Fresh Air Enclosure Cooling Filter Fans COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS SPEC-00740 I 63.422.2211 7 763.576.3200 SF SIDE-MOUNT SF04 16 CFM (28 m3/hr.) SF05 39 CFM (66 m3/hr.) SF13 376 CFM (638 m3/hr.) SF09 75 CFM (127 m3/hr.) SF13 473 CFM (803 m3/hr.) INDUSTRY STANDARDS CE, CSA (entire fan assembly excluding VDC models) Type 12, IP54 standard Type 12, IP 55 optional APPLICATION • • • • • • • • 1  ize rage from 4 in. (102 mm) to 13 in. (325 mm) S Free air flow from 16 CFM (28 m 3 /hr.) to 571 CFM (920 m 3 /hr.) S ervice life hours from 40000 to 70000 hours Operating temperature range fo -4 F/-20 C to 149 F/65 C FINISH  AL 7035 light-gray, UV-resistant plastic standard R R AL 9011 black, UV-resistant plastic optional ACCESSORIES • • •  lick-fit design quickly installs into enclosure wall; no tools or C screws required Simple snap-open grille for easy filter replacement Enclosure side wall mounting Reverse airflow option on SF13 models available to push/pull air through higher static pressure Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers Terminal wire connections Optional thermostat available to save energy and extend service life Cooling • • • • • • Industrial automation Automotive assembly P ackage handling equipment Food and beverage process controls W ind energy systems FEATURES SF13 571 CFM (970 m3/hr.) SPECIFICATIONS UL/cUL recognized; File No. 235470 • • • • • SF10 162 CFM (275 m3/hr.) Replacement filters T hermostat Rain shroud NOTES Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Performance Data  SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Thermostat Catalog Number 115 50 / 60 1.40/1.20 12 / 11 230 50 / 60 0.70 12 24 — 0.10 2.2 48 — 0.054 2.6 SF0416414 SF0426414 SF0424414 SF0448414 SF0416413 16 / 28 10/17 12/21 SF0426413 16 / 28 10/17 12 / 21 SF0424413 16 / 28 10/17 12 / 21 SF0448413 16 / 28 10/17 12 / 21 2700 / 3200 30 2700 / 3200 30 3300 36 3300 36 131 / 55 14 / -10 37,500 Lead Wires 131 / 55 149 / 65 14 / -10 -4 / -20 37,500 70,000 4.13 x 4.13 x 2.17 / 105 x 105 x 55 3.62 x 3.62 / 92 x 92 .73 / .33 149 / 65 -4 / -20 70,000 SG0400404 SG0400403 10100059H TWR60 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 2 Fresh Air Enclosure Cooling Filter Fans SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan Performance Curve Volume Flow (CFM) 0 3 6 9 15 12 17 40 .16 35 .14 30 .12 60 Hz 04 SF IP 50 54 Hz IP 20 .08 54 Static Pressure (Pa) .10 4 G0 15 IP 54 .06 S 10 Static Pressure (in. H2O) 04 SF 25 .04 2x 5 54 4 IP SG0 .02 0 0 0 5 10 15 20 25 30 Volume Flow (m³/hr.) 3 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans )LOWHU)DQ6)&)0 PuKU                 ;   ; %$&.9,(: (;+$867*5,//( 6,'(9,(:  ;  &87287',0(16,216    2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 4 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANSRAL 7035 Light Gray: RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 0.23 20 230 50 / 60 0.11 20 24 — 0.17 4.1 48 — 0.08 3.5 SF0516414 SF0526414 SF0524414 SF0548414 SF0516413 39 / 66 26 / 44 30 / 51 SF0526413 39 / 66 26 / 44 30 / 51 SF0524413 39 / 66 26 / 44 30 / 51 SF0548413 39 / 66 26 / 44 30 / 51 SF0516514 SF0526514 SF0524514 SF0548514 SF0516513 36 / 61 24 / 40 28 / 47 SF0526513 36 / 61 24 / 40 28 / 47 SF0524513 36 / 61 24 / 40 28 / 47 SF0548513 36 / 61 24 / 40 28 / 47 2650 / 3100 42 2650 / 3100 42 3050 42 3050 42 131 / 55 14 / -10 27,500 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 5.83 x 5.83 x 2.56 / 148 x 148 x 65 4.92 x 4.92 / 125 x 125 1.19 / .54 149 / 65 -4 / -20 50,000 SG0500404 SG0500403 SG0500504 SG0500503 10100060 10100064H TWR60 SH05GS35001, SH05GS61001, SH05SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 5 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan Performance Curve 35 41 .28 .24 SF 05 40 .20 SF 05 50 Hz 60 Hz IP 30 IP 54 .16 54 .12 4 P5 I 05 SG 20 2 10 0 10 20 50 30 40 Volume Flow (m³/hr.) 5 0 x SG 60 4 IP 5 .08 05 40 .20 SF SF 05 50 Hz 30 60 IP Hz 55 IP 10 0 0 .16 55 .12 5 P5 I 05 SG 20 .04 70 41 .28 .24 50 Static Pressure (Pa) Static Pressure (Pa) 50 35 60 Static Pressure (in. H2O) 60 0 TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70 2 0 10 20 50 30 40 Volume Flow (m³/hr.) 05 x SG Static Pressure (in. H2O) TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70 5 IP 5 60 .08 .04 70 0 ),/7(5)$1           %$&.9,(: (;+$867*5,//(   ; 6,'(9,(:     &87287    Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 6 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 0.23 20 230 50 / 60 0.11 20 24 — 0.17 4.1 48 — 0.08 3.5 SF0916414 SF0926414 SF0924414 SF0948414 SF0916413 75 / 127 59 / 100 67 / 114 SF0926413 75 / 127 59 / 100 67 / 114 SF0924413 75 / 127 59 / 100 67 / 114 SF0948413 75 / 127 59 / 100 67 / 114 SF0916514 SF0926514 SF0924514 SF0948514 SF0916513 70 / 118 54 / 92 62 / 106 SF0926513 70 / 118 54 / 92 62 / 106 SF0924513 70 / 118 54 / 92 62 / 106 SF0948513 70 / 118 54 / 92 62 / 106 2650 / 3100 51 2650 / 3100 51 3050 51 3050 51 131 / 55 14 / -10 27,500 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 8.03 x 8.03 x 3.54 / 204 x 204 x 90 6.97 x 6.97 / 177 x 177 1.74 / .79 149 / 65 -4 / -20 50,000 SG0900404 SG0900403 SG0900504 SG0900503 10100061 10100065H TWR60 SH09GS35001, SH09GS61001, SH09SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 7 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan Performance Curve ,3   20  6* [ 10 0 20 100 40 60 80 Volume Flow (m³/hr.)  3 , 120 .12  40  .20 +] ,3   .16 30 .08 20 .04 10 0 0 140  30 .16 6*   50  ,3 ] ,3   + +] .24 6)   .20 +] 60  40   .28    Static Pressure (Pa)  6)  50 Static Pressure (in. H2O) .24 6) ,3  60 0 70 .28  6) Static Pressure (Pa) 70 82 .32 71  6* [ 0 20 .12 40 100 60 80 Volume Flow (m³/hr.)  ,3 Static Pressure (in. H2O) 82 .32 ,3  71 TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80 6*  TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80 .08 .04 120 0 140 )LOWHU)DQ6)&)0 PuKU       %$&.9,(: (;+$867*5,//(         ;   &87287',0(16,216 6,'(9,(:    2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 8 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF10 162 CFM (275 m3/Hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 .53 / .50 43 / 40 230 50 / 60 .30 / .25 45 / 39 24 — 0.66 16 48 — 0.33 16 SF1016414 SF1026414 SF1024414 SF1048414 SF1016413 162 / 275 133 / 226 149 / 253 SF1026413 162 / 275 133 / 226 149 / 253 SF1024413 162 / 275 133 / 226 149 / 253 SF1048413 162 / 275 133 / 226 149 / 253 SF1016514 SF1026514 SF1024514 SF1048514 SF1016513 149 / 253 122 / 207 137 / 233 SF1026513 149 / 253 122 / 207 137 / 233 SF1024513 149 / 253 122 / 207 137 / 233 SF1048513 149 / 253 122 / 207 137 / 233 2760 / 3030 52 2760 / 3030 52 2950 52 2950 52 131 / 55 14 / -10 40,000 Terminal Block 131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 9.84 x 9.84 x 4.72 / 250 x 250 x 120 8.78 x 8.78 / 223 x 223 4.19 / 1.9 131 / 55 14 / -10 40,000 SG1000404 SG1000403 SG1000504 SG1000503 10100062 10100066H TWR60 SH10GS35001, SH10GS61001, SH10SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 9 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans SF10 162 CFM (275 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan 47 Volume Flow (CFM) 118 71 94 TYPE 12 / IP 55 Filter Fan 141 165 0 24 47 Volume Flow (CFM) 118 71 94 141 165 120 .48 120 .48 .40 100  ,3  ,3 + ]   +]   6) 80 .32 60 .24 40 .16  ,3 6* 20 .08 ,3 [6* 0 0 40 80 200 120 160 Volume Flow (m³/hr.) Static Pressure (Pa) .56 Static Pressure (in. H2O) 140  ,3 +]   ,3  +] 6)   6) .56 6) 140 100 Static Pressure (Pa) 24 80 60 .40 .32 .24 40 .16 2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ .08  240 0 280     (;+$867*5,//(  ,3 6* 20 ,3 [6* 0 0 40 80 200 120 160 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0 PuKU %$&.9,(: Static Pressure (in. H2O) 0 240 0 280       6,'(9,(:       ; &87287',0(16,216  Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 10 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 .58 / .70 64 / 80 230 50 / 60 .29 / .35 64 / 80 24 48 — — 2.60 1.30 55 55 Terminal Block 115 Rvrs 50 / 60 .58 / .70 64 / 80 230 Rvrs 50 / 60 .29 / .35 64 / 80 SF1316414 SF1326414 SF1324414 SF1348414 SF1316414R SF1326414R SF1316413 375 / 638 249 / 423 333 / 565 SF1326413 375 / 638 249 / 423 333 / 565 SF1324413 375 / 638 249 / 423 333 / 565 SF1348413 375 / 638 249 / 423 333 / 565 SF1316413R 375 / 638 249 / 423 333 / 565 SF1326413R 375 / 638 249 / 423 333 / 565 SF1316514 SF1326514 SF1324514 SF1348514 — — SF1316513 346 / 587 228 / 387 301 / 511 SF1326513 346 / 587 228 / 387 301 / 511 SF1324513 346 / 587 228 / 387 301 / 511 SF1348513 346 / 587 228 / 387 301 / 511 — — — — — — — — 2550 / 2800 60 2550 / 2800 60 2950 60 2950 60 2550 / 2800 60 2550 / 2800 60 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 140 / 60 140 / 60 -13 / -25 -13 / -25 40,000 40,000 12.72 x 12.72 x 5.83 / 323 x 323 x 148 11.5 x 11.5 / 292 x 292 7.5 / 3.4 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 11 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan 294 180 180 412 .72 160 .64 160 .64 140 .56 140 .56 .48 120 118 353 0 200 500 300 400 Volume Flow (m³/hr.) Static Pressure (Pa) 40 .08 20 .24 .16  0 100 200 .08  ,3 * [6 0 500 300 400 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0 PuKU 600 700                 ; 6,'(9,(: %$&.9,(: (;+$867*5,//(   * 6 0 700 .32   ,3 60 .16 0 600 80  3 3 *, [6 .40 ] , 20 100  3 ], 40 .48 +  .24 +   6)  ,3  6*  60 Static Pressure (in. H2O)   3  3 ], + ], +  .32  100 59 6)   .40 80 0 0  6) 6) 100 353 Volume Flow (CFM) 177 235 412 .72 120 Static Pressure (Pa) 59 TYPE 12 / IP 55 Filter Fan 294 Static Pressure (in. H2O) 0 Volume Flow (CFM) 118 177 235 &87287',0(16,216   2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\  Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 12 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 1.02 / 1.4 115 / 166 230 50 / 60 .51 / .74 115 / 175 Terminal Block 400 50 / 60 .22 /. 26 110 / 150 SF1316424 SF1326424 SF1340424 SF1316423 473 / 803 343 / 583 399 / 677 SF1326423 473 / 803 343 / 583 399 / 677 SF1340423 473 / 803 343 / 583 399 / 677 SF1316524 SF1326524 SF1340524 SF1316523 436 / 740 314 / 533 369 / 627 SF1326523 436 / 740 314 / 533 369 / 627 SF1340523 436 / 740 314 / 533 369 / 627 2450 / 2650 70 2550 / 2750 70 2650 / 2900 70 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162 11.50 x 11.50 / 292 x 292 7.72 / 3.5 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 13 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan TYPE 12 / IP 55 Filter Fan 59 118 177 235 294 353 Volume Flow (CFM) 412 471 530 589 0 59 118 177 235 294 353 412 471 530 589 225 .90 200 .80 200 .80 175 .70 175 .70 100 200 300 400 500 600 700 800  0  25 0  ,3  +] 50  ,3 .30 100 .40 75 .20 50 .10 25 0 900 1000 .50   ,3   6*  ,3  * [6  75 +] .40  100 125 .60    .50 150   ,3 +]  ,3 +]   ,3  * 6  6)     125 .60  6)  6) 150 Static Pressure (Pa) .90 Static Pressure (in. H2O) 225  6) Static Pressure (Pa) 0  ,3  6* [ .30 .20 .10 0 0 Volume Flow (m³/hr.) Static Pressure (in. H2O) Volume Flow (CFM) 100 200 300 400 500 600 700 800 0 900 1000 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0 PuKU     %$&.9,(: (;+$867*5,//(   5        6,'(9,(:     ; &87287',0(16,216  2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 14 Fresh Air Enclosure Cooling Filter Fans Performance Data  SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12/IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 Rvrs 50 / 60 1.05 / 1.5 120 / 175 230 Rvrs 50 / 60 .51 / .70 115 / 165 Terminal Block 400 Rvrs 50 / 60 .22 / .26 110 /1 50 SF1316424R SF1326424R SF1340424R SF1316423R 473 / 803 343 / 583 399 / 677 SF1326423R 473 / 803 343 / 583 399 / 677 SF1340423R 473 / 803 343 / 583 399 / 677 2450 / 2650 70 2550 / 2750 70 2650 / 2900 70 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162) 11.50 x 11.50 / 292 x 292) 7.72 / 3.5 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 15 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Performance Data  SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 1.02 / 1.47 115 / 175 230 50 / 60 .6 / .92 135 / 215 24 — 5.00 105 Terminal Block 48 — 2.60 105 400/460 50 / 60 .25 / .27 113 / 172 SF1316434 SF1326434 SF1324434 SF1348434 SF1346434 SF1316433 571 / 970 377 / 640 454 / 770 SF1326433 571 / 970 377 / 640 454 / 770 SF1324433 571 / 970 377 / 640 454 / 770 SF1348433 571 / 970 377 / 640 454 / 770 SF1346433 571 / 970 377 / 640 454 / 770 SF1316534 SF1326534 SF1324534 SF1348534 SF1346534 SF1316533 526 / 893 345 / 586 415 / 705 SF1326533 526 / 893 345 / 586 415 / 705 SF1324533 526 / 893 345 / 586 415 / 705 SF1348533 526 / 893 345 / 586 415 / 705 SF1346533 526 / 893 345 / 586 415 / 705 2600 / 2850 70 2650 / 2950 69 2750 70 2750 70 2650 / 3050 73 140 / 60 5 / -15 40,000 140 / 60 140 / 60 140 / 60 5 / -15 5 / -15 5 / -15 40,000 40,000 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6 140 / 60 5 / -15 40,000 SG1300404 SG1300403 SG1300504 SG1300503 1010063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 16 Fresh Air Enclosure Cooling Filter Fans SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan Performance Curve 200 .80 .70 175 .70 .60 .50 *  ,3   125 .40  [ 6 100 .30 75 50 25   ,3  * [6 0 0 100 200 300 400 500 600 700 800 150 125 .60 100 50 .10 25 .50 .40 75 .20 0 900 1000   ,3    ,3 ,3  471 ] ] ] +  + 177 +     ,3 Static Pressure (Pa) .80   6)  150 530 589 .90 +]   175 118   6) 6) 225   6) 200 59 ,3   225 0 Volume Flow (CFM) 235 294 353 412 530 589 .90  471  [ 6* 118 Static Pressure (Pa) 59 TYPE 12 / IP 55 Filter Fan Static Pressure (in. H2O) 0 Volume Flow (CFM) 177 235 294 353 412  6* [  ,3 .30 Static Pressure (in. H2O) TYPE 12 / IP 54 Filter Fan .20 .10 0 0 Volume Flow (m³/hr.) 100 200 300 400 500 600 700 800 0 900 1000 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0 PuKU       %$&.9,(: (;+$867*5,//( 2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\         6,'(9,(:     ; &87287',0(16,216  Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 17 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Performance Data  SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 1.02 / 1.47 115 / 175 230 50 / 60 .6 / .92 135 / 215 Terminal Block 400/460 50 / 60 .25 / .27 113 / 160 SF1316434R SF1326434R SF1340434R SF1316433R 571 / 970 377 / 640 454 / 770 SF1326433R 571 / 970 377 / 640 454 / 770 SF1346433R 571 / 970 377 / 640 454 / 770 2600 / 2850 70 2650 / 2950 69 2650 / 3050 73 140 / 60 5 / -15 40,000 140 / 60 5 / -15 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6 140 / 60 5 / -15 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 18 Fresh Air Enclosure Cooling Filter Fans ST THIN SIDE-MOUNT ST10 100 CFM (170 m3/hr.) INDUSTRY STANDARDS SPECIFICATIONS UL/cUL recognized; File no. 235470 CE, CSA (entire fan assembly excluding VDC and ST13 models) Type 12, IP54 standard Type 12, IP55 optional APPLICATION • • • • • • • • • • • • • • 19  ree airflow from 100 CFM (170 m 3 /hr.) to 303 CFM (515 m 3 /hr.) F S ervice life hours range from 40000 to 57500 Operating temperature range of -4 F / -20 C to 149 F / 65 C FINISH • • • • •  AL 7035 light-gray UV-resistant plastic standard R R AL 9011 black UV-resistant plastic optional Replacement filters T hermostat Rain shroud NOTES  T13 has reverse airflow option available to push/pull air through S higher static pressure Click-fit design quickly installs into enclosure wall; no tools or screws required T hin depth to minimize cabinet intrusion Enclosure side wall mounting Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers Terminal wire connections Simple snap-open grille for easy filter replacement Optional thermostat available to save energy and extend service life Cooling • • • ACCESSORIES Industrial automation Automotive assembly P ackage handling equipment Food and beverage process controls W ind energy systems FEATURES ST13 303 CFM (515 m3/hr.) Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Performance Data  ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 0.2 18 230 50 / 60 0.10 18 24 — 0.27 6.5 48 — 0.14 6.5 ST1016414 ST1026414 ST1024414 ST1048414 ST1016413 100 / 170 74 / 125 84 / 143 ST1026413 100 / 170 74 / 125 84 / 143 ST1024413 100 / 170 74 / 125 84 / 143 ST1048413 100 / 170 74 / 125 84 / 143 ST1016514 ST1026514 ST1024514 ST1048514 ST1016513 92 / 156 67 / 114 77 / 130 ST1026513 92 / 156 67 / 114 77 / 130 ST1024513 92 / 156 67 / 114 77 / 130 ST1048513 92 / 156 67 / 114 77 / 130 2750 / 3100 44 2750 / 3100 44 3150 46 3150 46 131 / 55 14 / -10 40,000 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 40,000 57,500 9.84 x 9.84 x 4.02 / 250 x 250 x 102 8.78 x 8.78 / 223 x 223 2.54 / 1.15 149 / 65 -4 / -20 57,500 SG1000404 SG1000403 SG1000504 SG1000503 10100062 10100066H TWR60 SH10GS35001, SH10GS61001, SH10SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 20 Fresh Air Enclosure Cooling Filter Fans ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan Performance Curve 74 88 70 60 67  Static Pressure (Pa) 50 67    40  +] ,3    ,3   30 103 .28 .24 60 .24 .20 50 .12 20  ,3  6* 10 .08 15 67  30     +] +] .16 ,3  ,3   .12  20 0 25 50 125 75 100 Volume Flow (m³/hr.) .04  0 175  ,3 [6* 0 0 150 .08 10 .04 0  ,3  6* ,3  [6* 88 .20  67 40 29 74 70 .16 +] 0 Volume Flow (CFM) 44 59 103 .28 Static Pressure (Pa) 15 Static Pressure (In. H2O) 0 Volume Flow (CFM) 44 29 59 Static Pressure (In. H2O) TYPE 12 / IP 55 Filter Fan TYPE 12 / IP 54 Filter Fan 25 50 125 75 100 Volume Flow (m³/hr.) 0 150 175 )LOWHU)DQ67&)0 PuKU           %$&.9,(: (;+$867*5,//(     6,'(9,(:   ; &87287',0(16,216    2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 21 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Performance Data  ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Shroud Catalog Number 115 50 / 60 .58 / .70 64 / 80 230 50 / 60 .29 / .35 64 / 80 ST1316414 ST1326414 ST1316414R ST1326414R ST1316413 303 / 515 209 / 355 249 / 422 ST1326413 303 / 515 209 / 355 249 / 422 ST1316413R 303 / 515 209 / 355 249 / 422 ST1326413R 303 / 515 209 / 355 249 / 422 ST1316514 ST1326514 ST1316514R ST1326514R ST1316513 277 / 470 191 / 325 219 / 372 ST1326513 277 / 470 191 / 325 219 / 372 ST1316513R 277 / 470 191 / 325 219 / 372 ST1326513R 277 / 470 191 / 325 219 / 372 2550 / 2800 60 2550 / 2800 60 2550 / 2800 60 2550 / 2800 60 131 / 55 14 / -10 40,000 115 50 / 60 .58 / .70 64 / 80 Terminal Block 131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 12.72 x 12.72 x 4.8 / 323 x 323 x 122 11.50 x 11.50 / 292 x 292 7.5 / 3.4 230 50 / 60 .29 / .35 64 / 80 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH13GS35001, SH13GS61001, SH13SS04001 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 22 Fresh Air Enclosure Cooling Filter Fans ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 140 .56 140 .56 .48 120 .48  * 60 6 40 200 300 500 400 .16  3 0 100 .24 , * 6 [ 20 0 .32   ,3 600 100 80 0 59 118 177 235 353 412 .64 .40   ,3 .32  * 6 60 40 .08 294 .16  6* [ .24  ,3 .08 20 0 700 Static Pressure (in. H2O) .40 Static Pressure (Pa) 353  3 ],  + 3  ],  + 67   67 Static Pressure (Pa) 235  3 ] , +    3 67 ], +   67 160 80 177 Volume Flow (CFM) 160 100 118 294 412 .64 120 59 Static Pressure (in. H2O) 0 0 0 0 Volume Flow (m³/hr.) 100 200 300 400 500 600 700 Volume Flow (m³/hr.) )LOWHU)DQ67&)0 PuKU           %$&.9,(: (;+$867*5,//( 6,'(9,(:       ; &87287',0(16,216    2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 23 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00740 I Fresh Air Enclosure Cooling Filter Fans Notes EQUIPMENT PROTECTION Spec-00740 I PH 763.422.2211 • FAX 763.576.3200 • pentairprotect.com Cooling 24