Transcript
SiteBoss 530 TM
MOST POPULAR DEVICE. HIGHLY FEATURED REMOTE MONITORING, ACCESS, AND CONTROL UNIT. The SiteBoss 530 is a versatile, mid-range system used for monitoring and control of remote equipment sites. The S530 provides remote monitoring of serial devices, equipment I/O, and environmental conditions at these remote sites and forwards notification when conditions fall outside limits. On-board I/O provides serial, Ethernet, and dialup connectivity. The S530-2 and -6 models provide two or six Expansion slots respectively to allow addition of various communications and monitoring I/O interfaces that might be desired for your specific site application.
HIGHLIGHTED FEATURES •• In-band or out-of-band access to remote serial equipment •• Out-of-band access to remote network equipment •• Base unit supports 2 serial and 2 Ethernet ports •• 2 or 6 additional slots provide flexible expansion options •• Supports up to 16 serial ports for remote serial device management •• Connect up to 16 remote EventSensor™ modules to add I/O ports (See the EventSensor section for more details) •• Supports up to 48 I/O points, contacts, voltage, 4-20mA, relays, and more •• Wireless cellular, ADSL, and/or dialup modem options •• Monitor up to 100 serial alarm messages •• Optional external MMC card temperature sensor •• Supports Asentria Setting Key functionality •• Easy to understand MIB works well with third-party SNMP Managers •• Compatible with ProVision ®, HP Openview ®, Spectrum ®, InterMapper ®, Nagios ®, SNMPc ®, Netcool ®, TrapServer ®, SitePortal™, NetBoss ®, and all other SNMP-based network management systems •• Send E-mail, SNMP trap, TCP/IP, or dial-out alarms •• Receive and convert SNMP traps into text alarms •• Access network devices via dialup PPP •• Fallback to dialup alarms if the Ethernet connection fails •• Web interface for easy configuration •• Optional internal run-time battery backup
SOLUTIONS SPOTLIGHT - MINNESOTA D.O.T. OVERVIEW For many years, Minnesota state agencies such as the State Police or the D.O.T. Operated their command and control structure over separate communications networks, often with little to no interoperability. The lack of a unified, scalable communications network that state agencies could use to coordinate their responses to emergencies was cited as a major target of reform by the Minnesota State Government.
THE CHALLENGE The challenge facing the lawmakers was one of funding the replacement of an antiquated patchwork of communication networks with a secure, voice network that could grow along with the state’s transportation system. With the Federal Communication Commission’s mandate that all entities utilizing “wide-band” VHF and UHF systems move to “narrow-band” systems by 2013, the Minnesota State Legislature responded by funding an 800MHz P25 Trunked Radio Communication System. The Office of Communications within MNDOT set out evaluating the state’s current systems and began design of the required additions to bring all state agencies together onto a common communications platform. Due to the high degree of importance placed on the reliability of an emergency communications network, one of the steps was to find a company with an established track record of delivering remote monitoring and control solutions to ensure that the network and its equipment would function properly.
THE SOLUTION Asentria was chosen to monitor two important items at the tower sites: environmental conditions (generators, smoke detectors, lights, building entries, AC & DC power) and the LAN/WAN backbone equipment. The remote site monitoring solution Asentria delivered to MNDOT included the SNMP-link SL-81 - and it’s successor, the SiteBoss 530. Featuring a Cisco router at each tower site for connectivity, Asentria’s remote site monitoring solution sends polling and alarm traffic via SNMP across the network to a central NOC. This is then fed into an in-house NMS system. The Asentria unit’s powerful control capabilities allow personnel to remotely send commands to enable or disable power plants and relay switches; change equipment configuration parameters; connect remote users to restricted ports; collect, buffer and securely transfer data, and more. In addition, Asentria solutions have not only helped make MNDOT’s network more reliable by enabling it to keep track of environmental conditions that could potentially pose a threat to its remote equipment, but have also proven to be highly flexible and customizable.
v4.2 - 5.20.14
SiteBoss 530 Specifications & Pricing TM
SLOT 1
SLOT 2
S530-2 Back Panel DESCRIPTION S530 with 2 Expansion Slots S530 with 6 Expansion Slots Extended Temperature Range 32MB Record Storage 64MB Record Storage On-board Dialup Modem On-board Temperature Sensor AC Supply for US 24VDC Power 48VDC Power Run-time Battery
CODE S530-2 S530-6 /XT**** /32M /64M /MD /T /ACUS** /24DC*** /DC*** /BB***
PRICE
Base unit and base options are separated with a slash ( / ), then Expansion slot options are listed, separated with a dash ( - ). The first Expansion card listed in the catalog number goes in slot 1, the next in slot 2, and so on. Thus all of the following are valid catalog numbers:
1) Remote Cabinet Monitoring and Remote Access - The S530 can be used in remote cabinets or enclosures, from small BTS locations up to large walk-in enclosures. This device supports remote environmental monitoring, power monitoring from both AC and DC sources, generator fuel levels, fuse panels, and monitoring of inherently non-SNMP type equipment such as HVAC, UPS, etc. The device also supports remote access to remote site equipment via Ethernet, POTS, or EDGE wireless modems. 2) Monitoring of Server Equipment Rooms - The S530 can be used in network equipment rooms primarily for environmental monitoring over larger areas or in specific cabinets within a room. Common environmental factors monitored are temperature, humidity, water, smoke, entry, motion, and airflow. The S530 can support power monitoring from both AC and DC sources. The S530 is specifically designed to notify an SNMP software, but other methods of notification are also possible.
DEVICE SPECIFICATIONS •• Unit Depth:7.80in/19.812cm •• Unit Height: 1.75in/4.445cm •• Unit Weight: 3-5lbs/1.36-2.27kg (dependent on configuration) •• Mounting: Shelf or 19in rack •• Power: 15VDC Desktop Supply (-48VDC optional) •• Voltage in: 36VDC(Min) / 60VDC(Max)
The S530 catalog number specifies the configuration and options you want to order with your S530 unit. The catalog number lists the options in the order shown below. Items with a * are truly optional and are omitted if not desired.
BASE UNIT + *EXTENDED TEMP + MEMORY SIZE + *MODEM + *TEMP SENSOR + POWER SUPPLY + *EXPANSION CARDS
IDEAL USES
•• Unit Width: 17.5in/44.45cm (S530-6) / 11in/27.9cm (S530-2)
BACK PANEL CONFIGURATION
•• Power Usage: 5.25W(Typical) /24W(Max) •• Operating temp.: 0 to 40°C standard, -40 to +60°C extended range •• Storage Temperature: -40° to 85° C •• Operating Humidity: 0 to 95% (Noncondensing) •• RoHS, CE, CSA/UL Certified
•• S530-2/32M/ACUS
•• S530-2/32/MD/T/ACUS-4S-ME
•• S530-2/32M/MD/ACUS
•• S530-6/XT/32M/ACUS-8V-8R-4S
•• S530-2/32M/MD/DC
•• S530-6/32M/ACEU-8C-8C-4C4V
•• S530-2/32M/MD/T/ACUS
•• S530-6/XT/32M/MD/T/ACUS-8V-8R
•• S530-2/32M/MD/ACUS/BB
BASE UNIT CONFIGURATION •• 2 RJ45 Serial I/O Ports
•• (1) ES/ESJ Port
•• 2 10/100 Ethernet Ports
•• 1 MMC Memory I/O Slot
•• 32MB Record Logging Database
•• AC Power Input
•• 2 or 6 Expansion Card Slots
ADDITIONAL PRODUCT DETAILS Unit comes with AC Desktop Power Supply with US-type IEC power cord, (1) 6ft Ethernet cable, (2) 6ft RJ45 serial cables, (1) RJ45-DB9F DCE Adapter, (1) RJ45DB9M DTE Adapter, (1) DB9 M/F Null Modem Adapter, (2) 19” rack mount ears, and a Documentation and Utilities CD. Expansion cards come with appropriate accessories. For example the 4X serial cards come with (4) 6ft RJ45 serial cables and (4) RJ45-DB9M DTE Adapters. The wireless modem cards come with an antenna. Contact Sales for more information.
ADDITIONAL PRICING DETAILS
** For International usage you can specify /ACUK, /ACEU, or /ACAU for UK, European, or Australian power cords respectively. *** When determining your S530 configuration, you may choose either DC Power or Run-time Battery, but not both. **** Standard operating temperature is 0 to +40°C. /XT option extends operating temperature to -40 to +60°C. Extended-temperature AC power supply included when ordering /AC with /XT option.
•• Mean Hours Between Failure: 70,000
SLOT 5
SLOT 3
SLOT 6
SLOT 4
SLOT 2
SLOT 1
S530-6 Back Panel v4.2 - 5.20.14