Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

LPX SERIES-High Rate / UPS LPX12-7.0 (12V7.0AH) Specification Nominal Voltage 12V Watts(15min Rate) 28.4 Watts at 1.67V/cell Dimension Length Width Container Height Total Height (with Terminal) 151 65 94.5 100 1mm (5.95 inches) 1mm (2.56 inches) 1mm (3.72 inches) 1mm (3.94 inches) Ma int en an ce -fr LP X1 2- ee Se ale d O erate . T1 / T2 Container Material ABS Rated Capacity 7.20 AH/0.72A 7.00 AH/0.875A 6.40 AH/1.28A 5.97 AH/1.99A 5.91 AH/5.91A .0 AH ) ssem ble, MH2 6866 Approx 2.5 kg (5.51lbs) Approx Weight Terminal 7. 0( 12 V7 CO NS Le ad -ac TA NT VO id Ba tte Sta ndb LTAG E y ry CH AR use : GE Cy cle 13. 5-1 3.8 use : Init ial 14. 4-1 5.0 V cur ren t: Warn ing: Risk of Les s tha V fire, expl heat abov osio n, n or burn e the 50 2.1 A C, or incin s. Do not disa LEOCH BATTER MADE IN Y CO.,LTD. CHINA (10hr ,1.80V/cell,250C/770F) (8hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Non-s BATTERY MUSTpillable BE RECYCLED Application Applications UPS (High rate) High power backup supply Max. Discharge Current 105A (5s) Internal Resistance Approx 20mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Emergency power supply Starting system Power tools Emergency lighting 30C (77 50F ) Electric starting Initial Charging Current less than 2.1A.Voltage Cycle Use 14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C No limit on Initial Charging Current Voltage Standby Use 13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C 103% 40o C (104o F) o o 100% 25 C ( 77 F ) o o 86% 0 C ( 32 F ) Leoch LPX series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 22.6 15.1 11.7 10.2 8.33 5.99 4.79 2.62 1.81 1.42 1.19 1.01 0.826 0.689 0.387 1.80V/cell 26.4 17.2 12.9 11.0 8.93 6.52 5.11 2.77 1.95 1.51 1.25 1.08 0.875 0.720 0.390 1.75V/cell 29.8 18.8 14.1 11.7 9.28 6.77 5.34 2.87 1.99 1.54 1.28 1.11 0.896 0.738 0.393 1.70V/cell 32.9 20.6 15.0 12.3 9.70 7.03 5.52 2.99 2.07 1.60 1.32 1.13 0.912 0.745 0.401 1.67V/cell 36.2 22.2 15.9 13.1 10.2 7.22 5.70 3.07 2.13 1.64 1.35 1.14 0.930 0.761 0.406 1.60V/cell 40.0 23.7 16.8 14.0 10.8 7.52 5.91 3.17 2.19 1.70 1.38 1.17 0.943 0.768 0.409 10h 20h Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 1.85V/cell 41.4 28.0 21.8 19.1 15.9 11.5 9.24 5.08 3.55 2.79 2.38 2.02 1.62 1.37 0.768 1.80V/cell 47.8 31.3 23.7 20.3 16.8 12.4 9.80 5.34 3.80 2.97 2.47 2.13 1.71 1.43 0.774 1.75V/cell 52.8 33.9 25.5 21.6 17.3 12.8 10.2 5.53 3.86 3.03 2.53 2.19 1.75 1.46 0.780 1.70V/cell 56.6 36.1 26.9 22.5 17.8 13.3 10.5 5.73 4.00 3.13 2.60 2.23 1.78 1.46 0.794 1.67V/cell 61.5 38.6 28.4 23.8 18.7 13.5 10.8 5.86 4.10 3.20 2.64 2.27 1.80 1.49 0.804 1.60V/cell 66.3 40.2 29.3 25.0 19.6 14.0 11.1 6.02 4.22 3.29 2.70 2.32 1.82 1.51 0.807 1 Dimensions T1 Terminal LPX12-7.0(12V7.0AH) 100 1 94.5 1 4.75(0.187) 65 1 43 1 Unit: mm [inches] Maintenance-free Sealed Lead-acid Battery CONSTANT VOLTAGE CHARGE Standby use: 13.5-13.8 V Cycle use: 14.4-15.0 V Initial current: Less than 2.1 A Warning: Risk of fire, explosion, or burns. Do not disassemble, heat above the 50 O C, or incinerate. 3.2(0.126) MH26866 Non-spillable BATTERY MUST BE RECYCLED LEOCH BATTERY CO.,LTD. MADE IN CHINA 151 1 6.35(0.25) 0.8(0.031) Discharge Characteristics Float Charging Characteristics 6V Battery12V Battery V V 13.0 6.5 Charge Volume 0 Temperature:25C Terminal Voltage(V) 6.0 12.0 5.5 11.0 Charging Current (A) % Charging Voltage 120 0.10C 2.4 100 0.08C 2.3 80 0.06C 2.2 60 0.04C 2.1 40 0.02C 2.0 20 0C Charged Volume 0.22C 0.103C 0.054C 0.76C0.4C 5.0 Charge Voltage (Constant 2.25V/cell) 1.5C 10.0 After 50% Discharge 2.4C 4.5 9.0 4.0 8.0 4C 7C 10C 1 2 4 6 810 S 40 60 20 After 100% Discharge 5C 2 4 Charging Current 6 8 10 min 20 40 60 2 4 6 8 10 H 20 0 Discharge Time 8 12 16 20 24 28 32 36 Effect of Temperature on Long Term Float Life 120 12 100 10 8 5C 0.1 2 C 0.2 8 80 4 Charging Time(Hours) Temperature Effects in Relation to Battery Capacity Capacity (%) 0 0.1CA-2.25V/cell temperature25C (V/cell) Charging voltage : 2.25V/cell 5 3 60 1.0C 40 2 2. 0 C 20 0 -20 0 -10 0 10 30 20 40 20 68 50 Temperature( 0C ) 40 104 50 0C 122 OF Battery temperature 100 100C Remaining Capacity(%) 30 86 Self Discharge Characteristics A 80 250C 60 B 300C A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 0 40 C 40 C 20 0 0 2 6 4 8 10 Storage Time(Months) 12 Sales Office China sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:[email protected] Http://www.leoch.com Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail: [email protected] Http://www.leoch.us Add: 9B Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 729428 Fax: +44 (0)1452-690125 E-mail: [email protected] 2