Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Data 111-7 1/30/2009 Eclipse Winnox Burners Model WX1000 Version 1 Parameter Specifications Blower Type Maximum Input, MMBTU/hr (kW) NOTE: Capacities given without air filter. Contact factory for chamber pressures outside the given range, or varying chamber pressure conditions. Minimum Input, BTU/hr (kW) Fuel Inlet Pressure at Ratio Regulator, psi (mbar)1 Packaged Blower Remote Blower Chamber Pressure "w.c. (mbar) Nominal (60Hz) Pressure at Air Inlet 1.5 psig (100 mbar) -5.0 (-12.5) 9.7 (2840) 13.6 (3985) -3.0 (-7.5) 9.2 (2694) 13.2 (3868) 0.0 8.5 (2490) 12.5 (3660) 1.0 (2.5) 8.25 (2416) 12.2 (3575) 2.0 (5.0) 7.98 (2337) 12.0 (3516) Natural Gas 300,000 (88) 300,000 (88) Propane, Butane 400,000 (117) 400,000 (117) Maximum 3.0 (207) 5.0 (345) Minimum 1.0 (69) 2.0 (138) Maximum Chamber Temperature, °F (°C) NOTE: Tube and plug temperatures should be reduced 150°F when using propane or butane. Standard combustion tube: 1100 (593) High temperature combustion tube: 1400 (760) Flame Length Flame is inside tube at all times. Excess Air,% at High Fire 40% - 70% Piping NPT burner piping available. Flame Detection Flame rod or UV scanner. Fuels Natural gas, Propane, Butane2 For any other mixed gas, contact Eclipse Inc. Weight, lbs (kg) 1435 (651) 1135 (515) Approvals 1 For proper performance, this pressure must be kept constant across the burner operating range. 2 See Design Guide for more information about typical fuel composition and properties. • All information is based on laboratory testing. Different chamber size and conditions will affect data. • Maximum inputs for packaged blower versions are given for the standard combustion air blower without an inlet air filter. • All inputs are based on gross calorific values and standard conditions: one atmosphere, 70°F (21°C). • Eclipse reserves the right to change the construction and/or configurations of our products at any time without being obliged to adjust earlier supplies accordingly. Performance Graphs Control Zone 800 600 300 500 20 CO ppm 400 15 300 200 10 NOX 250 200 150 100 100 0 CO 350 25 NOX ppm % Excess Air 400 30 700 NOX and CO Emissions (at 3% O2) 5 2 0 4 6 8 10 12 14 0 Input (MMBTU/hr) 0 50 0 0 Input (kW) NOTE: Input at low fire changes with ratio regulator adjustment. Secondary By-Pass Fuel Setting: Fuel ¨P "w.c. (mbar)* Natural Gas 4.0 (10.0) Propane 4.0 (10.0) Butane 4.0 (10.0) *Measured between Tap “E” and the chamber @ low fire. Fuel/Input Measurement System design must include fuel flow measurement upstream of the burner. Recommended is the Eclipse 125 FOM (Fuel Orifice Meter) assembly number 302050-5 for natural gas. See Bulletin 930 for details. 2 0 500 1000 1500 2000 2500 3000 3500 4000 4 6 10 8 Input (MMBTU/hr) 12 13 500 1000 1500 2000 2500 3000 3500 4000 Input (kW) NOX and CO emission data is given for: • Ambient combustion air (~70°F, 20°C) • Less than 1000°F (540°C) firing chamber • Minimal process air velocity • Low fire input adjusted to 300,000 BTU/hr (88 kW) • Neutral chamber pressure • Natural gas • 70% excess air Emissions are influenced by: • Chamber conditions • Fuel type • Firing rate • Ratio regulator adjustments • Combustion air temperature • Excess air CO emission is largely influenced by chamber conditions. Contact your local Eclipse representative for an estimate of CO emission on your application. NOTE: Insure burner inlet pressures are met. Air ∆P vs. Input (Measured Between Tap “C” and the Chamber) 40 100 75 50 25 Air ∆P ("w.c.) Air ∆P (mbar) 35 30 At low fire, air ∆P firing into neutral chamber is 0.3" w.c. (0.75 mbar) 25 20 15 10 5 0 0 0 2 4 6 8 10 12 13 Input (MMBTU/hr) 0 500 1000 1500 2000 2500 3000 3500 Input (kW) 2 Eclipse Winnox Model WX1000, V1, Data 111-7, 1/30/2009 Packaged Blower Dimensions in inches (mm) 23.4 (594) 22.7 (577) 35.7 (906) 39.7 (1010) 15.5 (394) Tap “C” UV Scanner Location 26.9 3" (683) NPT Tap “B” Ø29.9 (760) Tap “E” 4.6 (117.5) Ø33.3 (845.3) 7.8 (199) Ø30.1 (765) 8.2 (208) 8x Ø0.47 (12) on Ø32.02 (813.5) BC 34.6 (879) 27.6 (700) 17 (433) 35.6 (905) Remote Blower NOTE: For Remote Blower applications, consult factory. 1/4" Air Line* UV Scanner Location 12.9 (327) Ø12.75 (324) Welded Air Inlet 3" NPT Ø33.3 (845.3) 8x Ø0.47 (12) on Ø32.02 (813.5) BC 34.6 (879) 19.1 (487) 4.6 (117.5) 7.8 (199) 1/8" NPT Ø29.9 (760) Ø30.1 (765) 8.2 (208) 17 (433) 27.6 (700) 35.6 (905) * Recommended customer supplied 1/4" air line from upstream of the air control valve. Eclipse Winnox Model WX1000, V1, Data 111-7, 1/30/2009 3 Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com