Transcript
JUMP SUSPENDED LED
DIRECT, RIBBED MESOOPTICS LENS - SPLASHPERF CRI >80 4000K, 3600 lm/4ft Project: Spec Type: Catalog No: 1201LAEQS Qty Line Notes:
Ordering guide Product Type
Source
Color Temp *
Lumens *
Lower Optics
Upper Optics
1201
L
A
E
Q
S
Jump Symmetric
L
LED
A B C
4000K 3500K 3000K
G 2400 lm/4ft E 3600 lm/4ft
Q MesoOptics Lens
E No Perf P PixelPerf S SplashPerf
Run Length
04 4' 08 8' XX Total run length (4’ increments)
Wiring †
1 3 5 7 8 B
1 cct 1 1 cct w/ EM cct 2 1 cct w/ BP 3 1 cct w/ Dimming 1 cct w/ TW 2 cct A/B
Voltage
120V 277V 347V
Driver
E Standard
Finish
WStandard White T Titanium Silver B Black X Custom
* Nominal values within a range. Consult ies file for exact color temp and lumens † Consult website for complete list of standard wiring options
Mounting Hardware Mount Type
Consult separate mounting spec sheet for mount type options
Endcaps -
.
Suspension Length
Distance from ceiling to top of luminaire in inches
Integrated Controls Please indicate with check mark. Response Daylight Single Zone (DS)
© 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 1201LAEQS.pdf 02.15 page 1 of 3
JUMP SUSPENDED LED DIRECT, RIBBED MESOOPTICS LENS - SPLASHPERF Photometry 180 135
135
90
90 1600 cd
45
45 0
3% Up / 97% Down
0 45 90
3641 lm
Efficacy
80.0 lm/W
CCT
4037K
CRI
82
R9
18
Distribution
3% Up / 97% Down
Spacing Criteria (0/90/180°)
1.27/1.68/NA
Candela Distribution Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180
0 1111 1110 1086 1019 874 674 500 318 147 34 0 0 1 1 3 4 5 8 8 9 9
Horizontal Angle 22.5 45 67.5 1111 1111 1111 1105 1122 1135 1116 1217 1312 1106 1320 1501 981 1212 1389 742 886 987 526 582 621 326 344 357 153 165 175 42 52 54 10 18 25 9 18 26 9 19 26 10 19 25 10 18 24 10 17 22 9 15 19 9 13 16 9 10 11 9 9 9 9 9 9
90 1111 1135 1341 1565 1443 1016 630 362 176 53 28 28 28 27 26 23 20 16 12 9 9
Input Voltage
120V
Input Power
45.5W
Input Current
0.4A
Power Factor
0.991
Tested values – contact technical support for rated values. Off-state power zero unless certain controls are specified.
1201LAEQS.pdf 02.15 page 2 of 3
Fixture photometry has been conducted by an NVLAP accredited testing laboratory in accordance with IESNA LM-79:2008 Lumen maintenance of the LEDs has been tested by the manufacturer in accordance with IESNA LM-80:2008 IES files for this and other photometric options can be downloaded online at www.lightingproducts.philips.com
Coefficients of Utilization (%) Zonal Lumens 0 108 346 599 735 669 515 340 176 56 0 18 18 17 15 12 9 6 3 1 0
Electrical Specifications
© 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires
Values per 4ft unit
Total Output
RCR 0 1 2 3 4 5 6 7 8 9 10
Ceiling: Wall:
70 118 109 100 91 84 77 71 66 62 57 54
50 118 104 92 81 72 65 58 53 48 44 41
80
30 118 100 85 73 64 56 50 45 40 36 33
10 118 97 80 67 58 50 44 39 34 31 28
Avg. Luminance (cd/m2) Vertical Angle 55 65 75 85
Horizontal Angle 0 45 90 6965 5572 5442 5857 3804 3516 4183 2240 2023 2277 951 775
70 115 106 97 89 81 75 69 64 60 56 52
70 50 115 102 90 79 71 64 57 52 48 44 40
30 115 98 84 72 63 55 49 44 40 36 33
50 110 97 86 76 68 61 55 50 46 42 39
50 30 110 94 81 70 61 54 48 43 39 35 32
10 110 92 77 65 56 49 43 38 34 30 28
0 0 97 83 70 60 52 45 40 35 31 28 25
JUMP SUSPENDED LED DIRECT, RIBBED MESOOPTICS LENS - SPLASHPERF Options and Details
Optics & Styles
Housing
Mounting
20 gauge cold-rolled steel precision formed and welded with optional perforated patterns. Maximum 3.5lb/ft.
Variable position mounts are supplied for each joint and end. The mounts can be installed up to 18" from joints and end locations. Tamper-resistant aircraft cable grippers provide infinite vertical adjustment capability. Aircraft cable, crimp and cable gripper are independently tested to meet stringent safety requirements.
Optical System
Joints
White light emitted from the LED sources passes through a biconvex lens where it is internally reflected and laterally refocused. Light is then redirected by Miro Silver reflectors and exits through the optical lens assembly. The optical lens assembly consists of an acrylic extrusion with a ribbed profile holding a layer of MesoOptics film. MesoOptics homogenizes the light and color to ensure consistency while controlling high angle glare and creating an optical batwing distribution.
Self-aligning joining system with hands-free pre-joining wire access.
Standard Driver
Approvals
Dimming: 0-10V, 5-100%. Output is Class 2 rated.
Certified to UL, CSA and IES standards.
Lumen Maintenance
Finish
At an ambient temperature of 25°C, the LED lumen maintenance expectation is L80 (12k) >60,000 hrs.
High quality powder coated, available in matte white, black or titanium silver. Other factory and custom colors available on request.
Weight
Endcaps Endcaps are diecast aluminum, available in luminous sculpted (standard) or flat (optional).
Electrical Factory pre-wired to section ends with quick-wire connectors.
Environment Rated for dry or damp locations in operating ambient temperatures 0-40°C (32-104°F). Certain luminaire components may be adversely affected by contaminants. Damage caused by sulfur, chlorine, petroleum based solutions or other contaminants are not covered under warranty. Due to continuing product improvements, Philips Ledalite reserves the right to change the specifications without notice.
©2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 1201LAEQS.pdf 02.15 page 3 of 3
Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216
Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008