Transcript
User Instruction Document number: 95-130850
Date: February 2010
System 5000 MF/HF Profiling Tool version 2 Installation and User Instruction The System 5000 Profiling Tool is an application program by which the serial number of System 5000 MF/HF 150W, 250W or 500W transceiver unit (TU) may be uploaded and stored electronically in the transceiver unit. Uploading of the serial number to the transceiver unit is required when having replaced the Control/Interconnection Module of the transceiver unit during e.g. an onboard service attendance. The presence of the serial number in the transceiver is essential for the reenabling or future enabling of DSC (6Ch. Watch Receiver) option and/or Telex option. The Profiling Tool may also be used to program option keys (pin codes) or read out already programmed option keys.
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 1 of 9
Document number: 95-130850
System 5000 MF/HF profiling tool operation Content: 1 2 3 4 5
1
Download and installation procedure Connecting to CU for pin code read out CU – pin code programming Connecting to TU for S/N read out Connecting to TU for S/N programming Download and installation procedure
Access the eSupport download site: http://esupport.thrane.com/index .php?loginresult=1&group=defa ult&loginresult=1&group=defau lt&group=default Select >Downloads<
Select: MF/HF/System5000/ Software/MF/HF5000-Profiling tool software: http://esupport.thrane.com/index .php?_m=downloads&_a=viewd ownload&downloaditemid=114 5&nav=0,202,205,292,293
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 2 of 9
Document number: 95-130850
Save the file to the PC harddrive
Extract folder and activate the > ProfilingTool.exe<
Click Run to install the SW
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 3 of 9
Document number: 95-130850
Select com port
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 4 of 9
Document number: 95-130850
2
Connecting to CU for pin code read out
Connect the service cable – S-532506 MF/HF Download Cable – to CU at the >Data< port. MF/HF Download Cable available here: http://shop.thrane.com/01_0124_012405MF_HF_Down_load_Cable-C3304-P23485.aspx
Select Unit type “CU” and press “Get Info” to establish connection between PC and Control Unit (CU)
To save the Telex Key and DSC Key (pin codes) read out to the PC, press the “floppy disk” icon
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 5 of 9
Document number: 95-130850
3
CU – pin code programming
NOTE: Telex and DSC Keys can only be programmed via the Control Unit (CU)
Select Unit type “CU” and press “Get Info” to establish connection between PC and Control Unit (CU)
Type the applicable pin code(s) into the appropriate field and press >Program< to store pin code(s) to TU.
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 6 of 9
Document number: 95-130850
NOTE: Main Processor & Interconnection Boards already programmed with a TU S/N are blocked for further programming.
4
Connecting to TU for serial number read out
Connect the service cable – S-532506 MF/HF Download Cable – to TU at the >SYS< port. MF/HF Download Cable available here: http://shop.thrane.com/01_0124_012405MF_HF_Down_load_Cable-C3304-P23485.aspx
Select Unit type “TU” and press “Get Info” to establish connection between PC and Transceiver Unit (TU)
If the TU s/n read out shows all zeroes or otherwise does not match the s/n stated on type label, the electronically stored s/n is invalid. This implies that the applicable Telex and DSC Keys cannot be generated and used for activation of these options in the unit.
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 7 of 9
Document number: 95-130850
5
Connecting to TU for serial number programming
TU s/n programming will only be possible in new or reconditioned ‘Main Processor & Interconnection Boards’ as delivered from T&T (s/n value not set)
Change unit type to “TU” Press >Get Info < Check that the “Serial Number” field is empty Check info window to verify that Serial Number and DSC Class are both indicated as “Not set”
Set >DSC Class< to “A”. NOTE 1: comprise functionality restricted to only.
DSC Class E reduced DSC and approval is certain markets
Type in serial number as stated on the TU type label. NOTE 2: Once programmed both the DSC class selection and serial number entry cannot be changed. Therefore, make sure these settings are correct before storing the entries to the TU. Press >Program<
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 ·
[email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46
Page 8 of 9
Document number: 95-130850
Check and verify the programmed values by pressing >Get Info<
Check software versions to be the latest. If this is not the case download latest software package from the eSupport download site: http://esupport.thrane.com/index.php?_m=downloads&_a =viewdownload&downloaditemid=789&nav=0,202,205,2 92,293
Software details
NOTE: Software version must be same for both CU and TU
Thrane & Thrane Customer Service
Author:
Date:
Checked:
Date:
Approved:
Date:
27-01-2010
JKR
15-02-2010
DAV
15-02-2010
Thrane & Thrane A/S · Lundtoftegaardsvej 93 D · DK-2800 Kgs. Lyngby · Denmark T +45 39 55 88 00 · F +45 39 55 88 88 · [email protected] · www.thrane.com Bank: Danske Bank · Comp.reg.: 65 72 46 18 · VAT: DK-20 64 64 46