Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Batten microwave sensor datasheet V 1.2 Specifications Microwave, ambient light HF system 5.8 GHz CW radar, ISM band, <0.5 mW Supply voltage 230 V ~ Power consumption <0.5 W (stand by) Operating temperature -35 to 70°C Output load 800 W resistive 400 W inductive 200 W capacitive, led Information is subject to change without notice, E&OE Last updated 21 / 03 / 17 Sensors Detection motion speed 0.5 - 3 m/s Product range Order code Description zc-mw-batten Microwave sensor 12 m, batten kit, IP65 Ingress protection IP65 Material PC UV stabilised Features ■■ Switching capacity max. 800W ■■ Suitable for wall or ceiling mount Detection pattern ■■ Supplied with 700 mm cable ready to wire Mounting type Field of view Range ø Installation height ■■ Control based on ambient light and motion detection Wall 150° 16 x 6 m 1 - 1.8 m Ceiling 360° 12 x 12 m 2.5 - 6 m ■■ 5.8 GHz continuous wave radar, ISM band (industrial, scientific and medical) ■■ Motion can be detected through plastic, glass and thin non-metal materials ■■ Zero-crossing operation helps protect the sensor against high in-rush current 14 12 10 8 6 Dimensions 4 2 0 34 10% 2 4 25% 6 50% 8 100% 75% 75% 100% 10 12 50% 25% 14 6 4 10% 2 2 4 6 2 ø16 4 6 8 10 12 14 43.5 ø72 8.5 ø24 Wall Ceiling Wiring diagram L’ Red N Blue L Brown connected by installer L’in E L’in 105 [email protected] / zencontrol.com / L to driver N © zencontrol Batten microwave sensor datasheet V 1.2 Configuration Last updated 21 / 03 / 17 By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application. Remove top cover to access setting selection. Daylight The lamp works always, even during daylight Twilight The lamp works only in twilight and darkness Darkness The lamp works only in darkness Information is subject to change without notice, E&OE on off 1 2 3 Range Detection area Detection area can be reduced by selecting the combination on the DIP switches to fit precisely each application 100% (default) 75% 50% 25% 10% 4 5 6 Hold time 5 sec (default) Hold time Refers to the time period the lamp remains at 100% illumination after no motion detected 30 sec 90 sec 3 min 20 min 30 min 7 8 9 Lux operation Daylight sensor The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold 2 lx darkness operation only 10 lx darkness operation only 25 lx twilight operation 50 lx twilight operation Daylight sensor disabled (default) [email protected] / zencontrol.com / © zencontrol