Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

- Chilled ceiling and radiator (CLC02) 2 lighting groups, on/off 2 lighting groups, dimmed 2 blinds, up/down • • • • • • • • • INT07 Heating with radiator and cooling with chilled ceiling Modulating heating and cooling valve Dew point monitoring On/off control of two lighting groups Dimming control of two lighting groups Control of two motorised window-blinds (up/down) Lighting and blinds operated with momentary-contact switches, or Lighting and blinds operated with flexible room unit via LON bus Option: Automatic lighting control based on occupancy and daylight level Plant diagram 70164 YC Room controller Room unit with temperature sensor D1 Window switch D2 Occupancy sensor D3 Dew point sensor D10, D11 Momentary-contact switches for 2 on/off lighting groups, D12…D15 Momentary-contact switches for 2 lighting groups, dimmed D16...D19 Momentary-contact switches for 2 blinds, up/down B1 Daylight sensor via LON bus YH Heating valve YC Cooling valve Q1, Q2 2 lighting groups, on/off Q3, Q4 2 lighting groups, dimmed Q5, Q6 2 motors for blinds D3 Q1, Q2 Q3, Q4 2x 2x Q5, Q6 2x N1 R1 B1 Lux D10, D11 2x YH D12...D15 4x T R1 D1 D2 D16...D19 4x N1 ( ) LON Operating diagram 70284 Y [%] Y TR SpH SpC H C YH YC Output signal Room temperature Effective heating setpoint Effective cooling setpoint Heating sequence Cooling sequence Heating valve Cooling valve Siemens Building Technologies Building Automation H C 100 YH YC SpH SpC 0 DESIGO RXC Applications library Application INT07 TR [°C] CA2A3825E07 / 07.2001 1/6 Functions A detailed description of the lighting and window-blind control functions will be found at the beginning of this section in document CA2A3825E00, “INT – Function description”. The HVAC functions are described in CA2A3815E00, " CLC – Function description". Function Brief description See CA2A3825E00 2 lighting groups, on/off 2 lighting groups, dimmed – – – – – Manual on/off operation with momentary-contact switches Manual on/off operation via LON bus Control signals Daylight sensor Dimming 3.2, 3.4 3.4, 3.6 3.6 3.6 3.3 2 blinds, up/down – – – – Manual operation with momentary-contact switches Manual operation via LON bus Control signals Blind control 4.2, 4.4 4.4, 4.6 4.6 4.3, 4.4 Compatible controllers INT07 requires the RXC30.1 basic controller, extension module RXC40.1 and extension module RXC41.1 Connection diagram D2 1) 2) LON 1)2) D3 D11) 2) YH 3) YC 3) D10 6) D11 6) D12 6) D13 6) D14 6) D15 6) R1 Lux B1 4 3 1 2 QAX... D16 6) D17 6) D18 6) D19 6) D4 GND 9 10 11 12 13 14 15 16 17 N N + – N L + – N L N3 M Q1 L N AC 230 V 4) Q2 4) L N AC 230 V CA2A3825E07 / 07.2001 2/6 Q3 L N AC 230 V 1) 2) 3) 4) 5) 6) PE 8 N Q44 D3 6 7 PE Q34 D2 GND D1 5 Q14 Q24 4 PE Y2+ Y2– PE 3 N2 N L N 2 N D4 N Q24 Y2+ 10 11 12 13 14 15 16 17 15 16 Y2– 9 PE 8 N 7 N1 L 1 RXC41.1 N 6 GND 5 D3 D2 GND 4 Q13 RXC30.1 3 Q14 D1 CLB CLA CLB CLA 2 PE 22 23 24 25 26 27 28 29 30 1 RXC40.1 N N 16 17 PE CP+ D4 CP– Q24 N GND D3 10 11 12 13 14 15 PE G 9 Q14 PE N 8 Y2 7 G 6 Q13 5 Q13 18 19 20 21 4 GND D2 N N D1 L L 3 GND 2 Y1 80311A 1 4) Q4 4) Q5 5) M Q6 5) L N AC 230 V Type of contact can be selected Only two of these devices may be connected (either to D1 or D2) Note the maximum simultaneous load on outputs Y1, Y2: Max. 6 VA (RXC30.1, data sheet 3840) Max. load per output: filament lamps: 2.5 kW, fluorescent lamps: 1.5 kVA Max. load per extension module: AC250 V, 3 A (limited with fine-wire fuse) Momentary-contact switches (without mechanical lock) DESIGO RXC Applications library Application INT07 Siemens Building Technologies Building Automation Momentary-contact switches Siemens Building Technologies Building Automation The table shows how the digital inputs for momentary-contact switches are assigned to the outputs. (The original assignments can be changed with the RXT10.1.) Switch Digital input Output Lighting group or window blind controlled D10 D3 (RXC30.1) Q14 (RXC30.1) Q1 D11 D4 (RXC30.1) Q24 (RXC30.1) Q2 D12 D1 (RXC40.1) Q14, Y1+ , Y1- Q3 Brighter D13 D2 (RXC40.1) (RXC40.1) Q3 Darker D14 D3 (RXC40.1) Q24, Y2+, Y2- Q4 Brighter D15 D4 (RXC40.1) (RXC40.1) Q4 Darker D16 D1 (RXC41.1) Q14 (RXC41.1) Q5 Up D17 D2 (RXC41.1) Q24 (RXC41.1) Q5 Down D18 D3 (RXC41.1) Q34 (RXC41.1) Q6 Up D19 D4 (RXC41.1) Q44 (RXC41.1) Q6 Down DESIGO RXC Applications library Application INT07 CA2A3825E07 / 07.2001 3/6 Device list Ref. Description Type N1 Room controller RXC30.1 3840 N2 Extension module for control of lighting RXC40.1 3842 N2 Extension module for control of blinds RXC41.1 3843 R1 Room unit (or flexible room unit via LON bus) QAX30.1 QAX31.1 QAX32.1 QAX34.1 QAX50.1 1741 1741 1641 1645 1648 Wireless room unit Receiver QAX90.1, 91.1 RXZ90.1 1643 1644 Daylight sensor via LON bus Third-party – Third-party – Third-party – B1 D1 D2 1) Type of contact can be selected 2) Only two of these devices may be connected (either to D1 or D2) 3) Note the maximum simultaneous load on outputs Y1, Y2: Max. 6 VA (RXC30.1, data sheet 3840) 4) Max. load per output: filament lamps: 2.5 kW, fluorescent lamps: 1.5 kVA 5) Max. load per extension module: AC250 V, 3 A (limited with fine-wire fuse) 6) Momentary-contact switches (without mechanical lock) Occupancy sensor 1) 2) 1) 2) . . . . D3 Dew point sensor Please provide AC24V supply! QFX21 D10, D11 Momentary-contact switches for on/off lighting 5) Third-party – D12...D15 Momentary-contact switches for dimmed lighting 6) Third-party – D16...D19 Momentary-contact switches for blinds, up/down 6) Third-party – YH Heating valve, thermic, on/off (PWM) control 3) STE71.1 STA71 4874 4877 . . . YC Cooling valve, thermic, on/off (PWM) control 3) T3W..., T4W... STE72 STE71.1 STA71 4829 4873 4874 4877 . . . Q1, Q2 Q3, Q4 Q5, Q6 CA2A3825E07 / 07.2001 4/6 Window switch 1) 2) Data sheet On/off lighting groups 4) Dimmed lighting groups Motors for blinds DESIGO RXC Applications library Application INT07 5) 4) 1551 Third-party – Third-party – Third-party – Siemens Building Technologies Building Automation Configuration Application INT07 incorporates the following parameters, set with the RXT10.1 commissioning and service tool (menu: Device, Configuration, Settings). See CA2A3815E02 (application CLC02) for notes on setting the parameters for the HVAC functions Menu Parameters Values and Range Default setting Lighting Automatic switch-on Building in use Enabled / Disabled Disabled Building not in use Enabled / Disabled Disabled Automatic switch-off Enabled / Disabled Enabled Off timer 0 ... 90 min 0 min Manual off disable Enabled / Disabled Disabled State after power-up On / Off / Last state Last state Mode Master / Slave Master Building in use 0 ... 100 % 0% Building not in use 0 ... 100 % 0% Off threshold (A) On/Off hysteresis (B) ... 2500 Lux 750 Lux On/Off hysteresis (B) 0 ... Off threshold (A) 100 Lux 100 % threshold (C) 0 ... Off threshold (A) 250 Lux Switch-on delay 0 ... 60 min 10 s Switch-off delay 0 ... 60 min 10 s Run time 5 s... 10 min 10 s Blind Slats With / Without With Step time 0.10 s ... 1.00 s 0.20 s Slat steps after closing 0 ... 5 steps 3 steps Minimum dim value Daylight Blinds LONMARK bindings Disable auto-open when closed Enabled / Disabled Disabled Close when building not in use Enabled / Disabled Enabled Close when room unoccupied Enabled / Disabled Disabled Mode Master / Slave Master . . . . . . See "LONMARK network variables " and "LONMARK binding templates" Ordering Room controllers may be ordered either with the application described above or with the appropriate basic application. Please state the quantity, DESIGO RXC device name, type code and application. Example 1 15 15 15 Notes • The controllers will be delivered with the basic settings shown above. • Minimum order quantity: 10 controllers Example 2 2 2 2 Notes • The controllers will be delivered with the basic application • The application can be loaded into the controllers by means of the RXT10.1 tool • Minimum order quantity: 1 controller Siemens Building Technologies Building Automation DESIGO RXC Applications library Application INT07 RXC30.1 room controllers with application INT07 Extension modules for lighting control Extension module for control of blinds RXC30.1 room controllers Extension modules for lighting control Extension module for control of blinds RXC30.1/INT07 RXC40.1 RXC41.1 RXC30.1 / 00030 RXC40.1 RXC41.1 CA2A3825E07 / 07.2001 5/6 . . . . . . . . . . . . . . . . . . . . . . . . . CA2A3825E07 / 07.2001 6/6 DESIGO RXC Applications library Application INT07 Siemens Building Technologies Building Automation