Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Prices as of October 21, 2015. Check Web site for most current prices. Dual Element Time-Delay Class J Fuses Company Information Terminal Blocks Specifications EDISON JDL Class J fuses are among the most popular current limiting time-delay fuses available. Their small physical size and high performance characteristics make Class J fuses ideal for any space-limited application. JDL5 JDL40 ZIPLink Connection System Interrupting Rating: 200,000 RMS Symmetrical Amps Multi-wire Connectors Self-Certified Interruptin Rating: 300,000 RMS Symmetrical Amps Sensor Cables and Connectors Self-Certified DC Ratings: Voltage Rating: JDL - 300 VDC Interrupting Rating: JDL - 20,000 Amperes DC M12 Junction Blocks Panel Interface Connectors Current Limiting: Class J Fuse Wiring Duct Cable Ties Agency Approvals Wire • UL Listed, Class J, Guide JDDZ, File E162363 • CSA Certified HRCI-J per C22.2, No. 248.8 Applications • Recommended for Type 2 (no damage) protection of IEC style motor starters and contactors. • Use to protect lower interrupting rated circuit breakers. • All general purpose circuits with inductive (high inrush) loads, including motor and motor branch circuits, and transformer circuits. Also suitable for lighting loads. Bulk Multi-conductor Cables Wire Management Products CROSS REFERENCE AJT LITTELFUSE LPJ MERSEN GOULD BUSSMANN EDISON VOLTS 600 JDL Power Supplies DC Converters Transformers and Filters JTD URRENT LIMITING JDL Dimensions inches (mm) DIMENSIONS Cat No. JFL and JDL, Class J Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control 110-200 225-400 450-600 Blade Width F – – 3/4 1-1/8 1-5/8 2 Mounting Hole Spacing G H J – – – – – – 1/2 3-518 3/8 11/16 4-3/8 3/8 15/16 5-1/4 17/32 1 6 11/16 JDL Series Dimensions - Inches [mm] A B 2.25 0.81 [57.15] [20.6] 2.38 1.06 [60.5] [26.92] 4.63 1.13 [117.5] [28.6] 5.75 1.63 [146.1] [41.3] 7.13 2.13 [181] [54] 8 2.5 [203.2] [63.5] Safety: Electrical Components K – – 9/32 9/32 13/32 17/32 Blade Width 70-100 Blade Thickness E – – 1/8 3/16 1/4 3/8 Blade Thickness 35-60 Barrel Length D – – 2-5/8 3 3-3/8 3-314 C D E F G H J K – – – – – – – – Barrel Length 1-30 Blade Length C – – 1 1-3/8 1-7/8 2-1/8 Blade Length Range Max. Dia. B 13/16 1-1/16 1-1/18 1-5/8 2-1/8 2-5/8 Max. Dia. Overall Length A 2-1/4 2-3/8 4-5/8 5-3/4 7-1/8 8 Overall Length Ampere Rating Range 1-30 35-60 70-100 110-200 225-400 450-600 Ampere Rating Rated Part AMP Voltage Pcs/ Package Price Number Rating Pkg Weight AC Max 1 $124.00 JDL1 2 $124.00 JDL2 3 $124.00 JDL3 4 $130.00 JDL4 5 $124.00 JDL5 6 $124.00 JDL6 8 $130.00 JDL8 1.00 lb. $124.00 JDL10 10 $130.00 JDL12 12 $124.00 10 JDL15 15 $130.00 JDL17-5 17.5 $124.00 JDL20 20 $124.00 JDL25 25 $124.00 JDL30 30 $219.00 JDL35 35 $219.00 JDL40 40 $219.00 JDL45 45 2.00 lb $219.00 JDL50 50 600V 60 $219.00 JDL60 70 $219.00 JDL70 $219.00 JDL80 80 5 1.70 lb $235.00 JDL90 90 $219.00 JDL100 100 $92.00 JDL110 110 $87.00 JDL125 125 $92.00 4.25 lb JDL150 150 $93.00 JDL175 175 $87.00 JDL200 200 $156.00 JDL225 225 $146.00 1 JDL250 250 1.70 lb $183.00 JDL300 300 $159.00 JDL350 350 $146.00 JDL400 400 $243.00 JDL450 450 $243.00 2.80 lb JDL500 500 600 $243.00 JDL600 Ampere Rating: 1–600 Amps • Space saving dimensions compared to Class R • Dual-Element construction provides superior time-delay to pass harmless motor or transformer surges • High performance with fatiguefree cycling capabilities • Extremely current limiting JDL Series Dual-element Time-delay Fuses Wiring Accessories Voltage Rating: JDL - 600 VAC JDL Features JDL150 Power Distribution Blocks Mounting Hole Spacing – – – – – – – – 1 [25.4] 1.38 [34.9] 1.88 [47.8] 2.13 [54] 2.63 [66.7] 3 [76.2] 3.38 [85.8] 3..75 [95.3] 0.13 [3.2] 0.19 [4.8] 0.25 [6.35] 0.38 [9.5] 0.75 [19.1] 1.13 [28.6] 1.63 [41.3] 2 [50.8] 0.5 [12.7] 0.69 [17.5] 0.94 [23.8] 1 [25.4] 3.63 [92.1] 4.38 [111.1] 5.25 [133.4] 6 [152.4] 0.38 [9.5] 0.38 [9.5] 0.56 [14.3] 0.75 [19.1] 0.28 [7.1] 0.28 [7.1] 0.41 [10.3] 0.53 [13.5] Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-145 Safety: Protective Wear Terms and Conditions Prices as of October 21, 2015. Check Web site for most current prices. Dual Element Time-Delay Class J Fuses Current Curves 600A Ampere Rating 200 40,000 30,000 100 80 60 10 7 6 3 20,000 10,000 8,000 6,000 AMPERE RATING 60, 000 80, 000 100, 000 100 30, 000 40, 000 .1 .08 .06 20, 000 200 100 .2 400 300 6, 000 8, 000 10, 000 .4 .3 3, 000 4, 000 1 .8 .6 1,000 800 600 2, 000 2 A 2,000 600 800 1, 000 4 3 4,000 3,000 300 400 10 8 6 1 200 20 200, 000 40 30 TIME IN SECONDS B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 400A 200A 225A 125A 100A 15A 20A 30A 40A 50A 60A 300 10A Cat. No. JDL (Amp) 600V 5A Cat. No. JDL (Amp) 600V 3A PEAK LET-THROUGH CURRENT CURVES 1A AVERAGE TIME/CURRENT CURVE RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS) .04 .03 4,000 3,000 AMPERE RATING 2,000 1,000 800 600 400 300 A 200, 000 60, 000 80, 000 100, 000 30, 000 40, 000 20, 000 6, 000 8, 000 10, 000 3, 000 4, 000 100 2, 000 200 600 800 1, 000 400A 600A — —± — — 4,400 — 5,540 8,000 6,420 9,000 7,000 10,000 7,500 11,100 8,000 11,800 8,330 12,500 9,000 13,270 9,380 13,820 10,000 15,000 11,270 16,000 12,180 17,270 14,360 19,270 15,820 20,600 100 60 50 40 30 20 15 10,000 8,000 6,000 300 400 1,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 Let-Thru Current (Apparent RMS Symmetrical) JDL (600V) Fuse Ratings 15A 30A 60A 100A 200A 270 470 750 — — 370 670 1,130 1,640 2,360 450 800 1,420 1,910 2,760 550 1,000 1,730 2,450 3,520 625 1,220 1,890 2,850 4,000 700 1,330 2,120 3,090 4,400 750 1,440 2,250 3,400 5,000 800 1,530 2,370 3,650 5,140 820 1,600 2,580 3,780 5,430 900 1,640 2,670 4,000 5,640 925 1,760 2,790 4,470 6,000 1,000 1,850 3,000 4,670 6,420 1,160 2,000 3,220 5,000 7,400 1,220 2,150 3,520 5,360 7,950 1,400 2,460 4,000 6,170 9,000 1,560 2,640 4,450 7,000 10,000 200 20,000 200 *Prosp. S.C.C. 600 400 40,000 30,000 100 Current-Limiting Effects B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 3,000 4,000 6,000 8,000 10,000 RMS SYMMETRICAL CURRENT IN AMPERES 2,000 600 800 1,000 300 400 200 60 80 100 30 40 20 6 8 10 2 1 .01 3 4 .02 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *RMS Symmetrical Amperes Short-Circuit Current. NOTE:Data derived from Current Limiting Curves. Book 3 (14.3) eCP-146 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Selection Guide Line Overview Company Information Terminal Blocks The fuse selection guide below is a general summary of the specifications included for each fuse type. This selection guide does not include the many variables that can exist for specific situations such as local codes, unusual temperature, or other operating conditions. When selecting fuses, be sure to comply with any applicable PUBLIC SAFETY standards that apply to Overcurrent Protection Devices (OPD). The Edison family of fuses, fuse blocks and fuse holders is divided into two classes: 1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T 2. General Purpose: Class M Midget and Small Dimension Edison Fuses Selection Guide and General Specifications Description Class J Fuse Type Fast-Acting Time-Delay Part Number JHL JDL Voltage Rating Amp Rating Interrupting Rating Current Limiting Agency Approvals Dimensions 600VAC 450VDC Current Limiting Class RK1 Class T Class RK5 Time-Delay ECNR ECSR LENRK LESRK TJN 250VAC 250VAC VDC* 125VDC* 600VAC 125 600VAC 600VAC 300VAC (1-200A) 300VDC* (10-60A) 300VDC* 160 VDC 300VDC* 250VDC* 250VDC* (15-600A) (201-600A) (70-600A) 1 - 600 1 - 600 3 - 600 10 - 600 5 - 600 Class CC Fast-Acting Fast-Acting TJS LCU HCLR 600VAC 600V 600VAC 300VDC (15-20A) 1 - 600 601 - 1200 Time-Delay HCTR 0.5 - 30 EDCC 600VAC 600VAC 300VDC (0.5-2.25A) (20–30A) 0.25 - 30 0.5 - 30 Class RK5 Class RK1 Class T Class L * Self-certified DC ratings Edison Fuses Selection Guide and General Specifications General Purpose – Midget Fuse Type Fast-Acting Part Number Voltage Rating MCL MOL Time-Delay MEQ MEN 250 VAC to 30A) 600 VAC 250 VAC 500 VAC 250 VAC (0.5 125VDC: (0.5 to 30A) Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30 Interrupting 100,000 10,000 RMS Amps RMS Amps Rating Current N/A Limiting Agency Approvals ABC UL Listed to 248.14, File E162443 CSA Cert. C22.2 Part 59.2, LR 700489 0.5 to 30 Fast-Acting Glass AGC GMA 250VAC: 250VAC (0.1 to 10A) (0.063 - 3A) 32VAC: 125VAC (15 to 30A) (4 - 15A) 0.10 to 30 0.063 to 15 Medium Time- Time-Delay Time-Delay Fast-Acting Delay Glass Ceramic Glass Glass S500 TimeDelay Glass GMC MDA MDL S506 250VAC (0.5 - 3A) 125VAC (4 - 10A) 250VAC 125VDC (20A) 250VAC: (0.0625 to 8A) 32VAC: (10 to 20A) 250VAC 250VAC 0.5 to 10 0.5 to 20 0.0625 to 20 0.032 to 10 0.25 to 6.3 See specifications table on product pages UL Listed standard 248-14 UL Listed Guide and File nos. Designed to UL/CSA 248-14 (ABC 0.25-20 A): UL Listed, Guide JDYX, File (AGC 1/100-10 A) E19180 63mA-6A JDYX and E19180 UL Recognition Guide and UL Recognition, Guide JDYX2, File nos. (ABC 20-30A):(AGC File E19180, 7A-15A 11-30) CSA Certified, File JDYX2 and E19180 053787_C_000, CSA Certification Record No: 63mA-6A Class 1422-01 053787 C 000 and Class No: 1422 01 and 1422 30 0.197” x 0.788” (5mm x 20mm) UL Listed standard 248-14 UL Listed Card: MDA 2/10-20A , MDL 1/16-8A (Guide JDYX, File E19180 UL Recognized Card: MDA 25-30A MDL 9-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15A (Class No. 1422-01)  L Recognized Guide U JDYX2, File E19180 Semko Approval VDE Approval BSI Approval IMQ Approval RoHS compliant 1/4” x 1-1/4”, (6.3mm x 32mm) 0.197” x 0.788” (5mm x 20mm) Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Wiring Duct Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Tools Test Equipment Enclosures Safety: Electrical Components Safety: Protective Wear Terms and Conditions N/A 1/4” x 1-1/4”, (6.3mm x 32mm) Panel Interface Connectors Enclosure Climate Control RoHS Dimensions ferrule (in): 13/32 length (in): 1-1/2 M12 Junction Blocks Circuit Protection General Purpose – Small Dimension Electronic Fast-Acting Ceramic Sensor Cables and Connectors Wire Class CC UL Listed Class J UL Listed Guide JDDZ Class J UL Listed, File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ, UL Listed, Class T, Std. 248-10 UL Listed to 248.4, Class CC, CSA Certified File E162363 File E162363 Guide JDDZ, File E162363 CSA Certified, Guide JDDZ, File E162363, HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per HRC-L C22.2 certified HRCI-MISC per C22.2 C22.2, HRCI-J per File 700489 C22.2, No. 248.12, File 53787, No. 248.10, CSA No. 248.8 C22.2, No. (LENRK CSA File 053787) Class 1422-02 & 1422-82 Class 1422-02, No. 248.4, File 700489 File 700489 248.8 File 53787 RoHS File 700489 compliant See product specification pages. ferrule (in): 13/32, length (in): 1-1/2 Description ZIPLink Connection System Cable Ties 200,000 RMS Symmetrical Amps Class J Wiring Accessories Multi-wire Connectors Class L Extremely Fast-Acting Power Distribution Blocks Circuit Protection eCP-143 Prices as of October 21, 2015. Check Web site for most current prices. Fuse Blocks for Class J Fuses Description Specifications For use with Edison JDL class J fuses Construction: T hermoplastic, UL Flammability; 94V-0 Terminal type: • C = Box lug type • CR = Box lug type, with retaining clip • P = Pressure plate. Clip reinforcin springs are standard on fuseblocks rated 100A and above. Voltage Ratings: 600 Volts AC Ampere Ratings: 0.50 - 600 Amps Short-circuit current Rating: 200,000 RMS Symmetrical Amps Agency Approvals • UL Listed, UL 512, Guide IZLT, File E14853 • CSA, certified, C22.2 No. 39, Class 6225-01, File 47235 J60060-1C Class J Fuse Blocks Part Number J60030-1P J60030-2P J60030-3P J60060-1C J60060-2C J60060-3C J60100-1CR J60100-3CR J60200-1CR J60200-3CR J60400-1CR J60400-3CR J60600-1CR J60600-3CR* J60030-2P Amps Poles Maximum Wire Size 1 0.5 to 30 31 to 60 61 to 100 101 to 200 201 to 400 401 to 600 2 #10-14 Cu Wt. Fig # Pcs/ Pkg (lbs.) Price 1 0.44 $18.50 2 0.35 $32.00 3 3 0.45 $48.50 1 1 0.44 $20.50 $39.00 2 2 0.35 3 3 0.55 $50.00 1 4 0.98 $34.50 3 1 3 1 3 1 3 #2-14 Cu-Al 1/0-8 Cu-Al 250MCM-6 Cu-Al 500MCM-4 Cu-Al 5 1 6 1.55 $89.00 1.70 $133.00 9 6.70 $396.00 7 3.10 $202.00 10 14.0 $568.00 (2) 500MCM-4/0 8 Cu-Al 11 5.40 $328.00 8.0 $969.00 * Not UL, Please use (3) J60600-1CR to assemble a 3 pole UL Fuseblock Class J Fuseholder Dimensions J60030-3P 0.5 Amp to 60 Amp 2.42 [61.3] 1.70 [43.2] .75 [19.1] 3.20 [81.3] 2.25 [57.2] 4.70 [119.4] 2.28 [58] .30 [7.62] 2.25 [57.2] .75 [19.1] C L CL 4.01 [102] 6.28" [160 1.50 [38.1] Figure 1 Figure 2 Figure 3 Note: All dimensions shown in inches [mm] Book 3 (14.3) eCP-196 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Fuse Blocks for Class J Fuses Terminal Blocks 0 3] 2] Company Information 4.70 .75 [19.1] 2.28 [58] .30 [7.62] 61 Amp[119.4] to 100 Amp 2.25 [57.2] [49.4] .94 [23.8] [38.1] 1.58 [40.1] Power Distribution Blocks 5 [127] Wiring Accessories [5.6] [12.7] C L CL 4.01 [102] 6.28" .22 [5.6] Dia. .5 [12.7] C'Bore ZIPLink Connection System [160] Multi-wire Connectors 3.14 [79.8] 1.50 [38.1] 1.75 [44.5] 101 Amp to 200 Amp 3.1 [78.7] 3 [76.2] 2 [50.8] 3.06 [77.7] Figure 4 .5 [12.7] 6.13 [155.7] Wiring Duct 3 [76.2] 1.75 [44.5] 3.5 [88.9] 7.5 [191] Cable Ties .344 [8.74] dia. hole through .750 [19.1] dia. c'bore Wire Bulk Multi-conductor Cables 4 [101.6] 1 [25.4] .625 [15.9] Power Supplies 10.51 [267] 9.00 [228] 6.00 [152.4] .56 [14.2] Wire Management Products .750 [19.1] Figure 7 Figure 6 201 Amp to 400 Amp Panel Interface Connectors 3.15 [80] 6.13 [155.7] 1.69 [42.9] .34 [8.6] dia. M12 Junction Blocks Figure 5 8.31 [211.1] 7.00 [177.8] .75 [19.1] .31 [7.8] .75 [19.1] c'bore Sensor Cables and Connectors 1.5 [38.1] DC Converters 4.00 [101.6] Transformers and Filters Circuit Protection 7.50 [191] .75 [19.1] c'bore .34 [8.6] dia. Tools .344 [8.7] dia. hole through .750 [19.1] dia. c'bore 2.0 [50.8] .5 [12.7] .50 [12.7] Test Equipment Enclosures Enclosure Climate Control Figure 9 Figure 8 1.00 [25.4] Safety: Electrical Components 401 Amp to 600 Amp 4 [101.6] 1.75 [44.5] Safety: Protective Wear 4.99 [126.7] 1.125 [28.6] 14.144 [359.3] 11.00 [279.4] 1 [25.4] .56 [14.2] Terms and Conditions 4.99 [126.7] 3.25 [82.6] 8.875 [225.4] 2.38 [60.5] .75 [19.1] c'bore .34 [8.6] dia. Figure 10 8.88 [226] 2.88 [73.2] Note: All dimensions shown in inches [mm] .344 [8.7] dia. hole through .750 [19.1] dia. c'bore Figure 11 .50 [12.7] 1.00 [25.4] Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-197 Prices as of October 21, 2015. Check Web site for most current prices. Modular Fuse Holders for Class J Fuses CH30J3 CH30J2I CH30J1 Description Specifications • Choice of LED indicator or non-indicating fuse holder • Comes in standard 1-, 2- and 3-Pole ganged assemblies where all fuses are extracted simultaneously • Meets requirements of IEC 60529 for IP-20 finger safe rating • 35 mm DIN rail and chassis (6-32 UNC Pan Head recommended) mounting features • Fuseholder wire ports dual wire rated from 18 to 3 AWG Agency Approvals • Listed UL 512, Guide IZLT, File E14853 • CSA Certified per C22.2 Nos. 39 Class 6225-01, File LR47235 • CE compliance for the European Union Low Voltage Directive Construction: Thermoplastic, with tin-plated copper clip UL Flammability: 94V-0 Voltage Ratings: 600 Volts AC Ampere Ratings: 1 - 60 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Minimum Indicating Voltage (neon lamp): 90 Volts Nominal Operating Current (neon lamp): 34 mA (460 VAC) CH Series Modular Fuse Holders for Class J Fuses Amp Part Rating Number CH30J1 CH30J2 CH30J3 30A CH30J1I CH30J2I CH30J3I CH60J1 CH60J2 CH60J3 60A CH60J1I CH60J2I CH60J3I Amps 0.5 to 30 31 to 60 Type Poles A B C D E F G H CH30J in (mm) Pcs/Pkg Weight (lbs.) Price Easy ID window 1 6 $121.00 Easy ID window 2 3 $169.00 Easy ID window 3 2 Neon indicator 1 6 Neon indicator 2 3 $194.00 Neon indicator 3 2 $186.00 Easy ID window 1 6 $163.00 Easy ID window 2 3 $191.00 Easy ID window 3 2 Neon indicator 1 6 Neon indicator 2 3 $228.00 Neon indicator 3 2 $207.00 18 -1 AWG Single 18 -3 AWG Dual 75°C $165.00 2.8 $142.00 $195.00 3.4 E Dimensions Dimension Maximum Wire Size $184.00 H G CH60J in (mm) 1.28 (32.5) 1.58 (40.0) 2.56 (65.0) 3.16 (80.0) 3.84 (97.5) 4.72 (120.0) 4.59 (116.6) 4.88 (124.0) 2.83 (71.8) 3.31 (84.1) 3.56 (90.4) 3.85 (97.9) 1.28 (32.5) 1.58 (40.0) 0.18 (4.44) 0.18 (4.44) D F 3 POLE CLASS J Modular Fuse Holder A B C Book 3 (14.3) eCP-198 Circuit Protection 30A AND 60A Ganging Assembly 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Accessories Accessories Part Number Description FP-2 Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V; 0-30A, 600V Multi-pole connection kit to connect new design multiple Class CC and Midget Class fuse holders together. Kit consists of 6 connectors and 3 handle pins to connect up to 4 fuse holders. JV-L* (Not Field Installable) Pcs/Pkg Price 1 $16.00 $6.25 Note: Will not work with retired design fuse holders shipped before November 1, 2009. *Roll pin punch or installation tool is required to install handle pins (Tool not sold by Automationdirect.com). FP2 Handle Pin Dimensions Diameter = 0.0625 in [1.58 mm] Length = 0.632 in [16.07 mm] JV-L JV-L Book 3 (14.3) eCP-218 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Cross Reference Guide Company Information Terminal Blocks Power Distribution Blocks CROSS REFERENCE GUIDE By manufacturers type reference or series number. Ampere ratings must be added for ordering purposes. FUSE TYPE VOLT EDISON BRUSH/ BUSSMANN MERSEN / GEC/CEFCO LITTELFUSE DORMAN GOULD UL CLASS CURRENT LIMITING FUSES (CSA CLASS) CC (HRCI-CC) Time-Delay 600 EDCC – LP-CC ATDR – CCMR Time-Delay 600 HCTR – FNQ-R ATQR – KLDR Fast-Acting RK1 RK5 J T Time-Delay Dual Element Time-Delay Dual Element 600 HCLR HCLR KTK-R ATMR CTK-R KLKR 250 LENRK – LPN-RK-SP A2DR – LLNRK 600 LESRK – LPS-RK-SP A6DR – LLSRK 250 ECNR – FRN-R TR – FLNR 600 ECSR – FRS-R TRS – FLSR JDL – LPJ AJT – JTD Time-Delay Dual Element 600 High-Speed AC Drive Extremely Fast-Acting 600 JHL – DFJ HSJ – – 300 TJN – JJN A3T – JLLN 600 TJS – JJS A6T – JLLS Midget 1/4”x1/4” Ceramic 1/4”x1/4”Glass 1/4”x1/4” Ceramic 1/4”x1/4”Glass 5x20 mm Glass 5x20 mm Glass 600 MCL MCL KTK ATM CTK KLK 250 MOL MOL BAF/BAN OTM – BLF 500 MEQ MEQ FNQ ATQ – FLQ MEN MEN FNM TRM – FLM 250/125 ABC ABC ABC GAB – 314 250/32 AGC AGC AGC GGC – 312 250 MDA MDA MDA – – 326 250/32 MDL MDL MDL GDL – 313 Fast-Acting 250/125 GMA GMA GMA GGM – 235 Medium Time-Delay 250/125 GMC GMC GMC GSC – – Fast-Acting 250 S500 BDB GDB GSB – 217 Time-Delay 250 S506 BDC GDC GDG – 218 FP-2 – – – Fast-Acting Time-Delay – old - 38072 – new - FP-2 Sensor Cables and Connectors M12 Junction Blocks Wiring Duct Cable Ties Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Fuse Puller Fuse Puller FP-2 Multi-wire Connectors Wire 250 Time-Delay ZIPLink Connection System Panel Interface Connectors UL CLASS GENERAL PURPOSE FUSES Fast-Acting Wiring Accessories Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-219