Product Specifications 810009011/DB    |    M-012 012--LA LA--8W 8W--F12NS/25D Figure­8, Single Jacket/Single Armor, Gel­Free, Outdoor Stranded Loose Tube cable  (0.250 in messenger)   l Corrugated steel tape armor is strong yet flexible, providing additional crush and  rodent protection   Representative Image       General Specifications Cable Type  Stranded loose tube  Construction Type  Armored  Subunit Type  Gel­free    Construction Materials Fiber Type Solution  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Jacket Material  PE  Total Fiber Count  12  Armor Type  Corrugated steel  Fiber Type  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Fiber Type, quantity  12  Fibers per Subunit, quantity  12  Jacket Color  Black  Jacket UV Resistance  UV stabilized    Dimensions Buffer Tube/Subunit Diameter  2.50 mm | 0.10 in  Cable Weight  341.0 kg/km | Diameter Over Jacket  11.80 mm 0.46 in  Diameter Over Messenger Jacket  8.90 mm | 0.35 in  Filler, quantity  4  Height Over Jacket  23.00 mm Subunit, quantity  1  Width Over Jacket  11.80 mm | 229.0 lb/kft  | 0.91 in  | 0.46 in  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 1 of 3 April 14, 2016 Product Specifications 810009011/DB   |   M 810009011/DB   |   M--012 012--LA LA--8W 8W--F12NS/25D   Physical Specifications Minimum Bend Radius, loaded  17.7 cm | 7.0 in  Minimum Bend Radius, unloaded  11.8 cm | 4.6 in  Tensile Load, long term, maximum  15000 N | 3372 lbf  Tensile Load, short term, maximum  21000 N | 4721 lbf  Vertical Rise, maximum  | 1476.0 ft  450.0 m   Environmental Specifications Environmental Space  Aerial, self­support  Installation Temperature  ­30 °C to +70 °C (­22 °F to +158 °F)  Operating Temperature  ­40 °C to +70 °C (­40 °F to +158 °F)  Storage Temperature  ­40 °C to +75 °C (­40 °F to +167 °F)    Mechanical Test Specifications Compression  44 N/mm | 250 lb/in  Compression Test Method  FOTP­41 Flex  35 cycles  Flex Test Method  FOTP­104 Impact  2.94 N­m | 2.17 ft lb  Impact Test Method  FOTP­25 Strain  See long and short term tensile loads  Strain Test Method  FOTP­33 Twist  10 cycles  Twist Test Method  FOTP­85 Water Penentration  24 h  Water Penentration Test Method  FOTP­82 | IEC 60794­1 E3  | | IEC 60794­1 E6  IEC 60794­1 E4  | IEC 60794­1 E1  | IEC 60794­1 E7  | IEC 60794­1 F5    Environmental Test Specifications Cable Freeze  ­2 °C | 28 °F  Cable Freeze Test Method  FOTP­98 Heat Age  ­40 °C to +85 °C (­40 °F to +185 °F)  Heat Age Test Method  IEC 60794­1 F9  Low High Bend  ­30 °C to +60 °C (­22 °F to +140 °F)  Low High Bend Test Method  FOTP­37 Temperature Cycle  ­40 °C to +70 °C (­40 °F to +158 °F)  Temperature Cycle Test Method  FOTP­3 | | | IEC 60794­1 F15  IEC 60794­1 E11  IEC 60794­1 F1    Qualification Specifications Cable Qualification Standards  ANSI/ICEA S­87­640 | EN 187105 | Telcordia GR­20  Regulatory Compliance/Certifications Agency RoHS 2011/65/EU Classification ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 2 of 3 April 14, 2016 Product Specifications 810009011/DB   |   M 810009011/DB   |   M--012 012--LA LA--8W 8W--F12NS/25D ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system Included Products DB­8W­LT   (Product Component—not orderable)  — LightScope ZWP® Singlemode Fiber  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 3 of 3 April 14, 2016