Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Manual Couplers Application & selection Shown: MCH-31, MCRA-11, MCRC-21, MCH-21, MCR-21 Manual Couplers Collet-Lok® product line …convenient connection • Use on palletized fixtures • Available with or without an internal pilot operated (P.O.) check valve Swing clamps • Optional coupler block available to add circuit for air part present sensing • Manifold porting • Porting for tubing connections Linear Clamps Work supports • Filtration to prevent contamination • Removable front plate provides access to the front filters and check cartridge The Enerpac manual coupler is available as a dual connection model or dual connection with optional air circuit for part present sensing. The fixture side receiver is available with or without an internal pilot operated check valve. Filtration • Top port accommodates an accumulator or gauge provides protection from contamination. Power sources Manual Coupler Circuits With auxiliary air circuit Manual coupler applications: Pallet Components Valves • With P.O. check - Use MCRC-21 for a complete, unitized coupler receiver solution Without auxiliary air circuit With P.O. check • Without P.O. check: - Use MCR-21 when using a remote mounted Pilot Operated Check Valve Without P.O. check z Enerpac manual couplers simplify the process of connecting and disconnecting to a palletized fixture. 166 ® Model number Basic configurations Circuits MCRC-21 Pallet receiver with P.O. check Two Hydraulic MCR-21 Pallet receiver without P.O. check Two Hydraulic MCRA-11 Auxiliary air circuit receiver block MCH-21 Operator handle Two Hydraulic MCH-31 Operator handle Two Hydraulic, One Air MCSB-21 Storage block N/A MCPS-21 Proximity switch kit N/A One Air MC Series Select your components Max. Flow: 4 GPM Pressure: 0-5000 psi MCRC-21 Pallet Receiver with P.O. Check An internal pilot operated check valve and multiple ports to accommodate a gauge or accumulator make the MCRC-21 a great choice of coupler receiver for use in a palletized fixture. Internal filtration protects the check from contamination. Use with the MCH-21 operator handle. E Acopladores manuales F Manuel coupleur D Manuelle kupplung MCR-21 Pallet Receiver For applications where the pilot operated check valve is remote mounted in the fixture circuit, use the MCR-1. Internal filtration protects the circuit from outside contamination. Options FZ Series fittings 194 ▸ MCRA-11 Auxiliary air circuit receiver Hoses and couplers The MCRA-11 is used to provide an additional connection for use with air part sensing circuits. Use with either the MCRC-21 or the MCR-21. Use with the MCH-31 operator handle. 192 ▸ Pilot operated check valves 153 ▸ MCSB-21 Operator Handle Storage Block Proper storage of the MCH-21 or MCH-31 handle prevents contamination of the couplers, and makes sure that the handle is disconnected from the fixture. Use the MCPS-21 proximity switch to confirm proper storage as an input to the machine control. Accumulators 162 ▸ MCH-21 Two Coupler Operator Handle Important Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers. Do not exceed maximum flow and pressure. Use the MCH-31 when using the MCRA-11 with either the MCRC-21 or MCR-21 receivers. Replacement hydraulic nozzle Replacement filter kit 100 - 5000 AH654 Fl2201K – MCRC-21 100 - 5000 AH654 Fl2201K – MCR-21 10 - 100* AH654 Fl2201K – MCRA-11 100 - 5000 AR650 – – MCH-21 100 - 5000 AR650 – – MCH-31 – AH654 – – – – – 24 VDC MCSB-21 MCPS-21 Voltage Yellow pages Model number Operating pressure psi * Air pressure www.enerpacwh.com System components MCH-31 Pallet components Use the MCH-21 with either the MCRC-21 or the MCR-21 pallet receiver. ® 167 Manual Couplers Dimensions & options Shown: MCH-21, MCR-21 Collet-Lok® product line MCRC-21 Receiver with P.O. check .59 2.87 1.75 1.44 1.25 .64 AH-654 1.86 MCR-21 A 3.50 Receiver without P.O. check 1.25 .59 Ø.188 x .62 Lg. spring roll pin (provided) 1.47 1.75 .31 5/16–18 x 1.50" Lg. SHCS (provided) .37 The Enerpac MCH-21 two passage operator handle conveniently connects and disconnects to the MCR-21 two passage receiver utilizing a simple push-on, pull-off action. B .56 Serie MCR e MCH .64 Power sources 2.25 Linear Clamps Work supports 4.50 Swing clamps 2.03 .56 (3) 5/16–18 x 1.50" Lg. SHCS (provided) AH-654 1.86 Valves MCRA-11 Auxiliary air circuit receiver B A 3.50 (2) #10-24 x 1.50" Lg. SHCS (provided) .47 .94 1.25 .28 .64 Pallet Components 2.25 .19 1.86 AIR AH-654 1.50 MCR-21 with MCRA-11 Receiver with air passage and without P.O. check Ø.188 x .62" Lg. spring roll pin (provided) .59 1.25 .94 5/16–18 x 1.50" Lg. SHCS (provided) 2.53 1.75 1.47 .37 .47 .64 2.25 .37 .56 (2) #10–24 x 1.50" Lg. SHCS (provided) 1.86 168 ® AH-654 AIR 1.50 B 3.50 A Can mount air passage on either side Dimensions & options MCR and MCH-series Max. Flow: 4 GPM MCRC-21 with MCRA-11 (2) #10–24 x 1.50" Lg. SHCS (provided) 2.87 1.25 E Acopladores manuales 1.75 1.44 F Manuel coupleur .56 .59 .47 Pressure: 0-5000 psi 2.53 2.25 4.50 1.87 .94 D Manuelle kupplung 2.03 (3) 5/16–18 x 1.50" Lg. SHCS (provided) .64 Options AIR AH-654 1.86 B 1.50 MCSB-21 Storage block (2) 1/4–20 x .50" Lg. SHCS (provided) 3.50 A FZ Series fittings Can mount air passage on either side 194 ▸ MCPS-21 Optional proximity switch Hoses and couplers (2) M5–4.8 x 20mm Lg. SHCS with jam nuts (provided) .75 .43 192 ▸ 2.00 Pilot operated check valves 1.81 2.25 153 ▸ Accumulators .57 162 ▸ 1.86 3.50 ① Optional proximity switch is available. See MCPS-21 Operator handle 12.00 ø1.50 Knurled gripping area Knurled gripping area 3.62 3.62 1/4–18 NPT Female Thread Hex Do not exceed maximum flow and pressure. Operator handle ø1.50 Yellow pages MCH-31 Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers. System components AR-650 2.00 5.00 .81 Important 13.00 Knurled gripping area Knurled gripping area 3.62 .81 Hex www.enerpacwh.com 4.50 3.62 2.00 2.00 Pallet components MCH-21 AR-650 1/4–18 NPT Female Thread ® 169 Manual Couplers Mounting patterns Shown: MCR-21 MCRC-21 Receiver with P.O. check – MCR-21 Collet-Lok® product line Mtg. hole pattern Receiver without P.O. check – Mtg. hole pattern 2.87 *1.75 1.44 (3) 5/16–18 x .62" Swing clamps (2) Ø.25 feed holes 5/16–18 x .62" (2) Ø.25 feed holes (2) 2.03 1.00 *1.75 Ø.188 x .31" Work supports Linear Clamps 1.00 The MCR-21 two passage receiver features multiple SAE #4 ports as well as manifold mount ports for easy plumbing to a fixture. Internal filtration in all receiver models protects the circuit from external contamination. 2.00 *1.69 .37 *3.94 2.00 1.47 MCR series MCRC-21 with MCRA-11 Receiver with air passage and with P.O check – Mtg. hole pattern *3.75 (3) 5/16–18 x .62" 2.53 2.87 1.00 .31 *3.94 2.00 (2) 2.03 .94 (2) #10–24 x .50" Valves (2) Ø.25 feed holes (2) 1.88 Power sources 1.44 .47 Pallet Components Ø.19 feed holes Can mount air passage on either side. Receiver with air passage and without P.O check – Mtg. hole pattern (3) 5/16–18 x .62" *3.75 Ø.19 feed holes (2) Ø.25 feed holes Ø.188 x .31" .37 .37 1.47 .31 (2) #10–24 x .50 2.53 .94 .47 1.00 2.00 1.69 MCR-21 with MCRA-11 Can mount air passage on either side. * Minimum from edge of tool plate 170 ® Mounting patterns, dimensions & options MCSB-21 MCR and MCS-series Max. Flow: 4 GPM Storage Block – Mounting Hole Pattern Pressure: 0-5000 psi 2X Ø.04 x .62" E Acopladores manuales 1/4–20 x .50" F Manuel coupleur 2.00 .75 1.81 D Manuelle kupplung Options Manifold and Port Dimensions (2) 1/16-27 NPTF dry seal taper pipe plugs (provided). Remove when manifold mounting. 4.00 .75 2.00 B FZ Series fittings 194 ▸ .53 Hoses and couplers .44 .63 A .53 1/16-27 NPTF dry seal taper pipe plugs (provided). Remove when manifold mounting. (2) O-rings (provided). Use when manifold mounting O-ring (provided). Use when manifold mounting. (2) Ø.25 feed holes (2) Ø.19 feed holes 192 ▸ Pilot operated check valves 153 ▸ Rear view (2) .56 Accumulators (6) Port passages SAE #4 plugs (provided) Accumulator or gauge port only SAE #4 plug (provided) 162 ▸ (4) Port passages SAE #2 plugs (provided) Top view A Important Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers. AIR Do not exceed maximum flow and pressure. System components B Pallet components .51 Bleeder port only SAE #2 plug (provided) Yellow pages www.enerpacwh.com ® 171