Transcript
F1-62 Mounting Hoods and Ballasts for Mercmaster II HID Lighting Fixtures Hood and Ballast Housings are Copper-Free Aluminum (4/10 of 1%).
Description
Hub Size (Inches)
Catalog Number Copper-Free Aluminum
3/4 1
LPA-75 LPA-100
3/4 1
LPC-75 LPC-100
3/4 1
LPWB-75 LPWB-100
1-1/4
LPS-125 LPS-150
Mounting Hoods Pendant One Hub, Rigid or Flexible Mounting Ceiling Five Hubs, Four Close-Up Plugs Wall Five Hubs, Four Close-Up Plugs 25° Stanchion One Hub
1-1/2
Mounting Adapter C^-*-^ > __^
T
Permits use of Mercmaster II pendant hood on existing V-51 and Mercmaster I mounting hoods. Remove Mercmaster I ballast body from existing mounting hood, thread in adapter and attach wires to Mercmaster II.
LPAD-1
Mercmaster II 50/250 Watt
Type
L f©»? I
5-1/2"!
Dia Thd.' ThH ' 'I Dia.
Ballast Body Number Lamp Globe/ Watts 12" Refractor 8" Refractor 120V
1
1
1
n
; 8
yfj -flm
-3/8" L_
Dia. Thd.
208V
240V
277V
480V
-MT -MT -MT
-DT -MT -MT -MT
-480 -480 -480
H.P. Sodium High Power Factor (Min. P.F. 90%)
50 70 100 150
LPB50L LPB70L LPB100L LPB150L
LPBLH50R LPBLH70R LPBLH100R LPBLH150R
-DT -MT -MT -MT
Metal Halide Constant Wattage (Min. P.F. 90%)
100 175 250
LPB100H LPB175H LPB250H
LPBH100R LPBH175R LPBH250R
-MTMED -MTMED -MTMED -MTMED -480MED -MT -MT -MT -MT -480 -MT -MT -MT -MT -480
Mercury Constant Wattage (Min. P.F. 90%)
100 175 250
LPB100M LPB175M LPB250M
LPBC100R LPBC175R LPBC250R
-MT -MT -MT
-MT -MT -MT
-MT -MT -MT
-MT -MT -MT
-480 -480 -480
Mercmaster II 250/400 Watt
I 1
Add Voltage Suffixes*
-MT -MT -MT
Refractor/ Reflector Lens
H.P. Sodium High Power Factor (Min. P.F. 90%)
250 400
LPBL250 LPBL400
-MT -MT
-MT -MT
-MT -MT
-MT -MT
-480 -480
Metal Halide Constant Wattage (Min. P.F.90%)
400
LPBH400
-MT
-MT
-MT
-MT
-480
Mercury Constant Wattage (Min. P.F. 90%)
400
LPBC400
-MT
-MT
-MT
-MT
-480
Note: "MT" (multi-volt) ballasts can be operated at an input voltage of either 120, 208, 240 or 277. "DT" (dual tap volt) either 120 or 277V. Effective October, 1993 Copyright 1993 Printed in U.S.A. PAGE 62
1701 West Wellington Avenue Chicago, Illinois 60657
F1-51 Mercmaster II Enclosed and Gasketed HID Lighting Fixtures High Pressure Sodium, Mercury Vapor and Metal Halide Mogul Base Lamp. UNILETS® for Use with Threaded Metal Conduit.
• Heat barrier isolates capacitor from ballast. Standard non-PCB biodegradable capacitors installed in separate compartment. • Mogul socket is furnished with 200°C welded leads, prewired to the ballast. • Porcelain socket assures trouble-free operation in high ambient installations. • HID Stylmaster fixtures ideal where mounting height is restricted and remote HID ballasts are required. • Guards protect globes from damage. Keyhole slots allow easy installation and are secured with stainless steel screws. • Prismatic glass globes and glass refractors are standard (plastic refractors also available) and thread directly into fixture housing. Eliminate glare and provide uniform light distribution. • Vented reflectors result in cooler, dirtfree operation, increased lumen output. • Reflectors secured to mounting hood with screws (furnished). • Choice of reflectors styles: white porcelain enamel or fiberglass-reinforced polyester; standard dome or 30° angle. • Optional photocell provides automatic "on-off" control. • All Mercmaster mounting hoods have provision for easy field installation of fuses in fixtures (see fuse kit listings). Standard Materials • Mounting hoods, ballast bodies and guards: aluminum (copper-free - 4/10 of 1% max.). • Reflectors:fiberglass-reinforcedpolyester. • Globes: 50W-100W, threaded prismatic glass; 150W, 175W, and 250W, threaded heat-resistant prismatic glass. • Refractors: 50W-150W, heat-resistant prismatic glass and plastic; 175W400W, prismatic glass. • Enclosed reflector: etched Alzak aluminum (copper-free - 4/10 of 1 %) with sealed, tempered heat and impact resistant lens.
Options • Fuses for fixtures. See listings. • MV and MH fixtures for quartz auxiliary lamps. Relay switch installed in fixture when specified. Add suffix -MTE to fixture catalog number for 120V thru 277V, and suffix -480E to fixture catalog number for 480V fixture. • "Rapid Smart Starter" emergency option, available for 50W-150W HPS only. Add suffix -HRE. See page F1-51.
Compliances • UL Listed. • UL Standard 1572, 844 and 595 (Marine). • Suitable for use in wet locations and outdoor saltwater locations. • Class I, Division 2, Groups A,B,C,D. Class II, Division 1 and 2, Groups E,F,G. References • For additional data on lamp and lighting fixture selection, see general introduction to catalog. Note: Fixtures equipped with optional photocell or quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
Conduit Hub with Setscrew
Stainless Steel Pin, Nut and Bolt
.Safety / Hinge
Silicone Rubber Body Gasket
Non-PCB Capacitor Encapsulated HPS Ignitor
Ballast Class H Insulation
High Temperature Nickel Plated Socket
Silicone Rubber Globe Gasket
Standard Finishes • Mounting hoods, ballast bodies, guards: EPOXY-CLAD finish. Two-coat baked finish, electrostatically applied for complete uniform surface protection. • Polyester reflectors: natural finish. Effective October, 1993 Copyright 1993 Printed in U.S.A.
Appleton •
I ELECTRIC COMPANY
1701 West Wellington Avenue Chicago, Illinois 60657 RAGE 51