AWUF Wall-Mount Air Handler 1½ to 3 Tons Standard Features • Suitable for use with refrigerants R-410A and R-22 • Equipped with a Check Flowrater for cooling-only and heat pump operation • Direct-drive, multi-speed motor allows air volume variation for heating/cooling • Sequence-controlled, rust-resistant nickel chromium heating elements of 3, 5, 8, and 10 kW • Factory-installed pull-type disconnect • Aluminum tubing coils on all models • AHRI Certified • ETL Listed Cabinet Features • Thermoplastic drain pan with bottom primary and secondary drain connections • Built-in filter rack (filter included) • Large chassis (2½- and 3-ton units) – front return only • Small chassis (1½- and 2-ton units) – front or bottom return • Wall-hanging bracket provided Accessories • Wall access doors: — WAD-1 fits AWUF18 and AWUF24 — WAD-2 fits AWUF30 through AWUF37 * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 10Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-AAWUF www.amana-hac.com Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. 3/12 Supersedes 1/11 Product Specifications Nomenclature A 1 W 2 Brand A Single-piece Air Handler Unit Application C Ceiling Mount PSC Motor D Downflow PSC Motor E Multi-Position Variable-Speed Motor R Multi-Position PSC Motor S Multi-Position EEM Motor W Wall Mount PSC Motor Cabinet Finish U Unpainted P Painted N Uncased Expansion Device F Flowrater T Expansion Valve 2 U 3 F 4 3610 5,6,7,8 1 9 6 10 AA 11,12 Engineering * Major/ Minor Revisions * Not used for inventory management Refrigerant Compatability No Digit = R-22 only 6 = R-410A or R-22 Electrical 1 208/240 V, 1 Phase, 60 Hz Nominal Capacity Range @ 13 SEER Multi-Position & Downflow Applications 1729 1½ to 2½ Tons (for Export Systems) 1830 1½-3½ Tons 3642 3-3½ Tons Ceiling-Mount & Wall-Mount Applications (Nominal Cooling Capacity/ Electric Heat kW) 1805 1½ Tons Cooling/ 5 kW Electric Heat 2405 2 Tons Cooling/ 5 kW Electric Heat 3610 3 Tons Cooling/ 10 kW Electric Heat www.amana-hac.com SS-AAWUF 3, 5 Electric Heat (kW) 6 ¾” Width Coil Drain Connection FPT 17.3 20 20 197 253 Min Circuit Ampacity (208V) Max. Overcurrent Protection (240V) Max. Overcurrent Protection (208V) Minimum VAC Maximum VAC 1.30 1/5 84 FLA HP Ship Weight (lbs) Blower Motor 15.1 Min Circuit Ampacity (240V) Voltage 240/208 ⅝” Suction Electrical Data ⅜” Liquid Service Valve 9 Diameter Blower 18,000 Cooling (BTU/h) Nominal Ratings AWUF 180316B 84 1/5 1.35 253 197 30 30 23.3 26.7 240/208 ⅝” ⅜” ¾” 6 9 5 18,000 AWUF 18051/16A 84 1/5 1.3 253 197 25 30 23.3 26.6 240/208 ⅝” ⅜” ¾” 6 9 5 18,000 AWUF 18051/16B 84 1/5 1.35 253 197 40 40 34.6 39.7 240/208 ⅝” ⅜” ¾” 6 9 8 18,000 AWUF 18081/16A 84 1/5 1.3 253 197 35 40 34.6 39.6 240/208 ⅝” ⅜” ¾” 6 9 8 18,000 AWUF 18081/16B 84 1/5 1.30 253 197 20 20 17.3 15.1 240/208 ⅝” ⅜” ¾” 6 10 3, 5 24,000 AWUF 240316B 84 1/5 1.35 253 197 30 30 23.3 26.7 240/208 ⅝” ⅜” ¾” 6 10 5 24,000 AWUF 24051/16A 84 1/5 1.3 253 197 25 30 23.3 26.6 240/208 ⅝” ⅜” ¾” 6 10 5 24,000 AWUF 24051/16B 84 1/5 1.35 253 197 40 40 34.2 39.7 240/208 ⅝” ⅜” ¾” 6 10 8 24,000 AWUF 24081/16A Product Specifications Specifications SS-AAWUF www.amana-hac.com 3 8 Electric Heat (kW) 6 ¾” Width Coil Drain Connection FPT 4 34.6 40 35 197 253 Min Circuit Ampacity (208V) Max. Overcurrent Protection (240V) Max. Overcurrent Protection (208V) Minimum VAC Maximum VAC 1.3 1/5 84 FLA HP Ship Weight (lbs) Blower Motor 39.6 Min Circuit Ampacity (240V) Voltage 240/208 ⅝” Suction Electrical Data ⅜” Liquid Service Valve 10 Diameter Blower 24,000 Cooling (BTU/h) Nominal Ratings AWUF 24081/16B 84 1/5 1.35 253 197 50 60 45.6 52.7 240/208 ⅝” ⅜” ¾” 6 10 10 24,000 AWUF 24101/16A 84 1/5 1.3 253 197 50 60 45.9 52.7 240/208 ⅝” ⅜” ¾” 6 10 10 24,000 AWUF 24101/16B 93 ⅓ 1.58 253 197 20 20 17.6 15.5 240/208 ¾” ⅜” ¾” 8 9 3, 5 30,000 AWUF 300316B 93 ⅓ 1.58 253 197 25 30 23.6 27 240/208 ¾” ⅜” ¾” 8 9 5 30,000 AWUF 30051/16B 93 ⅓ 1.58 253 197 35 40 34.9 40 240/208 ¾” ⅜” ¾” 8 9 8 30,000 AWUF 30081/16B 93 ⅓ 1.58 253 197 50 60 46.2 53 240/208 ¾” ⅜” ¾” 8 9 10 30,000 AWUF 30101/16B 96 1/2 4.1 253 197 30 35 26.8 30.1 240/208 ¾” ⅜” ¾” 8 10 5 18,000-30,000 AWUF 310516A* Product Specifications Specifications (cont.) www.amana-hac.com SS-AAWUF 8 Electric Heat (kW) 8 ¾” Width Coil Drain Connection FPT 38.1 45 40 197 253 Min Circuit Ampacity (208V) Max. Overcurrent Protection (240V) Max. Overcurrent Protection (208V) Minimum VAC Maximum VAC 4.1 1/2 96 FLA HP Ship Weight (lbs) Blower Motor 43.1 Min Circuit Ampacity (240V) Voltage 240/208 ¾” Suction Electrical Data ⅜” Liquid Service Valve 10 Diameter Blower 18,000-30,000 Cooling (BTU/h) Nominal Ratings AWUF 310816A* 96 1/2 4.1 253 197 50 60 49.4 56.2 240/208 ¾” ⅜” ¾” 8 10 10 18,000-30,000 AWUF 321016A* 96 ⅓ 1.58 253 197 25 30 23.6 27 240/208 ¾” ⅜” ¾” 8 9 5 36,000 AWUF 36051/16B 96 ⅓ 1.58 253 197 35 40 34.9 40 240/208 ¾” ⅜” ¾” 8 9 8 36,000 AWUF 36081/16B 96 ⅓ 1.58 253 197 50 60 46.2 53 240/208 ¾” ⅜” ¾” 8 9 10 36,000 AWUF 36101/16B 96 1/2 4.1 253 197 30 35 26.8 30.1 240/208 ¾” ⅜” ¾” 8 10 5 36,000 AWUF 370516B 96 1/2 4.1 253 197 40 45 38.1 43.1 240/208 ¾” ⅜” ¾” 8 10 8 36,000 AWUF 370816B 96 1/2 4.1 253 197 50 60 49.4 56.2 240/208 ¾” ⅜” ¾” 8 10 10 36,000 AWUF 371016B Product Specifications Specifications (cont.) SS-AAWUF www.amana-hac.com 5 Product Specifications Airlfow Data Motor Speed Model AWUF18XX1/16A* AWUF18XX16B* AWUF24XX1/16A* AWUF24XX16B* AWUF30XX1/16A* AWUF30XX16B* AWUF310516XX AWUF310816XX AWUF321016XX AWUF36XX1/16A* AWUF36XX16B* AWUF37XX16A* AWUF37XX16B* CFM Delivered Against External Static Pressure 0.1” 0.2” 0.3” 0.4” 0.5” High 750 730 690 650 595 Low 710 700 690 635 585 High 755 715 670 615 545 Low 740 700 655 595 535 High 880 845 810 770 735 Low 845 815 780 745 705 High 900 870 835 795 760 Low 865 835 800 765 725 High 1250 1195 1135 1085 1010 Low 1110 1055 1020 955 905 High 1255 1120 1100 1020 950 Low 1115 1010 990 900 820 T5 875 865 830 805 765 T4 1005 975 945 920 890 T3 840 795 785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 T5 1090 1065 1040 1015 985 T4 1005 975 945 920 890 T3 840 795 785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 High 1280 1190 1110 1010 930 Low 1170 1100 1030 950 890 High 1215 1145 1070 985 890 Low 1120 1065 1000 915 820 High 1325 1285 1230 1180 1115 Low 1085 1060 1030 995 950 T5 1385 1205 1130 1045 950 T4 1235 1180 1115 1040 955 T3 1165 1120 1075 1025 945 T2 1050 1010 970 930 860 T1 1050 1010 970 930 860 Heating Capacity Correction Factor* Supply Voltage 240 230 220 210 208 Correction Factor 1.00 .92 .84 .76 .74 * Multiply 240-volt capacity by correction factor 6 www.amana-hac.com SS-AAWUF Product Specifications Dimensions LOW V OLT P OWE R S UP P LY ( L A R G E C H AS S I S O N L Y ) S UC TION LINE OFFS E T HANG ING B R AC K E T LIQUID LINE P U L L O U T DI S C O N N E C T R E M O V AB L E S E R V I C E DO O R L OW V OLT P OWE R S UP P LY E L E C T R I C AL P OWE R S UP P LY F R O N T AC C E S S P AN E L S M AL L C H AS S I S S T U D AT T A C H M E N T HOLE S FR ONT R E TUR N FILTE R L AR G E C H AS S I S B O T T O M P R I M AR Y AN D S E C O N DAR Y DR AI N S C AN B E AC C E S S E D T H R O U G H T H E B O T T O M O F T H E U N I T . ( 3 /4 " N P T F E M AL E C ONNE C TION) N O T E : H AN D T I G H T E N O N L Y Small Chassis (AWUF18/24) Large Chassis (AWUF30-37) A 36” A 36” B 3 20 /16” B 24” C 16⅛” C 21” D 16” D 19⅞” E 11” E 15⅞” Filter 14” x 18” x 1” Filter (30/36) 16” x 20” x 1” Filter (31/32/37) 18” x 20” x 1” SS-AAWUF www.amana-hac.com 7 Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Product Specifications AWUF18/24/30/36 Wiring Diagram 8 www.amana-hac.com SS-AAWUF Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Product Specifications AWUF31/32 Wiring Diagram SS-AAWUF www.amana-hac.com 9 Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Product Specifications AWUF37 Wiring Diagram 10 www.amana-hac.com SS-AAWUF Product Specifications Notes SS-AAWUF www.amana-hac.com 11 Product Specifications Notes Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2010 • Goodman Company, L.P. • Houston, Texas • Printed in the USA. 12 www.amana-hac.com SS-AAWUF