Product Specifications 810008756/DB    |    D-156 156--L2 L2--8W 8W--F12NS Double Jacket/Single Armor, Gel­Free, Outdoor Stranded Loose Tube Cable   l Corrugated steel tape armor is strong yet flexible, providing additional crush and  rodent protection   Representative Image       General Specifications Cable Type  Stranded loose tube  Construction Type  Armored  Subunit Type  Gel­free    Construction Materials Fiber Type Solution  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Jacket Material  PE  Total Fiber Count  156  Armor Type  Corrugated steel  Fiber Type  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Fiber Type, quantity  156  Fibers per Subunit, quantity  12  Jacket Color  Black  Jacket UV Resistance  UV stabilized    Dimensions Buffer Tube/Subunit Diameter  2.50 mm | 0.10 in  Cable Weight  206.0 lb/kft Diameter Over Jacket  20.60 mm Filler, quantity  5  Subunit, quantity  13  | | 306.0 kg/km  0.81 in    ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 1 of 3 May 3, 2016 Product Specifications 810008756/DB   |   D 810008756/DB   |   D--156 156--L2 L2--8W 8W--F12NS   Physical Specifications Minimum Bend Radius, loaded  30.8 cm | Minimum Bend Radius, unloaded  20.6 cm | 8.1 in  Tensile Load, long term, maximum  180 lbf | Tensile Load, short term, maximum  2700 N | Vertical Rise, maximum  12.1 in  800 N  607 lbf  267.0 m | 876.0 ft    Environmental Specifications Environmental Space  Aerial, lashed Installation Temperature  ­30 °C to +70 °C (­22 °F to +158 °F)  | Buried  Operating Temperature  ­40 °C to +70 °C (­40 °F to +158 °F)  Storage Temperature  ­40 °C to +75 °C (­40 °F to +167 °F)    Mechanical Test Specifications Compression  250 lb/in | 44 N/mm  Compression Test Method  FOTP­41 Flex  35 cycles  Flex Test Method  FOTP­104 Impact  4.88 ft lb | 6.62 N­m  Impact Test Method  FOTP­25 | IEC 60794­1 E4  Strain  See long and short term tensile loads  Strain Test Method  FOTP­33 Twist  10 cycles  Twist Test Method  FOTP­85 Water Penentration  24 h  Water Penentration Test Method  FOTP­82 | IEC 60794­1 E3  | IEC 60794­1 E6  | IEC 60794­1 E1  | IEC 60794­1 E7  | IEC 60794­1 F5    Environmental Test Specifications Cable Freeze  ­2 °C Cable Freeze Test Method  FOTP­98 | 28 °F  Heat Age  ­40 °C to +85 °C (­40 °F to +185 °F)  Heat Age Test Method  IEC 60794­1 F9  Low High Bend  ­30 °C to +60 °C (­22 °F to +140 °F)  Low High Bend Test Method  FOTP­37 Temperature Cycle  ­40 °C to +70 °C (­40 °F to +158 °F)  Temperature Cycle Test Method  FOTP­3 | | | IEC 60794­1 F15  IEC 60794­1 E11  IEC 60794­1 F1    Qualification Specifications Cable Qualification Standards  ANSI/ICEA S­87­640 | EN 187105 | Telcordia GR­20  Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008 Classification Compliant Designed, manufactured and/or distributed under this quality management system ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 2 of 3 May 3, 2016 Product Specifications 810008756/DB   |   D 810008756/DB   |   D--156 156--L2 L2--8W 8W--F12NS Included Products DB­8W­LT   (Product Component—not orderable)  — LightScope ZWP® Singlemode Fiber  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 3 of 3 May 3, 2016