Fresh Air Enclosure Cooling Filter Fans COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS
SPEC-00740 I 63.422.2211 7 763.576.3200
SF SIDE-MOUNT
SF04 16 CFM (28 m3/hr.)
SF05 39 CFM (66 m3/hr.)
SF13 376 CFM (638 m3/hr.)
SF09 75 CFM (127 m3/hr.)
SF13 473 CFM (803 m3/hr.)
INDUSTRY STANDARDS CE, CSA (entire fan assembly excluding VDC models) Type 12, IP54 standard Type 12, IP 55 optional
APPLICATION
• • • • • • • •
1
ize rage from 4 in. (102 mm) to 13 in. (325 mm) S Free air flow from 16 CFM (28 m 3 /hr.) to 571 CFM (920 m 3 /hr.) S ervice life hours from 40000 to 70000 hours Operating temperature range fo -4 F/-20 C to 149 F/65 C
FINISH
AL 7035 light-gray, UV-resistant plastic standard R R AL 9011 black, UV-resistant plastic optional
ACCESSORIES • • •
lick-fit design quickly installs into enclosure wall; no tools or C screws required Simple snap-open grille for easy filter replacement Enclosure side wall mounting Reverse airflow option on SF13 models available to push/pull air through higher static pressure Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers Terminal wire connections Optional thermostat available to save energy and extend service life
Cooling
• • • •
• •
Industrial automation Automotive assembly P ackage handling equipment Food and beverage process controls W ind energy systems
FEATURES
SF13 571 CFM (970 m3/hr.)
SPECIFICATIONS
UL/cUL recognized; File No. 235470
• • • • •
SF10 162 CFM (275 m3/hr.)
Replacement filters T hermostat Rain shroud
NOTES
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Thermostat Catalog Number
115 50 / 60 1.40/1.20 12 / 11
230 50 / 60 0.70 12
24 — 0.10 2.2
48 — 0.054 2.6
SF0416414
SF0426414
SF0424414
SF0448414
SF0416413 16 / 28 10/17 12/21
SF0426413 16 / 28 10/17 12 / 21
SF0424413 16 / 28 10/17 12 / 21
SF0448413 16 / 28 10/17 12 / 21
2700 / 3200 30
2700 / 3200 30
3300 36
3300 36
131 / 55 14 / -10 37,500
Lead Wires
131 / 55 149 / 65 14 / -10 -4 / -20 37,500 70,000 4.13 x 4.13 x 2.17 / 105 x 105 x 55 3.62 x 3.62 / 92 x 92 .73 / .33
149 / 65 -4 / -20 70,000
SG0400404 SG0400403 10100059H TWR60
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
2
Fresh Air Enclosure Cooling Filter Fans
SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan Performance Curve Volume Flow (CFM) 0
3
6
9
15
12
17
40
.16
35
.14
30
.12
60 Hz
04 SF
IP
50
54
Hz IP
20
.08
54
Static Pressure (Pa)
.10
4 G0
15
IP
54
.06
S
10
Static Pressure (in. H2O)
04 SF
25
.04 2x
5
54 4 IP
SG0
.02
0
0 0
5
10
15
20
25
30
Volume Flow (m³/hr.)
3
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
)LOWHU)DQ6)&)0PuKU
; ;
%$&.9,(: (;+$867*5,//(
6,'(9,(:
;
&87287',0(16,216
2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
4
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANSRAL 7035 Light Gray: RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 0.23 20
230 50 / 60 0.11 20
24 — 0.17 4.1
48 — 0.08 3.5
SF0516414
SF0526414
SF0524414
SF0548414
SF0516413 39 / 66 26 / 44 30 / 51
SF0526413 39 / 66 26 / 44 30 / 51
SF0524413 39 / 66 26 / 44 30 / 51
SF0548413 39 / 66 26 / 44 30 / 51
SF0516514
SF0526514
SF0524514
SF0548514
SF0516513 36 / 61 24 / 40 28 / 47
SF0526513 36 / 61 24 / 40 28 / 47
SF0524513 36 / 61 24 / 40 28 / 47
SF0548513 36 / 61 24 / 40 28 / 47
2650 / 3100 42
2650 / 3100 42
3050 42
3050 42
131 / 55 14 / -10 27,500
Terminal Block
131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 5.83 x 5.83 x 2.56 / 148 x 148 x 65 4.92 x 4.92 / 125 x 125 1.19 / .54
149 / 65 -4 / -20 50,000
SG0500404 SG0500403 SG0500504 SG0500503 10100060 10100064H TWR60 SH05GS35001, SH05GS61001, SH05SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
5
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan Performance Curve 35
41 .28 .24
SF
05
40
.20
SF
05
50
Hz
60
Hz
IP
30
IP
54
.16 54
.12
4
P5
I 05
SG
20
2
10 0
10
20
50 30 40 Volume Flow (m³/hr.)
5
0 x SG
60
4 IP 5
.08
05
40
.20
SF
SF
05
50
Hz
30
60
IP
Hz
55
IP
10
0
0
.16
55
.12
5
P5
I 05
SG
20
.04 70
41 .28 .24
50 Static Pressure (Pa)
Static Pressure (Pa)
50
35
60 Static Pressure (in. H2O)
60
0
TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70
2
0
10
20
50 30 40 Volume Flow (m³/hr.)
05 x SG
Static Pressure (in. H2O)
TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70
5
IP 5
60
.08 .04 70
0
),/7(5)$1
%$&.9,(: (;+$867*5,//(
;
6,'(9,(:
&87287
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
6
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 0.23 20
230 50 / 60 0.11 20
24 — 0.17 4.1
48 — 0.08 3.5
SF0916414
SF0926414
SF0924414
SF0948414
SF0916413 75 / 127 59 / 100 67 / 114
SF0926413 75 / 127 59 / 100 67 / 114
SF0924413 75 / 127 59 / 100 67 / 114
SF0948413 75 / 127 59 / 100 67 / 114
SF0916514
SF0926514
SF0924514
SF0948514
SF0916513 70 / 118 54 / 92 62 / 106
SF0926513 70 / 118 54 / 92 62 / 106
SF0924513 70 / 118 54 / 92 62 / 106
SF0948513 70 / 118 54 / 92 62 / 106
2650 / 3100 51
2650 / 3100 51
3050 51
3050 51
131 / 55 14 / -10 27,500
Terminal Block
131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 8.03 x 8.03 x 3.54 / 204 x 204 x 90 6.97 x 6.97 / 177 x 177 1.74 / .79
149 / 65 -4 / -20 50,000
SG0900404 SG0900403 SG0900504 SG0900503 10100061 10100065H TWR60 SH09GS35001, SH09GS61001, SH09SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
7
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan Performance Curve
,3
20
6*
[
10 0
20
100 40 60 80 Volume Flow (m³/hr.)
3 ,
120
.12
40
.20
+]
,3
.16
30
.08
20
.04
10 0
0 140
30
.16
6*
50
,3 ]
,3
+
+]
.24
6)
.20
+]
60
40
.28
Static Pressure (Pa)
6)
50
Static Pressure (in. H2O)
.24
6)
,3
60
0
70
.28
6)
Static Pressure (Pa)
70
82 .32
71
6*
[
0
20
.12
40
100 60 80 Volume Flow (m³/hr.)
,3
Static Pressure (in. H2O)
82 .32
,3
71
TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80
6*
TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80
.08 .04
120
0 140
)LOWHU)DQ6)&)0PuKU
%$&.9,(: (;+$867*5,//(
;
&87287',0(16,216
6,'(9,(:
2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
8
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF10 162 CFM (275 m3/Hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 .53 / .50 43 / 40
230 50 / 60 .30 / .25 45 / 39
24 — 0.66 16
48 — 0.33 16
SF1016414
SF1026414
SF1024414
SF1048414
SF1016413 162 / 275 133 / 226 149 / 253
SF1026413 162 / 275 133 / 226 149 / 253
SF1024413 162 / 275 133 / 226 149 / 253
SF1048413 162 / 275 133 / 226 149 / 253
SF1016514
SF1026514
SF1024514
SF1048514
SF1016513 149 / 253 122 / 207 137 / 233
SF1026513 149 / 253 122 / 207 137 / 233
SF1024513 149 / 253 122 / 207 137 / 233
SF1048513 149 / 253 122 / 207 137 / 233
2760 / 3030 52
2760 / 3030 52
2950 52
2950 52
131 / 55 14 / -10 40,000
Terminal Block
131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 9.84 x 9.84 x 4.72 / 250 x 250 x 120 8.78 x 8.78 / 223 x 223 4.19 / 1.9
131 / 55 14 / -10 40,000
SG1000404 SG1000403 SG1000504 SG1000503 10100062 10100066H TWR60 SH10GS35001, SH10GS61001, SH10SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
9
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
SF10 162 CFM (275 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan 47
Volume Flow (CFM) 118 71 94
TYPE 12 / IP 55 Filter Fan 141
165
0
24
47
Volume Flow (CFM) 118 71 94
141
165
120
.48
120
.48
.40
100
,3
,3
+ ]
+] 6)
80
.32
60
.24
40
.16
,3
6*
20
.08
,3 [6*
0 0
40
80
200 120 160 Volume Flow (m³/hr.)
Static Pressure (Pa)
.56
Static Pressure (in. H2O)
140
,3 +] ,3 +] 6) 6)
.56
6)
140
100 Static Pressure (Pa)
24
80 60
.40 .32 .24
40
.16
2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\
.08
240
0 280
(;+$867*5,//(
,3
6*
20
,3 [6*
0 0
40
80
200 120 160 Volume Flow (m³/hr.)
)LOWHU)DQ6)&)0PuKU
%$&.9,(:
Static Pressure (in. H2O)
0
240
0 280
6,'(9,(:
;
&87287',0(16,216
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
10
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 .58 / .70 64 / 80
230 50 / 60 .29 / .35 64 / 80
24 48 — — 2.60 1.30 55 55 Terminal Block
115 Rvrs 50 / 60 .58 / .70 64 / 80
230 Rvrs 50 / 60 .29 / .35 64 / 80
SF1316414
SF1326414
SF1324414
SF1348414
SF1316414R
SF1326414R
SF1316413 375 / 638 249 / 423 333 / 565
SF1326413 375 / 638 249 / 423 333 / 565
SF1324413 375 / 638 249 / 423 333 / 565
SF1348413 375 / 638 249 / 423 333 / 565
SF1316413R 375 / 638 249 / 423 333 / 565
SF1326413R 375 / 638 249 / 423 333 / 565
SF1316514
SF1326514
SF1324514
SF1348514
—
—
SF1316513 346 / 587 228 / 387 301 / 511
SF1326513 346 / 587 228 / 387 301 / 511
SF1324513 346 / 587 228 / 387 301 / 511
SF1348513 346 / 587 228 / 387 301 / 511
— — — —
— — — —
2550 / 2800 60
2550 / 2800 60
2950 60
2950 60
2550 / 2800 60
2550 / 2800 60
131 / 55 14 / -10 40,000
131 / 55 14 / -10 40,000
131 / 55 14 / -10 40,000
131 / 55 14 / -10 40,000
140 / 60 140 / 60 -13 / -25 -13 / -25 40,000 40,000 12.72 x 12.72 x 5.83 / 323 x 323 x 148 11.5 x 11.5 / 292 x 292 7.5 / 3.4 SG1300404 SG1300403 SG1300504 SG1300503
10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
11
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan
294
180
180
412 .72
160
.64
160
.64
140
.56
140
.56
.48
120
118
353
0 200
500 300 400 Volume Flow (m³/hr.)
Static Pressure (Pa)
40
.08
20
.24 .16
0
100
200
.08
,3
* [6
0
500 300 400 Volume Flow (m³/hr.)
)LOWHU)DQ6)&)0PuKU
600
700
;
6,'(9,(:
%$&.9,(: (;+$867*5,//(
*
6
0
700
.32
,3
60
.16
0 600
80
3
3
*,
[6
.40
] ,
20
100
3 ],
40
.48
+
.24
+ 6)
,3
6*
60
Static Pressure (in. H2O)
3
3 ],
+
],
+
.32
100
59
6)
.40
80
0
0
6)
6)
100
353
Volume Flow (CFM) 177 235
412 .72
120 Static Pressure (Pa)
59
TYPE 12 / IP 55 Filter Fan 294
Static Pressure (in. H2O)
0
Volume Flow (CFM) 118 177 235
&87287',0(16,216
2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
12
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 1.02 / 1.4 115 / 166
230 50 / 60 .51 / .74 115 / 175 Terminal Block
400 50 / 60 .22 /. 26 110 / 150
SF1316424
SF1326424
SF1340424
SF1316423 473 / 803 343 / 583 399 / 677
SF1326423 473 / 803 343 / 583 399 / 677
SF1340423 473 / 803 343 / 583 399 / 677
SF1316524
SF1326524
SF1340524
SF1316523 436 / 740 314 / 533 369 / 627
SF1326523 436 / 740 314 / 533 369 / 627
SF1340523 436 / 740 314 / 533 369 / 627
2450 / 2650 70
2550 / 2750 70
2650 / 2900 70
131 / 55 14 / -10 40,000
131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162 11.50 x 11.50 / 292 x 292 7.72 / 3.5
131 / 55 14 / -10 40,000
SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
13
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan
TYPE 12 / IP 55 Filter Fan
59
118
177
235
294
353
Volume Flow (CFM) 412
471
530 589
0
59
118
177
235
294
353
412
471
530 589
225
.90
200
.80
200
.80
175
.70
175
.70
100
200
300
400
500
600
700
800
0
25 0
,3
+]
50
,3
.30
100
.40
75
.20
50
.10
25
0 900 1000
.50
,3
6*
,3
* [6
75
+]
.40
100
125
.60
.50
150
,3
+]
,3
+]
,3
* 6
6)
125
.60
6)
6)
150
Static Pressure (Pa)
.90
Static Pressure (in. H2O)
225
6)
Static Pressure (Pa)
0
,3
6* [
.30 .20 .10
0 0
Volume Flow (m³/hr.)
Static Pressure (in. H2O)
Volume Flow (CFM)
100
200
300
400
500
600
700
800
0 900 1000
Volume Flow (m³/hr.)
)LOWHU)DQ6)&)0PuKU
%$&.9,(: (;+$867*5,//(
5
6,'(9,(:
;
&87287',0(16,216
2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
14
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12/IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 Rvrs 50 / 60 1.05 / 1.5 120 / 175
230 Rvrs 50 / 60 .51 / .70 115 / 165 Terminal Block
400 Rvrs 50 / 60 .22 / .26 110 /1 50
SF1316424R
SF1326424R
SF1340424R
SF1316423R 473 / 803 343 / 583 399 / 677
SF1326423R 473 / 803 343 / 583 399 / 677
SF1340423R 473 / 803 343 / 583 399 / 677
2450 / 2650 70
2550 / 2750 70
2650 / 2900 70
131 / 55 14 / -10 40,000
131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162) 11.50 x 11.50 / 292 x 292) 7.72 / 3.5
131 / 55 14 / -10 40,000
SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
15
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 1.02 / 1.47 115 / 175
230 50 / 60 .6 / .92 135 / 215
24 — 5.00 105 Terminal Block
48 — 2.60 105
400/460 50 / 60 .25 / .27 113 / 172
SF1316434
SF1326434
SF1324434
SF1348434
SF1346434
SF1316433 571 / 970 377 / 640 454 / 770
SF1326433 571 / 970 377 / 640 454 / 770
SF1324433 571 / 970 377 / 640 454 / 770
SF1348433 571 / 970 377 / 640 454 / 770
SF1346433 571 / 970 377 / 640 454 / 770
SF1316534
SF1326534
SF1324534
SF1348534
SF1346534
SF1316533 526 / 893 345 / 586 415 / 705
SF1326533 526 / 893 345 / 586 415 / 705
SF1324533 526 / 893 345 / 586 415 / 705
SF1348533 526 / 893 345 / 586 415 / 705
SF1346533 526 / 893 345 / 586 415 / 705
2600 / 2850 70
2650 / 2950 69
2750 70
2750 70
2650 / 3050 73
140 / 60 5 / -15 40,000
140 / 60 140 / 60 140 / 60 5 / -15 5 / -15 5 / -15 40,000 40,000 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6
140 / 60 5 / -15 40,000
SG1300404 SG1300403 SG1300504 SG1300503 1010063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
16
Fresh Air Enclosure Cooling Filter Fans
SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan Performance Curve
200
.80
.70
175
.70
.60 .50
*
,3
125
.40
[
6
100
.30
75 50 25
,3
* [6
0 0
100
200
300
400
500
600
700
800
150 125
.60
100
50
.10
25
.50 .40
75
.20
0 900 1000
,3
,3
,3
471
]
]
] +
+
177
+
,3
Static Pressure (Pa)
.80
6)
150
530 589 .90
+]
175
118
6)
6)
225
6)
200
59
,3
225
0
Volume Flow (CFM) 235 294 353 412
530 589 .90
471
[ 6*
118
Static Pressure (Pa)
59
TYPE 12 / IP 55 Filter Fan
Static Pressure (in. H2O)
0
Volume Flow (CFM) 177 235 294 353 412
6*
[
,3
.30
Static Pressure (in. H2O)
TYPE 12 / IP 54 Filter Fan
.20 .10
0 0
Volume Flow (m³/hr.)
100
200
300
400
500
600
700
800
0 900 1000
Volume Flow (m³/hr.)
)LOWHU)DQ6)&)0PuKU
%$&.9,(: (;+$867*5,//(
2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\
6,'(9,(:
;
&87287',0(16,216
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
17
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Performance Data SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 1.02 / 1.47 115 / 175
230 50 / 60 .6 / .92 135 / 215 Terminal Block
400/460 50 / 60 .25 / .27 113 / 160
SF1316434R
SF1326434R
SF1340434R
SF1316433R 571 / 970 377 / 640 454 / 770
SF1326433R 571 / 970 377 / 640 454 / 770
SF1346433R 571 / 970 377 / 640 454 / 770
2600 / 2850 70
2650 / 2950 69
2650 / 3050 73
140 / 60 5 / -15 40,000
140 / 60 5 / -15 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6
140 / 60 5 / -15 40,000
SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
18
Fresh Air Enclosure Cooling Filter Fans
ST THIN SIDE-MOUNT
ST10 100 CFM (170 m3/hr.)
INDUSTRY STANDARDS
SPECIFICATIONS
UL/cUL recognized; File no. 235470 CE, CSA (entire fan assembly excluding VDC and ST13 models) Type 12, IP54 standard Type 12, IP55 optional
APPLICATION • • • • •
• • • • • • • • •
19
ree airflow from 100 CFM (170 m 3 /hr.) to 303 CFM (515 m 3 /hr.) F S ervice life hours range from 40000 to 57500 Operating temperature range of -4 F / -20 C to 149 F / 65 C
FINISH • •
• • •
AL 7035 light-gray UV-resistant plastic standard R R AL 9011 black UV-resistant plastic optional
Replacement filters T hermostat Rain shroud
NOTES
T13 has reverse airflow option available to push/pull air through S higher static pressure Click-fit design quickly installs into enclosure wall; no tools or screws required T hin depth to minimize cabinet intrusion Enclosure side wall mounting Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers Terminal wire connections Simple snap-open grille for easy filter replacement Optional thermostat available to save energy and extend service life
Cooling
• • •
ACCESSORIES
Industrial automation Automotive assembly P ackage handling equipment Food and beverage process controls W ind energy systems
FEATURES
ST13 303 CFM (515 m3/hr.)
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Performance Data ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 0.2 18
230 50 / 60 0.10 18
24 — 0.27 6.5
48 — 0.14 6.5
ST1016414
ST1026414
ST1024414
ST1048414
ST1016413 100 / 170 74 / 125 84 / 143
ST1026413 100 / 170 74 / 125 84 / 143
ST1024413 100 / 170 74 / 125 84 / 143
ST1048413 100 / 170 74 / 125 84 / 143
ST1016514
ST1026514
ST1024514
ST1048514
ST1016513 92 / 156 67 / 114 77 / 130
ST1026513 92 / 156 67 / 114 77 / 130
ST1024513 92 / 156 67 / 114 77 / 130
ST1048513 92 / 156 67 / 114 77 / 130
2750 / 3100 44
2750 / 3100 44
3150 46
3150 46
131 / 55 14 / -10 40,000
Terminal Block
131 / 55 149 / 65 14 / -10 -4 / -20 40,000 57,500 9.84 x 9.84 x 4.02 / 250 x 250 x 102 8.78 x 8.78 / 223 x 223 2.54 / 1.15
149 / 65 -4 / -20 57,500
SG1000404 SG1000403 SG1000504 SG1000503 10100062 10100066H TWR60 SH10GS35001, SH10GS61001, SH10SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
20
Fresh Air Enclosure Cooling Filter Fans
ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan Performance Curve
74
88
70 60
67
Static Pressure (Pa)
50
67
40
+]
,3
,3
30
103 .28
.24
60
.24
.20
50
.12
20
,3
6*
10
.08
15
67
30
+]
+]
.16
,3
,3
.12
20
0
25
50
125 75 100 Volume Flow (m³/hr.)
.04
0
175
,3 [6*
0
0 150
.08
10
.04
0
,3
6*
,3
[6*
88
.20
67
40
29
74
70
.16
+]
0
Volume Flow (CFM) 44 59
103 .28
Static Pressure (Pa)
15
Static Pressure (In. H2O)
0
Volume Flow (CFM) 44 29 59
Static Pressure (In. H2O)
TYPE 12 / IP 55 Filter Fan
TYPE 12 / IP 54 Filter Fan
25
50
125 75 100 Volume Flow (m³/hr.)
0 150
175
)LOWHU)DQ67&)0PuKU
%$&.9,(: (;+$867*5,//(
6,'(9,(:
;
&87287',0(16,216
2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
21
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Performance Data ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number
115 50 / 60 .58 / .70 64 / 80
230 50 / 60 .29 / .35 64 / 80
ST1316414
ST1326414
ST1316414R
ST1326414R
ST1316413 303 / 515 209 / 355 249 / 422
ST1326413 303 / 515 209 / 355 249 / 422
ST1316413R 303 / 515 209 / 355 249 / 422
ST1326413R 303 / 515 209 / 355 249 / 422
ST1316514
ST1326514
ST1316514R
ST1326514R
ST1316513 277 / 470 191 / 325 219 / 372
ST1326513 277 / 470 191 / 325 219 / 372
ST1316513R 277 / 470 191 / 325 219 / 372
ST1326513R 277 / 470 191 / 325 219 / 372
2550 / 2800 60
2550 / 2800 60
2550 / 2800 60
2550 / 2800 60
131 / 55 14 / -10 40,000
115 50 / 60 .58 / .70 64 / 80 Terminal Block
131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 12.72 x 12.72 x 4.8 / 323 x 323 x 122 11.50 x 11.50 / 292 x 292 7.5 / 3.4
230 50 / 60 .29 / .35 64 / 80
131 / 55 14 / -10 40,000
SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001
Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately.
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
22
Fresh Air Enclosure Cooling Filter Fans
ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan
TYPE 12 / IP 55 Filter Fan
Volume Flow (CFM)
140
.56
140
.56
.48
120
.48
*
60
6
40
200
300
500
400
.16
3
0 100
.24
, *
6
[
20
0
.32
,3
600
100 80
0
59
118
177
235
353
412
.64
.40
,3
.32
* 6
60 40
.08
294
.16
6*
[
.24 ,3
.08
20
0 700
Static Pressure (in. H2O)
.40
Static Pressure (Pa)
353
3 ], + 3 ], + 67 67
Static Pressure (Pa)
235
3 ] , + 3 67 ], + 67
160
80
177
Volume Flow (CFM)
160
100
118
294
412 .64
120
59
Static Pressure (in. H2O)
0
0
0 0
Volume Flow (m³/hr.)
100
200
300
400
500
600
700
Volume Flow (m³/hr.)
)LOWHU)DQ67&)0PuKU
%$&.9,(: (;+$867*5,//(
6,'(9,(:
;
&87287',0(16,216
2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\
Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
23
Cooling
SUBJECT TO CHANGE WITHOUT NOTICE
EQUIPMENT PROTECTION
Spec-00740 I
Fresh Air Enclosure Cooling Filter Fans
Notes
EQUIPMENT PROTECTION
Spec-00740 I
PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com
Cooling
24