Transcript
Manual Couplers Application & selection Shown: MCH-31, MCRA-11, MCRC-21, MCH-21, MCR-21
Manual Couplers
Collet-Lok® product line
…convenient connection • Use on palletized fixtures • Available with or without an internal pilot operated (P.O.) check valve
Swing clamps
• Optional coupler block available to add circuit for air part present sensing • Manifold porting • Porting for tubing connections
Linear Clamps
Work supports
• Filtration to prevent contamination • Removable front plate provides access to the front filters and check cartridge The Enerpac manual coupler is available as a dual connection model or dual connection with optional air circuit for part present sensing. The fixture side receiver is available with or without an internal pilot operated check valve. Filtration
• Top port accommodates an accumulator or gauge
provides protection from contamination.
Power sources
Manual Coupler Circuits With auxiliary air circuit
Manual coupler applications:
Pallet Components
Valves
• With P.O. check - Use MCRC-21 for a complete, unitized coupler receiver solution
Without auxiliary air circuit
With P.O. check
• Without P.O. check: - Use MCR-21 when using a remote mounted Pilot Operated Check Valve Without P.O. check
z Enerpac manual couplers simplify the process of connecting and disconnecting to a palletized fixture.
166
®
Model number
Basic configurations
Circuits
MCRC-21
Pallet receiver with P.O. check
Two Hydraulic
MCR-21
Pallet receiver without P.O. check
Two Hydraulic
MCRA-11
Auxiliary air circuit receiver block
MCH-21
Operator handle
Two Hydraulic
MCH-31
Operator handle
Two Hydraulic, One Air
MCSB-21
Storage block
N/A
MCPS-21
Proximity switch kit
N/A
One Air
MC Series Select your components
Max. Flow: 4 GPM Pressure: 0-5000 psi
MCRC-21 Pallet Receiver with P.O. Check An internal pilot operated check valve and multiple ports to accommodate a gauge or accumulator make the MCRC-21 a great choice of coupler receiver for use in a palletized fixture. Internal filtration protects the check from contamination. Use with the MCH-21 operator handle.
E Acopladores manuales F Manuel coupleur D Manuelle kupplung
MCR-21 Pallet Receiver For applications where the pilot operated check valve is remote mounted in the fixture circuit, use the MCR-1. Internal filtration protects the circuit from outside contamination.
Options FZ Series fittings
194 ▸
MCRA-11 Auxiliary air circuit receiver
Hoses and couplers
The MCRA-11 is used to provide an additional connection for use with air part sensing circuits. Use with either the MCRC-21 or the MCR-21. Use with the MCH-31 operator handle.
192 ▸ Pilot operated check valves
153 ▸
MCSB-21 Operator Handle Storage Block Proper storage of the MCH-21 or MCH-31 handle prevents contamination of the couplers, and makes sure that the handle is disconnected from the fixture. Use the MCPS-21 proximity switch to confirm proper storage as an input to the machine control.
Accumulators
162 ▸
MCH-21 Two Coupler Operator Handle
Important Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers.
Do not exceed maximum flow and pressure.
Use the MCH-31 when using the MCRA-11 with either the MCRC-21 or MCR-21 receivers.
Replacement hydraulic nozzle
Replacement filter kit
100 - 5000
AH654
Fl2201K
–
MCRC-21
100 - 5000
AH654
Fl2201K
–
MCR-21
10 - 100*
AH654
Fl2201K
–
MCRA-11
100 - 5000
AR650
–
–
MCH-21
100 - 5000
AR650
–
–
MCH-31
–
AH654
–
–
–
–
–
24 VDC
MCSB-21 MCPS-21
Voltage
Yellow pages
Model number
Operating pressure psi
* Air pressure
www.enerpacwh.com
System components
MCH-31
Pallet components
Use the MCH-21 with either the MCRC-21 or the MCR-21 pallet receiver.
®
167
Manual Couplers Dimensions & options Shown: MCH-21, MCR-21
Collet-Lok® product line
MCRC-21 Receiver with P.O. check .59
2.87 1.75 1.44
1.25
.64
AH-654
1.86
MCR-21
A
3.50
Receiver without P.O. check
1.25 .59 Ø.188 x .62 Lg. spring roll pin (provided)
1.47
1.75
.31
5/16–18 x 1.50" Lg. SHCS (provided)
.37
The Enerpac MCH-21 two passage operator handle conveniently connects and disconnects to the MCR-21 two passage receiver utilizing a simple push-on, pull-off action.
B
.56
Serie MCR e MCH
.64
Power sources
2.25
Linear Clamps
Work supports
4.50
Swing clamps
2.03
.56
(3) 5/16–18 x 1.50" Lg. SHCS (provided)
AH-654
1.86
Valves
MCRA-11 Auxiliary air circuit receiver
B
A
3.50
(2) #10-24 x 1.50" Lg. SHCS (provided)
.47
.94
1.25
.28
.64
Pallet Components
2.25
.19
1.86
AIR
AH-654
1.50
MCR-21 with MCRA-11 Receiver with air passage and without P.O. check Ø.188 x .62" Lg. spring roll pin (provided)
.59
1.25
.94
5/16–18 x 1.50" Lg. SHCS (provided)
2.53 1.75
1.47 .37
.47
.64
2.25
.37
.56
(2) #10–24 x 1.50" Lg. SHCS (provided)
1.86
168
®
AH-654
AIR
1.50
B
3.50
A
Can mount air passage on either side
Dimensions & options
MCR and MCH-series Max. Flow: 4 GPM
MCRC-21 with MCRA-11 (2) #10–24 x 1.50" Lg. SHCS (provided)
2.87
1.25
E Acopladores manuales
1.75 1.44
F Manuel coupleur .56
.59 .47
Pressure: 0-5000 psi
2.53
2.25
4.50
1.87
.94
D Manuelle kupplung 2.03
(3) 5/16–18 x 1.50" Lg. SHCS (provided)
.64
Options AIR
AH-654
1.86
B
1.50
MCSB-21 Storage block (2) 1/4–20 x .50" Lg. SHCS (provided)
3.50
A
FZ Series fittings
Can mount air passage on either side
194 ▸
MCPS-21 Optional proximity switch
Hoses and couplers
(2) M5–4.8 x 20mm Lg. SHCS with jam nuts (provided)
.75
.43
192 ▸
2.00
Pilot operated check valves
1.81
2.25
153 ▸ Accumulators
.57
162 ▸ 1.86
3.50 ① Optional proximity switch is available. See MCPS-21
Operator handle
12.00 ø1.50
Knurled gripping area
Knurled gripping area
3.62
3.62
1/4–18 NPT Female Thread
Hex
Do not exceed maximum flow and pressure.
Operator handle
ø1.50
Yellow pages
MCH-31
Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers.
System components
AR-650 2.00
5.00
.81
Important
13.00 Knurled gripping area
Knurled gripping area
3.62
.81 Hex
www.enerpacwh.com
4.50
3.62
2.00
2.00
Pallet components
MCH-21
AR-650
1/4–18 NPT Female Thread
®
169
Manual Couplers Mounting patterns Shown: MCR-21
MCRC-21 Receiver with P.O. check –
MCR-21
Collet-Lok® product line
Mtg. hole pattern
Receiver without P.O. check – Mtg. hole pattern
2.87 *1.75 1.44
(3) 5/16–18 x .62"
Swing clamps
(2) Ø.25 feed holes
5/16–18 x .62" (2) Ø.25 feed holes
(2) 2.03
1.00
*1.75
Ø.188 x .31"
Work supports
Linear Clamps
1.00
The MCR-21 two passage receiver features multiple SAE #4 ports as well as manifold mount ports for easy plumbing to a fixture. Internal filtration in all receiver models protects the circuit from external contamination.
2.00
*1.69
.37
*3.94
2.00
1.47
MCR series
MCRC-21 with MCRA-11
Receiver with air passage and with P.O check – Mtg. hole pattern
*3.75 (3) 5/16–18 x .62"
2.53 2.87
1.00
.31
*3.94
2.00
(2) 2.03
.94
(2) #10–24 x .50"
Valves
(2) Ø.25 feed holes
(2) 1.88
Power sources
1.44
.47
Pallet Components
Ø.19 feed holes
Can mount air passage on either side. Receiver with air passage and without P.O check – Mtg. hole pattern
(3) 5/16–18 x .62"
*3.75
Ø.19 feed holes
(2) Ø.25 feed holes Ø.188 x .31"
.37
.37
1.47
.31
(2) #10–24 x .50
2.53
.94
.47
1.00 2.00
1.69
MCR-21 with MCRA-11
Can mount air passage on either side.
* Minimum from edge of tool plate
170
®
Mounting patterns, dimensions & options MCSB-21
MCR and MCS-series Max. Flow: 4 GPM
Storage Block – Mounting Hole Pattern
Pressure: 0-5000 psi 2X Ø.04 x .62"
E Acopladores manuales
1/4–20 x .50"
F Manuel coupleur
2.00
.75
1.81
D Manuelle kupplung
Options
Manifold and Port Dimensions (2) 1/16-27 NPTF dry seal taper pipe plugs (provided). Remove when manifold mounting.
4.00 .75
2.00 B
FZ Series fittings
194 ▸
.53
Hoses and couplers
.44
.63
A
.53
1/16-27 NPTF dry seal taper pipe plugs (provided). Remove when manifold mounting.
(2) O-rings (provided). Use when manifold mounting
O-ring (provided). Use when manifold mounting.
(2) Ø.25 feed holes
(2) Ø.19 feed holes
192 ▸ Pilot operated check valves
153 ▸
Rear view
(2) .56
Accumulators (6) Port passages SAE #4 plugs (provided) Accumulator or gauge port only SAE #4 plug (provided)
162 ▸ (4) Port passages SAE #2 plugs (provided)
Top view
A
Important
Do not couple or uncouple with the hydraulic nozzles under pressure. This can damage the couplers.
AIR
Do not exceed maximum flow and pressure.
System components
B
Pallet components
.51
Bleeder port only SAE #2 plug (provided)
Yellow pages
www.enerpacwh.com
®
171