Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

High-Performance Passive Devices In the battle against passive intermodulation (PIM), CommScope unveils a new standard for passive components. Table of Contents Introduction Why permit a preventable weakness in your network?.......................................................4 What is PIM and what causes it?.....................................................................................4 All about PIM and our experiences High-performance active components are also highly susceptible to PIM...............................5 Deploy proactive, proven protection against PIM...............................................................6 PIM products in detail Part number description..................................................................................................7 Air Directional Couplers.................................................................................................8 Attenuators...................................................................................................................10 Coaxial Loads / Terminations..........................................................................................12 Tappers........................................................................................................................14 Hybrid Couplers............................................................................................................16 High Power Splitters.......................................................................................................17 CMAX SISO and MIMO Antennas...................................................................................18 2 For more information, visit commscope.com Why permit a preventable weakness in your network? To streamline the modernization of your LTE network, you invested a tremendous amount of time, energy, resources and expertise into a variety of active components. Imagine commissioning your new hardware, only to discover a massive, network-wide spike in PIM caused by your Achilles heel: low-quality passive components. Subscribers want it all Recent wireless usage statistics prove that today’s subscribers expect “five bars” of signal strength and instant data speeds— everywhere, all the time: 100% 4G LTE networks - and the sophisticated distributed antenna systems (DAS) supporting them—represent MORE. More capacity. More frequency bands. More data traffic. More powerful technology. More effective performance. More revenue potential. 2011 2012 2013 2014 2015 2016 80% 41% 40% 2017 66% 60% 20% 0% But the modern 4G LTE network is also far more complex than its predecessors. Capacity requirements are doubling every year, requiring higher carrier counts and more efficient modulations schemes. These challenges introduce a greater probability of PIM interference—and that can cause major deployment headaches for you. TRAFFIC VIA MOBILE DEVICES 6% 2012 2013 80% GROWTH ~ in data traffic across ~ WORLDWIDE WIRELESS NETWORKS BETWEEN 2012 AND 2013 Source: “Cisco Visual Networking Index: Global Mobile Data Traffic Forecast Update, 2013–2018”, Feb. 5, 2014 What is PIM and what causes it? In a passive non-linear radio frequency (RF) circuit, PIM is the interaction of fundamental signal frequencies that produces extra unwanted signals. These unwanted signals inadvertently produce many signals at other frequencies. These frequencies, called harmonics (integer multiples), are what cause signal interference. From an antenna performance perspective, PIM typically occurs when: From a design, deployment and usage perspective, PIM is typically caused by: • PIM products fail in the receiver band • Surface oxidation in the RF path • Two or more transmitter channels share a common antenna • Improperly torqued connectors • Transmitter signal levels are high • Insufficient metal plating • Transmitters and receivers are duplexed • Poor solder connections and splatters • Contact between dissimilar metals as a result of insufficient plating of metal • Structures or objects close to the cell site • Improperly torqued connectors • Structures or objects in close proximity to the site • Loose metal-to-metal contacts • Nearby ferromagnetic materials • Component vibration For more information, visit commscope.com 3 High-performance active components are also highly susceptible to PIM Over the years, PIM has evolved from a virtually unknown DAS performance metric into a critical system requirement. Network performance, as identified by download speed, is highly susceptible to smaller levels of distortion that significantly impact performance. Hyper-sensitive antennas and radios, multiple frequency overlays and more components in the RF path create an environment where the margin for error for PIM continues to shrink. Download speeds are critical in DAS environments like stadiums, where many components in the RF path can generate PIM. Splitters, hybrid couplers, directional couplers and tappers are being installed closer to active signal sources. To accommodate this closer proximity, minimum PIM specifications for these signal distribution components continue to rise. As a result, our suite of -160 dBc (-117 dBm) passive devices represents the high-performance innovation and cost-effective quality you’ve come to expect from the Andrew® portfolio of wireless solutions. Partner with a single-source, end-to-end, global network infrastructure provider We address PIM with a holistic, proactive approach. Nothing is left to chance. We begin with quality soldering and sealing. We use non-ferric designs, thorough testing procedures, precise field installation and performance optimization to mitigate PIM interference. We achieve this quality by blending emerging technology with world-class expertise and local insight supports by a global presence. Designed to support the extremely high data rates and multi-channel counts used in applications like MIMO, Andrew -160 dBc passives are engineered to meet spectrum allocations of 698-2700 MHz. 4 For more information, visit commscope.com 100% Tested Deploy proactive, proven protection against PIM To achieve consistent performance, every active device in your network must be supported by a series of passive devices. Yet for every 1 dB reduction in uplink caused by PIM, 11 percent of coverage is lost. Why take such a risk? Instead of trying to find and replace poorly performing passive components after installing them, use -160 dBc Passive Devices as part of your initial deployment. • Quickly and easily view PIM test data with our WebTrak® internet app • Offer the optimal customer experience provided by your technology • Minimize PIM issues during system optimization • Ensure the greatest possible coverage • Maximize data throughput • Accelerate time-to-market Get the PIM info you need Built and tested to last To ensure durable performance under extreme environmental conditions, our engineers expose components to a variety of stringent tests: • Electrical stress • 10G to 50G vibrations • Accelerated life testing (ALT/HALT) • +85° C to -35° C temperature fluctuations To learn more about our groundbreaking -160 Passives Devices, contact your local CommScope representative. View comprehensive testing results for your network online using CommScope’s WebTrak® app. View swept frequency plots for specific passive component related to PIM, VSWR, insertion loss, isolation and coupling. When performance is vital, peace of mind is priceless Every CommScope passive device is factory pretested to drive down signal-to-noise ratio and optimize MIMO antenna performance. When you see the Andrew brand on your CommScope couplers, hybrids, splitters and tappers, take confidence in the performance of your network. For more information, visit commscope.com 5 Part number descriptions In-building Antenna Model Number Sequence Antenna Type MIMO Brand PIM CMAX - D M 60 - C P Nominal Half Beam Width U S E i53 Frequency Group Outdoor Antenna Model Number Sequence Brand Environmental Rating CELLMAX - EXT - C CELLMAX - D - C P P U U S S E E - O Environmental Rating Frequency Group Splitter Model Number Sequence Device Type PIM Power S - * - C P U S Number of Outputs Frequency Group E - L - N i6 Connector Type Coupler, Hybrid Coupler and Tapper Model Number Sequence Device Type Connector Type H - * - C P Coupling Factor U S E - N - Ai6 Internal Construction Low IMD Frequency Group Termination Model Number Sequence Connector Type Termination T - * - N Power Rating PIM M Gender Connector Type AT - * - Attenuation 6 N - PIM FF ANTENNA TYPE O = Omni-directional D = Directional PIM i6 = -160dBc Low IMD i53 = -153dBc Low IMD ENVIRONMENTAL RATING O = Outdoor Rated EXT = Exterior FREQUENCY GROUP T = 300-500 MHz TETRA Band C = 800-1000 MHz Cellular/GSM Band P = 1700-2000 MHz PCN/PCS Bands U = 2000-2300 MHz UMTS/3G Bands S = 2300-2400 MHz Spread Spectrum Band E = 698-800/2400-2700 MHz Evolution Band W = 2700-3800 MHz NOMINAL HALF POWER BEAMWIDTH 30 = 30˚ 60 = 60˚ DEVICE TYPE S = Splitter C = Coupler CT = Tapper H = Hybrid T = Termination AT = Attenuator SPLITTERS * = 2, 3, or 4 ways L = Low power H = High power COUPLERS * = Coupling: 5, 6, 8, 10, 13, 15, 20, 30 dB A = Air dielectric low IMD TAPPERS * = Coupling factor: 6, 8, 10, 13, 15, 20, 30 dB i6 Attenuator Model Number Sequence Device Type BRAND CELLMAX = CommScope Cell-Max™ Antenna CMAX = CommScope Cell-Max™ Antenna i6 Interface Type For more information, visit commscope.com HYBRIDS * = Coupling factor: 3 dB A = Air dielectric low IMD TERMINATIONS * = Max power rating: 2, 10, 25, 30, 50,100 W M = Male F = Female S = Square section cooling element, default is round Air Directional Couplers These couplers are ideal for complex applications. They enforce very low passive intermodulation, minimize RF insertion loss and enable multiband frequency coverage. • N and DIN Connectors • 200 W N-type, 300W DIN7-16, -160 dBc C-6-CPUSE-D-Ai6 with 7-16 DIN Female connector • IP 65 for indoor and outdoor use • Air dielectric version of C-x-CPUSE-x-Ai6 range C-5-CPUSE-D-Ai6 C-5-CPUSE-N-Ai6 C-6-CPUSE-D-Ai6 C-6-CPUSE-N-Ai6 C-8-CPUSE-D-Ai6 C-8-CPUSE-N-Ai6 C-10-CPUSE-D-Ai6 C-10-CPUSE-N-Ai6 7-16 DIN Female N Female 7-16 DIN Female N Female 200 W 300 W General Specifications Brand Andrew® Device Type Interface Coupler 7-16 DIN Female N Female 7-16 DIN Female N Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Average Power, maximum Coupling Two +43 dBm carriers 300 W 200 W 4.8 dB 300 W 200 W 300 W 6.0 dB Coupling Tolerance 200 W 8.0 dB 10.0 dB ±1.0 dB Impedance 50 ohm Insertion Loss @ 698 – 2700 MHz 2.5 dB 1.6 dB 1.1 dB 0.7 dB Isolation @ 698 – 2700 MHz 25 dB 26 dB 28 dB 30 dB 70 W 100 W Peak Power, maximum 1 kW Reflected Power, maximum 30 W 40 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 36.00 mm | 1.42 in Length 169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 22.00 mm | 0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in Width 74.50 mm | 2.93 in 75.00 mm | 2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in Net Weight 900.00 g | 1.98 lb 380.00 g | 0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb Packed Dimensions Height 65.0 mm | 2.6 in 40.0 mm | 1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in Length 170.0 mm | 6.7 in 180.0 mm | 7.1 in 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in Width 110.0 mm | 4.3 in 90.0 mm | 3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in Shipping Weight 980.00 g | 2.16 lb 420.00 g | 0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb For more information, visit commscope.com 7 Air Directional Couplers C-30-CPUSE-N-Ai6 with N Female connector C-13-CPUSE-D-Ai6 C-13-CPUSE-N-Ai6 C-15-CPUSE-D-Ai6 C-15-CPUSE-N-Ai6 C-20-CPUSE-D-Ai6 C-20-CPUSE-N-Ai6 C-30-CPUSE-D-Ai6 C-30-CPUSE-N-Ai6 7-16 DIN Female N Female 7-16 DIN Female N Female 200 W 300 W General Specifications Brand Andrew® Device Type Coupler Interface 7-16 DIN Female N Female 7-16 DIN Female N Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Average Power, maximum Coupling Two +43 dBm carriers 300 W 200 W 13.0 dB Coupling Tolerance 300 W 200 W 300 W 15.0 dB 20.0 dB ±1.0 dB Impedance 200 W 30.0 dB ±1.2 dB 50 ohm Insertion Loss @ 698–2700 MHz 0.5 dB 0.4 dB 0.2 dB 0.2 dB Isolation @ 698–2700 MHz 33 dB 35 dB 40 dB 50 dB Peak Power, maximum 1 kW Reflected Power, maximum 200 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in 36.00 mm   |   1.42 in 22.00 mm   |   0.87 in Length 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in 169.00 mm   |   6.65 in 155.00 mm   |   6.10 in Width 74.50 mm   |   2.93 in 75.00 m m   |   2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in 74.50 mm   |   2.93 in 75.00 mm   |   2.95 in Net Weight 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 900.00 g   |   1.98 lb 380.00 g   |   0.84 lb 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 40.0 mm   |   1.6 in 180.0 mm   |   7.1 in Packed Dimensions Height Length 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in Width 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 90.0 mm   |   3.5 in Shipping Weight 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 980.00 g   |   2.16 lb 420.00 g   |   0.93 lb 8 For more information, visit commscope.com Attenuators These attenuators are ideal for high power applications where low PIM is essential. • Male to Female and Female to Female connector for both N-Type and DIN-type • 100 W average power AT-6-D-MFi6 with 7-16 DIN Female connector • IP65 for indoor and outdoor use • Low PIM, -160 dBc @ 2x43 dBm AT-3-N-FFi6 AT-6-N-FFi6 AT-6-D-MFi6 AT-6-N-MFi6 AT-10-N-FFi6 AT-10-D-MFi6 AT-10-N-MFi6 AT-15-N-FFi6 General Specifications Brand Andrew® Device Type Attenuator Interface N Female N Female 7-16 DIN Male N Male N Female 7-16 DIN Male N Male N Female Interface 2 N Female N Female 7-16 DIN Female N Female N Female 7-16 DIN Female N Female N Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Attenuation 3.0 dB Attenuation Tolerance ±0.8 dB 6.0 dB 10.0 dB 15.0 dB ±1.0 dB Average Power, maximum 100 W Impedance 50 ohm Return Loss, minimum 19.0 dB VSWR 1.25:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F) Relative Humidity Up to 100% Dimensions Height 89.00 mm | 3.50 in Length 210.00 mm | 8.27 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in Width 167.00 mm | 6.57 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in Net Weight 3.23 kg | 7.12 lb 89.00 mm | 3.50 in 3.12 kg | 6.88 lb 93.00 mm | 3.66 in 3.49 kg | 7.69 lb 89.00 mm | 3.50 in 3.16 kg | 6.97 lb 89.00 mm | 3.50 in 3.12 kg | 6.88 lb 93.00 mm | 3.66 in 3.49 kg | 7.69 lb 89.00 mm | 3.50 in 89.00 mm | 3.50 in 3.16 kg | 6.97 lb 3.12 kg | 6.88 lb Packed Dimensions Height 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in Length 220.0 mm | 8.7 in 270.0 mm | 10.6 in 285.0 mm | 11.2 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in 285.0 mm | 11.2 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in Width 190.0 mm | 7.5 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in Shipping Weight 3.41 kg | 7.52 lb 3.29 kg | 7.25 lb 3.65 kg | 8.05 lb 3.32 kg | 7.32 lb 3.29 kg | 7.25 lb 3.65 kg | 8.05 lb 3.32 kg | 7.32 lb 3.29 kg | 7.25 lb For more information, visit commscope.com 9 Attenuators AT-6-N-FFi6 with N Female connector AT-15-D-MFi6 AT-15-N-MFi6 AT-20-N-FFi6 AT-20-D-MFi6 AT-20-N-MFi6 AT-30-N-FFi6 AT-30-D-MFi6 AT-30-N-MFi6 General Specifications Brand Andrew® Device Type Attenuator Interface Interface 2 7-16 DIN Male N Male N Female 7-16 DIN Male N Male N Female 7-16 DIN Male N Male 7-16 DIN Female N Female N Female 7-16 DIN Female N Female N Female 7-16 DIN Female N Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Attenuation Two +43 dBm carriers 15.0 dB 20.0 dB Attenuation Tolerance 30.0 dB ±1.0 dB Average Power, maximum 100 W Impedance 50 ohm Return Loss, minimum 19.0 dB VSWR 1.25:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F) Relative Humidity Up to 100% Dimensions Height 93.00 mm | 3.66 in 89.00 mm | 3.50 in 89.00 mm | 3.50 in 93.00 mm | 3.66 in 89.00 mm | 3.50 in 89.00 mm | 3.50 in 93.00 mm | 3.66 in 89.00 mm | 3.50 in Length 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in Width 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in Net Weight 3.49 kg | 7.69 lb 3.16 kg | 6.97 lb 3.12 kg | 6.88 lb 3.49 kg | 7.69 lb 3.16 kg | 6.97 lb 3.12 kg | 6.88 lb 3.49 kg | 7.69 lb 3.16 kg | 6.97 lb Packed Dimensions Height 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in Length 285.0 mm | 11.2 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in 285.0 mm | 11.2 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in 285.0 mm | 11.2 in 270.0 mm | 10.6 in Width 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in Shipping Weight 3.65 kg | 8.05 lb 3.32 kg | 7.32 lb 3.29 kg | 7.25 lb 3.65 kg | 8.05 lb 3.32 kg | 7.32 lb 3.29 kg | 7.25 lb 3.65 kg | 8.05 lb 3.32 kg | 7.32 lb 10 For more information, visit commscope.com Coaxial Loads / Terminations These terminations/loads are ideal for high power applications where low PIM is essential. They cover from 10 W to 100 W and can be used to terminating unused/open RF port. • Male connectors and female connectors N-Type and DIN-type • IP65 for indoor and outdoor use T-30-NMi6 with N Male connector • Low PIM, -160 dBc @ 2 x 43 dBm T-10-DFi6 T-10-DMi6 T-10-NFi6 T-10-NMi6 T-30-DFi6 T-30-DMi6 T-30-NFi6 T-30-NMi6 7-16 DIN Female 7-16 DIN Male N Female N Male General Specifications Brand Andrew® Device Type Interface Termination Load 7-16 DIN Female 7-16 DIN Male N Female N Male Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +40 dBm carriers Average Power, maximum 10 W Two +43 dBm carriers 30 W Impedance 50 ohm Return Loss, minimum 19.0 dB VSWR 1.25:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F) Relative Humidity Up to 100% Dimensions Diameter 44.00 mm | 1.73 in Length 151.00 mm | 5.94 in 153.00 mm | 6.02 in 142.00 mm | 5.59 in 141.00 mm | 5.55 in 177.00 mm | 6.97 in 170.50 mm | 6.71 in 168.00 mm | 6.61 in 247.00 mm | 9.72 in Net Weight 0.60 kg | 1.32 lb 44.00 mm | 1.73 in 0.58 kg | 1.28 lb 44.00 mm | 1.73 in 0.52 kg | 1.14 lb 44.00 mm | 1.73 in 0.52 kg | 1.14 lb 54.00 mm | 2.13 in 0.81 kg | 1.79 lb 54.00 mm | 2.13 in 815.00 g | 1.80 lb 54.00 mm | 2.13 in 89.00 mm | 3.50 in 0.76 kg | 1.68 lb 3.12 kg | 6.88 lb Packed Dimensions Height 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in Length 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in Width 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in Shipping Weight 0.68 kg | 1.50 lb 0.66 kg | 1.46 lb 0.60 kg | 1.32 lb 0.60 kg | 1.32 lb 0.88 kg | 1.94 lb 900.00 g | 1.98 lb 0.83 kg | 1.83 lb 840.00 g | 1.85 lb For more information, visit commscope.com 11 Coaxial Loads / Terminations T-50-NFi6 with N Female connector T-50-DFi6 T-50-DMi6 T-50-NFi6 T-50-NMi6 T-100-DFi6 T-100-DMi6 T-100-NFi6 T-100-NMi6 7-16 DIN Male N Female N Male 75.00 mm | 2.95 in 75.00 mm | 2.95 in General Specifications Brand Andrew® Device Type Termination Load Interface 7-16 DIN Female 7-16 DIN Male N Female N Male 7-16 DIN Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 50 W 100 W Impedance 50 ohm Return Loss, minimum 19.0 dB VSWR 1.25:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F) Relative Humidity Up to 100% Dimensions Height 74.00 mm | 2.91 in Length 180.00 mm | 7.09 in 173.50 mm | 6.83 in 171.00 mm | 6.73 in 173.50 mm | 6.83 in 240.00 mm | 9.45 in 236.00 mm | 9.29 in 231.00 mm | 9.09 in 230.00 mm | 9.06 in 74.00 mm | 2.91 in 74.00 mm | 2.91 in 74.00 mm | 2.91 in 75.00 mm | 2.95 in 75.00 mm | 2.95 in Width 60.00 mm | 2.36 in 60.00 mm | 2.36 in 60.00 mm | 2.36 in Net Weight 1290.00 g | 2.84 lb 1310.00 g | 2.89 lb 1.23 kg | 2.71 lb 60.00 mm | 2.36 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 1.25 kg | 2.76 lb 2.54 kg | 5.60 lb 2.53 kg | 5.58 lb 2.45 kg | 5.40 lb 2.46 kg | 5.42 lb Height 75.0 mm | 3.0 in 65.0 mm | 2.6 in 73.0 mm | 2.9 in 65.0 mm | 2.6 in 65.0 mm | 2.6 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in 105.0 mm | 4.1 in Length 210.0 mm | 8.3 in 200.0 mm | 7.9 in 210.0 mm | 8.3 in 200.0 mm | 7.9 in 200.0 mm | 7.9 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in 270.0 mm | 10.6 in Width 90.0 mm | 3.5 in 85.0 mm | 3.3 in 90.0 mm | 3.5 in 85.0 mm | 3.3 in 85.0 mm | 3.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 135.0 mm | 5.3 in 1500.00 g | 3.31 lb 0.66 kg | 1.46 lb 1.44 kg | 3.17 lb 1.45 kg | 3.20 lb 0.88 kg | 1.94 lb 2.72 kg | 6.00 lb 2.64 kg | 5.82 lb 2.65 kg | 5.84 lb Packed Dimensions Shipping Weight 12 For more information, visit commscope.com Tappers Tappers support indoor applications in the 700 LTE band, 900 MHz cellular/GSM band, PCS/DCS-1800 band, and the 3G band to 2700 MHz. Each unit couples a defined fraction of high-power cellular signal with minimal reflections or loss. The wide frequency range is ideal for multiband antennas, radiating cable systems and in-wire base stations. • N and DIN Connectors CT-6-CPUSE-D-Ai6 with 7-16 DIN Female connector • IP 65 for indoor and outdoor use • Low dissipation loss • Spring clip makes wall mounting easy CT-6-CPUSE-Di6 CT-6-CPUSE-Ni6 CT-8-CPUSE-Di6 CT-8-CPUSE-Ni6 CT-10-CPUSE-Di6 CT-10-CPUSE-Ni6 CT-13-CPUSE-Di6 CT-13-CPUSE-Ni6 7-16 DIN Female N Female 7-16 DIN Female N Female 200 W 300 W General Specifications Brand Andrew® Device Type Tapper Interface 7-16 DIN Female N Female 7-16 DIN Female N Female Color Silver Electrical Specifications Operating Frequency Band 698 – 960 MHz   |   1710 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 300 W 200 W Coupling 300 W 200 W 6.0 dB 300 W 8.0 dB Coupling Tolerance 13.0 dB ±1.0 dB ±1.25 dB 0.7 dB @ 1710–2700 MHz 0.7 dB @ 698–960 MHz 0.6 dB @ 1710–2700 MHz 0.6 dB @ 698–960 MHz ±0.8 dB Impedance 200 W 10.0 dB 50 ohm 1.6 dB @ 1710–2700 MHz 1.6 dB @ 698–960 MHz Insertion Loss at Frequency Band 1.1 dB @ 1710–2700 MHz 1.1 dB @ 698–960 MHz Peak Power, maximum 3 kW Reflected Power, maximum 200 W Return Loss, minimum 17.7 dB 19.1 dB 20.8 dB 1.3:1 1.25:1 1.2:1 VSWR Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 28.90 mm   |   1.14 in Length 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 25.00 mm   |   0.98 in 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in Width 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in Net Weight 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in Packed Dimensions Height Length 180.0 mm   |   7.1 in Width 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in Shipping Weight 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb For more information, visit commscope.com 13 Tappers CT-30-CPUSE-N-Ai6 with N Female connector CT-15-CPUSE-Di6 CT-15-CPUSE-Ni6 CT-20-CPUSE-Di6 CT-20-CPUSE-Ni6 CT-30-CPUSE-Di6 CT-30-CPUSE-Ni6 N Female 7-16 DIN Female N Female General Specifications Brand Andrew® Device Type Tapper Interface 7-16 DIN Female N Female 7-16 DIN Female Color Silver Electrical Specifications Operating Frequency Band 698 – 960 MHz   |   1710 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Average Power, maximum Two +43 dBm carriers 300 W 200 W Coupling 300 W 200 W 15.0 dB 300 W 20.0 dB Coupling Tolerance 200 W 30.0 dB ±1.25 dB ±1.5 dB Impedance 50 ohm Insertion Loss at Frequency Band 0.2 dB @ 1710–2700 MHz 0.2 dB @ 698–960 MHz 0.1 dB @ 1710–2700 MHz 0.1 dB @ 698–960 MHz Peak Power, maximum 3 kW Reflected Power, maximum 200 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in 28.90 mm   |   1.14 in 25.00 mm   |   0.98 in Length 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in 153.60 mm   |   6.05 in 141.00 mm   |   5.55 in Width 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in 49.30 mm   |   1.94 in 43.00 mm   |   1.69 in Net Weight 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 350.00 g   |   0.77 lb 260.00 g   |   0.57 lb 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in 50.0 mm   |   2.0 in 40.0 mm   |   1.6 in Packed Dimensions Height Length 180.0 mm   |   7.1 in Width 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in 95.0 mm   |   3.7 in 90.0 mm   |   3.5 in Shipping Weight 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 420.00 g   |   0.93 lb 310.00 g   |   0.68 lb 14 For more information, visit commscope.com Hybrid Couplers Hybrid couplers combine two wireless carriers to a single antenna feed or cable. They maximize isolation in wireless bands by using a few solder joints and contain an air dielectric to minimize loss and enhance reliability. One feed requires the termination of an output port in 50 ohms and results in a 3 dB loss per signal. Using both outputs for two similar feeds eliminates the loss. • N and DIN Female Connectors • IP 65 for indoor and outdoor use • 200-watt average power rating • Combines non-coherent signals H-3-CPUSE-D-Ai6 with 7-16 DIN Female connector H-3-CPUSE-D-Ai6 H-3-CPUSE-N-Ai6 General Specifications Brand Andrew® Device Type Interface Hybrid 7-16 DIN Female Color N Female Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 200 W Coupling 3.1 dB Coupling Tolerance ±0.5 dB Impedance 50 ohm Insertion Loss at Frequency Band 0.2 dB @ 698–2700 MHz Isolation at Frequency Band 26 dB @ 698–2700 MHz Peak Power, maximum 1 kW Reflected Power, maximum 200 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 36.00 mm   |   1.42 in Length Width Net Weight 26.00 mm   |   1.02 in 138.00 mm   |   5.43 in 96.00 mm   |   3.78 in 85.00 mm   |   3.35 in 0.90 kg   |   1.98 lb 0.50 kg   |   1.10 lb Packed Dimensions Height 60.0 mm   |   2.4 in 50.0 mm   |   2.0 in Length 170.0 mm   |   6.7 in 180.0 mm   |   7.1 in Width 110.0 mm   |   4.3 in 95.0 mm   |   3.7 in Shipping Weight 1.00 kg   |   2.20 lb 0.60 kg   |   1.32 lb For more information, visit commscope.com 15 Hybrid Couplers Multiband 4x4 High Power Hybrid Matrices combine 4 input signals into 4 output signals with minimum dissipative loss. Hybrid Matrices can be used for indoor or outdoor applications. Hybrid Matrices now use air dielectric technology and as a result offer very low intermodulation characteristics over a wider frequency range. A wide frequency range allows for use with single or multiband signal sources. The device is designed to maximize the isolation and minimize intermodulation. • N and 7-16 DIN Female Connectors • Multiband frequency ranges from LTE 700 MHz, SMR/cellular, PCS, UMTS and 3G band to 2700 MHz • • • • H-4X4-CPUSE-DAi6 with 7-16 DIN Female connector Minimal RF insertion loss Low PIM, -160 dBc @ 2 x 43 dBm High reliability Connects 4 inputs to 4 outputs H-4X4-CPUSE-DAi6 H-4X4-CPUSE-NAi6 General Specifications Brand Andrew® Device Type Hybrid Interface 7-16 DIN Female Color N Female Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 100 W Coupling 6.1 dB Coupling Tolerance ±1.0 dB Impedance 50 ohm Insertion Loss at Frequency Band 0.3 dB @ 698–2700 MHz Isolation at Frequency Band 25 dB @ 698–2700 MHz Peak Power, maximum 1 kW Reflected Power, maximum 100 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 34.00 mm   |   1.34 in 31.00 mm | 1.22 in Length 191.00 mm | 7.52 in 181.00 mm | 7.13 in Width 191.00 mm | 7.52 in 181.00 mm | 7.13 in 1.80 kg | 3.97 lb 1.50 kg | 3.31 lb Net Weight Packed Dimensions Height 45.0 mm | 1.8 in Length 210.0 mm | 8.3 in Width 210.0 mm | 8.3 in Shipping Weight 16 2.30 kg | 5.07 lb For more information, visit commscope.com 2.00 kg | 4.41 lb High Power Splitters Multiband high-power splitters evenly distribute high-power signals with minimal reflections or loss. The reactive design employs no resistors, eliminating potential PIM damage. The SMR, PCS, UMTS and LTE frequency range enables use with single or multiband antennas and radiating cable systems. Minimal solder joints and an air dielectric enhance reliability. • 7-16 DIN Female Connectors • IP 65 for indoor and outdoor use • Low dissipation loss • Spring clip makes wall mounting easy S-2-CPUSE-H-Di6 S-2-CPUSE-H-Ni6 S-4-CPUSE-H-Ni6 with N Female connector S-3-CPUSE-H-Di6 S-3-CPUSE-H-Ni6 S-4-CPUSE-H-Di6 S-4-CPUSE-H-Ni6 N Female 7-16 DIN Female N Female General Specifications Brand Andrew® Device Type Interface Splitter 7-16 DIN Female N Female 7-16 DIN Female Color Silver Electrical Specifications Operating Frequency Band 698 – 2700 MHz 3rd Order IMD -160 dBc (relative to carrier) 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 300 W Impedance 50 ohm Insertion Loss at Frequency Band 0.2 dB @ 698–2700 MHz 0.3 dB @ 698–2700 MHz Peak Power, maximum 3 kW Power Rating, Splitting 300 W Reflected Power, maximum 300 W Return Loss, minimum 20.8 dB Split Loss 17.7 dB 3.0 dB 4.8 dB VSWR 6.0 dB 1.2:1 1.3:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-13 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 25.00 mm   |   0.98 in 25.00 mm   |   0.98 in 49.00 mm   |   1.93 in 43.00 mm   |   1.69 in 49.00 mm   |   1.93 in 43.00 mm   |   1.69 in Length 156.00 mm   |   6.14 in 150.00 mm   |   5.91 in 165.00 mm   |   6.50 in 159.00 mm   |   6.26 in 239.00 mm   |   9.41 in 227.00 mm   |   8.94 in Width 73.00 mm   |   2.87 in 61.00 mm   |   2.40 in 73.00 mm   |   2.87 in 61.00 mm   |   2.40 in 73.00 mm   |   2.87 in 61.00 mm   |   2.40 in Net Weight 382.00 g   |   0.84 lb 261.00 g   |   0.58 lb 459.00 g   |   1.01 lb 300.00 g   |   0.66 lb 590.00 g   |   1.30 lb 390.00 g   |   0.86 lb Height 40.0 mm   |   1.6 in 40.0 mm   |   1.6 in 65.0 mm   |   2.6 in 65.0 mm   |   2.6 in 75.0 mm   |   3.0 in 62.0 mm   |   2.4 in 260.0 mm   |   10.2 in Packed Dimensions Length 180.0 mm   |   7.1 in 180.0 mm   |   7.1 in 170.0 mm   |   6.7 in 170.0 mm   |   6.7 in 290.0 mm   |   11.4 in Width 90.0 mm   |   3.5 in 90.0 mm   |   3.5 in 110.0 mm   |   4.3 in 110.0 mm   |   4.3 in 98.0 mm   |   3.9 in 82.0 mm   |   3.2 in Shipping Weight 445.00 g   |   0.98 lb 318.00 g   |   0.70 lb 546.00 g   |   1.20 lb 380.00 g   |   0.84 lb 690.00 g   |   1.52 lb 470.00 g   |   1.04 lb For more information, visit commscope.com 17 CMAX SISO and MIMO Antennas These compact wideband antennas are designed to last and 100% tested for VSWR and PIM. Low IMD versions are treated with even further attention to detail: all joints are soldered, and only the very highest quality components are used. • • • • Multiband frequency range: SMR/cellular, PCS, UMTS, and LTE Homogenous patterns Solid PIM performance Compact design CMAX-OMF1-CPUSEi53 CMAX-DMF-CPUSEi53 CMAX-D-CPUSEi53 CMAX-O-CPUSEi53 CMAX-OMH-CPUSEi53 Omni MIMO Directional MIMO Directional SISO Omni SISO Omni MIMO Thru-hole ceiling mount (optional) Thru-hole ceiling mount (optional) General Specifications Antenna Type Application Indoor Operating Frequency Band 698 – 960 MHz   |   1710 – 2700 MHz Brand Andrew® Includes Mounting bracket Mount Type Thru-hole ceiling mount (optional) Number of Ports, all types 2 4-hole wall mounting plate and hardware 2 Package Quantity 1 2 1 Pigtail Cable 670-141SXE, plenum rated Electrical Specifications PIM Value 3rd Order IMD -153 dBc (2 x 20 W, dBc) Gain, dBi Beamwidth, Horizontal, degrees 4.0 @ 698 – 800 MHz 6.4 @ 698 – 800 MHz 6.0 @ 698 – 800 MHz 2.0 @ 698 – 800 MHz 1.5 @ 698 – 800 MHz 4.2 @ 800 – 960 MHz 7.2 @ 800 – 960 MHz 6.0 @ 800 – 960 MHz 2.0 @ 800 – 960 MHz 1.5 @ 800 – 960 MHz 5.5 @ 1710 – 2200 MHz 7.8 @ 1710 – 2200 MHz 7.0 @ 1710 – 2200 MHz 2.4 @ 1710 – 2200 MHz 3.5 @ 1710 – 2200 MHz 5.5 @ 2200 – 2700 MHz 7.6 @ 2200 – 2700 MHz 7.0 @ 2200 – 2700 MHz 3.3 @ 2200 – 2700 MHz 4.3 @ 2200 – 2700 MHz 360 @ 698 – 800 MHz 75 @ 698 – 800 MHz 90 @ 698 – 800 MHz 360 @ 698 – 800 MHz 360 @ 800 – 960 MHz 68 @ 800 – 960 MHz 83 @ 800 – 960 MHz 360 @ 800 – 960 MHz 360 @ 1710 – 2200 MHz 74 @ 1710 – 2200 MHz 65 @ 1710 – 2200 MHz 360 @ 1710 – 2200 MHz 360 @ 2200 – 2700 MHz 67 @ 2200 – 2700 MHz 88 @ 2200 – 2700 MHz 360 @ 2200 – 2700 MHz Beamwidth, Vertical, degrees 78.0 @ 698 – 800 MHz 72.0 @ 698 – 800 MHz 48.0 @ 698 – 800 MHz 55.0 @ 698 – 800 MHz 62.0 @ 800 – 960 MHz 53.0 @ 800 – 960 MHz 48.0 @ 800 – 960 MHz 55.0 @ 800 – 960 MHz 62.0 @ 1710 – 2200 MHz 46.0 @ 1710 – 2200 MHz 35.0 @ 1710 – 2200 MHz 42.0 @ 1710 – 2170 MHz 69 @ 2200 – 2700 MHz 50.0 @ 2200 – 2700 MHz 35.0 @ 2200 – 2700 MHz 42.0 @ 2200 – 2700 MHz Vertical Vertical @ 698 – 800 MHz | Vertical @ 800 – 960 MHz | Horizontal/ Vertical @ 1710 – 2700 MHz Frequency Band, MHz 698 – 960 / 1710 – 2700 Polarization at Frequency Band ±45° Impedance Vertical 50 ohm Mechanical Specifications Color White Pigtail Length Radome Material 500.0 mm   |   19.7 in 450.0 mm   |   17.7 in 420.0 mm   |   16.5 in 500.0 mm   |   19.7 in ABS, UV resistant ABS, UV resistant ABS ABS, UV resistant RF Connector Interface N Female Environmental Specifications Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F) Relative Humidity Up to 100% Dimensions Depth Height Length Width Outer Diameter Net Weight 18 72.0 mm   |   2.8 in 62 mm   |   2.4 in 318.0 mm   |   12.5 in 262.0 mm   |   10.3 in 210.0 mm   |   8.3 in 180.0 mm   |   7.1 in 1.0 kg   |   2.2 lb 850.0 g   |   1.9 lb 45.0 mm   |   1.77 in 200.0 mm | 7.9 in 0.5 kg | 1.0 lb For more information, visit commscope.com 135.00 mm   |   5.31 in 119.00 mm   |   4.69 in 204.0 mm   |   8.0 in 204.0 mm   |   8.0 in 0.4 kg   |   0.9 lb 0.5 kg   |   1.1 lb CMAX SISO and MIMO Antennas These antennas complement our omni-directional antennas and employ the exact same attention-to-detail in build quality. • Low PIM and outdoor variants • Homogenous patterns • Compact design • High gain CMAX-OMF-CPUSEi53 CMAX-DM20-CPUSEi53 CMAX-DM30-CPUSEi53 CMAX-DM60-CPUSEi53 CMAX-EXT-CPUSEi53 General Specifications Antenna Type Omni Directional MIMO Directional SISO Application Indoor Indoor   |   Outdoor Outdoor Operating Frequency Band 698 – 960 MHz   |   1710 – 2700 MHz Brand Andrew® Includes Mount Type Mounting bracket Poles between 30 – 55 mm with supplied clamps Thru-hole ceiling mount (optional) Number of Ports, all types 2 1 Package Quantity 1 Electrical Specifications PIM Value Gain, dBi Beamwidth, Horizontal, degrees 3rd Order IMD -153 dBc (2 x 20 W, dBc) 2.0 @ 698 – 800 MHz 12.0 @ 698 – 800 MHz 10.7 @ 698 – 800 MHz 8.5 @ 698 – 800 MHz 10.0 @ 698 – 800 MHz 2.0 @ 800 – 960 MHz 13.4 @ 800 – 960 MHz 11.2 @ 800 – 960 MHz 9.2 @ 800 – 960 MHz 11.0 @ 800 – 960 MHz 4.0 @ 1710 – 2200 MHz 12.5 @ 1710 – 2200 MHz 10.7 @ 1710 – 2200 MHz 9.2 @ 1710 – 2200 MHz 11.0 @ 1710 – 2170 MHz 4.0 @ 2200 – 2700 MHz 13.7 @ 2200 – 2700 MHz 11.1 @ 2200 – 2700 MHz 9.2 @ 2200 – 2700 MHz 11.0 @ 2200 – 2700 MHz 360 @ 698 – 800 MHz 26 @ 698 – 800 MHz 34 @ 698 – 960 MHz 62 @ 698 – 800 MHz 68 @ 698 – 800 MHz 360 @ 800 – 960 MHz 23 @ 800 – 960 MHz 29 @ 1710 – 2200 MHz 59 @ 800 – 960 MHz 60 @ 800 – 960 MHz 360 @ 1710 – 2200 MHz 22 @ 1710 – 2200 MHz 33 @ 1710 – 2200 MHz 54 @ 1710 – 2200 MHz 60 @ 1710 – 2170 MHz 360 @ 2200 – 2700 MHz 18 @ 2200 – 2700 MHz 30 @ 2200 – 2700 MHz 62 @ 2200 – 2700 52 @ 2200 – 2700 MHz Beamwidth, Vertical, degrees 63.0 @ 698 – 800 MHz 66.0 @ 698 – 960 MHz 62.0 @ 698 – 800 MHz 30.0 @ 698 – 800 MHz 61.0 @ 800 – 960 MHz 62.0 @ 800 – 960 MHz 58.0 @ 800 – 960 MHz 28.0 @ 800 – 960 MHz 63.0 @ 1710 – 2200 MHz 57.0 @ 1710 – 2200 MHz 55.0 @ 1710 – 2200 MHz 30.0 @ 1710 – 2200 MHz 60.0 @ 2200 – 2700 MHz 58.0 @ 2200 – 2700 MHz 62.0 @ 2200 – 2700 MHz 30.0 @ 2200 – 2700 MHz Frequency Band, MHz 698 – 960 / 1710 – 2700 Impedance Polarization 50 ohm Horizontal   |   Vertical ±45° Vertical Mechanical Specifications Color White Radome Material RF Connector Interface Off-white White ABS, UV resistant PVC, UV resistant N Female 7-16 DIN Female 686.0 N @ 216 km/h   |    154.2 lbf @ 216 km/h Wind Loading, maximum Wind Speed, maximum 294.0 N @ 216 km/h   |    66.1 lbf @ 216 km/h 216.0 km/h   |   134.2 mph Environmental Specifications Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature IEC 60529:2001, IP66 -40 °C to +60 °C (-40 °F to +140 °F) Relative Humidity Up to 100% Vibration Test Method ASTM D4169   |   IEC 60068-2-6 Dimensions Depth Height 127.0 mm   |   5.0 in 127.0 mm   |   5.0 in 124.5 mm   |   4.9 in 98.0 mm   |   3.9 in 150.0 mm | 1.77 in Length 881.4 mm   |   34.7 in 609.6 mm   |   24.0 in 299.7 mm   |   11.8 in 620.0 mm   |   24.4 in Width 340.4 mm   |   13.4 in 340.4 mm   |   13.4 in 299.7 mm   |   11.8 in 331.0 mm   |   13.0 in 8.0 kg   |   17.6 lb 7.0 kg   |   15.4 lb 2.9 kg   |   6.4 lb 4.7 kg   |   10.4 lb Outer Diameter Net Weight 230.0 mm | 9.1 in For more information, visit commscope.com 19 CommScope (NASDAQ: COMM) helps companies around the world design, build and manage their wired and wireless networks. Our network infrastructure solutions help customers increase bandwidth; maximize existing capacity; improve network performance and availability; increase energy efficiency; and simplify technology migration. You will find our solutions in the largest buildings, venues and outdoor spaces; in data centers and buildings of all shapes, sizes and complexity; at wireless cell sites and in cable headends; and in airports, trains, and tunnels. Vital networks around the world run on CommScope solutions. www.commscope.com Visit our website or contact your local CommScope representative for more information. © 2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. BR-108070.2-EN (08/15)