Transcript
SPI-300
EN
HDMI V/A 1
V/A 1
8
9
STATUS
SYNC
+12V
+12V
USB
USB
LAN
LAN
LAN
Link
Act
STATUS
SDI
SDI
USB
DVB-T OUT
C
MHD-201
Ref. 3854 DIGITAL MODULATOR
CONTROL
7
AUDIO R
6
AUDIO R
5
SYNC
+12V
AUDIO L
4
AUDIO L
STATUS
SDI
V/A 2 VIDEO
SYNC
VIDEO
3
CONTROL
2
AUDIO R
AUDIO R
MHD-201
Ref. 3854 DIGITAL MODULATOR
CONTROL
1
V/A 1
AUDIO L
AUDIO L
MHD-201
Ref. 3854 DIGITAL MODULATOR
V/A 2 VIDEO
VIDEO
AUDIO R
AUDIO R
AUDIO L
AUDIO L
VIDEO
VIDEO
SPI-300
HDMI
HDMI
V/A 2
Link
Act
DVB-T OUT
Link
Act
DVB-T OUT
0
PROGRAMMING GUIDE FOR «MHD-201» MODULATOR CVBS; HDMI; HD-SDI DVB-T or IP
Programming MHD-201 Modules
Contents START SCREENS
1 - Module Basic Information.......................................................3
2 - Main Menus ............................................................................ 3 Overview Screen ..................................................................... 4 Settings screen......................................................................... 5 Info Screen................................................................................6 Language screen.......................................................................7 PROGRAMMING SCREEN 1 - General ................................................................................... 7 IP Date-Time 2 - Settings . ..................................................................................8 Input Output: 3 - USB Player . ...........................................................................11 Status Mode QUICK MENUS ............................................................................ 12-13
2
Programming MHD-201 Modules
START SCREENS 1 - Module Basic Information As described in Basic Handling guide supplied with the SPI-300, on connecting it to the module the identification data, settings and status of the module are loaded onto the remote. The module detection screen appears for a short time, and then the display shows the Basic Information screen, which contains its most representative data: The meanings of expressions and data presented are:
MDHD-201 F 02.18 CH 21 SYSTEM: OK OK Module name. F 02.18: Version of the module firmware (the firmware is software stored in the module that is responsible for its basic operation). CH 21: By default the output channel is 21. SYSTEM OK (status correct); NO IMPUT (no input signal is detected; SYSTEM NOK (status incorrect). Pressing the OK command (key ) takes us to the Main Menu Screen (Basic Handling Manual). 2 - Main Menus As indicated in the Basic Handling Manual, the General menu and Language are identical for all ClassA modules and their commands are described in it. Setting andInfoMenus include, however, options or information, unique to each module type.
3
Programming MHD-201 Modules
Main Screen GENERAL
1 General 2 Settings 3 Info 4 Language
SEL
The General menu is identical for all ClassA modules and the commands are the following:
1 Detect 2 Send 3 Update ESC
4 Recall 5 Save 6 Factory Reset ESC
SEL
SEL
7 About ...
ESC
SEL
• Detect: Runs the detection process of the connected module.
MDHD-201 F 02.18 CH 21 SYSTEM: OK
OK
• Send: Establishes on the module the parameter values that have been modified. • Update: This option does not apply to this model. The firmware update is performed only through the web interface (see manual www.ikusi.tv). • Recall: Returns the configuration of the module previously created with the Save command. This menu is useful to quickly load repetitive data in multiple modules. 4
Programming MHD-201 Modules
• Save: Saves the module configuration in the memory of the SPI-300 remote. • Factory Reset: Restores all parameter values that were set up in the module when it left the factory • About ... : Simply reports the firmware version of the SPI-300.
SPI-300 vXX.XX (DD/MM/YY) Copyright 2009 IKUSI OK Main Screen SETTINGS
1 General 2 Settings 3 Info 4 Language
SEL
The Settings menu contains all the setting parameters of the connected module. Grouped by sections or categories that are arranged in one or more screens:
1 Input 2 Output 3 Country ESC
SEL
SEL
4 Language 5 Advanced ESC
• Input: Select one of the input types available on the module. • Output: This menu quickly accesses the output channel (default channel 21) and attenuation in COFDM mode. • Country: Must be selected to have the specific configurations operating in each country such as the ONID or LCN mode. • Language: Enables one of the available languages to be selected. • Advanced: Should be selected to carry out module configuration operations (see detailed explanation later). 5
Programming MHD-201 Modules
Main Screen INFO
1 General 2 Settings 3 Info 4 Language
SEL
The Info menu provides access to detailed information about the connected module, regardless of whether it has been programmed or not.
1 Status 2 Alarm 3 Details ESC
SEL
• Status: Informs about the operating conditions of the module. CH1 VID: Reports the existence or not of a valid video signal. CH1 AUD: Reports the existence or not of a valid audio signal. Player: Reports the operation of the USB channel. % Free: The middle number expresses the percentage of null PIDs (no information) that are currently in the output stream; the higher the number, the less risk there is of overflow (in other words, less risk of data loss). The numbers on the left and the right are respectively the minimum and maximum values that have been reached over the period of operation of the module, since the last power connection. Bitrate: Reports the data encoding speed on output. IP Bitrate: Reports the data encoding speed on output. Num Str: Reports the number of services.
• Alarm: Reports whether there is an alarm active on the module and what type it is. HW: Displays error if a problem has been detected in the hardware. In: Displays error if an HD input is inserted in an SD input. Cod: Displays the status of MPEG encoder. Sl: Displays the status of the DVB signalling. Mod: Displays error if there is any problem with the DVB-T output. IP: Displays error if there is any problem with the IP output. Sync: Displays error if there is a problem of synchronisation.
• Details: Identifies the module and displays relevant data about it. HW: Displays the hardware version of the module. SW: Displays the software version of the module. BS: Displays the Bootstrap version. SERIAL: Displays the serial identification number of each module. MAC: Displays the number that identifies each module for networking. 6
Programming MHD-201 Modules
Main Screen LANGUAGE
1 General 2 Settings 3 Info 4 Language
SEL
Select here the language you want to operate in from now on. Position the cursor in the "Spanish" line and press the button .
PROGRAMMING SCREEN In the next part of this manual, the commands to configure the module will be explained. From SETTINGS on the Main screen move to the ADVANCED submenu which shows the following parameters:
1 General 2 Settings 3 USB Player ESC
SEL
1 - GENERAL : Select this menu to access the following submenus:
1 IP 2 Date-Time ESC
SEL
IP: Indicates the factory set IP address parameters .
1 IP: 2 MR: 3 GW: SEND
192.168.1.6 255.255.255.0 192.168.1.1
SEL
7
Programming MHD-201 Modules
• IP Address: Static IP address within the valid range of the local network to which the module is connected. • Network Mask: Local network mask. • Default gateway: IP address of the default gateway on the local network to which the module is connected. Date-Time: Displays data regarding time zone, date and time. Automatically it presents the time zone depending on the country which has been entered.
1 Time: 10.19 2 Date: 21.03.201 3 Time Zone: Europe / Madrid SEND SEL 2 - SETTINGS : Select this menu to access the following parameters:
1 General 2 Settings 3 USB Player ESC
1 Input 2 Output SEL
ESC
SEL
Input: Select one of the possible input combinations and the corresponding parameters: 2 SD [CVBS+CVBS] ; 2 SD [HDMI+CVBS] ; 2 SD [SDI+CVBS] ; 1 HD [HDMI] ; 1 HD [SDI] 1 Input type SD SDI + CVBS 2 Aspect 1 16:9 3 Codec 1: MPEG2 4 Bitrate Vi 1 : 8000 5 Bitrate Au 1 : 384 6 Low latency 1 : OFF 7 Aspect 2 --8 Codec 2: --9 Bitrate Vi2 : --A Bitrate Au 2: --B Low latency 2: v --SEND 8
SEL
Programming MHD-201 Modules
Aspect: Enables the image format to be selected, 16:9 or 4:3. odec: Enables the encoding standard of the digitized audio and video signal to be selected from the options: MPEG2 and MPEG4 (if the input signal is SD, the default will encoding will be MPEG2, if the signal is HD, encoding is H.264 (1080p resolution only supports MPEG4). Bitrate Video: (4-10 Mbits / s): The device can be configured for an input data encoding rate from 4 to 10 Mbits/s. When selecting the encoding bitrate, the COFDM output bitrate must be taken into account, this should be sufficient to support the encoding bitrate, in the opposite case the overflow alarm appears. Bitrate Audio: The device can be configured for an input data encoding rate of 96; 128; 160; 192; 224; 256; 320 and 384 Kbits/s. Low latency: Reduces encoding time for applications where response time is important (e.g. cameras). Selecting the low-latency mode, has on the other hand decreased coding efficiency and image quality with a lot of movement.
Output: The MHD-201 modulator has two output types CODFM and IP. Using the SPI-300 control only the first option can be configured, to select the IP mode output use the web interface (see manual www.ikusi.tv).
1 COFDM output 2 Service 1 3 Service 2 ESC
SEL
• COFDM output: Select this option to specify the RF and Network Configuration data.
1 RF Configuration 2 Network ESC
SEL
• RF configuration: Select this option to specify the following output parameters. 1 COFDM output 2 Channel: 3 Frequency: 4 Attenuation: 5 Mode : 6 Band Width: 7 Guard Int.: 8 Constell. . 9 Code rate : SEND
21 474.000 00.0 dB 8K 8MHz 1/32 64QA 7/8 SEL
9
Programming MHD-201 Modules
Channel: Enables the output channel to be selected and modified. Frequency: Reports on the output frequency of the current radio frequency carrier and enables its value to be modified. The frequency value must lie within the valid range for VHF and UHF bands. Attenuation: Allows attenuation for the RF carrier signal to the output to be configured, varying this value in the range of 0 dB to 25 dB. COFDM mode: Allows the OFDM mode to be configured, selecting 2K and 8K values. Bandwidth: Allows the bandwidth to be configured selecting the values 6, 7 or 8 MHz Guard interval: allows the guard interval to be configured by selecting 1/4, 1/8, 1/16 or 1/32 symbol. Constellation: enables the output modulation constellation to be configured by selecting from the options 16QAM or 64QAM. Code rate: enables the redundant encoding rate to be configured selecting the values 1/2, 2/3, 3/4, 5/6 or 7/8.
• Network: Within this sub-data the data of the following parameters can be configured: 1 Name.: 2 Provider: 3 NID: 4 TSID: 5 ONID: 6 NIT mode: 7 NIT LCN: 8 Ins TDT-TOT : SEND
Standard IKUSI 00001 00021 00100 ON OFF ON
SEL
Network Name: Assigns a name to the network. Provider: Enables the name of the service provider to be specified. NID: Enables a value to be assigned to the network identifier. TSID: Enables a value to be assigned to the identifier of the transport stream or TS. NOTE. For a headend configuration with 2 or more devices, the TSID value must be different for each device. ONID: enables a value to be assigned to the original network identifier. NIT mode: OFF an LCN descriptor is not inserted in the NIT . NIT LCN: Enables the LCN mode of the NIT to be selected. Europe Mode: Europe descriptor is inserted. Independent Television Commission: UK descriptor to be inserted. Nordig mode V1: Descriptor is inserted according to the Nordig V1 specification. Nordig V2 mode: Descriptor is inserted according to the Nordig V2 specification. Generic Mode: Generic LCN descriptor. Insert TDT-TOT: Enables information on the date and time to be inserted or not.
10
Programming MHD-201 Modules
• Service: Depending on whether the Input configuration is in HD or SD mode we can have one or two services respectively. 1 Service 1 2 Video 1: 3 Audio 1: 4 LCN 1: 5 SDI 1: 6 Name 1: SEND
ON ON 1 21 MAC SERV1
SEL
Video: Enables the video signal of a service to be activated. Audio: Enables the audio signal of a service to be activated. LCN: Displays the logical channel number. SID: Enables the ID that is assigned to a service to be assigned, modified and identified. The SID value is important for the detection of channels in some receivers. All SID values must be different for the group of services processed by one or more devices that contribute to a common RF output. Name: Enables an identifying name to be assigned to each service.
3 - USB Player : The modulator allows video to be played through the USB port. By means of an application, the user can customise a list of images and videos to create a final file ("video-final.ts") capable of being reproduced as a proper channel.
1 General 2 Settings 3USB Player ESC
SEL
1 Status STOPPED 2 Mode : OFF
SEND
SEL
• Status: Reports whether the channel is in USB playback mode or not. STOPPED: Playback paused. PLAYING: Playing on. USB ERROR: USB not detected. ERROR FILE: The final file is not correct.
• Mode: Enable / disable play ON / OFF .
11
QUICK MENUS
1 General 2 Settings 3 Info 4 Language
SEL
MDHD-201 CH 21 SYSTEM:
1 Detect 2 Send 3 Update (only via web) ESC
SEL
4 Recall 5 Save 6 Factory Reset ESC
SEL
OK
1 configuration: 0001 2 See 3 Clear SEND
SEL
SPI-300 vXX.XX (DD/MM/YY) Copyright 2009 IKU SI OK
7 About ...
ESC
F 02.18
SEL
1 Input: SD SDI + CVBS
SEL
ESC
1 COFDM output 1 Input 2 Output 3 Country ESC
SEL
SEND
SEL
1 Status 2 Alarm 3 Details
SEND
SEL
SEL
• English French Spanish Italian
1 IP 2 Date-Time SEL
CH1 VID: X Not detected AUD: X Stereo CH2 VID: X Not detected AUD: X Stereo OK
ESC
1 Input 2 Output ESC
Player. STOPPED % Free: 00 <00 <00 Bitrate: 00.000MbpS IP Bitrate: 00.000MbpS Num Str: 1 HW: 0 In: X Cod: X Yes: X Mod : 0 IP: 0 Syn: X
12
21 0dB SEL
SEL
1 Language: English
1 General 2 Settings 3 USB Player ESC
ESC
1 Channel: 2 Attenuat. : ESC
1 Country: UK
4 Language 5 Advanced ESC
SEL
ESC
1 Status STOPPED 2 Mode : OFF OK
STOP
MHD-201 HW: 01.00 SW: 02.18 BS: 01.00
OK
SERIAL: 385433545676 MAC: 0009E3545676
OK
SEND
1 IP: 192.168.1.6 2 MR: 255.255.255.0 3 GW: 192.168.1.1 SEND
SEL
1 Time: 10.19 2 Date: 21.03.201 3 Time Zone: Europe / Madrid SEND SEL
SEL
SEL
SEL
1 Input type SD SDI + CVBS 2 Aspect 1:16:9 3 Codec 1: MPEG2 4 Bitrate Vi 1 : 8000 5 Bitrate Au 1 : 384 6 Low latency1 : OFF 7 Aspect 1 --8 Codec 2: --9 Bitrate Vi2 : --A Bitrate Au2: --B Low latency2: --SEND SEL 1 COFDM output 2 Service 1 3 Service 2 ESC SEL
1 COFDM output 2 Channel: 21 3 Frequency: 4 Attenuation: 5 Mode : 8K 6 Band Width: 7 Guard Int.: 8 Constell. . 9 Code rate : SEND
1 RF Configuration 2 Network
SEL
ESC
1 Service 1 2 Video1: 3 Audio1: 4 LCN1: 5 SDI1: 6 Name 1: SEND
OFF OFF 1 42 TEST1
1 Name.: Standard 2 Provider: 3 NID: 4 TSID: 00021 5 ONID: 00100 6 NIT mode: ON 7 NIT LCN: OFF 8 Ins TDT-TOT : SEND SEL
474.000 00.0 dB 8MHz 1/32 64QA 7/8 SEL
IKUSI 00001
ON
SEL
1 Service 2 2 Video2: OFF 3 Audio2: OFF 4 LCN2: 2 5 SDI1: 43 6 Name 2 MAC SERV2 SEND SEL
13
Ángel Iglesias, S.A. Paseo Miramón, 170 20014 San Sebastián, Spain Tel +34 943 44 88 00 Fax +34 943 44 88 20
[email protected] www.ikusi.tv
SPI-300 / MHD-201 (v.A) (EN)