FC-AL circuitry
Storage Network Interconnect
Operating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z) Noise
5°C to 40°C, maximum gradient 20°C per hour 10% to 90%, noncondensing –1000 to 10,000 ft. (–305 to 3048 m) 4.0 g for maximum duration of 11 ms (half sinewave) 5 to 500 Hz at 0.25 g LWAd = 7.6 bels*
Nonoperating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z)
–40°C to 65°C, maximum gradient 20°C per hour 93%, noncondensing –1000 to 40,000 ft. (–305 to 12,192 m) 10.0 g for maximum duration of 11 ms (half sinewave) 5 to 500 Hz at 1.0 g
*LWAd (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C
Dimensions and Weight Height Width Depth Weight
5.25 in. (13.3 cm)3U / 10.5 in. (26.6 cm)6U 17.5 in. (44.5 cm) 18.9 in. (48.0 cm) 90 lb. (41 kg) / 180 lb. (82 kg)
Warranty/Service Warranty
Installation service Service upgrades
Sun two-year warranty with Same Business Day,* on-site parts delivery, four business Hours* on-site hardware service response, local extended business hours coverage, 24x7 phone support Sun StorEdge Array System Installation service (optional) SunSpectrum service upgrades are available SM
*Average response times
Regulations Native LC-SFF Fibre-Channel connection Maximum multimode optical fiber length of 500 meters
Field Replaceable Units (Hot-swappable) Drives Controller card Power/cooling units Unit interconnect cards
500 W maximum 5.0 A maximum 100 to 240 V AC at 47 to 63 Hz single phase
Front Rear Rear Rear
Meets or exceeds the following requirements: RFI/EMI EN55022, FCC 47CFR Part 15 Class A, EN61000-3-2, EN61000-3-3 EN55024, EN300 386 V.1.3.1 (09-2001) Safety UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950 TUV CB Scheme with all national differences Regulatory markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS Ergonomics EK1-ITB-2000
For additional information on this product, go to www.sun.com/storage/midrange/6000/6100/6120
Sun StorEdge™ 6320 System
Purchase this product from the SM
Sun Store, sun.com/store, or contact an authorized Sun reseller near you.
Specifications Standard Interfaces Drives Service panel
Environment
Power connector (U.S.) Power connector (International) Power cables
Dual-ported FC-SCA-2 RJ45 and industry-standard USB connectors LC-SFF and MPO optical connectors NEMA L6-30P for 200 to 240 V AC (two per cabinet) 32 A, single phase IEC 309 connected to 200 to 240 V AC (two per cabinet) Two NEMA 5-15P
Maximum Capacities (RAW)
36 GB / 15K
73 GB / 10K
146 GB / 10K
Base cabinet Base cabinet + expansion cabinet
5.0 TB 11.1 TB
10.2 TB 22.5 TB
20.4 TB 45.0 TB
Maximum Host Connections*
Integrated Switches (dual 16-port, 2Gb)
*Two connections per host
Direct Connect (w/o integrated switches)
Host connect
5 – 15 1 – 11 2-Gbit/s F port (Fabric port)
Maximum Logical Device Support
Base Cabinet
Base Cabinet + Expansion Cabinet
320 Volumes
704 Volumes
Required Clearances
Front
Rear
Front Rear
48 in. (122 cm) 36 in. (92 cm)
Field Replaceable Units FRU access at front
FRU access at rear
Operating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z)
5°C to 35°C (41°F to 95°F) 10% to 90%, noncondensing –1000 to 10,000 ft. (–305 to 3048 m) 3.0 g for maximum duration of 11 ms (half sinewave) 0.15 g on z-axis; 0.10 g on x- and y-axes; 5 to 500 Hz sinusoidal
Nonoperating Temperature Relative humidity Effective altitude Shock (from any axis X, Y, Z) Vibration (from any axis X, Y, Z)
–40°C to 60°C (–40°F to –76°F) 93%, noncondensing –1000 to 40,000 ft. (–305 to 12,192 m) 1.0 inch roll-off freefall, front to back rolling directions 0.5 g on z-axis; 0.25 g on x- and y-axes; 5 to 500 Hz sinusoidal
Regulations Meets or exceeds the following requirements: RFI/EMI EN55022, EN55024, FCC CFR47, Part 15 Class A, EN61000-3-2, EN61000-3-3 Safety UL 1950, 3rd Ed., EN 60950:1992, 2nd Ed.+A1+A2+A3+A4+A11 CSA-C22.2 No. 950, IEC 60950:1991, 2nd Ed.+A1+A2+A3+A4+A11 TUV CB Scheme with all national differences Regulatory markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS Ergonomics EK1-ITB-2000
Dimensions and Weight Disk drives Storage Service Processor Midplane/chassis enclosure Controller and loop cards Power/cooling units Fibre Channel switches (optional) Storage Service Processor accessory tray Ethernet hub
Height Width Depth Weight Footprint Heat output
Input power (per cabinet) AC power
4200W (maximum) Two dedicated 200 to 220 V AC, 30 A circuit breakers 200 to 240 V AC at 47 to 63 Hz single phase
Base Cabinet + Expansion Cabinet
Warranty/Service Warranty
Power
Base Cabinet
75.0 in. (190.5 cm) 75.0 in. (190.5 cm) 23.9 in. (60.7 cm) 47.8 in. (121.4 cm) 37.0 in. (94 cm) 37.0 in. (94.0 cm) 1700 lb. (771 kg) 3600 lb. (1633 kg) 6.14 sq. ft. (0.5706 sq. m) 12.29 sq. ft. (1.411 sq. m) ~ 15,000 BTU ~ 28,000 BTU
Installation service Service upgrades
Sun two-year warranty with Same Business Day,* on-site parts delivery, four business Hours* on-site hardware service response, local extended business hours coverage, 24x7 phone support Sun StorEdge Array System Installation service (optional) SunSpectrum service upgrades are available SM
*Average response times
For additional information on this product, go to www.sun.com/storage/midrange/6000/6300/6320
Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-800-555-9SUN or 1-650-960-1300 Web sun.com/storage
Sun Worldwide Sales Offices: ARGENTINA:+5411-4317-5600; AUSTRALIA:+61-2-9844-5000; AUSTRIA:+43-1-60563-0; BELGIUM:+32-2-704-8000; BRAZIL:+55-11-5187-2100; CANADA:+905-477-6745; CHILE:+56-2-3724500; COLOMBIA:+571-629-2323; COMMONWEALTH OF INDEPENDENT STATES:+7-502-935-8411 CZECH REPUBLIC:+420-2-3300-9311; DENMARK:+45 4556 5000; EGYPT:+202-570-9442; ESTONIA:+372-6-308-900; FINLAND:+358-9-525-561; FRANCE:+33-134-03-00-00; GERMANY:+49-89-46008-0; GREECE:+30-1-618-8111; HUNGARY:+36-1-489-8900; ICELAND:+354-563-3010 INDIA : BANGALORE : +91-80-2298989/2295454; NEW DELHI : +91-11-6106000; MUMBAI : +91-22-697-8111; IRELAND : +353-1-8055-666; ISRAEL : +972-9-9710500; ITALY: +39-02-641511; JAPAN : +81-3-5717-5000; KAZAKHSTAN :+7-3272-466774; KOREA :+822-2193-5114 LATVIA:+371-750-3700; LITHUANIA:+370-729-8468; LUXEMBOURG:+352-49 11 33 1; MALAYSIA:+603-21161888; MEXICO:+52-5-258-6100; THE NETHERLANDS:+00-31-33-45-15-000; NEW ZEALAND: AUCKLAND:+64-9-976-6800; WELLINGTON:+64-4-462-0780; NORWAY:+47 23 36 96 00 PEOPLE’S REPUBLIC OF CHINA: BEIJING: +86-10-6803-5588; CHENGDU: +86-28-619-9333; GUANGZHOU: +86-20-8755-5900; SHANGHAI: +86-21-6466-1228; HONG KONG: +852-2202-6688; POLAND: +48-22-8747800; PORTUGAL: +351-21-4134000; RUSSIA: +7-502-935-8411 SAUDI ARABIA : +9661 273 4567; SINGAPORE : +65-6438-1888; SLOVAK REPUBLIC : +421-2-4342-94-85; SOUTH AFRICA : +27 11 256-6300; SPAIN : +34-91-596-9900; SWEDEN : +46-8-631-10-00; SWITZERLAND : GERMAN : 41-1-908-90-00; FRENCH : 41-22-999-0444 TAIWAN:+886-2-8732-9933; THAILAND:+662-344-6888; TURKEY:+90-212-335-22-00; UNITED ARAB EMIRATES:+9714-3366333; UNITED KINGDOM:+44-1-276-20444; UNITED STATES:+1-800-555-9SUN OR +1-650-960-1300; VENEZUELA:+58-2-905-3800; OR ONLINE AT SUN . COM /STORE
SUN™
Specifications subject to change without notice. ©2003 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, the Sun logo, Sun StorEdge, Netra, Solaris, Sun Cluster, Sun Enterprise, Sun Fire, Sun Remote Services Net Connect, and SunSpectrum are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. LFC1.8 Printed in USA 4/03 DE1812-0/10K