Regulator R1000/R3000/R4000/R8000 Series Compact pressure gauge integrated type Port size: Rc1/8 to Rc1 JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R1000 R3000 R4000 R8000 Appearance Working fluid Compressed air Max. working pressure MPa 1.0 Withstanding pressure MPa Working temperature Set pressure range 1.5 °C 5 to 60 MPa 0.05 to 0.85 Relief With relief mechanism Port size Rc 1/8 and 1/4 (use an adaptor for 3/8.) 1/4 and 3/8 (use an adaptor for 1/2.) 1/4, 3/8 and 1/2 (use an adaptor for 3/4.) 3/4 and 1 (use an adaptor for 1 1/4.) Product mass kg Standard accessories 0.16 0.45 Nut for pressure gauge and panel mount 0.7 1.6 Pressure gauge Regulator F Flow characteristics • R1000-6 • R1000-8 Refrigerating type dryer • R3000-8 Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 0 0.5 1.0 1.5 Secondary pressure (MPa) 0.6 Secondary pressure (MPa) Secondary pressure (MPa) Desiccant type dryer Primary pressure 0.7MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 1.0 2.0 3.0 Primary pressure 0.7MPa 0.6 Air filter 0.4 Automatic drain other 0.3 0.2 0.1 F.R.L (Module) 0 0.5 Air flow rate (m3/min (ANR) ) Air flow rate (m3/min (ANR) ) High polymer membrane dryer 0.5 1.0 1.5 2.0 2.5 Air flow rate (m3/min (ANR) ) F.R.L (Separate) Small F.R. Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 0 1.0 2.0 3.0 4.0 5.0 Primary pressure 0.7MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 0.5 1.5 2.0 2.5 0.6 Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 1.0 2.0 3.0 Electro pneumatic R. Primary pressure 0.7MPa 0.5 Auxiliary 0.4 Flow control valve 0.3 0.2 Silencer 0.1 0 1.0 4.0 Air flow rate (m3/min (ANR) ) 5.0 3.0 4.0 5.0 0.6 0.5 0.4 0.3 0.2 0.1 2 4 6 8 10 12 14 Vacuum F. Vacuum R. Primary pressure 0.7MPa Vacuum generator 0.6 0.5 Vacuum auxiliary / pad 0.4 0.3 Mechanical pressure SW 0.2 0.1 0 2 4 6 8 10 12 14 Air flow rate (m3/min (ANR) ) Air flow rate (m3/min (ANR) ) 0.24 0.22 0.2 Set pressure 0.18 0.16 0.2 0.4 0.6 0.8 Primary pressure (MPa) 0.22 0.21 0.2 Set pressure 0.19 0.18 0.2 0.4 0.6 Primary pressure (MPa) 0.8 Pressure SW for coolant 0.21 Flow sensor for air 0.2 Total air system Set pressure 0.19 0.18 0.17 0 0.2 0.4 0.6 0.8 Primary pressure (MPa) 1.0 Water cooling refrigerator Flow sensor for water F.R.L. unit Regulator • R8000 Secondary pressure (MPa) • R4000 Secondary pressure (MPa) Secondary pressure (MPa) Secondary pressure (MPa) • R3000 Electronic pressure SW Electronic dif. pres. SW Seating / close contact conf. SW Pressure characteristics • R1000 Check valve / others Joint / tube • R8000-25 Primary pressure 0.7MPa 0 2.0 Air flow rate (m3/min (ANR) ) • R8000-20 Secondary pressure (MPa) Secondary pressure (MPa) • R4000-15 0 1.0 Precise R. 0.6 Air flow rate (m3/min (ANR) ) Air flow rate (m3/min (ANR) ) Secondary pressure (MPa) 0.6 • R4000-10 Secondary pressure (MPa) • R4000-8 Secondary pressure (MPa) Secondary pressure (MPa) • R3000-10 0.21 0.2 Set pressure 0.19 0.18 0.17 0.2 0.4 0.6 0.8 Primary pressure (MPa) Regulator Series How to order A Model Symbol B B Port size C C Option Note 1 Note 2 Note 3 Note 4 * Refer to Page267 for explanation on options. Attachment Note 5 Note 6 Note on model No. selection Note 1: When selecting multiple options, write them from the top. Note 2: If "L" is selected for pressure range, a low pressure gauge (0-0.4MPa) is provided. Note 3: For "T", a gauge plug is assembled instead of a pressure gauge. Note 4: Refer to Page 259 for "R1" details. Working temperature range is 5 to 50 °C. Note 5: A piping adaptor set A*00-** (refer to Page 586) is attached. Note 6: Refer to " auxiliary components " (Page 557 to) for attachments. Also, piping adapter set and C type bracket can not be used together. 6 Rc1/8 8 Rc1/4 10 Rc3/8 15 Rc1/2 20 Rc3/4 25 Rc1 Option Pressure Blank L range Blank Relief N Blank 0.05 to 0.85MPa 0.05 to 0.35MPa With relief mechanism Non-relief type With standard pressure gauge (G401) Pressure T gauge T8 Round shaped pressure gauge attached (pressure gauge port is assembled in open state.) R1 Pressure switch with display PPD assembly D D Descriptions Port size Without pressure gauge (gauge port is assembled in sealed state.) X1 IN / OUT reverse flow (right → left) P11 Ozone proof specifications (custom order) Attachment (attached) A6 Rc1/8 piping adapter sets A8 Rc1/4 piping adapter sets A10 Rc3/8 piping adapter sets A15 Rc1/2 piping adapter sets A20 Rc3/4 piping adapter sets A25 Rc1 piping adapter set A32 Rc1 1/4 piping adapter sets B C type bracket B3 L type bracket G49P Pressure gauge: G49D-8-P10 G59P Pressure gauge: G59D-8-P10 G40P Pressure gauge: G40D-8-P10 G50P Pressure gauge: G50D-8-P10 G41P Pressure gauge: G41D-8-P10 Model R8000 A A6 R4000 L R3000 6 R1000 R1000 Regulator I Internal structure and parts list • R1000 Refrigerating type dryer • R3000 / R4000 Desiccant type dryer 9 1 6 9 8 1 Air filter 7 IN High polymer membrane dryer 6 OUT IN OUT 7 2 F.R.L (Module) 2 3 4 Automatic drain other F.R.L (Separate) 3 Small F.R. 4 Precise R. Electro pneumatic R. 5 5 Auxiliary Flow control valve • R8000 Silencer Check valve / others 9 1 Joint / tube 6 8 Vacuum F. 7 2 Vacuum R. 3 Vacuum generator Vacuum auxiliary / pad 4 Mechanical pressure SW Electronic pressure SW Electronic dif. pres. SW Seating / close contact conf. SW 5 Material No. Part name 1 Plate cover 2 Body 3 Diaphragm assembly 4 Cover 5 Knob Polyacetal resin 6 Valve assembly Brass and nitrile rubber 7 Pressure gauge assembly PBT resin, nitrile rubber, polyacetal resin, polycarbonate resin, brass and steel 9 Blanking plug assembly Note 1 Bottom plug R3000 R4000 R8000 Flow sensor for air ABS resin Polyamide resin and steel Polyacetal resin Nitrile rubber Aluminum ally die casting Zinc alloy die-casting and nitrile rubber PBT resin Polyamide resin — Pressure SW for coolant Total air system Aluminum ally die casting Water cooling refrigerator Flow sensor for water Polyamide resin, nitrile rubber and steel PBT resin Nitrile rubber and copper — Polyacetal resin Aluminum ally die casting Note 1: A blanking plug is attached to R1000 standard type. If a gauge plug assembly attached type is required instead of a blanking plug, indicate R1000-*-T1-*. F.R.L. unit Regulator 8 Gauge plug assembly R1000 Regulator Series Dimensions (File name: Page 364 or Ending 16) Attachment (Piping adapter set) X 51 36 40 2 a. di 26 .5 24.5 OUT Tube center 68.5 29 IN Panel cut dimension 35 43.5 Y 83 40 Port size Rc1/8(6) Rc1/4(8) Attachment (Pressure gauge) 45 53.5 • R1000 Panel plate thickness: Max. 6mm 2 2.5 Option with PPD Attachment (C type bracket) Attachment (L type bracket) Tube center 45 10 10 6.5 35 Pressure gauge attached option dimensions table Attached pressure gauge 43.5 6.5 68 44 Tube center G49P 44 68 X Y (73) 43.5 dia. G59P (78) 52 dia. G40P (74.5) 42.5 dia. G50P (75.5) 52.5 dia. G41P (74) 42 dia. (File name: Page 364 or Ending 16) Attachment (Piping adapter set) X 47 32 2.3 Panel cut dimension Attachment (Pressure gauge) Port size Rc1/4(8) Rc3/8(10) Option with PPD di a. 40 2.3 2-4.5 dia. (Note 1) 52 45 31.5 3 58 66.5 104 40 Y 32.5 OUT IN 45 2.5 103 63 45 53.5 • R3000 40 53.5 Dimensions when operating knobs 26.5 Panel plate thickness: Max. 7mm Dimensions when operating knobs Attachment (C type bracket) Attachment (L type bracket) Tube center 67 58 45 53.5 7 7 16.5 66.5 34.5 Tube center IN OUT Pressure gauge attached option dimensions table Attached pressure gauge 16.5 34.5 67 Note 1: Non-rotating fixing can be done by M4 screw. Screw length is to be plate thickness + 8mm or less, and can be screwed in without female thread machining. G49P X Y (69) 43.5 dia. G59P (74) 52 dia. G40P (70.5) 42.5 dia. G50P (71.5) 52.5 dia. G41P (70) 42 dia. Regulator D Dimensions Refrigerating type dryer (File name: Page 364 or Ending 16) Attachment (Piping adapter set) X 52 40 120 Rc3/4: 130 High polymer membrane dryer 55 Automatic drain other di a. 45 53.5 40 Y 110 F.R.L (Module) 45 35 OUT IN Air filter Panel cut dimension 2.3 2.5 80 Desiccant type dryer Attachment (Pressure gauge) Port size Rc1/4(8) Rc3/8(10) Rc1/2(15) Option with PPD 2-4.5 dia. (Note 1) 63 2.3 Panel plate thickness: Max. 7mm Small F.R. Precise R. Electro pneumatic R. 55 39.5 3 F.R.L (Separate) 58 65.6 • R4000 Dimensions when operating knobs Auxiliary Attachment (C type bracket) Flow control valve Attachment (L type bracket) Silencer Pressure gauge attached option dimensions table Attached pressure gauge 45 53.5 7 7 58 14 65.6 Tube center 84 55 14 OUT Tube center IN 55 84 Note 1: Non-rotating fixing can be done by M4 screw. Screw length is to be plate thickness + 8mm or less, and can be screwed in without female thread machining. X Y G49P (74) 43.5 dia. G59P (79) 52 dia. G40P (75.5) 42.5 dia. G50P (76.5) 52.5 dia. G41P (75) 42 dia. Check valve / others Joint / tube Vacuum F. Vacuum R. Vacuum generator Vacuum auxiliary / pad • R8000 Mechanical pressure SW (File name: Page 364 or Ending 16) X 62 50 170 Rc1 1/4 : 176 40 IN Y OUT Electronic dif. pres. SW Seating / close contact conf. SW 2.3 50 61 100 Electronic pressure SW 65 Pressure SW for coolant Flow sensor for air 159 Attachment (Piping adapter set) Total air system Port size Rc3/4(20) Rc1(25) Attachment (Pressure gauge) Dimensions when operating knobs 4 With PPD (Option) Water cooling refrigerator Flow sensor for water 50 F.R.L. unit Regulator Attachment (C type bracket) 104 68 16 Tube center 61 50 9 Pressure gauge attached option dimensions table Attached pressure gauge G49P X Y (85) 43.5 dia. G59P (90) 52 dia. G40P (86.5) 42.5 dia. G50P (87.5) 52.5 dia. G41P (86) 42 dia. Reverse regulator R1100/R3100/R4100/R8100 Series Reverse flow function integrated. Secondary pressure to primary side Port size: Rc1/8 to Rc1 JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R1100 R3100 R4100 R8100 Appearance Working fluid Compressed air Max. working pressure MPa Withstanding pressure MPa Working temperature 1.0 1.5 °C 5 to 60 Set pressure range (Note 2) MPa 0.05 to 0.85 Relief With relief mechanism Port size Rc 1/8 and 1/4 (use an adaptor for 3/8.) 1/4 and 3/8 (use an adaptor for 1/2.) 1/4, 3/8 and 1/2 (use an adaptor for 3/4.) 3/4 and 1 (use an adaptor for 11/4.) Product mass kg 0.16 Standard accessories 0.45 0.7 1.6 Pressure gauge, nut for panel mount Pressure gauge Note 1: The primary pressure is to be 0.05MPa higher than the secondary pressure. Note 2: Always review the set pressure for back pressure on Page 333 when selecting a model. Pressure characteristics • R3100 Secondary pressure (MPa) Secondary pressure (MPa) • R1100 0.24 0.22 0.2 Set pressure 0.18 0.16 0.2 0.4 0.6 0.22 0.21 0.2 Set pressure 0.19 0.18 0 0.8 0.4 0.8 0.6 • R8100 Secondary pressure (MPa) Secondary pressure (MPa) • R4100 0.21 0.2 Set pressure 0.19 0.18 0.17 0 0.2 Primary pressure (MPa) Primary pressure (MPa) 0.2 0.4 0.6 0.8 Primary pressure (MPa) 1 0.21 0.2 Set pressure 0.19 0.18 0.17 0.2 0.4 0.6 0.8 Primary pressure (MPa) Regulator Series Flow characteristics / pressure characteristics Flow characteristics • R1100-6 • R1100-8 Refrigerating type dryer • R3100-8 Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 0 1.0 0.5 1.5 Primary pressure 0.7MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 3.0 2.0 1.0 Secondary pressure (MPa) 0.6 Secondary pressure (MPa) Secondary pressure (MPa) Desiccant type dryer 0.6 0.5 0.4 Air filter 0.3 Automatic drain other 0.2 0.1 F.R.L (Module) 0 0.5 Air flow rate (m3/min (ANR) ) Air flow rate (m3/min (ANR) ) High polymer membrane dryer Primary pressure 0.7MPa 1.0 2.0 1.5 2.5 F.R.L (Separate) Air flow rate (m3/min (ANR) ) Small F.R. 0.6 Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 0 1.0 2.0 3.0 4.0 5.0 • R4100-10 Primary pressure 0.7MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 0.5 Air flow rate (m3/min (ANR) ) 1.0 1.5 2.0 2.5 Secondary pressure (MPa) • R4100-8 Secondary pressure (MPa) Secondary pressure (MPa) • R3100-10 Precise R. Electro pneumatic R. Primary pressure 0.7MPa 0.6 0.5 Auxiliary 0.4 Flow control valve 0.3 0.2 Silencer 0.1 0 1.0 2.0 3.0 4.0 5.0 Air flow rate (m3/min (ANR) ) Air flow rate (m3/min (ANR) ) Check valve / others Joint / tube 0.6 Primary pressure 0.7MPa 0.5 0.4 0.3 0.2 0.1 0 1.0 Air flow rate 2.0 3.0 (m3/min 4.0 5.0 Primary pressure 0.7MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 2 Vacuum F. • R8100-25 4 6 8 10 12 14 Air flow rate (m3/min (ANR) ) Secondary pressure (MPa) • R8100-20 Secondary pressure (MPa) Secondary pressure (MPa) • R4100-15 Vacuum R. Primary pressure 0.7MPa 0.6 0.5 0.3 Mechanical pressure SW 0.2 0.1 0 2 4 Air flow rate (ANR) ) • Set pressure range for back pressure Note: This product can not be used in the upper area Vacuum generator Vacuum auxiliary / pad 0.4 6 8 (m3/min 10 (ANR) ) 12 14 Electronic pressure SW Electronic dif. pres. SW Seating / close contact conf. SW Secondary pressure (MPa) of graph, while can be used in the lower area. E.g: For model R4100, if the set pressure is 1 R3100 R4100 R1100 0.8 0.2MPa, and secondary side back pressure is Not available 0.6MPa and over, the secondary pressure 0.6 Available never achieves to the primary side. 0.4 Pressure SW for coolant Flow sensor for air Total air system 0.2 0 0.1 0.2 0.3 Set pressure (MPa) 0.4 0.5 Water cooling refrigerator Flow sensor for water F.R.L. unit Reverse regulator 333 Regulator Series How to order Model Symbol B B C C Option Note 1 Note 2 Note 3 Note 4 Note 5 * Refer to Page 267 for explanation on options. 6 Rc1/8 8 Rc1/4 10 Rc3/8 15 Rc1/2 20 Rc3/4 25 Rc1 Option Pressure Blank range L Blank Relief N Blank Pressure gauge T Attachment Note 6 Note 7 Note on model No. selection 334 With relief mechanism Non-relief type With standard pressure gauge (G401) Without pressure gauge (gauge port is sealed) R1 Pressure switch with display PPD assembly IN / OUT reverse flow (right→left) Ozone proof specifications (custom order) Attachment A6 Rc1/8 piping adapter set A8 Rc1/4 piping adapter set A10 Rc3/8 piping adapter set A15 Rc1/2 piping adapter set A20 Rc3/4 piping adapter set A25 Rc1 piping adapter set A32 Note 1: When selecting multiple options, write them from the top. Note 2: If "L" is selected for pressure range, a low pressure gauge (0-0.4MPa) is provided. Note 3: Positions of a check valve and a pressure gauge can not be changed. If the reverse direction of IN and OUT is required, indicate "X1" in the end of optional sections. Note 4: For "T", a gauge plug is assembled instead of a pressure gauge. Note 5: Refer to Page 259 for "R1" for details. Working temperature range is 5 to 50 °C. Note 6: A piping adaptor set A*00-** (refer to page 586) is attached. Note 7: Refer to " auxiliary components " (Page 557 to) for attachments. Also, a piping adapter set and a C type bracket can not be used together. 0.05 to 0.35MPa Round shaped pressure gauge attached (pressure gauge port is not sealed.) P11 D 0.05 to 0.85MPa T8 X1 D Descriptions Port size Port size Rc1 1/4 piping adapter set B C type bracket B3 L type bracket G49P Pressure gauge: G49D-8-P10 G59P Pressure gauge: G59D-8-P10 G40P Pressure gauge: G40D-8-P10 G50P Pressure gauge: G50D-8-P10 G41P Pressure gauge: G41D-8-P10 Model R8100 A A6 R4100 L R3100 A 6 R1100 R1100 Regulator I Internal structure and parts list Functional explanation • R1100 If the primary pressure is applied from IN side, since the check valve closes due to the primary pressure and spring load, this regulator functions as a normal regulator. However, if the primary pressure is exhausted by a switching valve such as shut-off valve, etc., the check valve is opened immediately due to the secondary pressure, then the pressure drops by exhausting the pressure in the diaphragm room. The diagram is lowered by the adjusting spring, and the main valve will open to exhaust the air to OUT side. 9 8 1 7 6 IN OUT 3 2 4 5 Desiccant type dryer High polymer membrane dryer Air filter Automatic drain other F.R.L (Module) F.R.L (Separate) Small F.R. • Circuit diagram When head side and rod side pressure of a cylinder differ. • R3100 / R4100 Refrigerating type dryer Precise R. Electro pneumatic R. A 1 Auxiliary 9 8 6 Flow control valve 7 IN OUT Silencer Check valve / others 2 Joint Note: If the primary pressure is released, the back pres- / tube sure for the set pressure of regulator is not to be Vacuum grater than Graph A; "set pressure range for back F. pressure". 4 3 Vacuum R. 5 Vacuum generator • R8100 Vacuum auxiliary / pad 1 9 Mechanical pressure SW 8 Electronic pressure SW 6 IN OUT 7 Electronic dif. pres. SW Seating / close contact conf. SW 3 2 4 Pressure SW for coolant Flow sensor for air 5 Total air system No. Part name Material R1100 Plate cover 2 Body PA resin and steel 3 Diaphragm assembly Polyacetal resin Nitrile rubber 4 Cover Polyamide resin 5 Knob R3100 R4100 R8100 ABS resin Aluminum ally die casting Zinc alloy die-casting and nitrile rubber PBT resin Aluminum ally die Polyacetal resin Brass and nitrile rubber 6 Valve assembly 7 Pressure gauge assembly PBT resin, nitrile rubber, polyacetal resin, polycarbonate resin, brass and copper 8 Check valve total assembly 9 Bottom plug PBT resin, nitrile rubber, stainless steel wire and steel Note 1: Refer to Page 338 for repair kits. Polyacetal resin Aluminum ally die Water cooling refrigerator Flow sensor for water F.R.L. unit Reverse regulator 1 Regulator Series Dimensions (File name: Page 364 or Ending 16) Attachment (Piping adapter set) X 51 36 2 68.5 di a. .5 Tube center 26 OUT Panel cut dimension 35 43.5 24.5 IN 40 Y 83 40 29 45 53.5 • R1100 Port size Rc1/8(6) Rc1/4(8) Attachment (Pressure gauge) Panel plate thickness: Max. 6mm 2 Attachment (C type bracket) 68 44 40 Attachment (L type bracket) Tube center Tube center 53.5 Attached pressure gauge 44 68 G49P X Y (73) 43.5 dia. G59P (78) 52 dia. G40P (74.5) 42.5 dia. G50P (75.5) 52.5 dia. G41P (74) 42 dia. (File name: Page 364 or Ending 16) 104 Port size Rc1/4(8) Rc3/8(10) Option with PPD 2.3 Attachment (C type bracket) 52 45 31.5 3 Dimensions when Attachment operating knobs (Piping adapter set) Panel cut dimension 45 53.5 2.5 32.5 OUT IN 2.3 a. 45 Y 103 63 di X 47 32 40 Attachment (Pressure gauge) 40 58 66.5 • R3100 Pressure gauge attached option dimensions table 10 6.5 35 45 10 43.5 6.5 35.5 Option with PPD 2.5 Dimensions when operating knobs 2-4.5 dia. (Note 1) Panel plate thickness: Max. 7mm Attachment (L type bracket) 67 Tube center Tube center 7 45 53.5 7 58 16.5 16.5 34.5 67 Note 1. Non-rotating fixing can be done by M4 screw. Screw length is to be plate thickness +8mm or less, and a set screw can be screwed into without female thread machining. 66.5 34.5 Pressure gauge attached option dimensions table Attached pressure gauge G49P X Y (69) 43.5 dia. G59P (74) 52 dia. G40P (70.5) 42.5 dia. G50P (71.5) 52.5 dia. G41P (70) 42 dia. Regulator Series Dimensions Dimensions Refrigerating type dryer (File name: Page 364 or Ending 16) Attachment (Pressure gauge) X 52 40 High polymer membrane dryer 55 2.3 Automatic drain other F.R.L (Module) 40 58 65.6 2.5 63 35 OUT IN Air filter Panel cut dimension 45 53.5 Y 120 Rc3/4: 130 80 Desiccant type dryer di a. • R4100 110 Port size Rc1/4(8) Rc3/8(10) Rc1/2(15) Option with PPD F.R.L (Separate) 2.3 2-4.5 dia. (Note 1) 63 Panel plate thickness: Max. 7mm Precise R. 55 39.5 3 Dimensions when operating knobs Attachment (Piping adapter set) Small F.R. Electro pneumatic R. Auxiliary Attachment (C type bracket) Attachment (L type bracket) Flow control valve 84 55 Tube center 58 45 53.5 7 7 14 55 84 Tube center Note 1.Non-rotating fixing can be done by M4 screw. Screw length is to be plate thickness +8mm or less, a set screw can be screwed into without female machining. 65.6 Silencer 14 Pressure gauge attached option dimensions table Attached pressure gauge X Y G49P (74) 43.5 dia. G59P (79) 52 dia. G40P (75.5) 42.5 dia. G50P (76.5) 52.5 dia. G41P (75) 42 dia. Check valve / others Joint / tube Vacuum F. Vacuum R. Vacuum generator Vacuum auxiliary / pad • R8100 Mechanical pressure SW (File name: Page 364 or Ending 16) Attachment (Piping adapter set) X 62 50 170 Rc1 1/4 : 176 100 Electronic dif. pres. SW Seating / close contact conf. SW 65 40 61 2.3 Pressure SW for coolant Y OUT IN Electronic pressure SW Flow sensor for air 159 Attachment (Pressure gauge) Total air system Rc3/4(20) Rc1(25) Option with PPD Water cooling refrigerator 50 4 Dimensions when operating knobs Port size Flow sensor for water 104 68 16 Tube center 61 50 9 Pressure gauge attached option dimensions table Attached pressure gauge G49P X Y (85) 43.5 dia. G59P (90) 52 dia. G40P (86.5) 42.5 dia. G50P (87.5) 52.5 dia. G41P (86) 42 dia. F.R.L. unit Reverse regulator Attachment (C type bracket) 337 Regulator Series Optional parts drawing Repair kits (set of diaphragm assembly, valve assembly, bottom spring and bottom O ring) Repair kits model no. Relief type diaphragm Non-relief type diaphragm R1000, R1100 R1000-KIT R1000-KIT-N R3000, R3100 R3000-KIT R3000-KIT-N R4000, R4100 R4000-KIT R4000-KIT-N R8000, R8100 R8000-KIT R8000-KIT-N Model Valve assembly (set of valve assembly, bottom spring and bottom O ring) Model Valve assembly model no. R1000, R1100 R1000-VALVE-ASSY R3000, R3100 R3000-VALVE-ASSY R4000, R4100 R4000-VALVE-ASSY R8000, R8100 R8000-VALVE-ASSY *Refer to Page 113 for gauge plug assembly. Check valve assembly for reverse regulator Model Check valve assembly model no. R1100, W1100 R3100, W3100 R4100, W4100 R8100, W8100 R1100-CHECK-VALVE-ASSY R3100-CHECK-VALVE-ASSY Adjusting spring L Adjusting spring for low pressure Adjusting spring Standard spring Spring for low pressure (0.05 to 0.85MPa) (0.05 to 0.35MPa) R1100 W1100 R3100 W3100 R4100 W4100 R1000-SPRING R1000-SPRING-L R3000-SPRING R3000-SPRING-L R4000-SPRING R4000-SPRING-L R8000, R8100 R8000-SPRING R8000-SPRING-L W8000, W8100 W8000-SPRING W8000-SPRING-L Adjusting spring model no. Model R1000, W1000, R3000, W3000, R4000, W4000, Diaphragm assembly (diaphragm assembly only) Diaphragm assembly model no. Relief type diaphragm Non-relief type diaphragm R1100 W1100 R3100 W3100 R4100 W4100 R1000-DIAPHRAGM-ASSY R1000-DIAPHRAGM-ASSY-N R3000-DIAPHRAGM-ASSY R3000-DIAPHRAGM-ASSY-N R4000-DIAPHRAGM-ASSY R4000-DIAPHRAGM-ASSY-N R8000, R8100 R8000-DIAPHRAGM-ASSY R8000-DIAPHRAGM-ASSY-N W8000, W8100 W8000-DIAPHRAGM-ASSY W8000-DIAPHRAGM-ASSY-N Diaphragm assembly Machine screw N Non-relief diaphragm assembly Check valve assembly Gasket Model R1000, W1000, R3000, W3000, R4000, W4000, Valve assembly Bottom spring Bottom O ring