EDISON JDL Class J fuses are among the most popular current limiting time-delay fuses available. Their small physical size and high performance characteristics make Class J fuses ideal for any space-limited application.
JDL5
JDL40
ZIPLink Connection System
Interrupting Rating: 200,000 RMS Symmetrical Amps
Multi-wire Connectors
Self-Certified Interruptin Rating: 300,000 RMS Symmetrical Amps
Sensor Cables and Connectors
Self-Certified DC Ratings: Voltage Rating: JDL - 300 VDC Interrupting Rating: JDL - 20,000 Amperes DC
M12 Junction Blocks Panel Interface Connectors
Current Limiting: Class J Fuse
Wiring Duct Cable Ties
Agency Approvals
Wire
• UL Listed, Class J, Guide JDDZ, File E162363 • CSA Certified HRCI-J per C22.2, No. 248.8
Applications • Recommended for Type 2 (no damage) protection of IEC style motor starters and contactors. • Use to protect lower interrupting rated circuit breakers. • All general purpose circuits with inductive (high inrush) loads, including motor and motor branch circuits, and transformer circuits. Also suitable for lighting loads.
Bulk Multi-conductor Cables Wire Management Products
CROSS REFERENCE
AJT
LITTELFUSE
LPJ
MERSEN GOULD
BUSSMANN
EDISON
VOLTS
600 JDL
Power Supplies DC Converters Transformers and Filters
JTD URRENT LIMITING
JDL Dimensions inches (mm) DIMENSIONS Cat No. JFL and JDL, Class J
Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control
110-200 225-400 450-600
Blade Width F – – 3/4 1-1/8 1-5/8 2
Mounting Hole Spacing G H J – – – – – – 1/2 3-518 3/8 11/16 4-3/8 3/8 15/16 5-1/4 17/32 1 6 11/16
JDL Series Dimensions - Inches [mm]
A
B
2.25 0.81 [57.15] [20.6] 2.38 1.06 [60.5] [26.92] 4.63 1.13 [117.5] [28.6] 5.75 1.63 [146.1] [41.3] 7.13 2.13 [181] [54] 8 2.5 [203.2] [63.5]
Safety: Electrical Components K – – 9/32 9/32 13/32 17/32
Blade Width
70-100
Blade Thickness E – – 1/8 3/16 1/4 3/8
Blade Thickness
35-60
Barrel Length D – – 2-5/8 3 3-3/8 3-314
C
D
E
F
G
H
J
K
–
–
–
–
–
–
–
–
Barrel Length
1-30
Blade Length C – – 1 1-3/8 1-7/8 2-1/8
Blade Length
Range
Max. Dia. B 13/16 1-1/16 1-1/18 1-5/8 2-1/8 2-5/8
Max. Dia.
Overall Length A 2-1/4 2-3/8 4-5/8 5-3/4 7-1/8 8
Overall Length
Ampere Rating Range 1-30 35-60 70-100 110-200 225-400 450-600
Ampere Rating
Rated Part AMP Voltage Pcs/ Package Price Number Rating Pkg Weight AC Max 1 $124.00 JDL1 2 $124.00 JDL2 3 $124.00 JDL3 4 $130.00 JDL4 5 $124.00 JDL5 6 $124.00 JDL6 8 $130.00 JDL8 1.00 lb. $124.00 JDL10 10 $130.00 JDL12 12 $124.00 10 JDL15 15 $130.00 JDL17-5 17.5 $124.00 JDL20 20 $124.00 JDL25 25 $124.00 JDL30 30 $219.00 JDL35 35 $219.00 JDL40 40 $219.00 JDL45 45 2.00 lb $219.00 JDL50 50 600V 60 $219.00 JDL60 70 $219.00 JDL70 $219.00 JDL80 80 5 1.70 lb $235.00 JDL90 90 $219.00 JDL100 100 $92.00 JDL110 110 $87.00 JDL125 125 $92.00 4.25 lb JDL150 150 $93.00 JDL175 175 $87.00 JDL200 200 $156.00 JDL225 225 $146.00 1 JDL250 250 1.70 lb $183.00 JDL300 300 $159.00 JDL350 350 $146.00 JDL400 400 $243.00 JDL450 450 $243.00 2.80 lb JDL500 500 600 $243.00 JDL600
Ampere Rating: 1–600 Amps
• Space saving dimensions compared to Class R • Dual-Element construction provides superior time-delay to pass harmless motor or transformer surges • High performance with fatiguefree cycling capabilities • Extremely current limiting
JDL Series Dual-element Time-delay Fuses
Wiring Accessories
Voltage Rating: JDL - 600 VAC
JDL Features
JDL150
Power Distribution Blocks
Mounting Hole Spacing
–
–
–
–
–
–
–
–
1 [25.4] 1.38 [34.9] 1.88 [47.8] 2.13 [54]
2.63 [66.7] 3 [76.2] 3.38 [85.8] 3..75 [95.3]
0.13 [3.2] 0.19 [4.8] 0.25 [6.35] 0.38 [9.5]
0.75 [19.1] 1.13 [28.6] 1.63 [41.3] 2 [50.8]
0.5 [12.7] 0.69 [17.5] 0.94 [23.8] 1 [25.4]
3.63 [92.1] 4.38 [111.1] 5.25 [133.4] 6 [152.4]
0.38 [9.5] 0.38 [9.5] 0.56 [14.3] 0.75 [19.1]
0.28 [7.1] 0.28 [7.1] 0.41 [10.3] 0.53 [13.5]
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-145
Safety: Protective Wear Terms and Conditions
Prices as of October 21, 2015. Check Web site for most current prices.
Dual Element Time-Delay Class J Fuses Current Curves
600A
Ampere Rating
200
40,000 30,000
100 80 60
10 7 6 3
20,000 10,000 8,000 6,000
AMPERE RATING 60, 000 80, 000 100, 000
100
30, 000 40, 000
.1 .08 .06
20, 000
200
100
.2
400 300
6, 000 8, 000 10, 000
.4 .3
3, 000 4, 000
1 .8 .6
1,000 800 600
2, 000
2
A
2,000
600 800 1, 000
4 3
4,000 3,000
300 400
10 8 6
1
200
20
200, 000
40 30
TIME IN SECONDS
B
100,000 80,000 60,000
INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS
400A
200A 225A
125A
100A
15A 20A 30A 40A 50A 60A
300
10A
Cat. No. JDL (Amp) 600V
5A
Cat. No. JDL (Amp) 600V 3A
PEAK LET-THROUGH CURRENT CURVES
1A
AVERAGE TIME/CURRENT CURVE
RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS)
.04 .03
4,000 3,000
AMPERE RATING
2,000 1,000 800 600 400 300
A
200, 000
60, 000 80, 000 100, 000
30, 000 40, 000
20, 000
6, 000 8, 000 10, 000
3, 000 4, 000
100
2, 000
200
600 800 1, 000
400A 600A — —± — — 4,400 — 5,540 8,000 6,420 9,000 7,000 10,000 7,500 11,100 8,000 11,800 8,330 12,500 9,000 13,270 9,380 13,820 10,000 15,000 11,270 16,000 12,180 17,270 14,360 19,270 15,820 20,600
100 60 50 40 30 20 15
10,000 8,000 6,000
300 400
1,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000
Let-Thru Current (Apparent RMS Symmetrical) JDL (600V) Fuse Ratings 15A 30A 60A 100A 200A 270 470 750 — — 370 670 1,130 1,640 2,360 450 800 1,420 1,910 2,760 550 1,000 1,730 2,450 3,520 625 1,220 1,890 2,850 4,000 700 1,330 2,120 3,090 4,400 750 1,440 2,250 3,400 5,000 800 1,530 2,370 3,650 5,140 820 1,600 2,580 3,780 5,430 900 1,640 2,670 4,000 5,640 925 1,760 2,790 4,470 6,000 1,000 1,850 3,000 4,670 6,420 1,160 2,000 3,220 5,000 7,400 1,220 2,150 3,520 5,360 7,950 1,400 2,460 4,000 6,170 9,000 1,560 2,640 4,450 7,000 10,000
200
20,000
200
*Prosp. S.C.C.
600 400
40,000 30,000
100
Current-Limiting Effects
B
100,000 80,000 60,000
INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS
3,000 4,000
6,000 8,000 10,000
RMS SYMMETRICAL CURRENT IN AMPERES
2,000
600 800 1,000
300 400
200
60 80 100
30 40
20
6 8 10
2
1
.01
3 4
.02
RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)
*RMS Symmetrical Amperes Short-Circuit Current. NOTE:Data derived from Current Limiting Curves.
Book 3 (14.3)
eCP-146
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Selection Guide Line Overview
Company Information Terminal Blocks
The fuse selection guide below is a general summary of the specifications included for each fuse type. This selection guide does not include the many variables that can exist for specific situations such as local codes, unusual temperature, or other operating conditions. When selecting fuses, be sure to comply with any applicable PUBLIC SAFETY standards that apply to Overcurrent Protection Devices (OPD).
The Edison family of fuses, fuse blocks and fuse holders is divided into two classes: 1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T 2. General Purpose: Class M Midget and Small Dimension
Edison Fuses Selection Guide and General Specifications Description
Class J Fuse Type Fast-Acting Time-Delay Part Number JHL JDL Voltage Rating Amp Rating Interrupting Rating Current Limiting
Agency Approvals
Dimensions
600VAC 450VDC
Current Limiting Class RK1 Class T
Class RK5
Time-Delay
ECNR
ECSR LENRK LESRK
TJN
250VAC 250VAC VDC* 125VDC* 600VAC 125 600VAC 600VAC 300VAC (1-200A) 300VDC* (10-60A) 300VDC* 160 VDC 300VDC* 250VDC* 250VDC* (15-600A) (201-600A) (70-600A)
1 - 600
1 - 600
3 - 600
10 - 600
5 - 600
Class CC
Fast-Acting Fast-Acting
TJS
LCU
HCLR
600VAC
600V
600VAC 300VDC (15-20A)
1 - 600
601 - 1200
Time-Delay
HCTR
0.5 - 30
EDCC
600VAC 600VAC 300VDC (0.5-2.25A) (20–30A) 0.25 - 30
0.5 - 30
Class RK5
Class RK1
Class T
Class L
* Self-certified DC ratings
Edison Fuses Selection Guide and General Specifications General Purpose – Midget
Fuse Type
Fast-Acting
Part Number Voltage Rating
MCL
MOL
Time-Delay
MEQ
MEN
250 VAC to 30A) 600 VAC 250 VAC 500 VAC 250 VAC (0.5 125VDC: (0.5 to 30A)
Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30 Interrupting 100,000 10,000 RMS Amps RMS Amps Rating Current N/A Limiting
Agency Approvals
ABC
UL Listed to 248.14, File E162443 CSA Cert. C22.2 Part 59.2, LR 700489
0.5 to 30
Fast-Acting Glass
AGC
GMA
250VAC: 250VAC (0.1 to 10A) (0.063 - 3A) 32VAC: 125VAC (15 to 30A) (4 - 15A) 0.10 to 30
0.063 to 15
Medium Time- Time-Delay Time-Delay Fast-Acting Delay Glass Ceramic Glass Glass
S500
TimeDelay Glass
GMC
MDA
MDL
S506
250VAC (0.5 - 3A) 125VAC (4 - 10A)
250VAC 125VDC (20A)
250VAC: (0.0625 to 8A) 32VAC: (10 to 20A)
250VAC
250VAC
0.5 to 10
0.5 to 20
0.0625 to 20
0.032 to 10
0.25 to 6.3
See specifications table on product pages
UL Listed standard 248-14 UL Listed Guide and File nos. Designed to UL/CSA 248-14 (ABC 0.25-20 A): UL Listed, Guide JDYX, File (AGC 1/100-10 A) E19180 63mA-6A JDYX and E19180 UL Recognition Guide and UL Recognition, Guide JDYX2, File nos. (ABC 20-30A):(AGC File E19180, 7A-15A 11-30) CSA Certified, File JDYX2 and E19180 053787_C_000, CSA Certification Record No: 63mA-6A Class 1422-01 053787 C 000 and Class No: 1422 01 and 1422 30 0.197” x 0.788” (5mm x 20mm)
UL Listed standard 248-14 UL Listed Card: MDA 2/10-20A , MDL 1/16-8A (Guide JDYX, File E19180 UL Recognized Card: MDA 25-30A MDL 9-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15A (Class No. 1422-01)
L Recognized Guide U JDYX2, File E19180 Semko Approval VDE Approval BSI Approval IMQ Approval RoHS compliant
1/4” x 1-1/4”, (6.3mm x 32mm)
0.197” x 0.788” (5mm x 20mm) Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Wiring Duct
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters
Tools Test Equipment Enclosures
Safety: Electrical Components Safety: Protective Wear Terms and Conditions
N/A
1/4” x 1-1/4”, (6.3mm x 32mm)
Panel Interface Connectors
Enclosure Climate Control
RoHS
Dimensions ferrule (in): 13/32 length (in): 1-1/2
M12 Junction Blocks
Circuit Protection
General Purpose – Small Dimension Electronic Fast-Acting Ceramic
Sensor Cables and Connectors
Wire
Class CC
UL Listed Class J UL Listed Guide JDDZ Class J UL Listed, File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ, UL Listed, Class T, Std. 248-10 UL Listed to 248.4, Class CC, CSA Certified File E162363 File E162363 Guide JDDZ, File E162363 CSA Certified, Guide JDDZ, File E162363, HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per HRC-L C22.2 certified HRCI-MISC per C22.2 C22.2, HRCI-J per File 700489 C22.2, No. 248.12, File 53787, No. 248.10, CSA No. 248.8 C22.2, No. (LENRK CSA File 053787) Class 1422-02 & 1422-82 Class 1422-02, No. 248.4, File 700489 File 700489 248.8 File 53787 RoHS File 700489 compliant See product specification pages. ferrule (in): 13/32, length (in): 1-1/2
Description
ZIPLink Connection System
Cable Ties
200,000 RMS Symmetrical Amps Class J
Wiring Accessories
Multi-wire Connectors
Class L
Extremely Fast-Acting
Power Distribution Blocks
Circuit Protection
eCP-143
Prices as of October 21, 2015. Check Web site for most current prices.
Fuse Blocks for Class J Fuses Description
Specifications
For use with Edison JDL class J fuses
Construction: T hermoplastic, UL Flammability; 94V-0
Terminal type: • C = Box lug type • CR = Box lug type, with retaining clip • P = Pressure plate. Clip reinforcin springs are standard on fuseblocks rated 100A and above.
Voltage Ratings: 600 Volts AC Ampere Ratings: 0.50 - 600 Amps Short-circuit current Rating: 200,000 RMS Symmetrical Amps
Agency Approvals • UL Listed, UL 512, Guide IZLT, File E14853 • CSA, certified, C22.2 No. 39, Class 6225-01, File 47235
J60060-1C
Class J Fuse Blocks Part Number J60030-1P J60030-2P J60030-3P J60060-1C J60060-2C J60060-3C J60100-1CR J60100-3CR J60200-1CR J60200-3CR J60400-1CR J60400-3CR J60600-1CR J60600-3CR*
J60030-2P
Amps Poles
Maximum Wire Size
1 0.5 to 30
31 to 60
61 to 100 101 to 200 201 to 400 401 to 600
2
#10-14 Cu
Wt. Fig # Pcs/ Pkg (lbs.) Price 1
0.44
$18.50
2
0.35
$32.00
3
3
0.45
$48.50
1
1
0.44
$20.50 $39.00
2
2
0.35
3
3
0.55
$50.00
1
4
0.98
$34.50
3 1 3 1 3 1 3
#2-14 Cu-Al
1/0-8 Cu-Al 250MCM-6 Cu-Al 500MCM-4 Cu-Al
5
1
6
1.55
$89.00
1.70
$133.00
9
6.70
$396.00
7
3.10
$202.00
10
14.0
$568.00
(2) 500MCM-4/0 8 Cu-Al 11
5.40
$328.00
8.0
$969.00
* Not UL, Please use (3) J60600-1CR to assemble a 3 pole UL Fuseblock
Class J Fuseholder Dimensions
J60030-3P
0.5 Amp to 60 Amp 2.42 [61.3]
1.70 [43.2] .75 [19.1]
3.20 [81.3] 2.25 [57.2]
4.70 [119.4]
2.28 [58] .30 [7.62]
2.25 [57.2]
.75 [19.1]
C L
CL
4.01 [102]
6.28"
[160
1.50 [38.1]
Figure 1
Figure 2
Figure 3
Note: All dimensions shown in inches [mm] Book 3 (14.3)
eCP-196
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Fuse Blocks for Class J Fuses
Terminal Blocks
0 3]
2]
Company Information
4.70
.75 [19.1]
2.28 [58] .30 [7.62]
61 Amp[119.4] to 100 Amp 2.25 [57.2]
[49.4]
.94 [23.8]
[38.1]
1.58 [40.1]
Power Distribution Blocks
5 [127]
Wiring Accessories
[5.6]
[12.7]
C L
CL
4.01 [102]
6.28"
.22 [5.6] Dia. .5 [12.7] C'Bore
ZIPLink Connection System
[160]
Multi-wire Connectors
3.14 [79.8] 1.50 [38.1]
1.75 [44.5]
101 Amp to 200 Amp 3.1 [78.7]
3 [76.2] 2 [50.8] 3.06 [77.7]
Figure 4
.5 [12.7]
6.13 [155.7]
Wiring Duct
3 [76.2] 1.75 [44.5]
3.5 [88.9] 7.5 [191]
Cable Ties
.344 [8.74] dia. hole through .750 [19.1] dia. c'bore
Wire Bulk Multi-conductor Cables
4 [101.6] 1 [25.4]
.625 [15.9]
Power Supplies
10.51 [267] 9.00 [228] 6.00 [152.4]
.56 [14.2]
Wire Management Products
.750 [19.1]
Figure 7
Figure 6 201 Amp to 400 Amp
Panel Interface Connectors
3.15 [80]
6.13 [155.7] 1.69 [42.9]
.34 [8.6] dia.
M12 Junction Blocks
Figure 5 8.31 [211.1] 7.00 [177.8]
.75 [19.1] .31 [7.8]
.75 [19.1] c'bore
Sensor Cables and Connectors
1.5 [38.1]
DC Converters
4.00 [101.6]
Transformers and Filters Circuit Protection
7.50 [191]
.75 [19.1] c'bore .34 [8.6] dia.
Tools
.344 [8.7] dia. hole through .750 [19.1] dia. c'bore
2.0 [50.8]
.5 [12.7]
.50 [12.7]
Test Equipment Enclosures Enclosure Climate Control
Figure 9
Figure 8
1.00 [25.4]
Safety: Electrical Components
401 Amp to 600 Amp 4 [101.6] 1.75 [44.5]
Safety: Protective Wear 4.99 [126.7]
1.125 [28.6]
14.144 [359.3] 11.00 [279.4]
1 [25.4] .56 [14.2]
Terms and Conditions
4.99 [126.7]
3.25 [82.6] 8.875 [225.4]
2.38 [60.5]
.75 [19.1] c'bore .34 [8.6] dia.
Figure 10
8.88 [226] 2.88 [73.2]
Note: All dimensions shown in inches [mm]
.344 [8.7] dia. hole through .750 [19.1] dia. c'bore
Figure 11
.50 [12.7]
1.00 [25.4]
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-197
Prices as of October 21, 2015. Check Web site for most current prices.
Modular Fuse Holders for Class J Fuses
CH30J3
CH30J2I
CH30J1
Description
Specifications
• Choice of LED indicator or non-indicating fuse holder • Comes in standard 1-, 2- and 3-Pole ganged assemblies where all fuses are extracted simultaneously • Meets requirements of IEC 60529 for IP-20 finger safe rating • 35 mm DIN rail and chassis (6-32 UNC Pan Head recommended) mounting features • Fuseholder wire ports dual wire rated from 18 to 3 AWG
Agency Approvals • Listed UL 512, Guide IZLT, File E14853 • CSA Certified per C22.2 Nos. 39 Class 6225-01, File LR47235 • CE compliance for the European Union Low Voltage Directive
Construction: Thermoplastic, with tin-plated copper clip UL Flammability: 94V-0 Voltage Ratings: 600 Volts AC Ampere Ratings: 1 - 60 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Minimum Indicating Voltage (neon lamp): 90 Volts Nominal Operating Current (neon lamp): 34 mA (460 VAC)
CH Series Modular Fuse Holders for Class J Fuses Amp Part Rating Number CH30J1 CH30J2 CH30J3 30A CH30J1I CH30J2I CH30J3I CH60J1 CH60J2 CH60J3 60A CH60J1I CH60J2I CH60J3I
Amps
0.5 to 30
31 to 60
Type
Poles
A B C D E F G H
CH30J in (mm)
Pcs/Pkg
Weight (lbs.)
Price
Easy ID window
1
6
$121.00
Easy ID window
2
3
$169.00
Easy ID window
3
2
Neon indicator
1
6
Neon indicator
2
3
$194.00
Neon indicator
3
2
$186.00
Easy ID window
1
6
$163.00
Easy ID window
2
3
$191.00
Easy ID window
3
2
Neon indicator
1
6
Neon indicator
2
3
$228.00
Neon indicator
3
2
$207.00
18 -1 AWG Single 18 -3 AWG Dual 75°C
$165.00
2.8
$142.00
$195.00
3.4
E
Dimensions Dimension
Maximum Wire Size
$184.00
H
G
CH60J in (mm)
1.28 (32.5)
1.58 (40.0)
2.56 (65.0)
3.16 (80.0)
3.84 (97.5)
4.72 (120.0)
4.59 (116.6)
4.88 (124.0)
2.83 (71.8)
3.31 (84.1)
3.56 (90.4)
3.85 (97.9)
1.28 (32.5)
1.58 (40.0)
0.18 (4.44)
0.18 (4.44)
D F
3 POLE CLASS J Modular Fuse Holder
A
B C
Book 3 (14.3)
eCP-198
Circuit Protection
30A AND 60A Ganging Assembly
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Accessories Accessories Part Number
Description
FP-2
Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V; 0-30A, 600V Multi-pole connection kit to connect new design multiple Class CC and Midget Class fuse holders together. Kit consists of 6 connectors and 3 handle pins to connect up to 4 fuse holders.
JV-L* (Not Field Installable)
Pcs/Pkg Price 1
$16.00 $6.25
Note: Will not work with retired design fuse holders shipped before November 1, 2009. *Roll pin punch or installation tool is required to install handle pins (Tool not sold by Automationdirect.com).
FP2
Handle Pin Dimensions Diameter = 0.0625 in [1.58 mm] Length = 0.632 in [16.07 mm]
JV-L JV-L
Book 3 (14.3)
eCP-218
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Cross Reference Guide
Company Information Terminal Blocks Power Distribution Blocks
CROSS REFERENCE GUIDE By manufacturers type reference or series number. Ampere ratings must be added for ordering purposes. FUSE TYPE
VOLT EDISON
BRUSH/ BUSSMANN MERSEN / GEC/CEFCO LITTELFUSE DORMAN GOULD
UL CLASS CURRENT LIMITING FUSES (CSA CLASS) CC (HRCI-CC)
Time-Delay
600
EDCC
–
LP-CC
ATDR
–
CCMR
Time-Delay
600
HCTR
–
FNQ-R
ATQR
–
KLDR
Fast-Acting RK1 RK5 J T
Time-Delay Dual Element Time-Delay Dual Element
600
HCLR
HCLR
KTK-R
ATMR
CTK-R
KLKR
250
LENRK
–
LPN-RK-SP
A2DR
–
LLNRK
600
LESRK
–
LPS-RK-SP
A6DR
–
LLSRK
250
ECNR
–
FRN-R
TR
–
FLNR
600
ECSR
–
FRS-R
TRS
–
FLSR
JDL
–
LPJ
AJT
–
JTD
Time-Delay Dual Element 600 High-Speed AC Drive Extremely Fast-Acting
600
JHL
–
DFJ
HSJ
–
–
300
TJN
–
JJN
A3T
–
JLLN
600
TJS
–
JJS
A6T
–
JLLS
Midget
1/4”x1/4” Ceramic 1/4”x1/4”Glass 1/4”x1/4” Ceramic 1/4”x1/4”Glass 5x20 mm Glass 5x20 mm Glass
600
MCL
MCL
KTK
ATM
CTK
KLK
250
MOL
MOL
BAF/BAN
OTM
–
BLF
500
MEQ
MEQ
FNQ
ATQ
–
FLQ
MEN
MEN
FNM
TRM
–
FLM
250/125 ABC
ABC
ABC
GAB
–
314
250/32 AGC
AGC
AGC
GGC
–
312
250
MDA
MDA
MDA
–
–
326
250/32 MDL
MDL
MDL
GDL
–
313
Fast-Acting
250/125 GMA
GMA
GMA
GGM
–
235
Medium Time-Delay
250/125 GMC
GMC
GMC
GSC
–
–
Fast-Acting
250
S500
BDB
GDB
GSB
–
217
Time-Delay
250
S506
BDC
GDC
GDG
–
218
FP-2
–
–
–
Fast-Acting Time-Delay
–
old - 38072 – new - FP-2
Sensor Cables and Connectors M12 Junction Blocks
Wiring Duct Cable Ties
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools
Fuse Puller Fuse Puller FP-2
Multi-wire Connectors
Wire
250
Time-Delay
ZIPLink Connection System
Panel Interface Connectors
UL CLASS GENERAL PURPOSE FUSES Fast-Acting
Wiring Accessories
Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-219