Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Earth Leakage Lockout - Frozen Contactor Leaders in Innovative Protection Systems, Bramco’s ellfc3 is compliant to the latest statutory and industry standards. The ellfc3 provides next generation Earth Leakage Lockout and Frozen Contactor Protection. In addition, it also monitors Phase Rotation, Phase Loss and Undervoltage. Application: ELL - Earth Leakage Lockout: monitors earth leakage on conductors in an outgoing load circuit before load contactor is closed and to prevent closing the contactor if the earth-leakage resistance is below pre-selected level. (1MΩ) FC - Frozen Contactor: monitors voltage on the outgoing load circuit when the load contactor is open, identifying leaky vacuum contactor or welded contactor, then initiate isolation of the incoming supply via circuit breaker back tripping. UV, Phase Loss, Phase Rotation - Incorrect phase rotation, phase loss or undervoltage will cause the UV relay to close with no latch. Features: ELL: • Failsafe operation – relay opens on fault • 1 MΩ • Common AR interlock contact input • Separate contacts (2) FC: • Non-Failsafe operation – relay closes on fault • Adjustable Timer inhibit for motor loads • More than 25VAC/60VDC on any phase will cause trip • Common AR interlock contact input • Separate contacts (2) UV, Phase Loss, Phase Rotation: • Phase rotation - CW/CCW down to 30% phase V • UV Trip <70% of present phase V on any phase • UV trip - 1 sec, non-failsafe, no latch • LED indicators for each of these • Separate contact (1) Isolation Barrier: • Isolation Barrier and AR contact inputs are common to the ellfc3 relay. • Barrier monitored for integrity – causes trip if not connected or if no phase voltage present during normal operation. = Complies to latest Standards © Copyright Bramco International Pty Ltd Specifications subject to change without notice March15 Specifications: Supply: Voltage Tolerance: • • • • • • 110-240VAC 50/60Hz 24-48VAC/DC 3VA -25% + 20% -50% for 2 seconds 0 – 60° C 415V or 1100V 3VA Operating Temp: System Voltage: ELL range: • 1 MΩ • 2 x C.O. 5A 250VAC contacts 5A 250VAC (General) 5A 30VDC (Resistive) (100VA Max) FC – Leakage voltage: • 25VAC or 60VDC or more • 2 x C.O. 5A 250VAC contacts 5A 250VAC (General) 5A 30VDC (Resistive) (100VA Max) • Trip time - 1 sec UV, PL, PR: • 1 x C.O. 5A 250VAC contacts 5A 250VAC (General) 5A 30VDC (Resistive) (100VA Max) FC Timer: • Inhibit range 1 – 20 seconds Enclosure Dimensions: • 100mmW x 75mmH x 110mmD • High impact resistant polycarbonate Material: construction • IP20 Rating Mounting: • DIN rail or screw mounting Terminals: • Cage screw terminals Weight: • 300gms Earth Leakage Lockout - Frozen Contactor Connection Diagram: AC SUPPLY L1 L2 L3 ELL CONTACTS N/C COM N/O 12 13 14 15 11 N/O 8 COM 7 10 N/C COM 6 Barrier N/C N/O 5 9 COM 4 ELL N/O N/C 3 2 1 EARTH V in Power FC CONTACTS Rotation FC Phase OK OK CW A Trip Trip CCW B AR 4 3 5 8 11 14 17 UV/Rotation Trip 2 1 20 ellfc3 FC Delay seconds N/O COM N/C A-ELV B-ELV C-ELV E BAR3 415 - 1100V EARTH RESTRAINED RECEPTICAL Outline and Mounting Hole Dimensions 19 Aruma Place, Cardiff NSW 2285 AUSTRALIA 100 mm 62.5mm 110mm 110mm 75mm 85mm Ordering Information: A01220 - ellfc3 Relay - 110-240VAC A01222 - ellfc3 Relay - 24-48VAC/DC A01180 - BAR3 415 - 1100VAC Isolation Barrier © Copyright Bramco International Pty Ltd Specifications subject to change without notice March15 Bramco Contacts Telephone +61 2 4954 4721 Email [email protected] www.bramco.com.au Compliance: AS/NZS 2081:2011 The ellfc3 comes with a 2 year warranty. C-ELV B-ELV Voltage Trip 30 A-ELV UV 29 EARTH COM 28 26 N/O 27 25 N/C 415V Link 24 23 2 CORE SCREENED CABLE 22 A01180 A B C 21 LATCH RESET FCRESET PB1 MC 20 19 2 CORE SCREENED CABLE SCREEN AR SWNO 18 MC1 AR AR MC1 17 16 MC1 C