Transcript
Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 L041608004
Report No:
Report Prepared For:
Model Number: Test:
NVLAP LAB CODE 200927-0
GM LIGHTING 9830 W 190th St, Torrance, CA 90503
SLCB-18-27
Electrical and Photometric tests
Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample:
Client submitted the sample. Catalog number is SLCB-18-27 . Received in working and undamaged condition. No modifications were necessary.
Testing Condition:
Total lumens and electrical values are generated from Light Laboratory Report L041608001 by using length ratio of 2.0. Spectral color data are from Light Laboratory Report L041608001.
Sample Arrival Date:
4/25/16
Date of Tests:
4/28/16
Seasoning of Sample:
-
4/29/16
No seasoning was performed in accordance with IESNA LM-79.
Equipment List
Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analyzer ITECH DC Power Supply Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer
Model No
Stock No
Calibration Due Date
61604 WT210 2503AH IT6122 52k/J RMG-C-MKII 2MR97 SPR-3000
PS-AC02 MT-EL06-S1 MT-EL01 PSDC-03-S1 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2
-11/18/16 11/30/16 11/17/16 11/24/16 --Before Use
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 1 of 4
Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W):
NVLAP LAB CODE 200927-0
GM LIGHTING SLCB-18-27 N/A 366.04 120.00 0.07 8.07 0.99 15% N/A 45 95 2740 0.4540 0.4049 25.0 0:30 1:05 0.00
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 2 of 4
Report No: L041608004 Date: 4/29/2016
Percent Output
8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
NVLAP LAB CODE 200927-0
Spectral Power
1.0 0.8 0.6 0.4 0.2 0.0 380
Wavelength
W/m2nm
380 390 400 410 420 430
0.0000 0.0000 0.0000 0.0000 0.0000 0.0001
CRI & CCT x 0.4540 y 0.4049 u' 0.2613 v' 0.5243 CRI 95.30 CCT 2740 Duv -0.00162 R Values R1 96.24 R2 99.10 R3 98.58 R4 95.45 R5 96.43 R6 97.19 R7 92.80 R8 86.53 R9 72.66 R10 97.33 R11 96.89 R12 87.54 R13 97.30 R14 99.49
430
440 450 460 470 480 490 500
480
0.0004 0.0010 0.0010 0.0007 0.0006 0.0008 0.0010
530
510 520 530 540 550 560 570
580 Wavelength(nm)
0.0011 0.0013 0.0014 0.0015 0.0016 0.0018 0.0020
580 590 600 610 620 630 640
630
680
0.0021 0.0023 0.0026 0.0028 0.0029 0.0029 0.0029
650 660 670 680 690 700 710
730
0.0027 0.0025 0.0021 0.0018 0.0015 0.0012 0.0009
780
720 730 740 750 760 770 780
0.0007 0.0006 0.0004 0.0003 0.0002 0.0002 0.0002
CIE 1931 Chromaticity Diagram
Y 0.9 520
0.8
530 540
510
0.7
550 560
0.6
570
500
0.5
580 590
0.4
0.4540, 0.4049
0.3
600 610 620 630 640 650 700
490
0.2 480
0.1 470 460
0 0
0.1
440 430 380
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
X
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 3 of 4
Report No: L041608004 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
NVLAP LAB CODE 200927-0
Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment.
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by :
Keyur Patel
Test Report Released by:
Test Report Reviewed by:
Jeff Ahn Engineering Manager
Steve Kang Quality Assurance
*Attached are photometric data reports. Total number of pages: 10
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 4 of 4
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L041608004 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 4/29/2016 [MANUFAC] GM LIGHTING [LUMCAT] SLCB-18-27 [LUMINAIRE] 1"L. X 18"W. X 1"H. LED LINEAR LIGHT BAR [BALLASTCAT] N/A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [TEST CONDITION] CANDELA AND ELECTRICAL VALUES ARE GENERATED FROM LIGHT [MORE] LABORATORY REPORT L041608001 BY USING LENGTH RATIO OF 2.0. [INPUT] 120VAC, 8.08W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height
N.A. (absolute) N.A. (absolute) 366 N.A. 45 8.08 1.00 Direct 1.26 1.20 1.34 Rectangular w/Sides 0.08 ft 1.50 ft 0.02 ft
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES LUMINANCE DATA (cd/sq.m) Angle In Degrees
Average 0-Deg
Average 45-Deg
Average 90-Deg
45 55 65 75 85
8200 7458 6811 6373 6349
8113 7289 6458 5691 5265
8877 8052 7092 5700 2837
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES CANDELA TABULATION
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180
0.0 120.82 120.32 118.48 115.62 111.92 107.22 101.52 95.14 88.26 80.88 73.16 64.78 56.88 49.34 42.28 35.58 29.36 23.82 18.96 14.60 11.08 8.40 6.20 4.54 3.52 2.68 2.02 1.68 1.52 1.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00
22.5 120.82 120.06 118.22 115.20 111.60 106.56 100.76 94.22 87.18 79.80 71.58 63.18 55.38 47.58 40.10 33.48 27.44 21.90 17.04 12.92 9.56 6.96 5.12 3.78 2.68 2.18 1.68 1.52 1.18 1.18 1.00 0.00 0.00 0.00 0.00 0.00 0.00
45.0 120.82 120.16 117.88 115.04 110.58 105.22 98.68 91.88 84.08 75.94 67.46 59.06 50.68 42.62 34.90 27.86 21.56 16.02 11.50 8.06 5.46 3.78 2.68 2.02 1.52 1.18 1.18 1.00 1.00 0.76 0.68 0.00 0.00 0.00 0.00 0.00 0.00
67.5 120.82 119.98 117.64 114.52 109.74 103.78 96.74 89.18 80.80 72.40 63.34 54.38 45.64 37.00 28.70 20.80 13.92 8.22 4.36 2.26 1.26 0.92 0.68 0.58 0.68 0.68 0.58 0.50 0.42 0.42 0.42 0.00 0.00 0.00 0.00 0.00 0.00
90.0 120.82 120.16 117.64 114.10 109.42 103.54 95.98 87.94 79.54 70.98 61.42 52.52 43.46 34.40 25.34 17.28 9.56 3.18 0.00 0.00 0.00 0.00 0.00 0.16 0.16 0.16 0.34 0.34 0.34 0.34 0.34 0.00 0.00 0.00 0.00 0.00 0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES ZONAL LUMEN SUMMARY Zone
Lumens
%Lamp
%Fixt
0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180
43.80 92.25 149.61 260.93 331.73 348.36 336.97 105.81 164.42 153.27 70.80 28.85 16.63 12.86 15.09 16.34 17.60 17.67 4.81 366.04
N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A.
12.00 25.20 40.90 71.30 90.60 95.20 92.10 28.90 44.90 41.90 19.30 7.90 4.50 3.50 4.10 4.50 4.80 4.80 1.30 100.00
Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone
Lumens
0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180
11.40 32.40 48.45 57.36 58.61 52.71 41.95 28.85 16.63 8.55 4.31 2.22 1.25 0.79 0.48 0.07 0.00 0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 4
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW
80 70 50 30 10
70 70 50 30 10
50 50 30 10
30 50 30 10
10 50 30 10
0 0
0 1 2 3 4 5 6 7 8 9 10
118 118 118 118 106 101 96 92 96 88 80 74 88 77 68 62 80 68 59 52 74 61 52 45 68 55 46 39 63 50 41 34 59 45 37 31 55 42 33 28 52 38 30 25
115 115 115 115 103 98 94 90 93 85 79 73 85 75 67 61 78 66 58 51 71 59 51 44 66 53 45 39 61 49 40 34 57 44 36 31 53 41 33 27 50 38 30 25
108 108 108 93 90 86 81 75 71 71 64 59 63 56 50 57 49 43 51 44 38 47 39 34 43 35 30 39 32 27 36 29 25
103 103 103 88 86 83 77 72 68 68 62 57 60 54 49 54 48 42 49 42 37 45 38 33 41 34 30 38 31 27 35 29 24
98 84 73 65 58 52 47 43 39 36 34
95 77 64 53 45 39 34 30 27 24 22
98 82 69 60 52 46 41 37 34 31 28
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
98 80 66 56 48 42 37 32 29 26 24
Page 5
IES INDOOR REPORT PHOTOMETRIC FILENAME : L041608004.IES POLAR GRAPH
121
91
60 3 30
2
1
Maximum Candela = 120.82 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (90 - 270) # 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 6