Transcript
JQX-13F
JQX-13F
Coil Parameter AC
03001003500 28 21.5 35.5
3C:28 31.5 36
R50126378
4C:28 41.5 36
C
US
Ordering Information 1
a DC12V 1 L
2
3
4
5
6
1 Part number JQX-13F 2 Contact arrangement 1A:1A 2A:2A 3A:3A; 1B:1B 2B:2B 3B:3B 1C:1C 2C:2C 3C:3C 4A:4A 4B:4B 4C:4C 3 Terminal a:inserting type b:PCB type 4 Coil rated voltage(V) AC:6,12,24,36,48,110,120,220,240 DC:6,12,24,36,48,110,220
5 Cover 1:1Mode 2:2 Mode 6 Coil transient suppression L:with LED D:with diode; LD:with LED & diode NIL:standard
Contact Data Contact Material
AgCdO AgSnO2 1A(1H) (SPSTNO) 1B (1D)(SPSTNC) 1C(1Z) (SPDT(B-M))
Contact Arrangement
2A(2H) (DPSTNO) 2B(2D) (DPSTNC) 2C(2Z) (DPDT(B-M))
3A(3H)(SPSTNO) 3A(3H)(SPSTNO) 3B(3D)SPSTNC) 3B(3D)(SPSTNC) 3C(3Z)(3PDT(B-M)) 4C(4Z)(4PDT(B-M))
Resistive 15A, 20A/277VAC,28VDC 10A/277VAC,12A250VAC,28VDC 1/2 HP 125VAC Contact Rating Motor load 1/3 HP 120VAC 240VAC 1/3 HP 120VAC 240VAC 1/3HP 125VAC Coil DC 0.9W 0.9W 1.4W power AC 1.2VA 1.2VA 2VA Max. Switching Voltage 30VDC 300VAC Max. Switching Power 560W 5540VA Max. Switching Current:20A Max. Resistance or 50m Item 4.12 of IEC 61810-7 Voltage drop 105 Item 4.30 of IEC 61810-7 Operation al Electrical life Mechanical 2 107 I tem 4 .31 of IEC 61810-7
1.5W 2.5VA
Dash numbers
Rated
Max.
Pick up voltage V(max) 80%of rated voltage
Release voltage V(min) 10%of rated voltage
006-900 012-900 024-900 036-900 048-900 110-900 220-900
6 12 24 36 48 110 220
6.6 13.2 26.4 39.6 52.8 121 242
40 160 640/650 1440 2600 11000 53778
4.8 9.6 19.2 28.8 38.4 88.0 176
0.6 1.2 2.4 3.6 4.8 11.0 22.0
012-1400 024-1400 036-1400 048-1400 110-1400 220-1400
12 24 36 48 110 220
13.2 26.4 39.6 52.8 121 242
107 410 926 1700 8500 34571
9.6 19.2 28.8 38.4 88.0 176
1.2 2.4 3.6 4.8 11.0 22.0
012-1500 024-1500 036-1500 048-1500 110-1500 220-1500
12 24 36 48 110 220
13.2 26.4 39.6 52.8 121 242
100 350 865 1600 6900 32267
9.6 19.2 28.8 38.4 88.0 176
1.2 2.4 3.6 4.8 11.0 22.0
1.2
006AC-1200 012AC-1200 024AC-1200 036AC-1200 048AC-1200 110AC-1200 120AC-1200 220AC-1200 240AC-1200
6 12 24 36 48 110 120 220 240
6.6 13.2 26.4 39.6 52.8 121 132 242 312
11.5 46 184 320 735 3900 4550 14400 19000
183.0 91.0 46.0 33.0 24.0 11.0 9.8 5.5 4.2
4.8 9.6 19.2 28.8 38.4 88.0 96.0 176 192
1.8 3.6 7.2 10.8 14.4 33.0 36.0 66.0 72.0
012AC-2000 024AC-2000 036AC-2000 048AC-2000 110AC-2000 220AC-2000 240AC-2000
12 24 36 48 110 220 240
13.2 26.4 39.6 52.8 121 242 312
24 100 230 410 2300 8600 12100
167 83 56 42 18 9.1 6.2
9.6 19.2 28.8 38.4 88.0 176 192
3.6 7.2 10.8 14.4 33.0 66.0 72.0
012AC-2500 024AC-2500 036AC-2500 048AC-2500 110AC-2500 220AC-2500 240AC-2500
12 24 36 48 110 220 240
13.2 26.4 39.6 52.8 121 242 312
20 78 180 350 1600 6700 9120
208 104 69 52.1 22.7 11.4 9.8
9.6 19.2 28.8 38.4 88.0 176 192
3.6 7.2 10.8 14.4 33.0 66.0 72.0
Rated current mA
2.0
2.5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Coil Parameter DC Coil resistance 10%
Coil power VA
Max.
Insulation Resistance1)
Coil voltage V
Release voltage V(min) 30%of rated voltage
Rated
E169380
Small size, light weight, heavy reverse power. Optional mounting ways. Firm structure, strong anti-shock & anti vibration. Suitable for automatic control, telecommunication equipment, household electrical appliances and machinery electrical facilities.
Pick up voltage V(max) 80%of rated voltage
Coil resistance 10%
Dash numbers
Features
JQX-13F 2C
Coil voltage V
1000M
min (at 500VDC)
Item 7 of IEC 61810-5
1)
Coil power W
0.9
Operate Time ms
Release Time ms
25
25
Dielectric Strength Between contacts Between contact and coil
50Hz 1000V 50Hz 1500V
Shock resistance
100m/s2
Vibration resistance
10~55Hz double amplitude 1.5mm
IEC68-2-6 Test Fc
Terminals strength
8N 4N(PC type)
IEC68-2-21 Test Ua2
Solderability
235
Item 6 of IEC 61810-5 Item 6 of IEC 61810-5
11ms
2
3
IEC68-2-27 Test Ea
0.5s
Ambient Temperature
-40~70 ; -25~70 (3C,4C)
Relative Humidity
85% (at 30 )
Mass
37g(1C,2C);50g(3C);70g(4C)
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Note: 1). When testing, coil terminals should be connected , if LED is installed in relay . 1.4
25
25
Safety approvals Safety approval Load
1.5
25
25
UL&CUR 1A,1B,1C:20A/277VAC,28VDC 13 HP120VAC,240VAC 2A,2B,2C,3A,3B,3C,4A,4B,4C: 10A/277VAC,12A/250VAC,28VDC 1 2 HP 125VAC 2A,2B,2C: 1 3 HP120VAC,240VAC
T V 10A/277VAC,28VDC
CQC 10A/220VAC
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
73
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Electronics Corporation LTD.
74
JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3 Dimensions 2 2 8Max. 1.102max.
03001003501 06001015773 R
29 12.8 26
43 1.693 38 1.496 28max. 1.102max. 0.846max.
21.5max.
3.5
0.138
1.5(2) 0.059(0.079)
0.098
C
US
E174722
R50126370
Features
0.197
0.118
0.256
0.059
0.846max.
21.5max.
0.079
1.398max.
35.5max. 6.5
2 model
0.256
35.5max.
1.398max.
6.5
0.256
1 model
JQX-14FC1 & JQX-14FC2 (4124) JQX-14FC3
mm /inch
Heavy load, suitable for heavy power reverse. Small size, suitable for high-density mounting. Up to 5000VAC dielectric strength. Between open contacts of JQX-14FC3 3000VAC dielectric strength. Contact gap of JQX-14FC3 :2¡Á1.5mm=3mm. Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
0.197 0.197
Ordering Information
JQX-14FC1 C
PCB type
Inserting type
Leading end shape diagram
1
Dimensions
0.181
30
10
2C (+)
(+)
0.281
0.787
20 4.6
1C 7.15
14- 2.5 0.098
4.6 6
3C 4C
4C
Wiring diagram (Bottom view)
Mounting (Bottom view)
NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only.
Contact Rating (resistive)
Dash numbers
25
Release time
15
Coil Power W
75
Mechanical life AC type
Coil Power W
Contact current A
Contact current A
Operate time
25
Contact switching capacity
Life expectancy Mechanical life DC type
Operation
30
Coil temp. Rise
Temperature rise(deg)
Time(m sec )
35
0.8 3.5 6
7
5 Coil rated voltage(V)
DC:3,5,6,9,12,15,24 AC:6,12,24,48,110,120,220 6 Coil power cunsumption NIL:0.53W 0.8:0.8W 1:1VA 1.2:1.2W 7 Pole-distance 3.5:3.5mm 5:5.0mm
AC Resistive
1A SPSTNO 2A DPSTNO 1C SPDT(B-M) 2C DPDT(B-M) AgCdO AgSnO2 1A:16A/250VAC,30VDC; 1C:10A,16A,20A/250VAC,30VDC; 10A/14VDC(20A Application for 5mm Pole-distance) 2A,2C:5A,8A/220VAC, 30VDC;JQX-14FC3;2A:8A/220VAC;2C:6A/220VAC Motor load:1HP 250VAC ; 1/2HP 125VAC Lamp load:TV-5 600W 5000VA 110VDC 380VAC Max. Switching Current:20A 50m Item 4.12 of IEC 61810-7 5 10 Item 4.30 of IEC 61810-7 107 5 106 (JQX-14FC3) Item 4.31 of IEC 61810-7 2 1.5mm=3mm (JQX-14FC3)
DC
Coil voltage VDC Rated
Reference Data Operate time
5
1 Part number JQX-14FC1 JQX-14FC2 JQX-14FC3 2 Contact arrangement A:1A 2A:2A C:1C 2C:2C 3 Enclosure S: Sealed type Z: Dust cover 4 Contact current 3A,5A,6A,8A,10A,16A,20A
Coil Parameter
40
4
Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Electrical Operation life Mechanical Contact gap
6
0.181 0.236
3C
10 DC12V
3
Contact Arrangement Contact Material
1.181
7.15 0.281
(+)
S
Contact Data
6 0.236
2C
1C 11- 2.5 0.098
14.2
10
0.394
14.2
0.559
4.6
6 0.236
(+)
7.15 0.281
0.394
4.6
0.181
8- 2.5 0.098
0.559
7.15 0.281
0.394
10
5- 2.5 0.098
2
Coil resistance 10%
Max
C 1C 2
Release Pick up voltage voltage VDC(min) VDC(max) (75%of rated ( 10%of rated voltage ) voltage )
003-530
3
3.9
17
2.25
0.3
005-530
5
6.5
47
3.75
0.5
006-530
6
7.8
68
4.50
0.6
009-530
9
11.7
153
6.75
0.9
012-530
12
15.6
275
9.00
1.2
024-530 048-530
24 48
31.2 62.4
1100 4350
18.0 36.0
2.4 4.8
Coil power consumption W
Operate Time ms
Release Time ms
C 1C 2
C 1C 2
C 1C 2
0.53
15
10
DC Resistive
Contact voltage V
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Electronics Corporation LTD.
76