Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

ARCLITE 38/5 Spec Sheet ® recessed made-to-order PAR • 38 m ay metal not be H I D halide returned for 8-410 downlight credit • made-to-order • m ay not be returned for credit Features Arclite 38/5 is an efficient 5” aperture downlight designed for use with 70-watt, 100-watt or 150-watt PAR-38 metal halide lamps, and is equipped with an electronic ballast. Precise reflector design minimizes aperture brightness, with a shielding angle of 40°. PAR-38 metal halide lamps are available in a number of beam spreads from narrow spot to very wide flood. These lamps have color rendering indexes (CRI) of 70 to 93, and color temperatures ranging from 3000°K to 4000°K. The lamps have up to a 12,500-hour life. The 5” aperture matches that of our 5” Arclite accent lights, as well as our 5” PAR-38 incandescent downlights and accent lights. Reflector must be removed before relamping . Reflectors are available in clear, natural aluminum in two finishes: EvenTone, our standard clear finish, partially diffuse, anti-iridescent and gently luminous in appearance; and EasyTone, diffuse and luminous. Additionally, reflectors are available in champagne gold, wheat, pewter, bronze and black. Arclite 38/5 includes a pair of mounting bars (3/4” x 27” C channel). Specialty bars for wood joist and T-bar installations are also available. Requires ceiling opening of 5 15/16” (151mm) for Overlap or Flush Detail. Requires ceiling opening of 6 3/16” (157mm) for Trim Flush Detail. PRODUCT CODE For complete product code, list basic unit and select one item from each following box. Basic Unit..................................................................... ARC38/5 APPLICATIONS Wattage   70-watt ballast (no fixture spacing restrictions) ......................–70 100-watt ballast (see spacing restrictions *)...........................–100 150-watt ballast (see spacing restrictions *)...........................–150 Fixture is recommended for downlighting in stores, malls, banks, hotels, schools, auditoriums, airports and sports facilities – especially in lobbies, atria and other public areas. Fixture is listed for Damp Location and suitable for use in a fire rated ceiling. Fixture is prewired with electronic ballast and thermal protector, and is approved for eight #12 wire 75°C branch circuit pull-through wiring. Removal of the housing from below allows access to the ballast and junction box. Voltage 120 volt service ............... 120 277 volt service................ 277 Reflector Color and Detail Overlap Trim Flush* EvenTone Clear.................................... VOL.........................VTF EasyTone Clear................................... ECOL......................ECTF Champagne Gold................................ GOL....................... GTF Wheat.............................................. WHOL.................... WHTF Pewter................................................ POL......................... PTF Bronze................................................ ZOL.........................ZTF Black.................................................. BOL.........................BTF Other reflector finishes available on special order. Overlap Flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange). *Trim Flush reflector trim requires the use of a plaster ring Accessory (see below). Reflectors detailed for metal or wood ceilings available on special order. options Specify by adding to the end of basic unit. Fixtures for use with 100-watt or 150-watt lamps must be spaced at least 36” apart and 18” from walls, and must have ½” clearance above housing. Emergency: DC bayonet base socket only ............................... – EMA Auxiliary: DC bayonet base socket prewired to restrike relay;100 watt max lamp on 120 v service; 50 watt max on 277 v service .......– AUX MODIFICATIONS AVAILABLE accessories fixture spacing restrictions Plaster ring allows use of 5 7/8” OD Trim Flush (-TF) reflector in sheetrock ceiling; 6 3/16” dia hole required.......TF RING/5 Contact factory with quantity for pricing; orders may require shop drawing approval. CHP-: 39-watt fixture suitable for Chicago Plenum; add CHP- as prefix to Product Code. CONC-: 39-watt fixture suitable for poured-in-place concrete; add CONC- as prefix to Product Code. EXP-: `European-style´ install-from-below fixture; add EXP- as prefix to Product Code. +2”CLG: fixture suitable for installation in 2” thick ceiling material; add +2”CLG to Product Code. +DOD: fixture suitable for high humidity environments; add +DOD to Product Code. +MAR: reflector suitable for marine environments; add +MAR to Product Code. +TR: fixture prepared for top re-lamping; add +TR to Product Code. +OA MT: fixture prepared to accept an Optical Accessory holder; add +OA MT to Product Code. Specify as a separate line item. Decorative reflector rings are available on special order. Contact factory. 41-50 22ND STREET, L IC NY 11101 © Copyright, Edison Price Lighting 2015 tel 718.685.0700  fax 718.786.8530 www.epl.com Arclite is a registered trademark of Edison Price Lighting 10:15 ® arclite 38/5 PHOTOMETRIC REPORT – FLOOD BALLAST INFORMATION Voltage 120 277 Luminaire................ recessed metal halide with spun aluminum reflector, specular finish Lamp...................... MP100PAR38/U/FL35, 5500 lumens Efficiency...............69.8% Spacing Criterion..... 0.6 Input Watts 110 110 Maximum Current (A) .9 .41 Line Current (A) .9 .41 Power Factor (%) >90 >90 Min. Starting Temp (°F) –22 –22 ZONAL LUMEN SUMMARY LUMINANCE data Report No. 43160. Original Independent Testing Laboratories, Inc. (ITL) test report furnished upon request. Zone   0 – 30°   0 – 40°   0 – 60°   0 – 90° 90 –180°   0 – 180° Lumens % Lamp % Fixture 3682 3821 3840 3840 0 3840 66.9 69.5 69.8 69.8 0.0 69.8 95.9 99.5 100.0 100.0 0.0 100.0 CANDLEPOWER DISTRIBUTION Vertical Candela Angle Vertical Candela/m2 Angle 45 55 65 75 85 2018 0 0 0 0 0 5 15 25 35 45 55 65 75 85 90 9726 9452 7033 1922 196 19 0 0 0 0 0 To convert cd/m2 to footlamberts multiply by 0.2919. COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD (Effective Floor Cavity Reflectance 20%) Ceiling Reflectance (%) Wall Reflectance (%) 80 70 50 30 10 0 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 83 80 77 75 72 70 67 65 63 61 59 83 79 75 71 68 65 62 60 58 56 54 83 77 72 68 65 62 59 57 55 53 51 83 76 71 66 63 60 57 55 53 51 49 81 78 76 73 71 69 66 64 62 60 58 81 77 73 70 67 64 62 60 57 55 54 81 76 71 68 64 62 59 57 54 52 51 81 75 70 66 62 59 57 55 52 50 49 78 74 71 68 66 63 61 59 57 55 53 78 73 70 66 63 61 58 56 54 52 50 78 72 68 65 62 59 56 54 52 50 49 74 72 69 67 64 62 60 58 56 54 53 74 71 68 65 63 60 58 56 54 52 50 74 70 67 64 61 58 56 54 52 50 48 71 69 67 65 63 61 59 57 56 54 52 71 69 66 64 62 59 57 55 53 52 50 71 68 65 63 60 58 56 54 52 50 48 70 67 64 62 59 57 55 53 51 49 48 Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 PHOTOMETRIC REPORT – SPOT BALLAST INFORMATION Voltage 120 277 Luminaire................ recessed metal halide with spun aluminum reflector, specular finish Lamp...................... MP100PAR38/U/SP20, 5200 lumens Efficiency...............73.7% Spacing Criterion..... 0.4 Input Watts 110 110 Maximum Current (A) .9 .41 Line Current (A) .9 .41 Power Factor (%) >90 >90 Min. Starting Temp (°F) –22 –22 ZONAL LUMEN SUMMARY LUMINANCE data Report No. 43159. Original Independent Testing Laboratories, Inc. (ITL) test report furnished upon request. 90 90 90 90 90 90 Zone Lumens % Lamp % Fixture – 30° – 40° – 60° – 90° – 180° – 180° 3695 3815 3832 3832 0 3832 71.0 73.4 73.7 73.7 0.0 73.7 96.4 99.6 100.0 100.0 0.0 100.0 CANDLEPOWER DISTRIBUTION Vertical Candela Angle Vertical Candela/m2 Angle 45 55 65 75 85 2018 0 0 0 0 0 5 15 25 35 45 55 65 75 85 90 18397 17114 5368 1282 148 19 0 0 0 0 0 To convert cd/m2 to footlamberts multiply by 0.2919. COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD (Effective Floor Cavity Reflectance 20%) Ceiling Reflectance (%) Wall Reflectance (%) 80 70 50 30 10 0 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 88 85 82 80 77 75 73 71 69 68 66 88 83 80 76 74 71 69 67 65 63 61 88 82 78 74 71 68 66 64 62 60 59 88 81 76 72 69 66 64 62 60 58 57 86 83 81 78 76 74 72 70 69 67 66 86 82 78 75 73 70 68 66 64 63 61 86 81 77 73 70 68 66 64 62 60 58 86 80 75 71 68 66 64 62 60 58 57 82 79 76 74 71 69 67 65 64 62 61 82 78 75 72 69 67 65 63 61 60 58 82 77 73 70 68 65 63 61 60 58 57 78 76 74 72 70 68 66 65 63 62 60 78 75 73 70 68 66 64 63 61 59 58 78 75 72 69 67 65 63 61 59 58 56 75 74 72 70 69 67 66 64 63 61 60 75 73 71 69 67 66 64 62 61 59 58 75 73 70 68 66 64 62 61 59 58 56 74 71 69 67 65 63 62 60 58 57 56 Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10