Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

QUICKSTART “BASIC” GUIDELINES FOR STANDARD MODEL 6050/6100 - FOR GATES UP TO 10 FEET AND OPENING 90° Models 6050/6100 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. 120 S. Glasgow Avenue Inglewood, California 90301 For safety and installation instructions, please refer to the Installation/Owner’s manual. U.S.A. Gate Bracket Open Gate e at Br t ke ac e as Chassis Ground e at G t ke ac Br Sh A ow ad .5” Lo Important: The elbow assembly must be in the correct position on the arms BEFORE cycling operator the first time. op 4” 24 ” 23” Elbow Flange B Output Shaft 10” 18.5” 14” Right Support Leg Open Gate Open Gate Left Support Leg Concrete 12” Post Base 10” Conduit 2.5” 12” 3” Output Shaft Position 22” Concrete Pad Pad MUST be Level. 24” 3/8 Secure operator to the concrete pad with four (4) 3/8” x 3” sleeve anchors (not supplied). ACwer Ponduit Co uit p Loo nd Co 1 we rA rm Crank Power Arm will remain stationary during manual gate movement. 2 Manual Release Arm Assembly and Gate Bracket Height the of is h pt e De ncret by o c ined s rm ition e t de cond ocal l l soi and des. o gc ldin i u b c Jun ith ”w 3/4 eeps Sw s oxe B tion Po Arms and Operator MUST be level. Gate Bracket 30” Crank Arm 5” Flange 60” Connecting Arm Varies with base used. Ground Copyright 2016 DoorKing, Inc. All rights reserved. Brass Bushing Elbow Assembly Crank Power Arm Important: Adjust the locknut on the crank power arm so that it is snug against the washer, but will still allow the 30” crank arm to rotate with little force. B 3. OFF 4. ON 5. OFF 6. OFF 7. ON (Single Operator) 8. ON (Tamper Protect) SW 3 ON Run conduit on the opposite side of the open gate for the post base. 3” n Co nk 1 2 3 4 5 6 7 8 Post Base MUST be Level. Pad Base B Pla le igh xib it HVolt e l F du m 2” Conduit 6” m o ott f te o w Lo lt Vo 0 630 Cra Ar Post Base 24” 43” D k 26” 43” A an Note: 2” thick gate Illustrated. 7 Cr Mount the post base into the concrete before installing the operator. 90° • NO AC power. • NO DC power (On select models). 0 #2 to #11 m Co to 7 1. elay t to # R l . 2 4 Vo 2 3. C Closed Gate 90° 11 ON 20 Using shadow loop and gate opening in direction shown. SW 4 Auto Close 1. OFF Timer 2. OFF 1 2 3 4 5 6 7 8 Output Shaft Concrete Position Closed Gate High Voltage Conduit DIP-Switch Settings Safety Cover Elbow Assembly Important: Elbow flange MUST be on the opposite side of the closed gate. Manually adjust the arms to get the correct open and closed positions BEFORE powering up the operator. Open/Close limits will be automatically set the first time operator is cycled. 115 VAC HIGH VOLTAGE! G B st Po 43” 37 Important: A straight line drawn from the closed gate bracket through the open gate bracket MUST intersect the operator output shaft. DANGER se Ba Note: 2” thick gate Illustrated. D d Pa 90° Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. 115 VAC Closed Gate GATE OPERATOR MUST BE PROPERLY GROUNDED!! Neutral 12” op Lo 34” High Voltage Connection se er ev R Operator Position Adjust 1 to 23 sec. 1. OFF (Opening Counter-Clockwise) 2. OFF 3. OFF 4. OFF 5. OFF (Normal Reverse Function) 6. OFF 7. CLOSE Photo Beam REQUIRED 8. OPEN/CLOSE Edge/Beam (See other side) Loop Detectors C Not included - Refer to the Installation/Owner’s manual and Loop Information Manual (available FREE from www.dkaccess.com) for more information on loops and loop detectors. Radio Receiver D Not included - Refer to a specific Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. (See reverse side for wiring) 6050-066-G-2-16 QUICKSTART “BASIC” GUIDELINES FOR MODEL 6050/6100 - DIP-SWITCH AND WIRING REFERENCE Model 6050/6100 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. #11 - Access Control Devices For safety and installation instructions, please refer to the Installation/Owner’s manual. ON 1 2 3 4 5 6 7 8 3 Exit Loop Port Output Full Open Input 6 Auto-Close Timer Not Used 3-Button Single Button 7 Dual Operators Single Operator 8 Tamper Protect 4 5 OFF ON OFF ON OFF OFF ON OFF ON OFF ON Description Relay activates when gate is open (Shadow loop setting when used). Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates when gate is opening and closing. The output wired to terminal #12 becomes the output from the exit loop detector plugged into the EXIT Loop port. Normal Setting. Terminal #12 is a normal full open input. Auto-close timer is OFF. Manual input required to close gate. Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. Leave in the OFF position. OFF when using a 3-button station (DoorKing 3-button control stations only). ON when using a single button control, terminals 13 &14 become a STOP input. Switch must be OFF when bi-parting (dual) gates are used. Switch must be ON for single operator. Tamper protect is OFF. Normal Setting. Tamper protect is ON. Operator will close gate when being forced open. Every time the operator is powered up, the First open command will automatically set the open and close limits of the gate. Switch Function Setting Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect. SW 3 (Bottom 8 Switches) Telephone Entry 1 Important: Controls must be installed Stand-Alone Card Reader ON 1 2 3 4 5 6 7 8 2 Secondary Gate Opening Direction 3 Not Used 4 Motor Control for Secondary Operator 5 Reverse Shadow Loop 6 Gate Overlap 7 Monitored Close Beam Monitored Edge/Beam 8 #12 - Safety Opening Device OFF ON OFF ON Switch is OFF when both primary and secondary operator motors are powered from main terminals 4 and 5. Applies to operators originally manufactured with 4501, Rev O boards or lower). Switch is ON when secondary operator motor is powered from the secondary motor terminals. Applies to operators manufactured with 4501, Rev P boards and higher, and all 4502 boards. Terminal 15 is a STANDARD Reverse input. Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle. Primary and secondary operators start at the same time. Secondary operator starts 1-2 seconds prior to primary operator. OFF ON OFF ON No Photo Sensor connected to Aux terminal 7 and 8. Photo sensor is connected to Aux terminal 7 and 8 and monitored. (Close ONLY) No Edge or Beam connected to Aux terminal 9 and 10. Edge OR Beam is connected to Aux terminal 9 and 10 and monitored. (Open/Close) OFF ON DoorKing ONLY Com Com CLOSE Beam Same as above, for secondary 6050/6100 ONLY. Leave in OFF position. 3-Button Station 1 amp max. 24 Volt SW 4, switch 3 must be ON. OFF White Com Potential Entrapment Area Normally Closed (N.C.) CLOSED gate Potential Entrapment Area: Potential Entrapment Area Installation of MONITORED entrapment protection is REQUIRED or operator will NOT function. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices. IMPORTANT: Photo sensors must use Normally Closed (NC) contacts with the beam set for light operate (relay activated when beam is not obstructed). Open/Close Edge 10 13 14 15 16 17 18 19 Com 13 20 Com 4502-010 KEY SWITCH DATA 11 12 14 15 NO NC 1 2 3 4 5 6 7 8 SW 3 OFF Power (24 Volt DC) and logic output. Power is shut off .5 sec. prior to gate starting and remains off while gate is opening and in the open position. 10 Access 11 Device Open 12 Safety Open ON ON Green Close Magnetic Lock 9 1 2 3 4 5 6 7 8 Opens Counter-Clockwise ON Opens Clockwise 1 2 3 4 5 6 7 8 1 Primary Gate Opening Direction Red Open 2 24 VAC Power ON SW 4 6 7 8 9 a minimum of 6-feet from the gate or installed in such a way that the person using the control cannot come in contact with the gate or gate operator. Stand-Alone Keypad 1 2 3 4 5 Key Switch Note: All stand-alone and telephone entry devices must use a separate power source. Description 24 Volt Circuit Board Relay U.S.A. 3-Wire Radio Receiver Limited to 250 ma. Relay 1 and 2 Setting 1-OFF 2-OFF 1-OFF 2-ON 1-ON 2-OFF 1-ON 2-ON SW 4 (Top 8 Switches) Com Function 120 S. Glasgow Avenue Inglewood, California 90301 Coax Antenna Kit P/N 1514-073 Aux Terminal Monitored CLOSE Beam Common Monitored OPEN/CLOSE Edge/Beam Common SW 4 Switch Antenna mounted outside operator cover. 7 8 9 10 CLOSE Photo Sensor 7&8 SW 3 switch 7 MUST be ON. Please refer to the Installation/Owner’s manual for complete installation instructions for entrapment protection devices. Open Photo Sensor 9&10...OR.... OPEN gate OPEN Beam SW 3 switch 8 MUST be ON. Normally Closed (N.C.) Mointored Sensor Note: Only 1 monitored Device can be connected to each input. .......Reverse Edge 9&10 SW 3 switch 8 MUST be ON. POWE