20 05 Contactors - new line • mini-contactors • contactors up to 100 A • contactors over 100 A • thermal overload relays • auxiliary contacts and accessories www.relpol.com.pl Contents 4 Contactors Mini-contactors, Mini-contactors, AC operation DC operation CRMI05 ................................ 6 CRMI09 ................................ 6 11 CRMI09 ............................. 11 Contactors up to 100 A, Contactors up to 100 A, AC operation DC operation CRNI09 ................................. 6 CRNI12 ................................. 6 CRNI16 ................................. 7 CRNI22 ................................. 7 CRNI32 ................................. 7 CRNI38 ................................. 7 CRNI45 ................................. 8 CRNI63 ................................. 8 CRNI75 ................................. 8 CRNI85 ................................. 8 Contactors over 100 A, AC operation CRLI110 ............................... 9 CRLI140 ............................... 9 CRLI170 ............................... 9 CRMI05 ............................. 11 CRNI12 .............................. 11 CRNI16 .............................. 12 CRNI22 .............................. 12 CRNI32 .............................. 12 CRNI38 .............................. 12 CRNI45 .............................. 13 CRNI63 .............................. 13 CRNI75 .............................. 13 CRNI85 .............................. 13 Coding system ..................... 14 Add-on blocks ...................... 15 Technical data ...................... 16 Dimensions ......................... 18 Permissible mounting positions 19 CRNI09 .............................. CRLI205 ............................... 9 10 CRLI300 ............................ 10 CRLI400 ............................ 10 CRLI250 ............................ Thermal overload relays 20 RSTN1 ............................... 20 RSTN2 ............................... 20 RSTN3 ............................... 21 RSTN4 ............................... 21 RSTL1 ................................ 21 RSTL2 ................................ 21 RSTM ................................. www.relpol.com.pl 22 RSTL4 ................................ 22 RSTL3 ................................ Add-on blocks for independent 22 Technical data ...................... 23 Dimensions ......................... 28 mounting ............................. Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 5 The new line of contactors of Relpol S.A. includes three groups divided due to the current switching capacity and sizes related hereto, i.e. mini-contactors CRMI up to 9 A, contactors of type CRNI up to 100 A and contactors of CRLI type over 100 A. The contactors may operate at the frequency of 50/60 Hz. Rated voltages of the contactors are from 690 V to 1000 V at rated switching current from 5 A to 400 A, for AC3 Class. The contactors provide controlling the operation of long electrical circuits, switching on and off electrical AC motors The contactors are compliant with the following standards: IEC/EN 60947 and VDE 0660. Operating conditions: - the altitude of the installation site shall not exceed 2000 meters over sea level, - ambient temperature: from -25 oC to +55 oC, - atmospheric conditions: air shall not contain explosive gases, media, caustic gases or conductive dust, - shock and vibrations shall not exceed the values specified by the manufacturer, - the contactors shall not be used in the rain or snow. Characteristics: - the conductive parts are covered for better safety, - the design of the main contact set is unique , which results in extended electrical life, - the special design of the supply system provides low noise level, high reliability and significant strength, - the contactors co-operate with auxiliary contact blocks, - the terminals provide easy and reliable connection, and high resistance to shock. •••••••••••••••••••••••• Thermal overload relays of RSTM, RSTN and RSTL types are used for protection of AC motors of 50/60 Hz frequency against overload and phase error. Rated voltages of the relays are from 690 V to 1000 V, at rated switching current from 0,1A to 400 A. The relays may also be used for protection of DC electromagnets and DC motors against overload. Individual functions provide protection against phase errors, compensation of temperature impact, indication of ON/OFF status, manual or automatic reset, etc. The relays may be mounted on contactors or as separate devices. Operating conditions: - the altitude of the installation site shall not exceed 2000 meters over sea level, - ambient temperature: from -25 oC to +55 oC, - relative humidity shall not exceed 90% at 25 oC. Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl CRMI, CRNI Mini-contactors and contactors up to 100 A, AC operation 6 Type of contactor CRMI05 CRMI09 CRNI09 CRNI12 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ – CRNI12-30-10-... 1 CRMI05-30-10-... 1 – CRMI09-30-10-... 1 – CRNI09-30-10-... 1 – Ordering codes ❶ CRMI05-30-01-... – ❶ CRMI05-40-00-... – Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V AC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [VA] Power cosφ at closing consumption of AC coil (50 Hz) closed [VA] cosφ at closed Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] Rated operating current AC15 of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] three-pole four-pole 1 – ❶ CRMI09-30-01-... – ❶ CRMI09-40-00-... – 1 – ❶ 1 CRNI12-30-01-... – ❷ – CRNI12-40-00-... – CRNI09-30-01-... – CRNI09-40-00-... – ❶ 1 ❷ – 690 5 1,9 1,3 2,2 2,9 3,8 – 0,81 0,86 10 0,8 0,2 1000 – (0,8 - 1,1) Us 15 0,41 6,8 0,42 16 10 690 9 2,6 2,4 4 4 4 – 1,10 1,10 10 0,4 0,2 1000 – (0,8 - 1,1) Us 15 0,41 6,8 0,42 16 10 690 9 3,3 2,4 4 5,5 5,5 – 1,48/1,4 2,54/2,4 15 1,2 0,2 1000 250 (0,8 - 1,1) Us 68 0,82 10 0,29 20 10 690 12 4,3 3,3 5,5 7,5 7,5 – 2/1,9 3,45/3,3 15 1,2 0,2 1000 250 (0,8 - 1,1) Us 68 0,82 10 0,29 20 10 690 690 690 690 –/4 –/4 6/10 6/10 0,5/0,3 0,5/0,3 0,9/0,45 0,9/0,45 0,18 0,19 0,18 0,19 0,37 0,37 0,37 0,37 Ordering coil codes ❶ A024 - 24 V AC 50 Hz A230 - 230 V AC 50 Hz ❷ A230 - 230 V AC 50 Hz For other voltages, contact Relpol S.A. Coil of contactor 50 Hz Operating at 50 Hz 24 V 230 V 60 Hz 29 V 277 V Thermal overload relays Type of thermal overload relay Module for installing as a single unit Relay base for installing as a single unit www.relpol.com.pl RSTM CRI-310 – RSTM CRI-310 – RSTN1 – CRI-320 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 RSTN1 – CRI-320 CRNI Contactors up to 100 A, AC operation Type of contactor CRNI16 CRNI22 7 CRNI32 CRNI38 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRNI16-30-00-... – – CRNI22-30-00-... – – CRNI32-30-00-... – – CRNI38-30-00-... – – Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V AC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [VA] Power cosφ at closing consumption of AC coil (50 Hz) closed [VA] cosφ at closed Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] Rated operating current AC15 of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 690 16 7,7 4 7,5 9 11 – 3,5 6 15 1,2 0,2 750 250 (0,8 - 1,1) Us 68 0,82 10 0,29 30 10 690 22 8,5 5,5 11 11 11 – 4 6,6 15 1,2 0,2 750 250 (0,8 - 1,1) Us 68 0,82 10 0,29 30 10 690 32 15,6 8,5 15 21 23 – 7,5 13 10 1,2 0,2 750 250 (0,8 - 1,1) Us 101 0,83 12,1 0,28 55 10 690 38 18,5 11 18,5 25 23 – 9 15,5 10 1,2 0,2 600 200 (0,8 - 1,1) Us 101 0,83 12,1 0,28 55 10 690 690 690 690 4/6 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 1,14/0,48 0,45 0,45 0,68 0,68 Ordering coil codes ❶ A024 - 24 V AC 50 Hz A230 - 230 V AC 50 Hz For other voltages, contact Relpol S.A. Coil of contactor 50 Hz Operating at 50 Hz 24 V 230 V Thermal overload relays Type of thermal overload relay Relay base for installing as a single unit RSTN2 CRI-330 RSTN2 CRI-330 RSTN3 CRI-340 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 60 Hz 29 V 277 V RSTN3 CRI-340 www.relpol.com.pl CRNI Contactors up to 100 A, AC operation 8 Type of contactor CRNI45 CRNI63 CRNI75 CRNI85 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRNI45-30-22-... 2 2 CRNI63-30-22-... 2 2 CRNI75-30-22-... 2 2 CRNI85-30-22-... 2 2 Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V AC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [VA] Power cosφ at closing consumption of AC coil (50 Hz) closed [VA] cosφ at closed Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] Rated operating current AC15 of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 1000 45 24 15 22 30 39 7-5 12,6/12 21,8/20,8 10 1,2 0,2 1200 400 (0,8 - 1,1) Us 183 0,6 17 0,29 80 10 1000 63 28 18,5 30 41 55 7-5 14,7/14 25,4/24,3 10 1,2 0,2 1000 300 (0,8 - 1,1) Us 183 0,6 17 0,29 90 10 1000 75 34 22 37 50 67 39 17,9/17 30,9/29,5 10 1,2 0,2 1000 300 (0,8 - 1,1) Us 330 0,5 32 0,23 100 10 1000 85 42 26 45 59 67 39 22/21 38/36 10 1,2 0,2 850 250 (0,8 - 1,1) Us 330 0,5 32 0,23 100 10 690 690 690 690 4/6 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 1,14/0,48 1,4 1,4 2,3 2,3 Ordering coil codes ❶ A024 - 24 V AC 50 Hz A230 - 230 V AC 50 Hz For other voltages, contact Relpol S.A. Coil of contactor 50 Hz Operating at 50 Hz 24 V 230 V Thermal overload relays Type of thermal overload relay Relay base for installing as a single unit www.relpol.com.pl RSTN4 CRI-350 RSTN4 CRI-350 RSTN4 CRI-350 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 60 Hz 29 V 277 V RSTN4 CRI-350 CRLI Contactors over 100 A, AC operation Type of contactor CRLI110 CRLI140 9 CRLI170 CRLI205 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRLI110-30-22-... 2 2 CRLI140-30-22-... 2 2 CRLI170-30-22-... 2 2 CRLI205-30-22-... 2 2 Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V AC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [VA] Power cosφ at closing consumption of AC coil (50 Hz) closed [VA] cosφ at closed Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] Rated operating current AC15 of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 1000 110 54 37 55 76 100 65 28,4/27 49/46,9 10 1,2 0,2 1000 300 (0,8 - 1,1) Us 550 0,45 39 0,24 160 10 1000 140 68 43 75 98 100 65 36/35 63/60 10 1,2 0,2 750 200 (0,8 - 1,1) Us 550 0,45 39 0,24 160 10 1000 170 75 55 90 118 156 90 40/38 69/66 10 1,2 0,2 700 200 (0,8 - 1,1) Us 910 0,38 58 0,26 210 10 1000 205 96 64 110 145 156 90 52/50 90/86 10 1,2 0,2 500 130 (0,8 - 1,1) Us 910 0,38 58 0,26 220 10 690 690 690 690 4/6 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 1,14/0,48 3,3 3,3 4,8 4,8 Ordering coil codes ❶ A230 - 230 V AC 50 Hz For other voltages, contact Relpol S.A. Coil of contactor 50 Hz Operating at 50 Hz 24 V 230 V Thermal overload relays Type of thermal overload relay Box terminal block for installing as a single unit Links (set - 3 pices) for connections to contactors 60 Hz 29 V 277 V RSTL1 CRI-360 RSTL2 – RSTL3 – RSTL3 – – CRI-370 CRI-382 CRI-382 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl CRLI Contactors over 100 A, AC operation 10 Type of contactor CRLI250 CRLI300 CRLI400 Auxiliary contacts NO NC NO NC NO NC NO NC ❶ ❶ ❶ CRLI250-30-22-... 2 2 CRLI300-30-22-... 2 2 CRLI400-30-22-... 2 2 Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V AC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [VA] Power cosφ at closing consumption of AC coil (50 Hz) closed [VA] cosφ at closed Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] Rated operating current AC15 of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 1000 250 110 78 132 178 235 132 61/58 105/100 10 1,2 0,2 700 200 (0,8 - 1,1) Us 1430 0,34 84 0,24 300 10 1000 300 125 93 160 210 235 132 69/66 119/114 10 1,2 0,2 500 130 (0,8 - 1,1) Us 1430 0,34 84 0,24 300 10 1000 400 150 125 200 284 375 250 85/81 147/140 10 1,2 0,2 500 150 (0,8 - 1,1) Us 2450 0,21 115 0,33 400 10 690 690 690 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 6,2 6,2 8,5 Ordering coil codes ❶ A230 - 230 V AC 50 Hz For other voltages, contact Relpol S.A. Coil of contactor 50 Hz Operating at 50 Hz 24 V 230 V Thermal overload relays Type of thermal overload relay Links (set - 3 pices) for connections to contactors www.relpol.com.pl RSTL4 CRI-390 RSTL4 CRI-390 60 Hz 29 V 277 V RSTL4 CRI-390 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 CRMI, CRNI Mini-contactors and contactors up to 100 A, DC operation 11 Type of contactor CRMI05 CRMI09 CRNI09 CRNI12 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRMI05-30-10-... 1 – CRMI09-30-10-... 1 – CRNI09-30-00-... – – CRNI12-30-00-... – – Ordering codes ❶ CRMI05-40-00-... – Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V DC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [W] Power consumption closed [W] of DC coil Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] AC15 Rated operating current of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] three-pole four-pole – ❶ CRMI09-40-00-... – – ❶ CRNI09-40-00-... – – ❶ CRNI12-40-00-... – 690 5 1,9 1,3 2,2 2,9 3,8 – 0,81 0,86 20 0,8 0,2 1000 250 (0,8 - 1,1) Us 3 3 16 10 690 9 2,6 2,4 4 4 4 – 1,10 1,10 20 0,4 0,2 1000 250 (0,8 - 1,1) Us 3 3 16 10 690 9 3,3 2,4 4 5,5 5,5 – 1,48/1,4 2,54/2,4 15 1,2 0,2 1000 250 (0,8 - 1,1) Us 6,2 6,2 20 10 690 12 4,3 3,3 5,5 7,5 7,5 – 2/1,9 3,45/3,3 15 1,2 0,2 1000 250 (0,8 - 1,1) Us 6,2 6,2 20 10 690 690 690 690 –/4 –/4 6/10 6/10 0,5/0,3 0,5/0,3 0,9/0,45 0,9/0,45 0,22 0,22 0,22 0,22 0,58 0,58 0,58 0,58 RSTM CRI-310 – RSTM CRI-310 – RSTN1 – CRI-320 RSTN1 – CRI-320 – Ordering coil codes ❶ D024 - 24 V DC For other voltages, contact Relpol S.A. Thermal overload relays Type of thermal overload relay Module for installing as a single unit Relay base for installing as a single unit Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl CRNI Contactors up to 100 A, DC operation 12 Type of contactor CRNI16 CRNI22 CRNI32 CRNI38 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRNI16-30-00-... – – CRNI22-30-00-... – – CRNI32-30-00-... – – CRNI38-30-00-... – – Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V DC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [W] Power consumption closed [W] of DC coil Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] AC15 Rated operating current of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 690 16 7,7 4 7,5 9 11 – 3,5 6 15 1,2 0,2 750 250 (0,8 - 1,1) Us 6,2 6,2 30 10 690 22 8,5 5,5 11 11 11 – 4 6,6 15 1,2 0,2 750 250 (0,8 - 1,1) Us 6,2 6,2 30 10 690 32 15,6 8,5 15 21 23 – 7,5 13 10 1,2 0,2 750 250 (0,8 - 1,1) Us 11,7 11,7 55 10 690 38 18,5 11 18,5 25 23 – 9 15,5 10 1,2 0,2 600 200 (0,8 - 1,1) Us 11,7 11,7 55 10 690 690 690 690 4/6 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 1,14/0,48 0,70 0,70 1,25 1,25 RSTN2 CRI-330 RSTN2 CRI-330 RSTN3 CRI-340 RSTN3 CRI-340 Ordering coil codes ❶ D024 - 24 V DC For other voltages, contact Relpol S.A. Thermal overload relays Type of thermal overload relay Relay base for installing as a single unit www.relpol.com.pl Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 CRNI Contactors up to 100 A, DC operation Type of contactor CRNI45 CRNI63 13 CRNI75 CRNI85 Auxiliary contacts NO NC NO NC NO NC NO NC NO NC ❶ ❶ ❶ ❶ CRNI45-30-22-... 2 2 CRNI63-30-22-... 2 2 CRNI75-30-22-... 2 2 CRNI85-30-22-... 2 2 Ordering codes Rated insulation voltage [V] Rated operating current (380 V) Rated outputs of three phase AC3 motors at 50 Hz [kW] AC4 Mechanical life (x 106) Electrical life (x 106) AC3 AC4 230/220 V 400/380 V 500 V 690/660 V 1000 V 400/380 V 690/660 V DC AC3 AC4 AC3 AC4 Maximum switching frequency (1/h) Range of supply coil voltage closing [W] Power consumption closed [W] of DC coil Conventional thermal current Ith [A] Conventional thermal current Ith of auxiliary contacts [A] Rated insulation voltage of auxiliary contacts [V] AC15 Rated operating current of auxiliary contacts [A] 380/220 V DC13 110/220 V Weight [kg] 1000 45 24 15 22 30 39 7–5 12,6/12 21,8/20,8 3 1,2 0,2 1200 400 (0,8 - 1,1) Us 400 2,1 80 10 1000 63 28 18,5 30 41 55 7–5 14,7/14 25,4/24,3 3 1,2 0,2 1000 300 (0,8 - 1,1) Us 400 2,1 90 10 1000 75 34 22 37 50 67 39 17,9/17 30,9/29,5 3 1,2 0,2 1000 300 (0,8 - 1,1) Us 420 2,7 100 10 1000 85 42 26 45 59 67 39 22/21 38/36 3 1,2 0,2 850 250 (0,8 - 1,1) Us 420 2,7 100 10 690 690 690 690 4/6 4/6 4/6 4/6 1,14/0,48 1,14/0,48 1,14/0,48 1,14/0,48 1,4 1,4 2,3 2,3 RSTN4 CRI-350 RSTN4 CRI-350 RSTN4 CRI-350 RSTN4 CRI-350 Ordering coil codes ❶ D024 - 24 V DC For other voltages, contact Relpol S.A. Thermal overload relays Type of thermal overload relay Relay base for installing as a single unit Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Contactors Coding system 14 Contactors coding system Type of contactor Type of contactor Value of current Value of current Configuration of operating contacts Configuration of auxiliary contacts Type and value of coil voltage Configuration of auxiliary contacts ❶ 75 - 75 A Configuration of operating / main contacts 05 - 5 A 85 - 85 A 30 - three-pole 00 - failure D024 - 24 V DC CRNI - contactors up to 100 A 09 - 9 A 110 - 110 A 40 - four-pole 01 - 1 NC A024 - 24 V AC 50 Hz CRLI - contactors over 100 A 12 - 12 A 140 - 140 A 10 - 1 NO A230 - 230 V AC 50 Hz 16 - 16 A 170 - 170 A 22 - 22 A 205 - 205 A 40 - 4 NO 32 - 32 A 250 - 250 A 31 - 3 NO and 1 NC 38 - 38 A 300 - 300 A 22 - 2 NO and 2 NC 45 - 45 A 400 - 400 A CRMI mini-contactors 00 - Contact configuration of contactor relays Type and value of coil voltage 22 - 2 NO + 2 NC 63 - 63 A ❶ See page 15 - Contactor relays CRMI00 Examples of ordering codes: CRMI09-30-10-A230 mini-contactor, rated operating current 9 A AC3, three-pole, 1 auxiliary contact normally open, coil voltage 230 V AC 50 Hz CRNI12-30-10-D024 contactor up to 100 A, rated operating current 12 A AC3, three-pole, 1 auxiliary contact normally open, coil voltage 24 V DC CRNI12-40-00-D024 contactor up to 100 A, rated operating current 12 A AC3, four-pole, failure auxiliary contacts, coil voltage 24 V DC CRLI110-30-22-A230 contactor over 100 A, rated operating current 110 A AC3, three-pole, 2 auxiliary contacts normally open and 2 auxiliary contacts normally closed, coil voltage 230 V AC 50 Hz www.relpol.com.pl Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Contactors Add-on blocks 15 Auxiliary contacts for mini-contactors CRMI Ordering codes Rated operating current Ie (AC-15) AC-14 at voltage: 230 / 400 / 500 V 690 / 220 V 380 V 660 V [A] [A] [A] [A] Contact number Weight [kg] NO NC CRI10-11 4 3 2 – 1 1 0,04 CRI10-20 4 3 2 – 2 – 0,04 CRI10-02 4 3 2 – – 2 0,04 CRI10-40 4 3 2 – 4 – 0,04 CRI10-31 4 3 2 – 3 1 0,04 CRI10-22 4 3 2 – 2 2 0,04 CRI10-13 4 3 2 – 1 3 0,04 CRI10-04 4 3 2 – – 4 0,04 Contactor relays CRMI00 ❶ Ordering codes Rated operating current Ie (AC-15) AC-14 at voltage: 230 / 400 / 500 V 690 / 220 V 380 V 660 V [A] [A] [A] [A] Contact number Weight [kg] NO NC CRMI00-40-00-A230 4 3 2 1 4 – 0,19 CRMI00-31-00-A230 4 3 2 1 3 1 0,19 CRMI00-22-00-A230 4 3 2 1 2 2 0,19 Add-on blocks for contactors CRNI, CRLI Ordering codes Contactor application Weight [kg] – from CRNI09 0,02 1 to CRNI38 0,02 1 from CRNI45 0,042 Contact number Rated operating current Ie (AC-15) AC-14 at voltage: 230 / 400 / 500 V 220 V 380 V [A] [A] [A] 690 / 660 V [A] CRI20-10 5,6/6 3,8/4 2,5 1,8/2 1 CRI20-01 5,6/6 3,8/4 2,5 1,8/2 – CRI20-11 5,6/6 3,6/4 2,5 2,3/5 1 NO NC to CRLI400 Auxiliary contacts CRI-420 from CRNI45 to CRLI300 Mechanical latches CRI-430 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 CRLI400 www.relpol.com.pl Contactors Technical data 16 Strength of main contacts (AC3) Electrical life 400 V Electrical life 690 V Electrical life 500 V Electrical life 230 V Type of contactor Strength of main contacts (AC3) www.relpol.com.pl Electrical life 400 V Electrical life 690 V Electrical life 500 V Electrical life 230 V Type of contactor Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Contactors Technical data 17 Strength of main contacts (AC3) Electrical life 400 V Electrical life 690 V Electrical life 500 V Electrical life 230 V Type of contactor Breaking current Rated operating current Rated output of three-phase motors with squirrel-cage (at 400 V) DC circuit diagrams CRNI45 to CRNI85 (DC economy circuit) Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Contactors Dimensions 18 Dimensions Additional module CRMI05 or CRMI09 to be installed as a single unit CRNI16 or CRNI22 + RSTN2 thermal overload relay CRNI09 or CRNI12 + RSTN1 thermal overload relay Auxiliary contacts block with position indicator Labelling plate CRNI32 or CRNI38 + RSTN3 thermal overload relay Type a1 a2 a3 b1 b2 b3 CRNI45 to CRNI85 + RSTN4 thermal overload relay c1 (c1) 1 d1 d2 d3 e e2 f1 f2 f3 g g1 g2 CRNI45, CRNI63 90 113 70 117 175 100 123 123 8 26,5 25 94 34 80 63 122 28 4,8 6,1 (M6) CRNI75 100 123 80 133 194 110 140 140 8 26,5 25 107 36 89 63 122 39 5,5 6,1 (M6) CRNI85 400 123 80 133 194 110 140 140 10,5 26,5 25 116 31,5 89 63 122 39 5,5 6,1 (M6) ( ) DC operation 1 www.relpol.com.pl *) Minimum clearance from the earthed parts. **) Dimension for the square OFF button (stroke 3 mm). Dimension for the round RESET button (stroke 2,5 mm) less 2,5 mm. Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Contactors Dimensions, permissible mounting positions 19 Dimensions *) Minimum clearance from the earthed parts. **) Dimension for the square OFF button (stroke 3 mm). Dimension for the round RESET button (stroke 2,5 mm) less 2,5 mm. Type h j RSTL1 37 M6 RSTL2 42 M8 CRLI110 with box terminal block CRLI140 without box terminal block CRLI110 + RSTL1 thermal overload relay, CRLI140 + RSTL2 thermal overload relay a1 Type a2 a3 b1 b2 b3 c1 d1 d2 d3 e e1 e2 f1 f2 f3 g g1 g2 CRLI110 120 143 100 150 232 130 150 15 37 37 130 213 40 93 80 146 45 6,3 6,1 (M6) CRLI140 120 143 100 150 232 130 150 20 42 37 139 215,5 40,5 93 80 146 45 6,3 b3 f1 g 9 (M8) CRLI205 to CRLI400 a1 Type CRLI170 + RSTL3 thermal overload relay a2 a3 b1 c1 e1 d1 d2 g1 CRLI205 135 158 110 180 160 185 159 115 48 25 48 7 CRLI250, CRLI300 145 168 120 200 180 198 168 132 58 25 48 9 CRLI400 160 183 130 200 180 222 178 150 65 25 48 9 Permissible mounting positions The contactors are designed for operation on vertical mounting surface. CRNI09 to CRNI22 (AC operation) CRNI32 CRNI45 CRNI09 CRNI45 to to to to CRNI38 CRLI400 CRNI22 CRNI85 (AC operation) (AC operation) (DC operation) (DC economy circuit) CRNI32 to CRNI38 (DC operation) Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Thermal overload relays 20 Ordering codes RSTM RSTM-0V16 RSTM-0V25 RSTM-0V4 RSTM-0V63 RSTM-1 RSTM-1V25 RSTM-1V6 RSTM-2 RSTM-2V5 RSTM-3V2 RSTM-4 RSTM-5 RSTM-6V3 RSTM-8 RSTM-10 RSTM-12 Ordering codes RSTN1 RSTN1-0V6 RSTN1-0V25 RSTN1-0V4 RSTN1-0V63 RSTN1-1 RSTN1-1V25 RSTN1-1V6 RSTN1-2 RSTN1-2V5 RSTN1-3V2 RSTN1-4 RSTN1-5 RSTN1-6V3 RSTN1-8 RSTN1-10 RSTN1-12V5 RSTN1-14V5 Ordering codes RSTN2 RSTN2-6V3 RSTN2-8 RSTN2-10 RSTN2-12V5 RSTN2-16 RSTN2-20 RSTN2-25 www.relpol.com.pl Adjustment rated range [A] 0,1 - 0,16 0,16 - 0,25 0,25 - 0,4 0,4 - 0,63 0,63 - 1 0,8 - 1,25 1 - 1,6 1,25 - 2 1,6 - 2,5 2 - 3,2 2,5 - 4 3,2 - 5 4 - 6,3 5-8 6,3 - 10 8 - 12 Adjustment rated range [A] 0,1 - 0,16 0,16 - 0,25 0,25 - 0,4 0,4 - 0,63 0,63 - 1 0,8 - 1,25 1 - 1,6 1,25 - 2 1,6 - 2,5 2 - 3,2 2,5 - 4 3,2 - 5 4 - 6,3 5-8 6,3 - 10 8 - 12,5 10 - 14,5 Adjustment rated range [A] 4 - 6,3 5-8 6,3 - 10 8 - 12,5 10 - 16 12,5 - 20 16 - 25 Fuse links [A] IEC947 - 4 ”1” ”2” 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 0,5 1 1,6 2 4 4 6 6 6 10 10 10 10 10 10 10 Fuse links [A] IEC947 - 4 ”1” ”2” 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 0,5 1 1,6 2 4 4 6 6 6 10 10 16 16 20 25 25 25 Fuse links [A] IEC947 - 4 ”1” ”2” 63 63 63 63 63 63 63 16 20 25 25 35 35 50 Contactor application Weight [kg] CRMI05 CRMI09 0,14 Contactor application Weight [kg] CRNI09 CRNI12 0,14 Contactor application Weight [kg] CRNI16 CRNI22 0,14 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Thermal overload relays 21 Ordering codes RSTN3 RSTN3-12V5 RSTN3-16 RSTN3-20 RSTN3-25 RSTN3-32 RSTN3-36 RSTN3-40 RSTN3-45 Ordering codes RSTN4 RSTN4-20 RSTN4-25 RSTN4-32 RSTN4-40 RSTN4-50 RSTN4-57 RSTN4-63 RSTN4-70 RSTN4-80 RSTN4-88 Ordering codes RSTL1 RSTL1-80 RSTL1-90 RSTL1-110 RSTL1-120 RSTL1-135 Ordering codes RSTL2 RSTL2-80 RSTL2-90 RSTL2-110 RSTL2-120 RSTL2-135 RSTL2-150 Adjustment rated range [A] 8 - 12,5 10 - 16 12,5 - 20 16 - 25 20 - 32 25 - 36 32 - 40 36 - 45 Adjustment rated range [A] 12,5 - 20 16 - 25 20 32 25 - 40 32 - 50 40 - 57 50 - 63 57 - 70 63 - 80 70 - 88 Adjustment rated range [A] 55-80 63-90 80-110 90-120 110-135 Adjustment rated range [A] 55-80 63-90 80-110 90-120 110-135 120-150 Fuse links [A] IEC947 - 4 ”1” ”2” 100 100 100 100 100 100 100 100 25 35 50 50 80 80 80 80 Fuse links [A] IEC947 - 4 ”1” ”2” 160 160 160 160 160 160 160 160 250 250 50 50 63 80 100 100 100 125 160 160 Fuse links [A] IEC947 - 4 ”1” ”2” 250 250 315 315 315 160 160 200 224 224 Fuse links [A] IEC947 - 4 ”1” ”2” 250 250 315 315 315 315 160 160 200 224 224 224 Contactor application Weight [kg] CRNI32 CRNI38 0,20 Contactor application Masa [kg] CRNI45 CRNI63 CRNI75 CRNI85 0,40 Contactor application Weight [kg] CRLI110 0,70 Contactor application Weight [kg] CRLI140 0,70 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Thermal overload relays Add-on blocks for independent mounting 22 Ordering codes RSTL3 RSTL3-80 RSTL3-90 RSTL3-110 RSTL3-120 RSTL3-135 RSTL3-150 RSTL3-160 RSTL3-180 Ordering codes RSTL4 RSTL4-125 RSTL4-200 RSTL4-250 RSTL4-320 RSTL4-400 Fuse links [A] Adjustment rated range [A] IEC947 - 4 55 - 80 63 - 90 80 - 110 90 - 120 110 - 135 120 - 150 135 - 160 150 - 180 ”1” ”2” 250 250 315 315 315 315 355 355 160 160 200 224 224 224 224 224 Fuse links [A] Adjustment rated range [A] IEC947 - 4 80 - 125 125 - 200 160 - 250 200 - 320 250 - 400 ”1” ”2” 500 500 500 500 800 250 315 400 400 500 Contactor application Weight [kg] CRLI170 CRLI205 0,70 Contactor application Weight [kg] CRLI250 CRLI300 CRLI400 2,50 Add-on blocks for independent mounting of thermal overload relays Ordering codes ❶ Set - 3 pieces www.relpol.com.pl Name Contactor application Weight [kg] CRI-310 Module for RSTM - for installing as a single unit, this module includes screw terminals CRMI05, CRMI09 0,01 CRI-320 Relay base for RSTN 1 - for installing as a single unit CRNI09, CRNI12 0,05 CRI-330 Relay base for RSTN 2 - for installing as a single unit CRNI16, CRNI22 0,05 CRI-340 Relay base for RSTN 3 - for installing as a single unit CRNI32, CRNI38 0,05 CRI-350 Relay base for RSTN 4 - for installing as a single unit CRNI45, CRNI63, 0,05 CRI-360 Box terminal block for RSTL1 - for installing as a single unit CRLI110 CRI-370 Links ❶ for RSTL2, RSTL3 - for connections to contactors CRLI140, CRLI170 CRI-382 Links ❶ for RSTL3, RSTL4 - for connections to contactors CRLI205, CRLI250 CRI-390 Links ❶ for RSTL4 - for connections to contactors CRLI250, CRLI300, CRNI75, CRNI85 CRLI400 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 0,2 Thermal overload relays Technical data 23 Technical data for release times up to 10 s according to IEC/EN 60947 Type of thermal overload relay Release time classification Phase failure protection RSTM RSTN1 / RSTN2 RSTN3 RSTN4 RSTL1 RSTL2 / RSTL3 RSTL4 Class 10 A (2 s < tA ≤ 10 s at 7,2 x Ie from cold state and tA ≤ 2 min. at 1,5 x Ie from hot state) Yes Yes Yes Yes Yes Yes Yes by differential phase shift Changeover to automatic reset RESET button with trip-free feature Temperature compensation Switch position indicator Test button actuates No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No ❶ Yes Yes No ❶ No ❶ No ❶ No ❶ the NO and NC contacts Terminal for contactor coil Permanent ambient temperature [°C] -25...+55 -25...+55 ❷ Degree of protection IPIP0000 (open) (open) oror IPIP 2020 toto IEC/EN IEC 947-1 60947 and and DIN DIN 4040050 050 8/10 Shock resistance [g/ms] Main circuit Rated current [A] 12 600 Rated voltage [V AC] Rated impulse strength Uimp [kV] Rated voltage of insulation Ui [V] ❸ 14,5 / 25 600 45 600 88 600 135 600 150 / 180 600 400 600 6 6 6 8 8 8 8 690 690 690 1000 1000 1000 1000 Type of current frequency DC, AC up to 400 Hz AC up to 400 Hz Conductor cross-sections Terminal screw • solid or stranded [mm2] M3 M4 M5 M5 M6 M8 M8 / M10 ❹ 0,5 to 2,5 2,5 to 6 1,5 to 25 2,5 to 35 25 to 70 50 to 120 185 / 240 ❹ • flat bars [mm] 0,5 to 1,5 – 1,5 to 4 – 1 to 16 – 1,5 to 25 – 25 to 50 – 25 to 95 20×3 – 20×3 / • tightening torque [Nm] 0,4 to 0,7 1 to 1,5 2,5 to 3 2,5 to 3 6 to 8 10 to 14 • tightening torque [Ib.in] 4 to 6,5 9 to 13 22 to 26,5 22 to 26,5 52 to 50 89 to 124 • finely stranded with end sleeve [mm2] 20×3×5 ❹ 10 to 14 / 14 to 24 ❹ 89 to 124 / 124 to 210 ❹ Power loss per current path (max.) • at lowest value [W (VA)] • at highest value of the setting range [W (VA)] 0,6 0,9 1,2 2,6 5 5 4 (5) 2,3 2,25 3 4 7 7/– 10 (12) Auxiliary circuit Auxiliary contacts 1NO + 1NC / 1 changeover 1NO + 1NC / 1NC 1NO + 1NC Conductor cross-sections Terminal screw • solid or stranded [mm2] M3 M3,5 2×(0,5 to 2,5) 2×(0,5 to 1) / 2×(1 to 2,5) 2×(0,5 to 1) / 2×(0,75 to 2,5) • finely stranded with end sleeve [mm2] 2×(0,5 to 1,5) • tightening torque [Nm] 0,4 to 0,7 • tightening torque [Ib.in] 4 to 6,5 0,8 to 1,4 7 to 12 600; > 150 same polarity 6 Rated voltage [V AC] Rated impulse strength Uimp [kV] Rated voltage of insulation Ui [V] ❸ 690 400 690 NC Unequal potential (NO + NC) Equal potential (NO + NC connected as changeover contact) Switching capacity B 600, R 300 at AC-15 • rated operating voltage Ue [V] • rated operating current Ie [A] at DC-13 24 60 125 230 400 500 690 24 60 110 220 2 1,5 1,25 1,15 1,1 1 0,8 2 0,5 0,3 0,2 • conventional termal current Ith [A] 6 Short-circuit protection ❶ For 35 mm DIN rail mount, EN 50022 Fusses Class gL/gG - 6 A ❷ For 75 mm DIN rail mount, EN 50023 ❸ Pollution severity 3 Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 ❹ Setting range (≤ 200 A / > 200 A) www.relpol.com.pl Thermal overload relays Technical data 24 Release time Adjustment rated range Conductor cross-sections [A] [mm2] Release time (±20%) with three-pole symmetrical load form the cold state. Adjusted current multiplication factor (x Ie) [s] 3 4 5 6 7,2 8 RSTM 0,1 - 0,16 1 23,8 14,5 10,5 8,3 6,8 5,8 0,16 - 0,25 0,25 - 0,4 1 1 22,5 22,8 14 14 10,1 10 8 7,8 6,5 6,3 5,5 5,4 0,4 - 0,63 1 23,5 14,1 10,2 8 6,5 5,6 0,63 - 1 0,8 - 1,25 1 1 25 27,5 15 16,7 10,8 11,8 8,3 9 6,8 7,2 5,7 6 1 - 1,6 1 25 15,5 11 8,6 7 5,9 1,25 - 2 1,6 - 2,5 1 1 26,5 27,4 17 17,3 12,7 12,7 10 10 8,4 8,3 7,2 7,2 2 - 3,2 1 29,5 18 12,9 10 8,1 6,7 2,5 - 4 3,2 - 5 1 1 28,5 29 17,5 17,6 12,4 12,3 9,6 9,5 7,8 7,5 6,5 6,3 4 - 6,3 1 28,5 17 11,9 9 7,2 5,8 5-8 6,3 - 10 1 1,5 29 25 17,5 14,1 12 9,4 9 6,8 7,1 5,2 5,8 4,2 8 - 12 RSTN1 1,5 29 17,2 12 9,2 7,3 6 0,1 - 0,16 1 16,7 10,3 7,5 5,9 4,8 4,1 0,16 - 0,25 0,25 - 0,4 1 1 20,5 18 12,8 11,2 9,5 8,2 7,5 6,5 6,3 5,4 5,4 4,6 0,4 - 0,63 1 20,8 12,8 9,5 7,6 6,3 5,4 0,63 - 1 0,8 - 1,25 1 1 23,3 28 14,4 17,5 10,5 12,7 8,3 9,8 6,8 8,1 5,8 6,8 1 - 1,6 1 22,6 14,3 10,4 8,3 6,8 5,9 1,25 - 2 1,6 - 2,5 1 1 22,3 24,5 14 15,5 10,3 11,5 8,4 9 6,9 7,5 6,0 6,4 2 - 3,2 1 23,8 15 11 8,8 7,3 6,3 2,5 - 4 3,2 - 5 1 1 24,4 27,5 15,6 17 11,4 12,2 9,1 9,5 7,6 7,8 6,5 6,5 4 - 6,3 1 23,4 14,4 10,4 8 6,5 5,5 5-8 6,3 - 10 1 1,5 22,5 24 13,5 13,9 9,5 9,3 7,2 6,8 5,7 5,3 4,7 4,3 8 - 12,5 2,5 24,5 14,8 10,2 7,8 6,2 5,2 10 - 14,5 RSTN2 2,5 23,2 13,9 9,5 7,2 5,6 4,6 4 - 6,3 1 23,4 14,4 10,4 8 6,5 5,5 5-8 6,3 - 10 1 1,5 22,5 24 13,5 13,9 9,5 9,3 7,2 6,8 5,7 5,3 4,7 4,3 8 - 12,5 2,5 24,5 14,8 10,2 7,8 6,2 5,2 10 - 16 12,5 - 20 2,5 2,5 23,2 23 13,9 13 9,5 8,6 7,2 6,3 5,6 4,8 4,6 3,9 16 - 25 4 31 17 11 7,7 5,8 4,6 RSTN3 8 - 12,5 2,5 24,5 14,8 10,2 7,8 6,2 5,2 10 - 16 2,5 26,2 15,8 10,8 8,1 6,4 5,2 12,5 - 20 16 - 25 2,5 4 26,6 29 14,8 15,4 9,7 9,8 7 7 5,3 15,3 4,3 4,2 20 - 32 6 28 16,1 10,8 8,2 6,3 5,2 25 - 36 32 - 40 10 10 33,4 24,3 19 13,6 12,8 8,8 9,3 6,6 7,2 5 5,8 4,2 36 - 45 10 23 13 8,5 6,2 4,5 3,3 www.relpol.com.pl Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Thermal overload relays Technical data 25 Release time Adjustment rated range Conductor cross-sections [A] [mm2] Release time (±20%) with three-pole symmetrical load form the cold state. Adjusted current multiplication factor (x Ie) [s] 3 4 5 6 7,2 8 19,5 18,5 13,2 12,8 9,7 9,4 7,6 7,4 6,2 6 RSTN4 12,5-20 16 - 25 20 - 32 4 6 34 33 25 - 40 10 30 17 11,5 8,4 6,5 5,3 32 - 50 40 - 57 10 16 29 35 16,6 19,4 11 12,3 8 8,7 6,2 6,6 5 5,3 50 - 63 16 37 20,5 13,3 9,6 7,3 5,8 57 - 70 63 - 80 25 25 40 40 21,5 21,5 14 13,8 9,8 9,7 7,4 7,3 5,8 5,8 70 - 88 35 33,9 17,6 11,8 8 6,5 4,9 RSTL1, RSTL2, RSTL3 55 - 80 25 36 21 13,5 9,8 7,5 6,1 63 - 90 35 44 24 15,5 11 8,5 6,7 80 - 110 90 - 120 35 50 43 40 22 21,8 14 14 10 10 7,7 7,5 6,1 5,9 110 - 135 120 - 150 50 50 32 35 18 19,5 11,7 12,8 8,4 9,4 6,4 7,2 5,1 5,8 135 - 160 70 38 20,6 13,8 10 7,6 6,2 150 - 180 RSTL4 95 37 20,5 13,5 9,7 7,4 6,0 80 - 125 50 25 16,8 13,1 11,1 9,9 9,1 125 - 200 160 - 250 95 120 24,4 23,8 16,1 13,9 11,9 10,3 9,8 8,5 8,4 7,3 7,4 6,5 200 - 320 185 25,6 15,5 10,9 8,5 7 6,4 250 - 400 240 25 15 10,5 8,5 7 6,2 Protection characteristics Item No. Adjusted current multiplication factor Release time Test condition 1 2 1,05 1,20 >2h❶ <2h❶ Cold state Hot state 3 1,50 < 2 min. ❶ Pre-heated for 2 hours with 1 adjusted current multiplication factor 4 7,2 2 s < Tp < 10 s, Class 10 A Cold state Hot state means heat the thermal overload relay into steady state with the current as shown in ”Item No. 1”. Adjusted current multiplication factor Any two phases Another phase 5 1,0 6 1,15 0,9 Release time Test condition >2h❷ Cold state 0 >2h❷ Hot state means heat the thermal overload relay into steady state Hot state with the current as shown in ”Item No. 1”. ❶ Release time with three-pole symmetrical load at ambient termperature +20 °C ❷ Release time with three-pole unsymmetrical load (phase-failure) at ambient termperature +20 °C Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Thermal overload relays Technical data 26 Tripping characteristics The current-time curves show the relationship between the tripping time from cold state and multiples of the set Fig. Typical tripping characteristics current Ie. When the relay is at operating temperature and carrying 1,0 x Ie, the tripping times are reduced to approximately 25%. curve 2 to two-pole loads. For single-pole loads the tripping curves lie between curves 2 and 3. For normal [min.] Tripping curve 3 is applicable to three-pole loads and must be heated. The thermal overload relays RSTM, RSTN, RSTL are suitable for protecting motors with phase control. For protecting single-phase or DC-loads, therefore, all three Tripping time operation, all three bimetallic strips of the overload relay Tripping curve 3 is then applicable. The release current with a three-pole symmetrical load [s] main conducting paths must be connected in series. is between 105% and 120% of the set current. Tripping current (average) [A] Internal connection diagrams RESET button RSTN1, RSTN2, RSTN3 OFF button RESET button RSTN4, RSTL1, RSTL2, RSTL3 OFF button Current transformer RESET button Thermal overload relay Connection leads Cu 4 mm2, 4 m long RSTL4 www.relpol.com.pl OFF button RSTL4 separate mounting of current transformer and thermal overload relay Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Thermal overload relays Technical data 27 Installation 1. Marks on panel (marks on thermal overload relays). ❻ ❶ ❻ ❺ ❹ ❷ ❸ ❼ ❺ ❽ ❹ ❷ ❸ ❼ Panel RSTN1, RSTN2, RSTN3 Panel RSTN4, RSTL1, RSTL2 ❶ Terminal for contactor coil ❷ Setting current adjusting scale ❸ RESET button (blue) H - manual A - automatic ❹ Switch position indicator (green) Tripping of a manual-resetting relay is indicated by a pin projecting from the front-plate ❺ ❻ ❼ ❽ Test button (red) Auxiliary contacts terminals Main circuit connection terminal No. It must correspond with terminal No. of contactor In case of separate mounting of RSTL, the set current must be set on the scale against the reference mark 2. Set the scale to the rated current of the load. 3. If the reset button points to H (manual) and the relay has been tripped, pressing the button puts the relay in operation again. Changing to automatic reset by pressing and turning the button anti-clock wise from H to A. 4. When the test button is actuated, the NC contact opens and the NO contact closes, therefore the auxililary circuit (simulation of overload tripping) can be tested. In the “manual” position, the relay is resetted when the blue reset button is pressed. In the “automatic” postion, the relay is reset automatically. In the automatic mode, there is a risk of self-switching when the button is released. 5. Mounting and operating position, the relays are shown in drawings. Thermal overload relay with CRNI contactor. Thermal overload relay with relay base or box terminal block Tripping relay to be installed as a single unit. - for installing as a single unit. Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Thermal overload relays Dimensions 28 Dimensions CRI10 type auxiliary contact Additional module (on thermal overload relay) RSTM + CRMI05 or CRMI09 contactor RSTN1 + CRNI09 or CRNI12 contactor RSTN2 + CRNI16 or CRNI22 contactor RSTN1 or RSTN2 or RSTN3 + relay base for installing as a single unit Thermal overload relay RSTN3 + CRNI32 or CRNI38 contactor d e f RSTN1 with CRI-320 RSTN2 with CRI-330 10 14,3 M4 M4 M3,5 M4 RSTN3 with CRI-340 18,2 M5 M5 with relay base *) Minimum clearance from the earthed parts. **) Dimension for the square OFF button (stroke 3 mm). Dimension for the round RESET button (stroke 2,5 mm) less 2,5 mm. 1) For 35 mm DIN rail mount, EN 50022. www.relpol.com.pl Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 Thermal overload relays Dimensions 29 Dimensions RSTN4 + relay base CRI-350 for installing as a single unit RSTN4 + CRNI45 for CRNI85 contactor a1 Type a2 a3 b1 b2 b3 c1 d1 d2 d3 e e1 f1 f2 f3 g g1 g2 CRNI45, CRNI63 90 113 70 117 175 100 132 10,5 26,5 25 102 31,5 80 63 122 28 4,8 6,1 CRNI75, CRNI85 100 123 80 133 194 110 140 10,5 26,5 25 116 31,5 89 71 132 39 5,5 6,1 RSTL1 to be installed with contactor CRLI110 RSTL2 to be installed with contactor CRLI140 or with box terminal block CRI-360 for installing as a single unit RSTL3 to be installed with contactor CRLI170 or CRLI205 *) Minimum clearance from the earthed parts. **) Dimension for the square OFF button (stroke 3 mm). Dimension for the round RESET button (stroke 2,5 mm) less 2,5 mm. 1) For 35 mm DIN rail mount, EN 50022. 2) Height and spacing of the connection rails can accmodated to CRLI110, CRLI170 contactors (not for RSTL2). Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 www.relpol.com.pl Thermal overload relays Dimensions 30 Dimensions RSTL1 + CRLI110 contactor, RSTL2 + CRLI140 contactor, RSTL3 + CRLI170 contactor a1 a2 a3 b1 b2 b3 c1 d1 d2 d3 e e1 e2 f1 f2 f3 g g1 g2 CRLI110 120 143 100 150 232 130 150 15 37 37 130 213 40 93 80 146 45 6,3 M6 CRLI140 120 143 100 150 232 130 150 20 42 37 139 215,5 40,5 93 80 146 45 6,3 M8 CRLI170 135 158 110 180 257 160 185 20 42 42 154 115 93 153 48 7 M8 Type 234 40 RSTL4 to be installed as a single unit Type RSTL4-125, -200 RSTL4-250, -300, -400 a 46 50 b 140 140 c 69 70 d 9 11 e 160 171 *) Minimum clearance from the earthed parts. **) Dimension for the square OFF button (stroke 3 mm). Dimension for the round RESET button (stroke 2,5 mm) less 2,5 mm. 1) Box terminal blocks only for CRLI110. 2) For 75 mm DIN rail mount, EN 50023. www.relpol.com.pl Export Sales Department phone +48 68 47 90 838 • Marketing Department phone +48 68 47 90 900 f 20 x 3 25 x 4 31 Returning Card originates from68 catalogues ”Contactors - new line” 11/2005 Export Sales Department phone +48 68 47 90 838 •This Marketing Department phone +48 47 90 900 www.relpol.com.pl