Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Calculite® Incandescent Open Downlight Page 1 of 2 B7054 6” Aperture A19 / MB19 / A21 2 4 Top View B600 1 Top View REMODELER Remodel (B600RM) Frame-In FRAME-IN KIT Kit 9 5/8" A21 8 7/8" A19 MB19 5 3" 6 1" min. 2 1/8" max. (Ceiling Runner) 6" Dia. 3 6 1/2" Flush 7 8 1 1/8" max. Ceiling Thickness 7 1/4" Overlap Flush Trim (Molded trim ring removed) B600 Ceiling Cutout: 6 9/16" Dia., B600RM Ceiling Cutout: 6 1/2" Dia. Reflector Trims B7054CLW B7054CLP B7054CL B7054 9 Specular Clear finish with white flange Specular Clear finish with polished flange Specular Clear finish with molded trim ring (flangeless) Add suffix for other finishes (see options) Molded Trim Ring Overlap Self-Flange Matte White or Polished Frame-In Kit Lamp B600 A19, 100W max. MB19, 100W max. A21, 150W max. Remodel Frame-In Kit Lamp B600RM (for use in existing ceilings with 3/8” min. to 2” max. thickness) Same as B600 Features Options & Accessories 1. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Can be adjusted without tools from inside or outside of fixture to accommodate two different lamp sizes. Contains medium base porcelain socket with nickel plated screw shell wired and No. 18 SF-1 leads to J-Box. 2. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 1 1/2" lathing channel, or 1/2" (11/16" O.D.) EMT pipe, or optional mounting bars. 3. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 4. Reflector: 16 ga. Specular Alzak® aluminum, 45° visual cutoff to lamp and lamp image. Available with white or polished flange, or with removable white molded trim ring (field paintable). 5. Junction Box: 14 ga. Steel, 4" x 3 1/2" x 2" box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Mounting Frame: Die-cast aluminum suitable for dry or plaster. Provides flush trim in plaster ceiling. 8. Multi-Groove Baffle (B7054MG): One piece seamless Aluminum. Sharply detailed concentric rings with “sawtooth” profile, optical black finish. Permanently fastened to Specular Clear reflector. 9. Black Cone (B7054BK): Specular Black Alzak® aluminum. Permanently fastened to Specular Clear reflector. 18" Mounting Bars 27" Mounting Bars T-Bar Anchor Clips Existing Ceiling Clips Sloped Ceiling Adapters Step Down Transformer Chicago Air Plenum 1950 (set of 2) 1951 (set of 2) 1956 (set of 4, for 1950 & 1951 bars) 7998 (set of 2) 7920 (see SCA specification sheet) 7997 (see separate specification sheet) LC (add suffix to Frame-in Kit) Electrical B600 UL Listed for through branch circuit wiring with max. of (8) No. 12, 75°C supply conductors or 60°C conductors for end of run. B600RM UL Listed for No. 12 AWG 60°C supply conductors. Labels UL Listed (Suitable for damp locations), I.B.E.W. Alzak® is a registered trademark of ALCOA. Job Information Type: Job Name: Cat. No.: Lamp(s): Notes: Other Reflector Finish Options Comfort Clear Diffuse Specular Gold White CCD GD WH Specular Black BK Multi-Groove Baffle MG (MG available with molded trim ring only) Flange Options White Flangeless W Polished Flange Leave Blank (molded trim ring) P Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902 B7054 Calculite® Incandescent Open Downlight 6” Aperture A19 / MB19 / A21 B7054CL 60 150 Watt A-21 2770 Lumens Per Lamp 50 RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. Width - Mtg. Ht. above work plane) Room Surface Reflectances: 80% Ceiling; 50% Walls; 20% Floor 40 30 20 INITIAL FOOTCANDLES INITIAL FOOTCANDLES Page 2 of 2 150 Watt A-21 2880 Lumens Per Lamp 50 RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. Width - Mtg. Ht. above work plane) Room Surface Reflectances: 80% Ceiling; 50% Walls; 20% Floor 40 30 20 10 10 50 5 6 7 100 150 200 AREA PER FIXTURE IN SQUARE FEET 8 9 10 10 11 12 20 25 13 5 14 Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factor: 150W A21 (Gold): F.C. x 0.90. SPACING RATIO= 1.2 6 60 80 100 120 140 160 AREA PER FIXTURE IN SQUARE FEET 7 8 9 0 2 1/2 7 1/2 12 1/2 17 1/2 22 1/2 27 1/2 32 1/2 37 1/2 42 1/2 45 47 1/2 52 1/2 55 57 1/2 60 800 1200 30 1600 I.T.L. REPORT NO. 11514 DATE: 3-4-69 80 70 1654 1647 1602 1567 1471 1474 1457 1230 706 282 0 39 115 186 243 309 369 362 236 104 107 15 43 7 2 ZONAL SUMMARY 1 60 800 1200 13 30 ZONE LUMENS LAMP 0-30 0-40 0-60 0-90 90-180 0-180 1261 1859 2014 2014 0 2014 45.5 67.1 72.7 72.7 0 72.7 50 50 .80 .76 .71 .68 .63 .59 .55 .53 .49 .46 30 .79 .73 .68 .64 .59 .56 .52 .49 .45 .42 10 .77 .72 .66 .61 .57 .53 .49 .46 .42 .39 50 .77 .73 .69 .66 .62 .58 .55 .52 .48 .45 30 .76 .72 .67 .63 .59 .55 .51 .48 .45 .42 10 .75 .70 .65 .61 .57 .53 .49 .46 .42 .39 50 .74 .71 .68 .64 .61 .57 .54 .51 .48 .45 171 469 629 347 74 11 7 1 0 0 ZONAL SUMMARY FIXT ZONE 62.6 92.2 100.0 100.0 0 100.0 0-30 0-40 0-60 0-90 90-180 0-180 I.T.L. REPORT NO. 18421 DATE: 10-2-74 10 0 LUMENS LAMP 1271 1619 1704 1714 0 1714 44.1 56.2 59.1 59.5 .0 59.5 FIXT 74.1 94.4 99.4 100.0 0 100.0 COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE REPORT NO. 18421C 30 1822 1810 1660 1360 553 95 12 7 1 0 0 1600 80 70 50 30 10 0 % WALL REFLECTANCE 30 .73 .70 .66 .62 .58 .55 .51 .48 .44 .41 10 .73 .69 .64 .60 .56 .53 .49 .46 .42 .39 50 .72 .69 .67 .63 .60 .57 .53 .50 .47 .44 30 .72 .68 .64 .61 .58 .54 .50 .47 .44 .41 10 .71 .67 .63 .59 .55 .52 .48 .46 .42 .39 20% FLOOR CAVITY REFLECTANCE Conversion Factor: For 150W A21 units with gold reflector, multiply C.U.’s by 0.9. 0 .69 .66 .62 .58 .54 .51 .48 .44 .41 .38 ROOM CAVITY RATIO ROOM CAVITY RATIO 12 0 5 15 25 35 45 55 65 75 85 90 400 % WALL REFLECTANCE 10 .79 .72 .66 .62 .57 .53 .50 .46 .42 .39 11 CANDLEPOWER SUMMARY DEG CP ZONAL FLUX 90 COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE 30 .80 .74 .69 .65 .60 .56 .52 .49 .45 .42 10 Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factor: 100W A19 (MG): F.C. X 0.55, 100W A19 (BK): F.C. X 0.60 CANDLEPOWER SUMMARY DEG CP ZONAL FLUX 400 50 .82 .77 .72 .68 .64 .60 .56 .53 .49 .46 10 180 SPACING RATIO= 1.0 90 REPORT NO. 11514C 40 CENTER TO CENTER DISTANCE OF FIXTURES IN FEET CENTER TO CENTER DISTANCE OF FIXTURES IN FEET 1 2 3 4 5 6 7 8 9 10 B7054BK 60 1 2 3 4 5 6 7 8 9 10 50 .66 .62 .58 .55 .51 .48 .46 .43 .40 .37 30 .65 .60 .55 .51 .48 .45 .42 .39 .36 .34 10 .64 .58 .53 .49 .45 .43 .40 .37 .34 .31 50 .65 .61 .57 .54 .51 .48 .45 .42 .40 .37 30 .64 .59 .55 .51 .48 .45 .42 .39 .36 .34 10 .63 .57 .53 .49 .45 .42 .40 .37 .34 .31 50 .63 .59 .56 .53 .50 .47 .44 .42 .39 .36 30 .62 .57 .54 .50 .47 .44 .42 .39 .36 .33 10 .61 .56 .52 .48 .45 .42 .40 .37 .34 .31 50 .60 .57 .54 .51 .49 .46 .44 .41 .38 .36 30 .60 .56 .53 .49 .46 .44 .41 .38 .36 .33 10 .59 .55 .51 .48 .44 .42 .39 .37 .34 .31 50 .58 .56 .53 .50 .48 .45 .43 .41 .38 .36 30 .58 .54 .52 .49 .46 .43 .41 .38 .35 .33 10 .57 .54 .50 .47 .44 .42 .39 .36 .34 .31 0 .56 .53 .50 .46 .43 .41 .38 .36 .33 .30 20% FLOOR CAVITY REFLECTANCE Conversion Factor: For 100W A19 units with gold reflector, multiply C.U.’s by 0.9. Job Information Type: Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902