Transcript
F400-13
Item – ref.
Subject
Date
530253
Gas Burner Modification on T24
August 2011
WARNING: • • •
Carry out the handling according to the following manufacturers instruction Always respect warnings from the relevant manuals of the machines Make sure all electric power or other energy sources are disconnected and closed before any servicing, always turn of the main switch Wait 10 minutes after electrical power is disconnected to eliminate power on the inverter terminals Installation, maintenance and service must be executed by skilled service personnel only or by a service organisation with appropriate authorization from the manufacturer For service, use only original replacement parts Re-install all machine parts in the original way The qualified agency performing this work assumes all responsibility for this kit installation. Other service activities than described below, disable all manufacturers responsibility Make sure children are not around during work in progress
• • • • • •
Applicable machine models:
Dryers
Dryer Dryer Dryer Dryer
DAM5, DAMC5 DA9, DAM(S)(T)9 T9 T11, 13, 16
T1313, TAM13
Applicable type of spare parts:
Dryer Dryer Dryer Dryer Dryer Dryer
T24, 35 DA11, 13, 15 DA1313
D25, 35 D55, 77
General Chasis Cabinet Controler Coin unit
Heating unit Motor / pulley / belts Bearing house & seals Air filter Air fan
[email protected] www.primuslaundry.com
Drum Door Exhaust Electric components & sensors
Summary: The gas chamber on T24 dryers was modified to improve the air flow through the chamber. The result is a more equal flame and better distribution of heat. The flame tips cannot get out of the heating chamber. This modification prolongs the lifetime of the burner and prevents its cracking. This information is applicable for:
A. …
Paragraph-title
Applicable serial number
Involved ECN
Т24
< 24T004657TL
ECN2003&2096
It is not applicable for T35. There another modification is being prepared.
Explanation: A barrier and a few guiding plates were added inside the heating box of the dryer in order to guide the air equally along the burners. In case you want to upgrade an older dryer to this execution you have to replace the complete heating box. Use kit 541344 (see service instruction 541345).
Required tools: See service instruction 541345.
Required parts:
1 ...
Item
Description
Quantity
Unit
541344
Kit for gas chamber installation
1
pcs
In case you have further technical questions please do not hesitate to contact the Primus aftersales department. Page 2 of 2
Item-ref.: 530253