Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 L041608004 Report No: Report Prepared For: Model Number: Test: NVLAP LAB CODE 200927-0 GM LIGHTING 9830 W 190th St, Torrance, CA 90503 SLCB-18-27 Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is SLCB-18-27 . Received in working and undamaged condition. No modifications were necessary. Testing Condition: Total lumens and electrical values are generated from Light Laboratory Report L041608001 by using length ratio of 2.0. Spectral color data are from Light Laboratory Report L041608001. Sample Arrival Date: 4/25/16 Date of Tests: 4/28/16 Seasoning of Sample: - 4/29/16 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analyzer ITECH DC Power Supply Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer Model No Stock No Calibration Due Date 61604 WT210 2503AH IT6122 52k/J RMG-C-MKII 2MR97 SPR-3000 PS-AC02 MT-EL06-S1 MT-EL01 PSDC-03-S1 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2 -11/18/16 11/30/16 11/17/16 11/24/16 --Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4 Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W): NVLAP LAB CODE 200927-0 GM LIGHTING SLCB-18-27 N/A 366.04 120.00 0.07 8.07 0.99 15% N/A 45 95 2740 0.4540 0.4049 25.0 0:30 1:05 0.00 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4 Report No: L041608004 Date: 4/29/2016 Percent Output 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Spectral Power 1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength W/m2nm 380 390 400 410 420 430 0.0000 0.0000 0.0000 0.0000 0.0000 0.0001 CRI & CCT x 0.4540 y 0.4049 u' 0.2613 v' 0.5243 CRI 95.30 CCT 2740 Duv -0.00162 R Values R1 96.24 R2 99.10 R3 98.58 R4 95.45 R5 96.43 R6 97.19 R7 92.80 R8 86.53 R9 72.66 R10 97.33 R11 96.89 R12 87.54 R13 97.30 R14 99.49 430 440 450 460 470 480 490 500 480 0.0004 0.0010 0.0010 0.0007 0.0006 0.0008 0.0010 530 510 520 530 540 550 560 570 580 Wavelength(nm) 0.0011 0.0013 0.0014 0.0015 0.0016 0.0018 0.0020 580 590 600 610 620 630 640 630 680 0.0021 0.0023 0.0026 0.0028 0.0029 0.0029 0.0029 650 660 670 680 690 700 710 730 0.0027 0.0025 0.0021 0.0018 0.0015 0.0012 0.0009 780 720 730 740 750 760 770 780 0.0007 0.0006 0.0004 0.0003 0.0002 0.0002 0.0002 CIE 1931 Chromaticity Diagram Y 0.9 520 0.8 530 540 510 0.7 550 560 0.6 570 500 0.5 580 590 0.4 0.4540, 0.4049 0.3 600 610 620 630 640 650 700 490 0.2 480 0.1 470 460 0 0 0.1 440 430 380 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4 Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 10 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L041608004 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 4/29/2016 [MANUFAC] GM LIGHTING [LUMCAT] SLCB-18-27 [LUMINAIRE] 1"L. X 18"W. X 1"H. LED LINEAR LIGHT BAR [BALLASTCAT] N/A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [TEST CONDITION] CANDELA AND ELECTRICAL VALUES ARE GENERATED FROM LIGHT [MORE] LABORATORY REPORT L041608001 BY USING LENGTH RATIO OF 2.0. [INPUT] 120VAC, 8.08W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height N.A. (absolute) N.A. (absolute) 366 N.A. 45 8.08 1.00 Direct 1.26 1.20 1.34 Rectangular w/Sides 0.08 ft 1.50 ft 0.02 ft Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 8200 7458 6811 6373 6349 8113 7289 6458 5691 5265 8877 8052 7092 5700 2837 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0.0 120.82 120.32 118.48 115.62 111.92 107.22 101.52 95.14 88.26 80.88 73.16 64.78 56.88 49.34 42.28 35.58 29.36 23.82 18.96 14.60 11.08 8.40 6.20 4.54 3.52 2.68 2.02 1.68 1.52 1.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.5 120.82 120.06 118.22 115.20 111.60 106.56 100.76 94.22 87.18 79.80 71.58 63.18 55.38 47.58 40.10 33.48 27.44 21.90 17.04 12.92 9.56 6.96 5.12 3.78 2.68 2.18 1.68 1.52 1.18 1.18 1.00 0.00 0.00 0.00 0.00 0.00 0.00 45.0 120.82 120.16 117.88 115.04 110.58 105.22 98.68 91.88 84.08 75.94 67.46 59.06 50.68 42.62 34.90 27.86 21.56 16.02 11.50 8.06 5.46 3.78 2.68 2.02 1.52 1.18 1.18 1.00 1.00 0.76 0.68 0.00 0.00 0.00 0.00 0.00 0.00 67.5 120.82 119.98 117.64 114.52 109.74 103.78 96.74 89.18 80.80 72.40 63.34 54.38 45.64 37.00 28.70 20.80 13.92 8.22 4.36 2.26 1.26 0.92 0.68 0.58 0.68 0.68 0.58 0.50 0.42 0.42 0.42 0.00 0.00 0.00 0.00 0.00 0.00 90.0 120.82 120.16 117.64 114.10 109.42 103.54 95.98 87.94 79.54 70.98 61.42 52.52 43.46 34.40 25.34 17.28 9.56 3.18 0.00 0.00 0.00 0.00 0.00 0.16 0.16 0.16 0.34 0.34 0.34 0.34 0.34 0.00 0.00 0.00 0.00 0.00 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 43.80 92.25 149.61 260.93 331.73 348.36 336.97 105.81 164.42 153.27 70.80 28.85 16.63 12.86 15.09 16.34 17.60 17.67 4.81 366.04 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 12.00 25.20 40.90 71.30 90.60 95.20 92.10 28.90 44.90 41.90 19.30 7.90 4.50 3.50 4.10 4.50 4.80 4.80 1.30 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 11.40 32.40 48.45 57.36 58.61 52.71 41.95 28.85 16.63 8.55 4.31 2.22 1.25 0.79 0.48 0.07 0.00 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 118 118 118 118 106 101 96 92 96 88 80 74 88 77 68 62 80 68 59 52 74 61 52 45 68 55 46 39 63 50 41 34 59 45 37 31 55 42 33 28 52 38 30 25 115 115 115 115 103 98 94 90 93 85 79 73 85 75 67 61 78 66 58 51 71 59 51 44 66 53 45 39 61 49 40 34 57 44 36 31 53 41 33 27 50 38 30 25 108 108 108 93 90 86 81 75 71 71 64 59 63 56 50 57 49 43 51 44 38 47 39 34 43 35 30 39 32 27 36 29 25 103 103 103 88 86 83 77 72 68 68 62 57 60 54 49 54 48 42 49 42 37 45 38 33 41 34 30 38 31 27 35 29 24 98 84 73 65 58 52 47 43 39 36 34 95 77 64 53 45 39 34 30 27 24 22 98 82 69 60 52 46 41 37 34 31 28 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. 98 80 66 56 48 42 37 32 29 26 24 Page 5 IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES POLAR GRAPH 121 91 60 3 30 2 1 Maximum Candela = 120.82 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (90 - 270) # 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 6