Lighting Laboratory, Inc. Color and Photometric Testing, According to IESNA LM‐79 Standards and Procedures, Test Report Files for:
HP, 18 Watt, Warm White, Dimmable, 140 Deg, Par 38 (SKU #180127)
Seesmart, Inc. – 4139 Guardian Street – Simi Valley, CA 93063 Tel: 877.578.2536 – Fax: 888.239.0959 – Web: www.seesmartled.com Copyright © 2012 Seesmart, Inc. All rights reserved.
Test #: L09121701 Date: 9/10/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
Test Report:
L09121701
Model Number:
180127
Report Prepared For:
Test:
NVLAP LAB CODE 200927‐0
SEESMART 4139 GUARDIAN ST SIMI VALLEY CA 93063
Electrical and Photometric tests as required by the IESNA test standards.
Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products
Description of Sample:
Client submitted the sample. Fixture catalog number is 180127. Received in working and undamaged condition. No modifications were necessary.
Sample Arrival Date:
9/4/12
Date of Tests:
9/6/12
‐
9/10/12
Seasoning of Sample SSL: No seasoning was performed in accordance with IESNA LM-79.
Equipment List
Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analysis System Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer
Model No
Stock No
Calibration Due Date
61604 WT210 2503AH 52k/J RMG-C-MKII 2MR97 SPR-3000
PS-AC02 MT-EL06-S1 MT-EL01 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2
-01/04/13 01/09/13 01/04/13 --Before Use
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 1 of 4
Test #: L09121701 Date: 9/10/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
NVLAP LAB CODE 200927‐0
LM-79 Test Summary SEESMART Manufacturer: 180127 Model Number: 969.56 Total Lumens: 120.00 Input Voltage (VAC): 0.18 Input Current (Amp): 16.66 Input Power (W): 0.78 Input Power Factor: Total Harmonic Distortion @ 120V(%):N/A Total Harmonic Distortion @ 277V(%):N/A 58.19 Efficacy: 68.52 Color Rendering Index (CRI): Correlated Color Temperature (CCT): 2693 0.4610 Chromaticity Coordinate x: 0.4117 Chromaticity Coordinate y: o 77.0 Ambient Temperature ( F): 1:00 Stabilization Time (Hours): 1:45 Total Operating Time (Hours):
FIG. 1 LUMINAIRE
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 2 of 4
Test #: L09121701 Date: 9/10/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
NVLAP LAB CODE 200927‐0
Spectral Power
Percent Output
1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength
W/m2nm
380 390 400 410 420 430
0.0001 0.0000 0.0000 0.0010 0.0059 0.0191
CRI & CCT x 0.4610 y 0.4117 u' 0.2627 v' 0.5279 CRI 68.52 CCT 2693 Duv 0.00033 0 00033 R Values R1 64.98 R2 78.03 R3 88.53 R4 63.32 R5 61.62 R6 66.24 R7 78.89 R8 46.52 R9 ‐22.64 R10 48.16 R11 53.18 R12 35.97 R13 66.36 R14 92.87
430
440 450 460 470 480 490 500
480
0.0383 0.0343 0.0146 0.0072 0.0049 0.0056 0.0103
530
510 520 530 540 550 560 570
580 Wavelength(nm)
0.0192 0.0295 0.0410 0.0526 0.0642 0.0747 0.0844
580 590 600 610 620 630 640
630
680
0.0911 0.0952 0.0945 0.0934 0.0878 0.0789 0.0688
650 660 670 680 690 700 710
730
0.0590 0.0494 0.0398 0.0320 0.0242 0.0193 0.0154
780
720 730 740 750 760 770 780
0.0112 0.0084 0.0074 0.0054 0.0030 0.0024 0.0018
CIE 1931 Chromaticity Diagram
Y 0.9 520
0.8
530 540
510
0.7
550 560
06 0.6
570
500
0.5
580 590
0.4
0.4610, 0.4117
0.3
600 610 620 630 640 650 700
490
0.2 480
0.1 470 460
440 430 380
0 0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
X
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 3 of 4
Test #: L09121701 Date: 9/10/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558
NVLAP LAB CODE 200927‐0
Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample.
Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment.
Test Report Released by:
Test Report Reviewed by:
Joseph Shin Engineering Manager
Steve Kang Quality Assurance
*Attached are photometric data reports. Total number of pages: 9
*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.
Page 4 of 4
IES INDOOR REPORT PHOTOMETRIC FILENAME : L09121701.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L09121701 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 09/10/2012 [MANUFAC] SEESMART [LUMCAT] 180127 [LUMINAIRE] 4-3/4"DIA. X 5-3/4"H. LED DIMMABLE PAR 38 BULB [MORE] ONE MODULE WITH NINE WARM WHITE LED WITH DIFFUSED LENS [LAMPPOSITION] 0,0 [LAMPCAT] WARM WHITE LED [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [_INPUT] 120VAC, 16.64W [_TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height
N.A. (absolute) N.A. (absolute) 970 N.A. 58 16.64 1.00 Direct 1.28 1.28 1.40 Circular w/ Sides 0.31 ft (Diameter) 0.31 ft (Diameter) 0.06 ft
LUMINANCE DATA (cd/sq.m) Angle In Degrees
Average 0-Deg
Average 45-Deg
Average 90-Deg
45 55 65 75 85
34047 30113 25740 21192 17218
34047 30113 25740 21192 17218
34047 30113 25740 21192 17218
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT PHOTOMETRIC FILENAME : L09121701.IES CANDELA TABULATION
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180
0 312.76 311.63 307.91 302.04 293.62 282.38 268.24 251.86 232.35 210.61 187.73 163.89 139.93 116.70 94.47 73.90 56.23 40.20 25.18 13.56 5.65 1.82 1.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT PHOTOMETRIC FILENAME : L09121701.IES ZONAL LUMEN SUMMARY Zone
Lumens
%Lamp
%Fixt
0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180
114.90 244.99 402.37 711.56 906.24 950.35 920.72 287.47 449.98 425.05 194.69 78.83 44.10 18.76 19.21 19.21 19.21 19.21 0.45 969.56
N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A.
11.90 25.30 41.50 73.40 93.50 98.00 95.00 29.60 46.40 43.80 20.10 8.10 4.50 1.90 2.00 2.00 2.00 2.00 0.00 100.00
Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone
Lumens
0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180
29.63 85.27 130.09 157.38 162.51 146.68 115.86 78.83 44.10 15.83 2.94 0.45 0.00 0.00 0.00 0.00 0.00 0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT PHOTOMETRIC FILENAME : L09121701.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW
80 70 50 30 10
70 70 50 30 10
50 50 30 10
30 50 30 10
10 50 30 10
0 0
0 1 2 3 4 5 6 7 8 9 10
119 119 119 119 107 102 97 93 97 88 81 75 88 77 68 62 81 68 59 52 74 61 52 45 68 55 46 39 63 50 41 34 59 45 37 31 55 41 33 27 52 38 30 25
116 116 116 116 104 99 95 91 94 86 79 74 85 75 67 61 78 67 58 52 72 60 51 44 66 54 45 39 61 49 40 34 57 44 36 30 54 41 33 27 50 38 30 25
110 110 110 94 91 88 82 76 72 72 65 60 64 56 51 57 50 44 52 44 38 47 39 34 43 35 30 39 32 27 36 29 25
105 105 105 90 87 85 78 74 70 69 63 58 61 55 50 55 48 43 50 43 38 45 38 33 41 35 30 38 32 27 35 29 24
100 100 100 86 84 82 75 71 68 66 61 57 59 53 49 53 47 42 48 42 37 44 38 33 40 34 29 37 31 27 34 28 24
98 79 65 55 46 40 35 31 28 25 22
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 4
IES INDOOR REPORT PHOTOMETRIC FILENAME : L09121701.IES POLAR GRAPH
313
235
156
2
78
1
Maximum Candela = 312.76 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.)