Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET LC-R061R3P For main and standby power supplies. Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C. Dimensions (mm) 0.187 (4.75) Terminal type: Faston 187 3.799 (96.5) Photo/Label for reference only. 0.925 (23.5) Battery case resin: Standard (UL94HB) Color is black. Dimensions 6V 1.3Ah 3.819 inches (97.0 mm) Width 0.945 inches (24.0 mm) Height 1.969 inches (50.0 mm) Total Height 2.165 inches (55.0 mm) .661 lbs. (0.30 kg) Approx. mass UL94HB Faston 187 LC-R061R3P Terminal voltage (V) Nominal Voltage Rated Capacity (20 hour rate) Length 7.2 6.9 6.6 6.3 6.0 5.7 5.4 5.1 4.8 4.5 4.2 3.9 0.065A 0.26A 0.13A 1.3A 0 1 2 4 6 8 10 20 40 60 2 (Minute) Temperature dependency of capacity (20 hour rate) Self discharge 77˚F (25˚C) Cycle use (Repeating use) 6 8 10 20 40 (Hour) 20 15 10 Approx. 50mΩ 102% 100% 85% 65% 91% 82% 64% 0.52 A or smaller Control voltage 7.25V to 7.45V (per 6V cell 25˚C) initial current 0.195 A or smaller Control voltage 6.8V to 6.9V (per 6V cell 25˚C) (Note) 30 0.6A initial current Trickle use Duration of discharge vs. Discharge current (Hour) Internal Resistance 1.3Ah 1.2Ah 1.05Ah 0.85Ah Duration of discharge Capacity 77˚F (25˚C) 20 hour rate (65mA) 10 hour rate (120mA) 5 hour rate (210mA) 1 hour rate (850mA) 1.5 hour rate discharge Cut-off voltage 5.25 V Fully charged battery 77˚F (25˚C) 104˚F (40˚C) 77˚F (25˚C) 32˚F (0˚C) 5˚F (-15˚C) Residual capacity after standing 3 months Residual capacity after standing 6 months Residual capacity after standing 12 months 5 4 3 2 1.5 104˚F (40˚C) 1 50 40 30 (Minute) (note) 4 Duration of discharge Characteristics Charge Method (Constant Voltage) 0.165 (4.2) Discharge characteristics 77°F (25°C) (Note) Specifications Standard Terminals and Resin 0.165 (4.2) 0.012 (0.3) 1.969 +- 0.039 3.656 (92.9) 0.945 +- 0.039 (24 +- 1) (50 +- 1) 3.819 +- 0.039 (97 +- 1) (Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values. VRLA BATTERIES 77˚F (25˚C) 20 32˚F (0˚C) 10 5˚F (-15˚C) 5 3 30 50 100 300 500 1 (mA) Discharge current 3 5 10 (A) AUGUST 2003 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.