Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

2215-2216 Max. 35 W Programmable chargers for NiMH/NiCd batteries 2216 - utskiftbare/exchangeable AC plugs • Universal input voltage • Medically certified (EN 60601) • UL approved (2601-1) • CPM-Computer Programmable Microprocessor offering: - Charge detection options (one or more): -dV , dT/dt , 0 dV , Timer - Safety timer , dV threshold, and temp. gradient adjustment • Universal inngangsspenning • Medisinsk sertifisert (EN 60601) • UL godkjent (2601-1) • CPM-Computer Programmerbar Microprosessor tilbyr: - Ladedeteksjonsvalg (en eller fler): -dV, dT/dt , 0 dV , Timer - Justering av sikkerhetstimer, dV nivå og temp. stigningsnivå MEDICAL IP67 2216 Tekniske data Technical specifications Inngangsspenning Input voltage Maks. utgangseffekt Max. Output power Vedlikeholdsladestrøm Trickle charge current Strømtrekk fra batt v. frakoblet nett Leakage current f. battery w mains off Start timer (ingen -dV deteksjon) ** Start timer (no -dV detection) ** Top-off timer ** Top-off timer ** Sikkerhetstimer ** Safety timer ** Svitsjefrekvens Switch frequency Temperaturområde Temperature range Virkningsgrad (ved 100% last) Efficiency (at 100% load) Sikring Protection * Inngang * Input * Utgang * Output Isolasjonsklasse Insulation class Elektrisk sikkerhet Electrical safety EMC standarder EMC standards * Medisinsk * Medical * Emisjon * Emission * Immunitet * Immunity Nettilkopling Mains connection IP grad IP code Mål (LxBxH) Dimensions (LxWxH) Vekt Weight ** Annet ** Other 90-264 VAC, 50-60Hz 35W 100mA +/-50mA 10-20 cell: 50mA +/-25mA < 1mA 3 min. 1 time/hour 2 timer/hours 40 kHz -20 - +40 °C ca 78 % Sikringsmotstand/fusible resistor Polyswitch-sikring mot polvending/ Polyswitch fuse against reversed polarity II EN 60601-1, EN 60950, EN 60335-2-29, UL 2601-1 EN 60601-1-2 EN 61000-6-3 EN 61000-6-1 2 pins IEC 320 41 107 x 67 x 36,5mm 250g Laderen er programmerbar – se data The charger is programmable – see spec for Mascot CPMM * Nettledning følger ikke med. Må bestilles i tillegg. Mains cable not included. Order separately. Versjoner – versions Celler Cells 3-6 4-8 5-10 6-12 10-20 Tomgangs- spenning Min utsp. for -dV deteksjon Max utsp. for -dV deteksjon -dV deteksjon mV/celle eller % Hurtig ladestrøm Topplading (1t. e. -dV detek.) No-load voltage Min. out. for -dV detection Max out. for -dV detection -dV detection mV/cell or % Fast charge current Top-off charge (1h. a. -dV det.) 3,0A +/- 250mA 2,2A +/- 150mA 1,8A +/- 150mA 1,5A +/- 100mA 0,9A +/- 70mA 390mA +/- 80mA 310mA +/- 80mA 270mA +/- 70mA 240mA +/- 60mA 130mA +/- 40mA 12,8V +/-0,7V 16,5V +/-1V 21V +/-1,2V 24,7V +/-1,5V 41V +/-2V Note: 3,7V 5,0V 6,2V 7,5V 12,5V (min. 3 c.) (min. 4 c.) (min. 5 c.) (min. 6 c.) (min. 10 c.) min 1,25 V pr. cell 10,8V (max 6 c.) 11mV/0,6% 14,4V (max 8 c.) 18V (max 10 c.) 21,6V (max 12 c.) 8mV/0,5% 36V (max 20 c.) max 1,8 V pr. cell 28122007 Programmerbare ladere for NiMH/NiCd b e NiMH batteries Oppladbare NiMH batterier Ladekurve og lysdiode (LED) indikasjon ved -dV deteksjon Charging diagram and LED indication for -dV detection ming more advanced and their uses are spreading ety of ccordds on argers or safe harge, must dle a attery Mascot velopduces ntellim 16W t the e flexe bat- er i dag både svært populære og avanserte, og d til m lige Dette krav skal k mang batter tidig ding, sikker sett d og i en ny ligent som i både og sik Stand models hurtig using ladeko ut the ladern ipped en Com Charging diagram and LED indication for -dV detection r Promerba oprocsor (C hey can readily be programmed to fit a variety of kan raskt omprogrammeres til andre ladekontroll ese charge detections include (one or more options ladefunksjonene er (en eller flere parametere komb tments can be made to: radient ually well suited for charging NiCd batteries. Other ude: automatic polyswitch fuse against reversed ut. Compliance with international standards for 60601). Custom and waterproof units (IP 67) are est. • • • • -dV dT/dt 0 dV Kun timer I tillegg kan følgende parametere justeres: • sikkerhetstimer • -dV nivå • temperaturgradient Samtlige modeller er også velegnet for lading av Laderne har automatisk polyswitch-sikring mot 28122007 utgang, og er godkjente for medisinsk bruk i hht E tilpasninger og vanntette (IP67) enheter leveres på