Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Report No: L121605901 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com L121605901 Report No: Report Prepared For: Model Number: Test: Issue Date: 2/8/2017 Revolution Lighting 4139 Guardian St. Simi Valley CA 93063 131330-001 Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Fixture is tested with no special conditions. Sample Arrival Date: 12/21/16 Date of Tests: Seasoning of Sample: 1/5/17 - 1/10/17 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter ITECH Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer Model No Stock No Calibration Due Date 61604 WT210 IT6122 52k/J RMG-C-MKII 2MR97 SPR-3000 PS-AC02 MT-EL06-S1 PS-DC03-S1 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2 -11/28/17 11/28/17 11/28/17 --Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4 Report No: L121605901 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W): Revolution Lighting 131330-001 N/A 2582.42 120.00 0.18 19.27 0.89 21% N/A 134 83 3046 0.4338 0.4032 25.0 1:05 1:35 0.00 FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4 Report No: L121605901 Percent Output 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Spectral Power 1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength W/m2nm 380 390 400 410 420 430 0.0009 0.0009 0.0016 0.0053 0.0252 0.0958 CRI & CCT x 0.4338 y 0.4032 u' 0.2489 v' 0.5206 CRI 83.30 CCT 3046 Duv 0.00009 R Values R1 81.53 R2 90.60 R3 96.96 R4 81.70 R5 81.64 R6 88.19 R7 84.22 R8 61.79 R9 12.72 R10 78.66 R11 80.94 R12 71.85 R13 83.50 R14 98.59 430 440 450 460 470 480 490 500 480 530 0.2849 0.5878 0.3056 0.2075 0.1861 0.2590 0.3551 510 520 530 540 550 560 570 580 Wavelength(nm) 0.4263 0.4724 0.5162 0.5728 0.6408 0.7170 0.8006 580 590 600 610 620 630 640 630 680 0.8839 0.9558 0.9965 0.9924 0.9430 0.8539 0.7413 650 660 670 680 690 700 710 730 0.6198 0.5015 0.3921 0.3002 0.2268 0.1690 0.1242 780 720 730 740 750 760 770 780 0.0908 0.0660 0.0479 0.0351 0.0257 0.0189 0.0162 CIE 1931 Chromaticity Diagram Y 0.9 520 0.8 530 540 510 0.7 550 560 0.6 570 500 0.5 580 590 0.4 0.4338, 0.4032 0.3 600 610 620 630 640 650 700 490 0.2 480 0.1 470 460 0 0 0.1 440 430 380 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4 Report No: L121605901 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 9 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605901.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L121605901 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 1/10/2017 [MANUFAC] REVOLUTION LIGHTING [LUMCAT] 131330-001 [LUMINAIRE] 20W 3000K E39 Semi-Directional Utility Lamp [BALLASTCAT] N/A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [INPUT] 120VAC, 19.27W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height N.A. (absolute) N.A. (absolute) 2582 N.A. 134 19.27 1.00 General Diffuse N.A. N.A. N.A. Rectangular w/Sides 0.06 ft 0.27 ft 0.31 ft LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 85604 91780 95337 97360 99476 67137 71297 74131 76317 78439 66553 83113 97268 109610 123144 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605901.IES CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0.0 0.00 35.54 85.20 142.16 215.56 286.14 355.90 429.13 496.56 562.32 617.96 664.46 703.16 733.21 753.97 769.92 779.88 784.36 782.37 774.40 755.80 713.62 659.98 621.11 584.58 543.23 492.74 413.36 345.27 293.62 216.56 147.81 83.54 34.54 2.49 0.50 0.00 22.5 0.00 29.15 65.93 121.15 188.41 253.93 323.26 384.96 451.97 508.85 561.58 605.67 643.95 676.75 699.09 714.12 724.99 730.31 729.89 724.58 706.14 676.50 632.08 591.39 548.54 503.95 455.21 397.00 335.97 274.69 206.93 147.22 87.52 39.28 5.23 0.50 0.00 45.0 0.00 28.98 61.03 103.88 156.28 203.19 251.35 300.01 348.67 390.85 424.23 454.46 478.87 499.13 514.91 525.62 532.35 535.92 535.17 529.86 515.99 492.82 464.42 436.03 403.97 371.92 334.80 296.61 253.68 208.59 156.77 110.27 65.68 27.98 5.31 0.58 0.00 67.5 0.00 18.85 36.12 66.01 98.81 131.95 165.58 204.94 236.49 265.22 289.80 311.47 327.08 343.86 354.90 362.29 366.36 368.10 367.35 364.12 355.98 342.28 323.76 305.99 283.74 259.41 234.16 202.69 175.04 144.07 110.36 84.53 48.16 21.67 7.22 0.58 0.00 90.0 0.00 15.53 23.67 37.28 55.80 74.57 93.42 112.02 131.53 152.29 172.63 189.57 203.27 214.40 221.46 225.86 228.10 228.35 226.61 223.70 218.22 208.84 197.79 186.75 172.22 156.44 139.92 122.56 104.05 83.45 62.86 44.01 26.41 13.04 4.98 1.33 0.00 112.5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 135.0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 157.5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. 180.0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605901.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 16.71 64.01 159.95 526.34 1078.29 1385.21 1383.53 143.23 297.78 626.24 551.95 292.10 306.92 576.61 803.52 978.66 1164.97 1197.21 620.60 2582.42 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 0.60 2.50 6.20 20.40 41.80 53.60 53.60 5.50 11.50 24.30 21.40 11.30 11.90 22.30 31.10 37.90 45.10 46.40 24.00 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 1.68 15.03 47.30 95.93 154.54 211.85 259.85 292.10 306.92 302.89 273.72 226.91 175.14 119.05 67.27 27.05 5.07 0.13 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605901.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 108 108 108 108 92 85 79 74 82 71 62 55 73 60 51 43 66 52 42 35 60 46 36 28 55 40 31 24 50 36 27 20 46 32 23 17 43 29 21 15 40 27 18 13 100 100 100 100 85 79 73 68 74 65 57 51 66 55 47 40 60 48 39 32 54 42 33 26 50 37 28 22 46 33 24 19 42 30 21 16 39 27 19 14 37 24 17 12 85 66 54 46 39 34 30 27 24 22 20 72 54 44 37 31 27 24 22 20 18 16 59 43 34 28 24 21 19 17 15 14 13 54 32 22 16 12 9 7 6 5 4 3 85 61 48 39 32 27 23 20 18 16 14 85 57 43 33 26 22 18 15 13 11 10 72 50 39 31 26 22 19 16 14 13 11 72 47 35 27 21 17 14 12 10 9 8 59 40 30 24 20 16 14 12 11 10 9 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. 59 38 27 21 16 13 11 9 7 6 6 Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605901.IES POLAR GRAPH 784 588 392 2 196 1 Maximum Candela = 784.36 Located At Horizontal Angle = 0, Vertical Angle = 85 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (85) (Through Max. Cd.) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 5