Transcript

90 60 30 Blue Black Blue Purple Blue Brown 65 3 1 Black/White Yout 58 Compressor Contactor 12 Yellow 62 Red/White T1 T2 T3 46 12 35 Capacitor Black (High Spd) Outdoor Fan Motor (see chart) Black Yellow L1 L2 L3 Ground Lug 29 460V 230V Red C Phase Monitor Compressor Contactor COM High Pressure Control #1 NC C Defrost Control R Defrost CC Control LOR-1 L2 Lockout Relay L0 Control LI Low Pressure Control Defrost Sensor Y L B B W2 W2 Out. Fan Relay C SENSOR LOR-2 DFC-1 DFC-2 RV Reversing Valve Y1 C High Speed Solenoid NC AC SW G High Pressure Control #2 W3 7 Black 63 8 2 6 1 4 6 Pin Plug for Heater Package C 3 1 15 10 2 14 9 6 12 3 1 16 Pin Plug for Indoor Blower Motor Ladder Diagram Yellow 62 Fuses Fuse Block 61 Black JUMPER INSTALLED IF NO HEATER PACKAGE IS USED Wire Identification numbers Wires Connect 99 for Bard use only. if Option Not Used Factory Field Optional Red Transformer L3 Yo 24VAC 1 Black L2 Y R A Black L1 Disch. Line Tstat Yellow Brown 1 3 Outdoor Fan Relay Current Sensor Yellow DELAY ON BREAK 35 30 18 20 22 16 24 14 26 12 28 10 30 44 45 A AC Current Sensor 22 Low Ambient Control Outdoor Fan Motor Capacitor L3 Terminal Block 24 Red Red Blue Black Black/White Black/White Red/White Red (Low Spd) 40 W1 51 25 O1 Purple 20 B 5 Y1 15 L DH 40 10 Blue Y 24 VAC R E HPS Yellow Pink G W3 20 TB L1 L2 L Ground 230V Compressor Transformer Y Transformer 16 Red 18 CURRENT TRIP SETPOINT 480V 240V L2 M2 Low Ambient Control (Opt.) 1 2 3 4 7 8 9 W2 Low Voltage Term. Block NO NC COM 41 C COM 52 12 AWG WIRE 33 C C Red Black/Red Black 70 480V Black/White 20 High Speed Solenoid Pressure Transducer Red Black Crankcase Heater 14 9 Blue 22 Compressor T2 Black T3 R 53 Black/White NC 12 Yellow Red 59 60 42 6 Aux. Black Black/White C Black/White T1 C 10 L1 L2 L3 Red Hi Pressure Control #1 Y 54 38 Low Pressure Control 57 11 46 460V Crankcase Heater Aux. L1 L2 L3 A NC C 56 55 Phase Monitor Yellow T3 A 64 Out. Fan Relay Blue L3 A Hi Pressure Control #2 Discharge Line TStat Fuse Transformer L1 L2 L3 Orange Red/White Coil 30 Sensor 5 Pin Plug for Indoor Blower Motor 4 5 3 L1 T1 Compressor Contactor T2 L2 Terminal Block 67 17 Reversing Valve 4 Low Voltage Term. Block 20 Pink Brown Red/White Black Blue Red 17 Red/White Yellow Black/White Yellow/Red Yellow Yellow 39 Orange/Blk Brown Yellow Red/Yellow Red 23 3 Line 3 to power source or optional heater package C 1 Line 2 to power source or optional heater package CC 6 Black/White Y 2 460-60-3 Power Source 1 Red W2 C 4 Yellow R L1 5 Black L2 RV L 3 Red B 6 Pin Plug for Optional 34 Heater Package 5 Pin Plug 47 9 Line 1 to power source or optional heater package Black/White SENSOR R 14 Fuse Yellow LO Blue Blue 22 6 Red 59 2 15 10 12 Black NC 1 Black/White NO COM Indoor Blower Motor 16 Pin Plug 48 3 SEN JMP SPEEDUP 43 Note: Factory set on 60 min. cycle. Reconnect on 30 min. for 30 min. cycle or 90 min. for 90 min. cycle. Defrost Control Standard Diagram High Voltage Low Voltage ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4096-354 C