Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

M2202 Series Damper Actuators •S  imple direct coupling reduces installation and commissioning time while improving reliability by eliminating damper linkages •R  eversible mounting design — enables the actuator to spring return in either direction • Robust 18 lb-in (2 Nm) torque rating • 3 5 to 95° CW or CCW adjustable stroke mechanically limited to 95° • Floating and proportional models have DA / RA switch • Electronic stall detection throughout entire rotation range extends the life of the actuator by deactivating the actuator motor when an overload condition is detected • Rated for 60,000 full stoke cycles, 1,500,000 repositions (AGx, GGx models) • Integral 39 in. (1 m) cables with colored conductors — simplify field wiring •O  n-off, floating and DC 2...10 V proportional control • Integral auxiliary switch (xxB Models) — provide one adjustable switch point with line voltage capability •R  emovable coupler — adapts to a shorter damper shaft • cULus Listed, CE Mark code number control type torque/timing/voltage auxiliary switches on-off / floating 18 lb-in (2 nm) 95 sec running < 25 sec spring m2202-agb-2 ac/dc 24 v 50/60 hz m2202-aga-2 comments 36” (.9m) cable w/colored conductors 1-spdt 2 - 36” (.9m) cable w/colored conductors none 36” (.9m) cable w/colored conductors m2202-bab-2 ac 100...240 v 50/60 hz 1-spdt 2 - 36” (.9m) cable w/colored conductors m2202-bga-2 18 lb-in (2 nm) < 75 sec running < 25 sec spring m2202-bgb-2 ac/dc 24 v 50/60 hz none 36” (.9m) cable w/colored conductors 1-spdt 2 - 36” (.9m) cable w/colored conductors dc 2 . . . 10 v 18 lb-in (2 nm) m2202-gga-2 proportional 95 sec running < 25 sec spring m2202-ggb-2 ac/dc 24 v 50/60 hz none 36” (.9m) cable w/colored conductors 1-spdt 2 - 36” (.9m) cable w/colored conductors m2202-baa-2 on-off 18 lb-in (2 nm) < 75 sec running < 25 sec spring Dampers none Humidity Sensors m2202 series spring return damper actuators Electric Actuators •F  its 1/4 to 1/2” (6 to 12.7 mm) round or 1/4 to 5/16” (6 to 10 mm) square shafts • DC 2…10 V feedback (GGx models only) Ball Valve m2202 Series Valve Assemblies 2 nm (18 lb-in) spring return damper actuators selection guide 6 nm (53 lb-in) spring return damper actuators selection guide M9206 Series Damper Actuators m9206 Series •S  imple direct coupling reduces installation and commissioning time while improving reliability by eliminating damper linkages. Single screw coupling provides three-point shaft gripping •R  eversible mounting design — enables the actuator to spring return in either direction • Robust 53 lb-in (6 Nm) torque rating • 3 4.5 to 90° CW or CCW adjustable stroke mechanically limited to 93° •F  its 3/8 to 1/2” (10 to 13 mm) round or 3/8” (10 mm) square shaft •A  uto calibration feature adapts the actuator to the damper stroke •O  n-off, floating and DC 0(2)...10 V proportional control • DC 0(2)…10 V feedback (GGx models only) •R  emovable coupler — adapts to a shorter damper shaft • Floating and proportional models have DA / RA switch • Electronic stall detection throughout entire rotation range extends the life of the actuator by deactivating the actuator motor when an overload condition is detected • Rated for 60,000 full stoke cycles (all models), 1,500,000 repositions (AGx, GGx models) • Integral 39 in. (1 m) cables with colored conductors — simplify field wiring • Integral auxiliary switch (xxB Models) — provide one adjustable switch point with line voltage capability • cULus Listed, CE Mark m9206 series spring return damper actuators code number control type torque/timing/voltage auxiliary switches m9206-aga-2s on-off / floating 53 lb-in (6 nm) 60 or 90 sec timing ac/dc 24 v 50/60 hz comments none 48 in. (1.2m) 18 awg plenum rated ul cmp cable 1-spdt 48 in. (1.2m) 18 awg plenum rated ul cmp cable; aux switch 48 in. (1.2m) 18 awg h.f. awm cable none 48 in. (1.2m) 18 awg h.f. awm cable m9206-bab-2s 1-spdt 48 in. (1.2m) 18 awg h.f. awm cable(s) m9206-bga-2s 53 lb-in (6 nm) 10 - 40 sec timing ac 24 v 50/60 hz m9206-bgb-2s none 48 in. (1.2m) 18 awg h.f. awm cable 1-spdt 48 in. (1.2m) 18 awg h.f. awm cable(s) dc 2 . . . 10 v 53 lb-in (6 nm) m9206-gga-2s proportional 25 - 40 sec timing ac/dc 24 v 50/60 hz m9206-ggb-2s none m9206-agb-2s m9206-baa-2s on-off 53 lb-in (6 nm) 10 - 40 sec timing ac 120 v 60 hz 1-spdt 48 in. (1.2m) 18 awg ul cmp plenum cable(s) with 1/4 in. (6mm) stripped wire leads 48 in. (1.2m) 18 awg plenum rated ul cmp cable; aux switch 48 in. (1.2m) 18 awg h.f. awm cable © 2007 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA PUBL-4095 www.johnsoncontrols.com