LC-P12200 For standby power supplies Expected trickle life: 6 years at 25℃ 10 years at 20℃ ■Dimensions(mm) Terminal type
※Contents indicated (including the recycle marking,etc) are subject to change without notice.
Battery case resin: Flame-retardant (UL94V-0)
■Duration of discharge vs. discharge current
■Specification 12V 200Ah 533 mm 237 mm 211 mm 216 mm 57.0 kg M8 threaded post
30 20
Capacity (25 ℃)
200Ah 185Ah 169Ah 118Ah
Internal Resistance (25 ℃)
Fully charged battery
3 mΩ
40 ℃ 25 ℃ 0℃ -15 ℃ After 3 months After 6 months After 12 months
102% 100% 85% 65% 91% 82% 64%
Temperature Dependency of Capacity (20 hour rate) Self Discharge (25 ℃)
(hour)
5
25℃
3
0℃
60 30 (minute)
■Characteristics 20 hour rate 10 hour rate 3 hour rate 1 hour rate
40℃
10 Duration of discharge
Nominal Voltage Rated Capacity(20HR) Length Width Dimensions Height Total height Approx. Mass Terminal
-15℃
10 5 3
1
1
3
100 300 10 30 Discharge current(A)
■Watt Table(25℃)
(Wattage/Battery)
Cut-off V
5min
10min 15min 20min 30min 45min
9.6V
6552
5160
4200
3356
2496
1h
1.5h
2h
3h
4h
5h
6h
10h
20h
1772
1432
1053
867
643
504
420
345
225
123
9.9V
6403
5036
4092
3277
2430
1725
1386
1015
853
630
495
410
340
224
123
10.2V
5643
4649
3966
3175
2352
1674
1336
965
837
618
483
401
333
222
122
10.5V
5092
4390
3851
3085
2308
1634
1296
925
821
608
475
396
331
221
122
10.8V
4462
3876
3725
3017
2253
1573
1246
877
800
592
464
388
325
220
121
■Ampere Table(25℃)
(Ampere/Battery)
Cut-off V
5min
1h
1.5h
2h
3h
4h
5h
6h
10h
20h
9.6V
655
471
366
297
222
163
130
95.7
86.0
59.6
45.6
37.0
30.2
19.0
10.1
10min 15min 20min 30min 45min
9.9V
640
460
357
290
217
159
126
92.3
84.6
58.5
44.8
36.1
29.8
18.9
10.1
10.2V
564
425
346
281
210
154
121
87.7
83.0
57.3
43.7
35.3
29.2
18.8
10.0
10.5V
509
401
336
273
206
150
118
84.1
81.5
56.4
43.0
34.9
29.0
18.7
10.0
10.8V
446
354
325
267
201
145
113
79.7
79.4
54.9
42.0
34.1
28.4
18.5
9.99
1/2
1000
■Charging Method
(25℃)
■Cut off voltage
Control voltage:13.6-13.8V Initial current:30.0A or smaller
Trickle use
■Influence of Temperature on Trickle life
Discharge current
10.0A- 40.0A- 100A- 200A40.0A 100A 200A 400A
Cut off voltage(V)
10.5
Capacity Retention Ratio (%)
Service Life (Years)
8.7
9.3
Charging Voltage 2.275V/Cell
1
120 100 80
5℃ (41℉)
60 40℃ (104℉)
40
30℃ (86℉)
25℃ (77℉)
20 0
0.1 10
20 30 40 Temperature (℃)
50
■Constant-voltage constant-current charge characteristics for Trickle use 160
0.1
Charge Quan tity (to-D ischarge Quantity
100
① Discharge — — 100% (0.05CA*20H) — — 50% (0.05CA*10H) ② Charge Charge Voltage: 13.7V(2.28V/Cell)
80 60 40
Charge Current: 0.15CA ③ Temperature: 25℃ (77℉ )
20
4
6 8 10 12 14 16 Storage Period (Month)
18
12.0 10.0 8.0 6.0 4.0
20
120
14.0 Battery Voltage(V)
0.2
120
2
■Discharge capacity by temperature and by discharge current
16.0 B attery Voltage
140 Charge Quantity(%)
0.3
0
60
100
0.05CA 0.10CA
80
0.25CA 0.50CA
60
1.00CA 2.00CA 3.00CA
Capacity(%)
0
Charge Current(CA)
9.9
■Residual capacity test result
100
10
10.2
400A600A
40
2.0
20
0.0
0
C harge Cu rren t
0
0 0
4
8 12 16 20 Char ge Tim e (H)
24
-15
0
15 30 Battery temperature(℃)
45
■Discharge characteristics(25℃)
Terminal voltage(V)
20.0
15.0
10.0
50.0A 600A
19.0A
10.0A
400A
5.0
0.0
0
1
2
4
6
8 10
20
40
60
2
(minute)
4
6
8 10
20
40
(hour) Duration of discharge
! Caution Due to the potential energy stored in the batteries, Please read《Precautions for handling the Rechargeable Valve Regulated Lead Acid Batteries》 before using batteries. If improper handling or use of the batteries without understanding《Precautions for handling the Rechargeable Valve Regulated Lead Acid Batteries》may result in bodily injury caused by electrolyte leakage, heat generation, or explosion.
Panasonic Storage Battery (Shenyang) Co., Ltd NO. 51 Kunminghu Street, Shenyang Economic & Technical Development Zone,110141 China Tel: 86 24 25818921 Fax: 86 24 62786318 Website:
2010.11
http://www.panasonicbattery.cn 2/2