Heater sizing table Dimplex provides a three tier service, to meet different property and timescale requirements. Level 3: For multiple properties, please send us comprehensive scale drawings (scale 1:50 or 1:100) together with construction details and any other relevant information. We offer a 14 working day service for this type of assessment.
Level 1: If you need to obtain an indication of the heating requirements for estimating or if you need heating for one or two rooms, please use the Selection Guide below. Level 2: For single properties, please complete the form on page 9 and post or fax it with a sketch plan to our heating design dept (0870 727 0118). We aim to provide an accurate assessment within 7 working days.
Levels 2 and 3 are provided on a free of charge basis. However should Dimplex products subsequently not be installed we reserve the right to charge for the scheme.
How to use this selection guide. The tables below are for use with Duoheat radiators only – for other products please refer to our selection charts on pg 8.
number of outside walls.The Duoheat model(s) you require will be shown where the two points meet.
Unlike the charts on page 8, these tables cover all applications - living room, dining room, kitchen and hallway - and are designed to provide for an internal temperature of 21ºC.
These tables do not take into account particularly old properties or those built very recently. If your property fits into one of these classifications, please complete the form on page 9 so that we can provide a more accurate assessment.
There are two tables to choose from - the first one is for insulated cavity walls and the second is for an uninsulated cavity wall. Simply look down the left hand column for the relevant floor area and then across the top row for the
Note:A ceiling height of 2.4m is assumed and a minimum of 75mm of roof insulation.
Living room/Dining room/Kitchen/Hallway Insulated Cavity Walls Number of outside walls
Floor area M2
1
2
3
12
Duo400i
Duo500i
Duo400i + Du300i
16
Duo500i
Duo300i + Duo300i
Duo400i + Duo400i
20
Duo400i + Duo300i
Duo400i + Duo300i
Duo500i + Duo400i
24
Duo400i + Duo400i
Duo400i + Duo400i
Duo500i + Duo400i
28
Duo400i + Duo400i
Duo500i + Duo400i
Duo500i + Duo500i
32
Duo500i + Duo400i
Duo500i + Duo400i
Duo500i + Duo500i
Uninsulated Cavity Walls Number of outside walls
Floor area M2
1
2
3
12
Duo300i + Duo300i
Duo400i + Duo300i
Duo500i + Duo400i
16
Duo400i + Duo300i
Duo400i + Duo400i
Duo500i + Duo500i
20
Duo400i + Duo400i
Duo500i + Duo400i
Duo400i + Duo400i + Duo400i
24
Duo500i + Duo400i
Duo500i + Duo500i
Duo500i + Duo400i + Duo400i
28
Duo500i + Duo500i
Duo400i + Duo400i + Duo400i
Duo500i + Duo500i + Duo400i
32
Duo500i + Duo500i
Duo500i + Duo400i + Duo400i
Duo500i + Duo500i + Duo500i